Digital I/O driver (requires ADLINK dedicated driver, similar to PCMe-1432 DIO library).

Image acquisition driver (four-way analog acquisition, requires installation of dedicated SDK or driver, specific to the random CD).

Due to the EOS-2000 positioning simulation acquisition, its acquisition function is usually implemented through APIs or DirectShow filters provided by the manufacturer. Developers need to refer to the corresponding software development kit.

3.3 Key BIOS Settings

Startup sequence: If starting from a CF card, the CF needs to be set as the first boot device in the BIOS (CF is usually recognized as an IDE device).

Serial port mode: COM1/COM2 can switch between RS-232/422/485 in the Super I/O Configuration of BIOS, please ensure compatibility with external devices.

Power management: AT mode means that it automatically starts up after power failure, without the need to press the power button (suitable for unmanned operation).

Hardware monitoring: The BIOS can view CPU temperature, fan speed (if any), and voltage values for early fault warning.


Simulation video capture channel configuration and optimization

4.1 Four way NTSC/PAL input

The collection front-end of EOS-2000 supports standard composite video (CVBS) signals, and each channel can independently select the standard (NTSC or PAL). Attention should be paid when connecting the camera:

Use 75 Ω coaxial cable, with a recommended length not exceeding 100 meters (otherwise an amplifier needs to be added).

Ensure that the camera output impedance is 75 Ω and use DC coupling or AC coupling (according to the camera specifications).

If multiple cameras need to be synchronized, an external synchronization signal is required (the system does not have built-in genlock, and frame synchronization needs to be achieved through digital I/O or external synchronization sources).

4.2 Acquisition Resolution and Frame Rate

NTC: 720 × 480 @ 30 fps (or 29.97 fps)

PAL:720×576 @ 25 fps

When collecting data from four channels simultaneously, the system needs to process a data stream of approximately 4 × (720 × 576 × 25) ≈ 41 MB/s (YUV format). The Core2 Duo P8400 combined with the GM45 integrated graphics card is sufficient to handle it. However, if complex image processing algorithms are involved (such as edge detection and template matching), it is recommended to optimize the algorithm code and utilize multi-threaded parallel processing.

4.3 Image acquisition driver and API

ADLINK typically provides interfaces based on DirectShow or proprietary SDKs. Suggestions for development:

Use double buffering or ring buffering mechanism to avoid frame loss.

Set collection timeout to prevent program from hanging due to camera disconnection.

Using hardware triggering (through digital I/O input) to initiate data collection and achieve precise synchronization with external events.

16 way isolated digital I/O application and wiring guide

5.1 Electrical Parameters

Isolation voltage: 5.0 KV (to ensure that high voltage surges on industrial sites do not damage the system).

Input: Each channel can accept 5-24 VDC, and the logic high/low threshold needs to refer to the specific manual (usually 5 V threshold).

Output: Darlington transistor or MOSFET, with a current capability of approximately 100-500 mA per channel (please refer to the complete manual for details).

5.2 Typical Wiring Examples

Input: Connect proximity switches, photoelectric sensors, buttons, etc. Using an external 24V power supply, the signal is connected to the DI channel, and the common terminal is connected to DI-COM (choose common ground or common source according to NPN/PNP).

Output: Drive relay, indicator light, alarm. Note that the output is an open collector, and an external pull-up resistor or load power supply (VDD) should be connected in series with a current diode to protect the inductive load.

5.3 Interrupt function

The digital input channel can be configured as a Change Detection (COS) interrupt to capture high-speed signals (such as position triggers) and avoid CPU overhead caused by polling. The DIO interrupt registration function needs to be called in the software, and callback functions need to be written to handle events.


Common fault phenomena and troubleshooting steps

6.1 System not powered on/no display

Check if the power input is within the allowable range (DC 10-30 V or AC 100-240 V), note that there is no switch in AT mode, and it starts immediately upon power on.

Observe whether the front panel indicator light (if any) is on; If the power supply is normal but there is no display, check the VGA cable and monitor settings.

Attempt to clear the CMOS (motherboard jumper) and restore the default BIOS to eliminate configuration errors.

6.2 Simulated acquisition with no or abnormal images

No image: Check the camera power supply and video cable connection, and measure the presence of CVBS signal with an oscilloscope.

Image flicker or asynchrony: Check if the format setting (NTSC/PAL) is consistent with the camera. If NTSC is mistakenly set for PAL, scrolling or instability may occur.

Color abnormality: Check the white balance, saturation and other parameters of the acquisition card, or try to restore the default gain.

  • Metso Valmet BIU4 A413146 Binary Input Unit
  • Valmet AIU-8 Simulateur Board 421522-1a Analog Simulator
  • Valmet BIU8A Binary Input Unit 542803-3B M851222 M1
  • Valmet IQ Web Color DH Photoelectric Sensor A418182 2.04
  • Valmet A413200 AIU-8 Simulator Board 191151 421522-1A
  • Valmet Automation SCU M851006 System Control Unit Module
  • Valmet 857565/851565 Damatic Keyboard IP40 5V Operator Interface
  • Valmet A413077 FBC2 Module Rev 06 Field Bus Controller
  • Valmet DMU 2 PCB Module 545142-3A DM Data Management Unit
  • Valmet AIU16T PCB Card M851208 Analog Input Module
  • Valmet A413181 PLU Board
  • Valmet m851006 SCU Module
  • Valmet Metso 181226 Digital Input Module
  • Valmet AIU16T Analog Input Module - 16-Channel 65421466-2B MT924 V1.3
  • Valmet WIN3136875 Slide Clutch
  • Metso Valmet TIU61 A413111 Temperature Input Unit
  • Valmet MC12S Slitter Motor
  • Valmet A413139 AOH4 Board - Analog Output High Module
  • Valmet A409001 BIU85 Board
  • Valmet A413063 DMU Board
  • Valmet A413325 IPU I/O Power Unit
  • Valmet M851004 M2 CPU Module
  • Valmet IOP345 Digital Input Module
  • Metso Valmet A413215 Communication Board
  • Valmet DIFF-EL 80 M1 Transmitter
  • Valmet A413001 CPU Module
  • Valmet M899520 TDC-2 Module
  • Valmet A409001 BIU85 Board
  • Metso Valmet A413005 CPU Module
  • VALMET PUD 10 B Process Automation Rack with CPU SCU Module
  • Valmet A413091 GDU1 Board
  • VALMET M851006 M2 SCU Module
  • Lyngso Valmet Marine 990.896.000 Position Loop Card
  • Valmet Cooking Liquor Measurement 3417H
  • VALMET ABMB MT831 PCB Card
  • Valmet Automation A413325 IPU I/O Power Unit
  • Valmet Metso Consistency Transmitter Smart Pulp M2
  • VALMET METSO A413274 Connection Module
  • VALMET PI33S1KSA02RSA-ELI26 Switch
  • VALMET ND9103HN-CE07-K05 Intelligent Valve Controller
  • VALMET PMB 2R 16 Slot Backplane PCB Card
  • NELES VALMET A413135 AOU 4 Output Module
  • Metso Valmet A413345 FPU Power Unit
  • VALMET A413171 PIC Module
  • VALMET A413620 Repeater Module
  • Valmet M851521 Memory Card
  • Valmet DIFF-EL 140 M1 Transmitter
  • Valmet A413064 DMU Module
  • Valmet IOP371 I/O Bus Extender Module
  • Valmet Cooking Liquor Measurement 3400 Model 3417H
  • Metso Valmet A413043 CPU Module – Industrial Processor
  • Valmet BIU4 M851221 Binary Input Module
  • Valmet PMB 1S CPU SCU Rack Module
  • Valmet A413248 Controller Module
  • Valmet PDP601 Distributed Processing Unit
  • VALMET M851004 M2 CPU Printed Circuit Board Module
  • Metso Valmet A413045 Ver.05 CPU Module
  • Valmet A413181 Ver.05 PLU1 Board
  • Lyngso Valmet ATB16 Controller Board
  • VALMET AIU 16 Analog Input Unit 545100-3A/3B
  • VALMET PUD 10 B Power Supply PCB Rack Module
  • Valmet MS-50V/120V Bearing Unit
  • Valmet PDP603 Distributed Processing Unit – DPU Module
  • Valmet A413110 TIU Board – Terminal Interface Unit
  • Valmet S420154 I/O Backplane PCB – Printed Circuit Board
  • Valmet A413173 Industrial Control Module
  • Valmet A413044 CPU Module
  • Valmet A4IU1 Analog I/O Module
  • Valmet A413325 IPU Power Unit – PLC Module
  • Valmet M851002 CPU Module – Central Processing Unit
  • Valmet PUD10B Power Supply Board
  • Valmet K00990 Master CPU Electronic Assy
  • Valmet Metso IOP345 Input Module
  • Metso Automation T545215 Board
  • Valmet Metso IOP304 Input Module
  • Valmet 542844-6A SCU Module
  • Metso A413043 Ver.11 Valmet CPU Module
  • Valmet Automation BIU 8A Input Module
  • Metso A413044 Ver05 Valmet CPU Module
  • VALMET 542821-5A Control System Rack Module
  • Metso A413005 Ver.04 Valmet CPU Module
  • Valmet M851207 AIU16 Card
  • Valmet BIU8 Binary Input Unit
  • VALMET 547070-2B CPU Printed Circuit Board Module
  • Valmet Automation A413325 Power Module
  • VALMET AUTOMATION A413135 AOU4 Module
  • VALMET ACU A413165 Model 9 Analog Controller
  • VALMET AUTOMATION A413511-02 Slot Rack with I/O Backplane
  • Valmet A413148 BIE 4 Rev 08 Board
  • Valmet ATB16-4 Controller Board
  • Neles Automation BOR82 A413292 Processor Module
  • Valmet A413015 NCU Module – Network Control Unit
  • Valmet AIU 16 Analog Input Unit – M8512071
  • Metso Valmet A413091 GDU Board
  • Valmet M851565 Damatic Main Keyboard
  • Metso A413082 CPU Module
  • Valmet A403037 GDC – Graphics Display Controller
  • Valmet A413076 FBC Board
  • Valmet A413015 NCU Module – Network Control Unit
  • Valmet A413082 CPU Module
  • VALMET AUTOMATION A413620 Fieldbus Repeater
  • Valmet Metso IOP341R Positioner Module
  • Metso A413082 Ver.04 CPU Module
  • Valmet Metso MCA FT250/10 10 Inch Sensor
  • Valmet N0542 ABMB Printed Circuit Board
  • Valmet A413000 Ver.07 CPU Module
  • Valmet A413061 Ver.05 DMU Module
  • Valmet M851241 M1 BCU Binary Input Module
  • Valmet Automation NCU A413015 Circuit Board
  • Valmet A413046 Ver.06 CPU Module
  • Valmet A651B001 Panel Mount Keyboard
  • Valmet IQ Scanner A418080R Basis Weight Detector Head
  • Metso Valmet A413370 ESU Ethernet SCSI Unit
  • Valmet A413340 FPU Power Supply Unit
  • Valmet SKF GE 400/600 Spherical Plain Bearing
  • Valmet SCU PCB Card 542844-7B – System Control Unit
  • Valmet A413075 FBU Fieldbus Controller Module
  • Valmet A413171 PIC Card Binary Output
  • Valmet A413002 Ver.05 CPU
  • Valmet ABMB PCB Card – Industrial Control Board
  • Valmet PMB 2R 542821-4A PCB Card
  • Metso Valmet A413001 CPU Module
  • Metso Valmet A413050 RSU 6 Serial Controller Unit
  • Valmet ABMB MT241 Input Mother Board
  • Valmet DAMATIC M851565 Keyboard
  • Valmet A413075 Ver05 FBC Board
  • VALMET K14891 FLEXI-U Operating Terminal
  • VALMET AUTOMATION MKB2 DAMATIC Keyboard