Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

The development process and background of industrial wastewater treatment

F: | Au:佚名 | DA:2023-11-22 | 685 Br: | 🔊 点击朗读正文 ❚❚ | Share:

Analysis of domestic and foreign sewage treatment development history, combined with China's development status of the 18th National Congress report pointed out: construction of ecological civilization, chemical enterprises towards green development, efficient development, low-carbon development direction transformation. Increase the intensity and requirements of pollution control and sewage treatment, and actively study and innovate to make our country have their own sewage treatment technology while constantly absorbing advanced technology of foreign sewage treatment. In the second half of 2015, the benefits of regional chemical enterprises began to decline, due to the national environmental protection policy strict requirements of enterprises to increase investment in environmental protection, overcapacity, sales decline, and higher prices of many reasons, the speed of industrial development has been affected to varying degrees. In the initial stage of transformation, the phenomenon of industrial development fluctuations is normal, we must adhere to the transformation. Continuous improvement.

2. Research status of industrial wastewater treatment

2.1 Process and principle of wastewater pretreatment The process treatment before biochemical treatment is called pretreatment. The biochemical system runs smoothly and the investment cost and operation cost are relatively small. However, it is not possible to treat wastewater by biochemical treatment alone, because industrial wastewater contains some active substances that can damage the ecosystem: Microorganisms and fungi have the presence of inhibiting and destructive substances, so in order to ensure the healthy operation of the biochemical system, a series of pretreatment must be carried out before the sewage enters the physicochemical section to adjust the biodegradability of the water quality and ensure the healthy operation of biochemical treatment.

There are two specific purposes of pretreatment: first, the organic or inorganic substances contained in the wastewater that have an impact on the active substances of the sludge in the biochemical tank are separated and removed to a certain extent or transformed into other harmless forms to protect the growth environment of the active substances of the sludge; The second is to reduce the chroma, salinity and suspended particles of the water before the biochemical section, adjust the COD load, and reduce the operating pressure of the biochemical section. Impurities in wastewater can be divided into suspended matter, colloids and dissolved matter according to particle size, and other large particles with particle size greater than 100 μm generally will naturally precipitate or separate from the water body. Colloids and fine particles and suspended matter need condensation, flocculation and coagulation methods to convert small particles into large particles, precipitate and separate from the water body.

1.1.1 Coagulation method and flocculation method Add coagulation agents containing positive ions or groups in wastewater. Using the principle of electrostatic induction, when adding a large number of positive ions or groups into colloids, a large number of positive ions will form a large number of colloidal particles between colloidal particles to coagulate and adsorb together to form macromolecular groups. It is easy to separate from the water body to achieve the purpose of water purification. The most used coagulants are aluminum sulfate, ferrous sulfate, alum, ferric chloride and so on. Flocculation method is the use of polymer coagulant in sewage to form a linear polymer polymer, polymer structure between the particles adsorption combination to form a relatively stable bridging effect, in this subunit between the continuous formation of bridging accumulation, condensation polymer material continues to grow, and finally reached saturation to form large particles of flocculant condensation together. Commonly used flocculants are polyacrylamide (PAM), polyiron (PE) and so on.

1.1.2 Coagulation method As the name suggests, the coagulation method is a method that combines coagulation and flocculation. Coagulation method is often applied in the process of industrial sewage pretreatment, the basic process is roughly the first to add coagulant (alum, ferrous sulfate and other agents) to the sewage, eliminate the electrostatic repulsion between colloidal particles, and then add flocculant (PAM, PE and other agents), so that the radius of the particles in the water increases, forming precipitation.

1.1.3 After the removal and treatment of sewage impurity particles into the iron carbon micro-electrolysis section Iron carbon treatment method is also called iron carbon micro-electrolysis method or iron carbon internal electrolysis method. Iron carbon micro-electrolysis uses the REDOX reaction of Fe2 + /Fe3 + in iron carbon micro-electrolysis. Iron carbon micro-electrolysis will form countless tiny units of iron carbon galvanic cells. The activity of active electrons is generated, which promotes the reactivity of organic matter in the sewage, makes the toxic and unsaturated substances in the sewage decompose and transform into other forms, reduces the load of chemical oxygen demand COD and biological oxygen demand BOD5, and lays the foundation for the normal operation of the subsequent treatment section. Iron carbon micro-electrolysis is an important means of industrial wastewater treatment. The iron carbon method has a remarkable effect on the treatment of industrial wastewater with toxic and high COD concentration. The reaction principle of the iron-carbon method is recognized as follows: under acidic conditions, iron-carbon fillers are added to water, forming a galvanic reaction between iron and carbon, forming a local unit of a large number of micro-current reaction areas, and promoting the reduction and oxidation of inorganic substances in sewage under the action of micro-current. The treatment effect of iron carbon micro-electrolysis is good in the actual sewage treatment, and the treatment effect has been recognized. The shortcomings of iron carbon method analysis: ① the price of iron carbon filler is not cheap, in the acidic conditions are decomposed, part of the incomplete reaction of iron filings and carbon will remain in the water, increasing the amount of sewage solid waste, blocking the instrument pipeline; ② Iron forms black iron sulfide in sulfur-containing wastewater under acidic conditions, which increases the color of the water, and a large number of iron ions enter the water to increase the salt content of the water.

  • BASLER ELECTRIC BE1-24/A1EF1JC1N0F / BE124A1EF1JC1N0F Overvoltage Relay
  • Basler Electric Solid State Protective Relay BE1-32R Style B2ED1PB0N0F
  • Basler BE3-51-3E1E1 9320000110 24VDC Overcurrent Relay
  • Basler UFOV 260A Underfrequency Overvoltage Module
  • Basler 50F4EA1PA0N0F Instantaneous Overcurrent Relay
  • Basler BE1-50 Instantaneous Overcurrent Relay
  • Basler BE1-32 Solid State Protective Relay
  • Basler SCP 250-G-60 VAR Power Factor Controller
  • Basler BE1-59N A5EE1KC0N0F Ground Fault Relay
  • Basler BE1-79A Reclosing Relay
  • Basler BE1-32R E1EA1OA0N0F Reverse Power Relay
  • Basler DCQA-103 DCQC104-1 CMX-7D Circuit Board
  • Basler SSR125-12 Static Regulator 918500102
  • Basler 90 17709 112 Regulator Control Board
  • Basler AVC63-4 AVC634 Voltage Regulator
  • Basler 9 1049 04 100 PC Board Control Module
  • Basler SR4A-2B03B3A Static Voltage Regulator
  • Basler SR8A-2B15B3A Static Voltage Regulator
  • Basler KR7FFX Static Regulator 840V
  • Basler EL200-7 Voltage Regulator 90-660VAC 7A
  • Basler PRP210-1 Reverse Power Relay 9056300102
  • Basler SSR 63-12 Static Regulator 600VAC
  • Basler 9289901106 Digital Board
  • Basler DECS100 Voltage Regulator DECS100A01
  • Basler Electric CEM-2020 Contact Expansion Module
  • Basler Electric BE3-25-1 C1 N4 Synchronizing Check Relay
  • Basler Electric ACA2000-50GM GigE Camera 2MP 50fps
  • Basler Electric ACA2240-20GMSYM GigE Camera Sony IMX264
  • Basler BE1-50G Ground Overcurrent Relay
  • Basler PRS250 Veri-Sync Relay
  • Basler MOC2199 Output Module
  • Basler UFOV 260A Underfrequency Overvoltage Module
  • Basler BE-15482-001 Control Module
  • Basler LSP4-7 Protective Relay
  • Basler SCP 250-G-60 VAR Power Factor Controller
  • Basler BE146N Negative Sequence Overcurrent Relay
  • Basler APR63-5 Automatic Voltage Regulator
  • Basler 9507900107 SR8A Retrofit Voltage Regulator
  • Basler BE1-320 Directional Power Relay
  • Basler KR7F Voltage Regulator 9116200100
  • Basler UFOV 260A Overvoltage Protective Module
  • Basler AEC63-7 Analog Excitation Controller
  • Basler 9992D90G01 Control Module
  • Basler 6966D22G01 Control Board
  • Basler 6965D40G01 Control Board
  • Basler BE1-50/51M-104 Overcurrent Relay
  • Basler BE1-BPR Programmable Breaker Relay
  • BASLER Electric SSR 125-9 1256 00 102 Static Voltage Regulator
  • Basler Electric MVC 112 Manual Voltage Control
  • Basler Electric 9321000102 Control Module
  • Basler Electric RA-70-MDCT7 Rectifier Assembly
  • Basler Electric ACA1300-60GM GigE Camera
  • Basler Electric 6427C85G01 Interface Board
  • Basler Electric 6965D05G01 Control Board
  • Basler Electric ACA2500-14UC Current Transducer
  • Basler Electric 9170206111 Protective Relay
  • Basler Electric BE1-11-G6D1M1J1P0E000 Protection Relay
  • Basler Electric BE1-50/51B-107 Overcurrent Relay
  • Basler 9121000106 Voltage Controller
  • Basler B3E-E1P-A0N0F Solid State Protective Relay
  • Basler 9121000106 Manual Voltage Control
  • Basler PRP320 Motor Pull-out Relay
  • Basler SSE-N 250-9KW Shunt Exciter Regulator
  • Basler BE1-50-51B-107 Overcurrent Relay
  • BASLER ELECTRIC MVC 108 MANUAL VOLTAGE CONTROL MODULE 9 0370 00 102
  • Basler BE1-59N-A7E-D1J-D0N0F Ground Overvoltage Relay
  • Basler BE1-46N-G1E-B8P-B0N0F Negative Sequence Overcurrent Relay
  • Basler BE1-951 Overcurrent Protection System
  • Basler Electric MOC2199 Motor Operated Potentiometer
  • Basler Electric BE1-60 Voltage Balance Solid State Relay B1FA1C1M1F
  • Basler Electric BE1-67N Directional Overcurrent Relay
  • Basler Electric PIA2400-17GM Interface Module
  • Basler Electric V6RAB Rectifier Module
  • Basler Electric BE1-32R Reverse Power Relay B2E E1R A0N1F
  • Basler Electric IFM-150 Firing Circuit Chassis 120V AC
  • Basler Electric IFM-102 Firing Circuit Chassis 120V AC
  • Basler Electric 9170206111 NSNP Control Module
  • Basler Electric SSR 63-12 Static Voltage Regulator
  • Basler UFOV 260A Overvoltage Protective Module
  • Basler SCA1300-32GM CCD Camera Lens Enclosure
  • Basler BA1-27 Under Voltage Relay
  • Basler 149D866G06 Control Board
  • Basler 9072300130 Power Supply Module
  • Basler CBS 305 Current Boost System
  • Basler BE1-60 Voltage Balance Relay
  • Basler Electric CBS 212 Current Boost System Sensing 120/240VAC 50/60Hz 10VA
  • Basler MVC-300 Manual Voltage Control Unit
  • Basler SSR125-12 Static Voltage Regulator 918500102
  • Basler SR32A2B05B3E Static Voltage Regulator
  • Basler Electric BE1-59N Ground Fault Overvoltage Relay
  • Basler Electric 9110000113 Excitation Module
  • Basler Electric 90-72300-114 Control Accessory
  • Basler Electric PRS-250 Protection Relay System
  • Basler Electric BE1-50/51M-109 Overcurrent Relay
  • Basler Electric SR4A1B10B3E Static Voltage Regulator
  • Basler Electric CBS 212 Current Boost System
  • Basler Electric SR32A2B05B3E Static Voltage Regulator
  • Basler Electric MOC2207 Motor Operated Potentiometer
  • Basler Electric SR4A1B05A3E Static Voltage Regulator
  • Basler Electric BE1-32R Power Relay B2EE1PA0N1F
  • Basler BEI-81 Underfrequency Relay
  • Basler CBS 212A Current Boost System
  • Basler SSR 63-12 Static Voltage Regulator
  • Basler DGC-2020 Digital Genset Controller
  • Basler BE1-32 Reverse Power Relay
  • Basler BE1-50/51B-207 Overcurrent Relay
  • Basler BE1-951 Overcurrent Protection System
  • Basler 9073800-103 Power Supply
  • Basler SCA1300-32FC CCD Camera
  • Basler 9073800-103 Power Supply
  • Basler SCA1300-32FC CCD Camera
  • Basler L304KC Protective Relay
  • Basler BE3-25-1S1N4 Time Overcurrent Relay
  • Basler 9032300113 Excitation Support System
  • Basler BE1-59N Ground Overvoltage Relay
  • Basler MVC-300 Manual Voltage Control Unit
  • Basler MOC2102 Potentiometer
  • Basler BE1-87G Generator Differential Relay
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric DECS 125-15-B2C5 Digital Excitation System
  • Basler Electric PLA2400-12GM Power Supply
  • Basler Electric BE1-50/51B-235 Overcurrent Relay
  • Basler Electric BE1-27/59 Undervoltage Overvoltage Relay
  • Basler Electric CEM-2020 Contact Expansion Module
  • Basler Electric BE1-32R Solid State Power Relay
  • Basler Electric BE1-700 Digital Generator Management Relay
  • Basler Electric BE1-59N Ground Fault Overvoltage Relay
  • Basler Electric BE10493002 Protection Module