Specification Technical Parameters

Electrical Characteristics

Backplane current: The backplane current is 2.2A, which determines the amount of current that the module receives from the backplane during operation and affects the power distribution and stability of the whole system. When designing the power supply system, it is necessary to ensure that the backplane can provide sufficient current to meet the normal operation requirements of the module and other equipment.

Heat dissipation: The heat dissipation is 37.54 BTU/hr, indicating that the module generates a certain amount of heat during operation and requires reasonable heat dissipation measures to ensure its stable operation. If the heat dissipation is not proper, it may cause the module temperature to be too high, affecting its performance and life.


Environmental Adaptability

Temperature range: 0 to 60°C (32-140°F) for operation and - 40 to 85°C (- 40 to 185°F) for storage. This allows the module to operate and be stored in a range of temperatures, but additional temperature regulation should be considered when using the module in extreme temperature environments.

Humidity Requirements: Relative humidity of 5 to 95% (non-condensing) indicates that the module can tolerate a certain range of humidity, but high humidity and condensing environments should be avoided to prevent electrical short circuits and other failures.


Mechanical properties

Shock resistance: 30g peak acceleration during operation, duration 11 ± 1ms; 50g peak acceleration during non-operation, duration 11 ± 1ms, which indicates that the module has a certain degree of shock resistance in the transport and use of the process, but in the actual application of the need to avoid a strong shock, so as not to damage the internal components.

Vibration Resistance: Withstands 2g of vibration with a peak-to-peak displacement of 0.012’ over a frequency range of 10 to 500Hz. This feature ensures that the module can work stably in industrial environments where vibration is present and reduces the risk of loosening connections or damaging components due to vibration.


Communication Capabilities

Communication protocols and ports: Ethernet (TCP/IP protocol) is used for communication, and the 15-pin AUI transceiver port connects to the network, ensuring compatibility with Ethernet devices and stability of data transmission.

Number of Connections: Supports 64 simultaneous connections, which can meet the needs of simultaneous communication of multiple devices. This parameter is very important for systems that require data interaction with multiple end devices, which determines the communication capacity and scalability of the system. The module also supports 512 unsolicited definitions (for the RSLinx and INTERCHANGE packages), which further enhances its communication capabilities in specific software environments.

Installation


Mounting Location: Mounted in the second left slot of the 1771-A1B, -A2B, -A3B, -A3B1, -A4B chassis and connected to the processor, the clear mounting location requirement helps to ensure that the module is installed correctly and operates correctly in the system.

Weight: 0.95 kg (2.1 lbs), a parameter that needs to be taken into account when designing the overall layout and mounting of the unit, especially for applications with stringent weight requirements.

Approvals: CSA Class I, Division 2, Groups A, B, C, D certification, UL listing and CE marking (for all relevant directives) signify that the module meets the relevant safety and quality standards and is safe for use in the respective area.


Module installation

Preparation for installation: Use specific programming software and corresponding processor, check the module packaging, record the Ethernet hardware address, prepare installation tools and equipment, and take precautions against static electricity.

Installation Procedure: Connect the connector plug to the processor, connect the interface module to the processor, and install the combo module into the leftmost slot of the 1771 I/O chassis. Installation requires attention to pin alignment and power down.

Removing the Module: To remove the module, disconnect the power, lift the locking lever and eject the tabs, and loosen the screws to separate the module.


Module Configuration

Configuration preparation: Each Ethernet hardware address should be assigned a unique IP address, which can be set manually or through the BOOTP protocol.

Configuration operation: Use programming software to specify the channel 3A support module, disable BOOTP, set diagnostic files, IP address and other parameters when configuring manually; when using BOOTP, you need to have a server and edit the BOOTPTAB file.


Communication Operation

Status monitoring: Judge the operation status of the module through the LED indicator after power on, the status indicator is always green when it is normal, and the transmission indicator turns green briefly when it is transmitting.

Connection Establishment: After establishing Ethernet connection, you can monitor the communication status data through the diagnostic file, including the sending and receiving of commands, replies, data packets, etc. and the error situation.

  • Bently Nevada 3500/60 163179-01 Temperature Monitor Module
  • BENTLY 3500/22M 288055-01 Enhanced TDI Module
  • BENTLY 3500/22M 146031-01 TDI Module
  • BENTLY 133396-01 3500/22M I/O Module
  • BENTLY 3500/34 TMR RMS Interface Module
  • BENTLY 128275-01-E Proximitor I/O Module
  • Bently Nevada 128276-011 Proximity Probe
  • Bently Nevada 135489-03 Accelerometer
  • Bently Nevada 135473-01 Seismic Transducer
  • Bently Nevada 1900/55 General Purpose Monitor
  • Bently Nevada ASSY78462-01U Proximitor Assembly
  • Bently Nevada 330100-90-01 Proximity Probe for Vibration Monitoring
  • Bently Nevada 330100-90-00 Proximity Probe for Machinery Monitoring
  • Bently Nevada 132419-01 Proximitor Sensor for Vibration Monitoring
  • Bently Nevada 10244-27-50-01 Proximity Probe Extension Cable
  • Bently Nevada 22810-01-05-50-02 Proximity Probe System
  • BENTLY 330980-51-00 3300 NSv Proximitor Sensor
  • BENTLY 330130-045-00-00 3300 XL Extension Cable
  • BENTLY 1X35668 Replacement Internal Module
  • BENTLY 3300/16 Dual XY Vibration Monitor
  • BENTLY 3500/15 133292-01 High Availability Power Supply
  • Bently Nevada 3500/62 163179-03 Process Monitor
  • Allen-Bradley 80190-100-01-R*3 Output Module
  • Allen-Bradley 80190-099-01 Analog Module
  • Allen-Bradley 80190-479-01 I/O Module
  • Allen-Bradley 80190-480-01-R Control Module
  • Bently 3500/15 125840-01 Power Supply Module
  • Bently 24765-02-01 Signal Conditioner Module
  • Bently 330130-085-00-00 Extension Cable
  • Bently 3500/22M 138607-01 Vibration Monitor Module
  • Bently 146031-02 Proximity Probe Sensor
  • BENTLY 330104-00-05-10-02-CN Proximity Probe
  • BENTLY 125768-01 3500 I/O Module Interface
  • BENTLY 3500/92 136180-01 Communication Gateway
  • BENTLY 84152-01 Proximitor Sensor Cable
  • BENTLY 3300/20 Dual Driver Proximitor Housing
  • BENTLY 3300/16-11-01-03-00-00-01 16-Channel Monitor
  • DEIF PPU-3 Power Protection Unit for Genset Control
  • DEIF RMV-112D Reactive Power Divider and Voltage Matching Relay
  • DEIF OPM-1 Output Protection Module for Gensets
  • DEIF IPM-1 Integrated Protection Module for Generators
  • DEIF CM-2 Control Module for Industrial Power Systems
  • DEIF PSM-1 Power System Manager Module
  • DEIF DELOMATIC-3 DGU2 Automatic Generator Control Unit
  • DEIF DLQ144-PC-NB Power Monitoring Meter
  • DEIF DU-2/MKIII Voltage Relay Controller
  • DEIF IOM4.2 Input/Output Module for Power Management
  • DEIF SCM-1 Synchronizing Control Module
  • DEIF GPU/2/GS Genset Parallel Unit Controller
  • EMERSON PR6426/010-110 CON021 Proximity System
  • EMERSON PR6423/011-110+C0N021 Proximity Sensor System
  • DEIF LSU-112DG Load Sharing Unit
  • DEIF PCM4.4 Advanced Power Control Module
  • DEIF TAC-311DG Transducer for AC Voltage
  • DEIF SCM4.1 Engine Start Control Module
  • DEIF PCM4.3 Power Control Module
  • Emerson 2500M/AI4UNIV Universal Analog Input Module
  • Emerson PR6424/011-140 Eddy Current Sensor
  • Emerson KJ3242X1-BK1 12P4711X042 Analog Input Module
  • Emerson FX-316 960132-01 Control Processor Module
  • Emerson KJ4006X1-BD1 Power Supply Module
  • EMERSON 1C31181G01 Ovation Analog Output Module
  • EMERSON CE4003S2B6 DeltaV Analog Module
  • EMERSON KJ4001X1-CK1 DeltaV I/O Carrier Card
  • EMERSON VE4012S2B1 DeltaV I/O Module Specifications
  • EMERSON SS6501T01 DeltaV System Assembly Technical Overview
  • Emerson A6370D/DP Display
  • Emerson P188.R2 Power Supply
  • Emerson A6824R 24-Ch Relay
  • Emerson KJ2201X1-JA1 Serial
  • Emerson VE3008 Main Controller
  • Emerson VE3008 CE3008 KJ2005X1-MQ1 Controller Module
  • Emerson TPMC917 Embedded Processor Module
  • Emerson P152.R4 Industrial Control Module
  • Emerson DA7281520 P152 Power Module
  • Emerson PR6423/008-110 Eddy Current Sensor
  • EMERSON 5X00273G01 Ovation DCS Digital Output Module
  • EMERSON KJ4001X1-NB1 12P3368X012 REV:E Redundant Controller Backplane
  • EMERSON KJ4001X1-NA1 12P3373X012 REV:C Intrinsically Safe Interface
  • EMERSON KJ4001X1-BE1 12P0818X072 REV:L DeltaV I/O Carrier
  • EMERSON KJ2221X1-BA1 DeltaV SIS SISNet Repeater Module
  • EMERSON PR6423/000-131 Eddy Current Sensor
  • EMERSON 5X00790G01 Ovation Digital Output Module
  • EMERSON 5X00846G01 Ovation Analog Input Module
  • EMERSON KJ4110X1-BA1 DeltaV Power Supply Base
  • EMERSON CSI3125 A3125/022-020 Dual Channel Monitor
  • EMERSON A6740 Displacement Case Expansion Monitor
  • EMERSON A6312/06 Speed Monitoring Module
  • EMERSON KJ4001X1-BE1 DeltaV Carrier Module
  • EMERSON SE3008 KJ2005X1-MQ2 DeltaV Controller
  • EMERSON KJ4001X1-CA1 DeltaV Terminal Block
  • Emerson PR6423/00R-010 CON031 Eddy Current Probe System
  • Emerson A6824 9199-00090 Operator Workstation
  • Emerson A6410 9199-00005 Operator Workstation
  • Emerson A6110 9199-00001 Operator Workstation
  • Emerson 9199-00002 A6120 Operator Workstation
  • Emerson KJ3002X1-BF1 12P1732X042 FIELDVUE DVC6200
  • Emerson 5X00500G01 Ovation Analog Output Module
  • Emerson VE4001S2T2B4 DeltaV Controller Module
  • Emerson 5X00502G01 Ovation Analog Input Module
  • Emerson A6824R 9199-00098-13 Operator Workstation
  • EMERSON A6140 9199-00058 Dual Channel Monitor
  • EMERSON VE3007 KJ2005X1-BA1 DeltaV Controller
  • EMERSON DB1-1 Connection Termination Block
  • EMERSON PMC-IO-ADAPTER Mezzanine Interface Card
  • EMERSON L0115012 L0115032 Solenoid Valve Components
  • Emerson A6410 Large Operator Workstation
  • Emerson A6210 Operator Workstation
  • Emerson 1C31232G02 Ovation Controller Module
  • Emerson 5X00106G02 Ovation Power Supply Module
  • Emerson 5X00106G01 Ovation Power Supply Module
  • EMERSON PMC-IO-PROZESSOR High-Speed I/O Module
  • EMERSON PMC PROFINET Communication Module
  • EMERSON MVME7100-0171 VMEbus Single Board Computer
  • EMERSON SE3008 KJ2005X1-SQ1 DeltaV MQ Controller
  • EMERSON PR6423/002-041 Eddy Current Displacement Sensor
  • Emerson SE4006P2 Serial Interface Module
  • Emerson KJ2201X1-HA1 Analog Input Module
  • EMERSON CE4001S2T2B4 DeltaV I/O Interface Module
  • EMERSON CE4003S2B1 DeltaV Controller
  • EMERSON KJ2003X1-BA2 DeltaV I/O Carrier
  • Enterasys A4H124-24TX P0973JM 24-Port Fast Ethernet Switch Module
  • Enterasys A2H254-16 P0973BK 16-Port Fast Ethernet Switch Module
  • Enterasys A4H254-8F8T P0973JP Matrix E5 Switch Module
  • Enterasys SSA-T8028-0652 P0973LN SecureStack Gigabit Switch
  • Enterasys A2H124-24FX P0973BJ
  • Enterasys SSA-AC-PS-625W P0973LQ Power Supply
  • Enterasys A2H124-24FX-RH Fiber Fast Ethernet Switch