Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

Rectifier module R48-3000E

F: | Au:佚名 | DA:2024-01-30 | 1115 Br: | 🔊 点击朗读正文 ❚❚ ▶ | Share:

Main functions and features

1. Hot-swap rectifier module adopts non-damage hot-swap technology, and its output and input have soft start units. When the module is inserted into the system, the output voltage of the system will not be disturbed. It takes less than one minute to replace a module.

2. Digital current equalization rectifier module adopts advanced digital current equalization technology, no monitoring module is required, the flow can be automatically equalized between modules, and the imbalance of the current is less than 1.5A.

3. Input power limit control rectifier module adopts advanced power limit control method according to the change of input voltage and output voltage. The transfer point is at 176V. When the input voltage is 176Vac ~ 290Vac, the module can output the maximum power; When the input voltage is 85Vac ~ 176Vac, it ensures the maximum load requirement and the reliable operation of the module at low input voltage.

4. When the input voltage is 176Vac ~ 290Vac, the maximum output power of the module is 3000W. When the load continues to increase, the output voltage will drop, when the output voltage is 48 ~ 58V, the output power is constant, the maximum is 3000W, that is, when the output voltage is 58V, the maximum output current is 50A; When the output voltage is 48, the maximum output current is 60.5A. When the output voltage is lower than 48V, the module adopts constant current mode and the output current is 60.5A.

5. Temperature limit power Below 45 ° C, the module can output 3000W at full power; 55℃ ambient temperature, the maximum output power of the module is 2380W; At an ambient temperature of 60℃, the maximum output power of the module is 1500W; At the ambient temperature of 65 ° C, the maximum output power of the module is zero.

6. Output current limiting point adjustment The current limiting point of the rectifier module can be adjusted continuously through the external monitoring module. The adjustment range is 0A to 60A, and the adjustment accuracy is ±1.5A.

Seven. Output voltage adjustment The output voltage of the rectifier module can be adjusted continuously through the external monitoring module. The adjustment range is 42V to 58V, and the adjustment accuracy is ±0.1V.

8. Fan control You can set the fan speed of the rectifier module to Full speed or Speed Regulation by using the monitoring module. If Speed Regulation is set, the module automatically adjusts the fan speed of the rectifier module based on the temperature. Set the fan to Full speed. The fan runs at its maximum speed. When AC overvoltage or undervoltage occurs, the fan stops running.

9. Fault and protection

1) Input over/Under voltage protection When the input voltage is less than 80Vac or greater than 295Vac, the protection indicator (yellow) is on, and the module stops working without output. When the input voltage is restored to the range of 95 ~ 295Vac, the rectifier module automatically recovers to normal operation. When a protection event occurs, the module reports the event to the monitoring module.

2) Output overvoltage protection The rectifier module has output overvoltage hardware protection and output overvoltage software protection. The hardware overvoltage protection point is between 59.5V and 60V. After hardware overvoltage protection, manual intervention is required to start the rectifier module. The software protection point can be set using the monitoring module. The value ranges from 56 to 59V, which must be 0.5V higher than the output voltage. The factory default value is 59V.

Software overvoltage protection mode can be selected by background maintenance software:

A. Primary overvoltage lock mode When software overvoltage occurs in the rectifier module, the rectifier module shuts down and maintains, requiring manual intervention to recover;

B. Secondary overvoltage lock mode When the output of the rectifier module reaches the software protection point and the output current is greater than 5A, the rectifier module shuts down and restarts 5 seconds later. If the second overvoltage occurs within the set time (the default is 5 minutes, which can be set by the monitoring module), the rectifier module shuts down and maintains, requiring manual intervention before starting. When the output of the rectifier module reaches the software protection point, but the output current is less than 5A, the rectifier module does not shut down. Manual intervention method: The rectifier module can be reset through the monitoring module, or it can be restored by removing the rectifier module from the power system. When an overvoltage fault occurs, the module reports a fault signal to the monitoring module for corresponding handling.

3) Overtemperature protection When the internal temperature of the module exceeds 85 ° C due to blocked air inlet, high ambient temperature, or fan fault, the output power of the module is reduced to 50% of the rated value. When the temperature inside the module reaches 90 ° C, the protection indicator (yellow) on the panel of the module is on, and the module stops working and has no output. After the abnormal conditions are cleared and the internal temperature of the module returns to normal, the module automatically returns to work. The overtemperature alarm is cleared. When overtemperature protection occurs, the module reports an alarm signal to the monitoring module for corresponding handling

4) PFC output over/Under voltage protection When the bus voltage inside the module exceeds the over/under voltage protection point, the module automatically shuts down for protection without output, and the protection indicator (yellow) on the panel of the module is on. When the PFC input overvoltage and undervoltage protection occurs, the module reports an alarm signal to the monitoring module for corresponding handling. 5) Fan Fault protection When the fan is faulty, the module generates a fan fault alarm, the fault indicator on the panel of the module blinks red, and the module shuts down without voltage output. After the fault is rectified, it automatically recovers to normal operation. When a fault event occurs, the module reports an alarm signal to the monitoring module for corresponding handling.

6) Short-circuit protection rectifier module adopts constant current protection mode, in the case of output short-circuit, the output current of the module remains constant, current ≤65A, effectively protect itself and external equipment; When the short circuit fault disappears, the module automatically recovers.

7) Output current imbalance When multiple rectifier modules are used in parallel in the system, the module with large current sharing error can automatically identify and light the protection indicator light (yellow light) on the panel of the module; If the output current of the module is seriously unbalanced, the module whose current equalization error is greater than 10A and the module has no output can automatically identify and light the fault indicator (red light) on the panel of the module. After the fault is rectified, it automatically recovers to normal operation. When a fault event occurs, the module reports an alarm signal to the monitoring module for corresponding handling.

8) Background communication interruption When the communication is interrupted, the protection indicator (yellow) of the module panel blinks. After the communication is restored, the protection indicator (yellow) on the panel of the module is restored. When the communication between modules is normal, the module automatically recovers. In order to protect the battery, when the module communication fails, the output voltage of the module changes to 53.5V (different voltages can be preset according to actual needs). 9) Module address conflict If the internal addresses of multiple rectifier modules on the power system are the same, the rectifier modules will generate an address conflict alarm, and the fault indicator (red) on the module panel will turn on. The rectifier module must be replaced.

10. The rectifier module has a built-in advanced digital signal processor DSP, which monitors and controls the operation of the whole module, and communicates with the external monitoring module through the CAN bus.

The details include:

1) You can control the on/off of the rectifier module through the monitoring module and set the output current slow start function and overvoltage protection reset mode of the module.

2) The output voltage, overvoltage point, output slow start time and current limiting point of the rectifier module can be adjusted through the monitoring module.

3) Send input voltage, output voltage, output current, current limiting point, temperature, overvoltage point to the monitoring module;

4) Send the on/off status to the monitoring module, and report the input protection, internal PFC over/under voltage protection, over temperature protection, over voltage off fault, fan fault, temperature power limit, input power limit, current imbalance, module address conflict and other fault information and technical parameters

1. Ambient conditions: Operating temperature: -5 ° C to 45 ° C, derated above 45 ° C Storage temperature: -40 ° C to 70 ° C Relative humidity: ≤95%RH, non-condensing Altitude: ≤2000m (derated above 2000m is required) Cooling mode: forced air cooling

2. Input feature: Input voltage range: 85Vac ~ 290Vac, single-phase three-wire rated input voltage range: 200Vac ~ 250Vac Power derated Input voltage range: 85Vac ~ 176VA Maximum static voltage when not working: 415Vac Rated input current: < 16A@3000W Maximum input current: < 19A@3000W/176Vac input impulse current: <30A Permissible input power grid frequency: 45 ~ 65Hz Rated input power grid frequency: 50Hz/60Hz 3 Output characteristics: Output DC voltage range: 42V to 58V Output DC current: 0A to 60.5A Voltage regulator Accuracy ≤± 0.5% Load adjustment rate ≤± 0.5% Voltage adjustment rate ≤± 0.1% upstroke amplitude ≤±1% 4. Output current limiting feature: stepless current limiting point 0A ~

Choose Xiamen control Smith after sale worry

Excellent product quality

Only cooperate with manufacturers of first-line brands in the industry

Imports/Products

Good pre-sale service

Communicated with customers repeatedly about product model, quality, price and delivery date

Work with the customer to determine the best solution

Address user concerns in advance

Business execution in place

Ordered products delivered on time

Make perfect delivery plan to ensure the time limit

Assist users to handle the acceptance procedures

Perfect after-sales service

During the warranty period, problems will only be replaced and not repaired

Never put a problem on the back of your head

Service hotline 7x24 hours service


Solemn promise

1. All the items sold by the company, module card parts, etc., the quality problems arising from normal use during the warranty period are replaced free of charge, and there is no evasion.

2. For materials and equipment that have not been discontinued beyond the warranty period, only the cost of relevant parts will be charged for quality problems.

3. Provide replacement models and equipment replacement process services for discontinued materials and equipment.

4. Customers have purchased materials and equipment, lifetime free upgrade system software, related technical information provided free of charge.

5. Visit the use of materials purchased by customers from time to time, and solve any problems in time.

6. The company hotline provides 24-hour service, and the questions raised by customers are answered within 1 hour.

7. Not done, the company spirit of "thoughtful service, responsible to the end" attitude, from the customer's point of view to solve the problem, with serious and rigorous enterprise style, dedicated to each customer service.




  • Rexroth R-IL S3 BK DI8 DO4-PAC Bus Coupler
  • Bosch Rexroth SB301 Tightening Unit 0608701017
  • Rexroth E-003-S-S Tool Cable 0608740220
  • Rexroth MSM020B-0300-NN-M0-CG0 Servo Motor
  • Rexroth IndraControl VEP30.3 Panel PC
  • Rexroth DBETE-62/315G24K31A1V Valve R901029969
  • Rexroth CSH01.3C-ET-ENS-NNN Control Section
  • Rexroth VT3013-37 Amplifier Control Card
  • Rexroth 1-2 TH6 L 162-10/N 05 Joystick
  • Rexroth ESV025 Handheld Nutrunner 0608841037
  • Rexroth RK2 S30 Amplifier Card VT 4224 U 261
  • Rexroth CDB01.1C-SE-ENS R911308279 Control Unit
  • Rexroth VFC3610-0K40-3P4-MNA-7P Inverter 0.4kW
  • Bosch Indramat HCS02.1E-W0028-A-03-NNNN Servo Module
  • Rexroth DKC01.3-040-7-FW EcoDrive R911279426
  • Rexroth HMV02.1R-W0015-A-07-NNN Utility Unit 15kW
  • Rexroth 0 608 830 193 ZSE220 Communication Module
  • Rexroth VT5003 S41 R5 Proportional Amplifier Card
  • Rexroth KSM02.1B-041c-42N-M1-HP0-ET-L3-D7-NN-FW Motor Drive
  • Mannesmann Rexroth VT5005 S16 R1 Valve Amplifier Card
  • Rexroth CFL01.1-R3 Sercos III Interface Module
  • Rexroth CKK-110-NN-1 Linear Axis with MSK040C
  • Bosch Rexroth 047018-104401 Controller Card
  • Rexroth MDSD1K-2X/4 Solenoid Driver Module
  • Rexroth DKC02.3-012-3-MGP-01VRS Servo Drive
  • Rexroth HCS01.1E-W0006 Compact Servo Drive
  • Rexroth NAM1.2-08 Line Former R911246505
  • Rexroth VPB40 Industrial PC Control Cabinet
  • Rexroth FWA-ECODR3-SGP-03-MS Firmware Module
  • Rexroth HEDE10-31 Pressure Switch R901425475
  • Rexroth HM 17-11/315-C/V0/0 Pressure Sensor
  • Rexroth VFC 3610-2K20-3P4-MNA-7P Inverter 2.2kW
  • Rexroth MSK040C-0600-NN-M1-UG1-NNNN Right Angle Geared Motor
  • Rexroth DKC02.3-012-3-MGP-01VRS EcoDrive Cs
  • Bosch Rexroth MSM031C-0300-NN-M0-CH0 Servo Motor
  • Rexroth HCS02.1E-W0012-A-03-NNNN Power Section
  • Rexroth DBDS 20 P18/400V Pressure Relief Valve
  • Rexroth 3460565500 Pneumatic EP Converter Regulator
  • Rexroth VT-SWA-1-12/DFEE Angle Sensor R900913641
  • Rexroth 0-608-830-250 Interface Module SM24V
  • Rexroth MHD071B-035-NP0-UN8 Servo Motor 12Nm 1000rpm
  • Rexroth MKD025B-144-KG0-KN R911263737 Servo Motor
  • Rexroth KCU02.2N-ET-ET*-025-NN-N-NN-NW Control Unit
  • Rexroth MV-VPB40*3-RB001VPB R911337529 Valve Terminal
  • Bosch Rexroth AS 2/R-2200 Drive Module 3842998041
  • Rexroth HMS01.1N-W0036 Power Section
  • Rexroth CKK-145-NN1 Compact Linear Module
  • Rexroth MS2N04-C0BTN-BSDK0-NNNNN-NN Geared Servo Motor
  • Rexroth HCS02.1E-W0028-A-03-NNNN Power Section
  • Rexroth MS2N04-D0BQN-CMSG0-NNNNN-NN Servo Motor
  • Rexroth MSM031C-0300-NN-M0-CH0 Servo Motor
  • Rexroth MKD041B-144-KP1-KN Servo Motor R911262307
  • Rexroth ESA075G Handheld Nutrunner 0608841033
  • Rexroth MSK070D-0450-NN-M1-UP1-NSNN Motor
  • Rexroth CKK-145-NNG1 Linear Kit with HCS02 Drive
  • Rexroth MSK060C-0300-NN-M1-UG0-NNNN Servo Motor
  • Rexroth MKD090B-047-KP1-KS Servo Motor
  • Rexroth MLS140S-3A-0450-NNN Linear Motor
  • Rexroth VPB40.3 Industrial PC R911338689 CB1
  • Rexroth HCS02.1E-W0012 Servo Drive R911313871
  • Rexroth R151349014 R151145672 Ball Screw Assembly
  • Bosch Rexroth CKK-110-NN-1 Compact Module
  • Rexroth MSK060B-0300-NN-M1-UG1-NNNN Servo Motor
  • Rexroth Indramat TBM 1.2-40-W1-024 Servo Bleeder
  • Rexroth MSK040B-0600-NN-M1-UG1-NNNN Servo Motor
  • Rexroth MLS200S-3A-0450-NNN R911299213 Linear Motor
  • Rexroth SB356 Tool Tightening Controller Rack
  • Rexroth MSK050C-0300-NN-M1-UG0-NNNN Servo Motor
  • Rexroth Indramat DKC11.3-040-7-FW Eco Drive
  • Rexroth VT2000 Proportional Amplifier
  • Rexroth VT1118-10 Analog Module
  • Rexroth MSK060C-0600-NN-M1-UP1-NSNN Motor
  • Rexroth MSK060C-0300-NN-S1-UG0-NNNN Motor
  • Rexroth R911173937 IndraControl XM AI1
  • Rexroth R412018225 AES-D-BC-ECAT Module
  • Rexroth CDB02.1B R911338542 Controller Card
  • Rexroth VT-HNC100-2-30/P-I-00/000 Module
  • Bosch Rexroth CSB02.1B R911372549 Control
  • Bosch Rexroth R185321310 Runner Block
  • Rexroth VPB40.3 Industrial PC R911338689
  • Rexroth HNK01.1A-A075-E0106-A-500 Drive Controller
  • Rexroth CSH02.1B-CC-EC-ET-S4-NN-NN-FW Controller
  • Rexroth CSB01.1C-PB-ENS-NNN Control Unit
  • Rexroth MKD041B-144-KP0-KN Permanent Magnet Motor
  • Rexroth SE-B2.020.030-14.000 Servo Motor
  • Rexroth MSK060C-0600-NN-M1-UG0-NNNN Servo Motor
  • Rexroth HCS01.1E-W0018-A-03-B Drive Controller
  • Rexroth 3 842 547 996 IE3 Geared Motor
  • Rexroth CSH01.1C-NN-ENS R911309709 Control Section
  • Rexroth R151349013 Ball Screw Nut
  • Mannesmann Rexroth VT3006-36 Analog Amplifier Card
  • Bosch Rexroth R900086160 PGF1 Gear Pump
  • Bosch Rexroth R911173263 VDP15.3 Touch Display
  • Bosch Rexroth PPC-R22.1 RJ522 Industrial Controller
  • Bosch Rexroth MSK060C-0300-NN-S1-UG0-NNNN Servo Motor
  • Bosch Rexroth R911325068 NYS04.1 Controller
  • Bosch Rexroth R911335439 CSH01.1C Control Unit
  • Bosch Rexroth R917010287 BODAS RC10 Controller
  • Bosch Rexroth R911329791 CSH01.1C Drive Controller
  • Bosch Rexroth R182432310 Runner Block Guide
  • Bosch Rexroth VT-VSPA2-1-11 Amplifier Card R900021909
  • Bosch Rexroth MKD090B-047-KG1-KN Servo Motor
  • Bosch Rexroth LTU350 Servo Amplifier 0608750108
  • Bosch Rexroth 5610102050 Pneumatic Vacuum Regulator
  • Bosch Rexroth VT5041-23/3-OV PLC Control Board
  • Bosch Rexroth VT3015 S10/E Servo Amplifier Board
  • Bosch Rexroth MSK070D-0300-NN-M2-UG1 Servo Motor
  • Bosch Rexroth 3DREP6C-21 Valve R900955887
  • Bosch Rexroth R151244013 Ball Screw Bearing Unit
  • Bosch Rexroth MSM031C-0300 Servomotor R911325140
  • Bosch Rexroth EMD-B16.1-DC024N Box R911291681
  • Bosch Rexroth MKD071B-061-GP0-KN Servo Motor
  • Bosch Rexroth MSK030C-0900-NN-M1-UG1 Servo Motor
  • Bosch Rexroth EcoDrive DKC01.3-004-3-MGP-01 Servo Controller (299772)
  • Bosch Rexroth DKC02.3-040-7 EcoDrive Controller
  • Bosch Rexroth CLC-D02.3 CLC Motion Control Board
  • Bosch Rexroth HDS05.2-W300N Drive R911190019
  • Bosch Rexroth DKCXX.3-100-7 Servo Drive Unit
  • Bosch Rexroth CSE02.1A-S3-EC Control Unit R911339030
  • Bosch Rexroth MSK040C-0600-NN-S1-UP0 Servo Motor
  • Bosch Rexroth VT3013 S36 R5 Circuit Board Card
  • Bosch Rexroth VT3000-36A Amplifier Card R90020298
  • Bosch Rexroth VPB40.3 IndraControl Module R911374113
  • Bosch Rexroth HCS02.1E-W0054-A-03-NNNN Converter with R911332574 Control Unit
  • Bosch Rexroth MHD071B-061-PG1-UN Servo Motor
  • Bosch Rexroth A2F5/60W-B3-S Piston Motor R909418904
  • Bosch Rexroth HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW IndraDrive Cs Converter
  • Bosch Rexroth 4WRPEH 6 C4B40P-2X/G24K0/A1M Proportional Directional Valve (0 811 404 647)