If using an extension cord, make sure the length does not exceed 3 meters, otherwise the signal will attenuate.
Some systems require the installation of calibration software (such as Windows Touch Calibration) to ensure that it has been executed.
5.5 Overheating or abnormal shutdown
Check if the working environment temperature exceeds the specifications. Large models such as OM-320/430 only support 0-40 ° C.
Confirm that the ventilation opening is not obstructed and maintain a minimum distance of 30mm between the back of the monitor and the rear wall.
Check if the power adapter is in a well ventilated position, as overheating of the adapter may trigger protection.
Safety and maintenance precautions
Surface cleaning: Although the anti fingerprint coating is easy to clean, a soft cloth dipped in a small amount of neutral cleaner should be used to avoid damaging the coating with alcohol or strong solvents.
Electrostatic protection: The surface of the touch screen is made of glass, which has a certain hardness (7H or 3H), but it should be avoided from being scratched by sharp objects.
Waterproof and dustproof: The front panel is IP65, but the wiring ports and heat dissipation holes are not waterproof. Do not use unsealed interfaces in humid environments.
Battery warning (if the device contains RTC batteries): When replacing, use the same model, and dispose of waste batteries according to local regulations.
California Proposition 65: Products may contain substances such as lead and cadmium, but they comply with RoHS standards and are harmless when used normally.
Long term deployment recommendations
Spare parts management: For critical production lines, it is recommended to stock up on power adapters and USB touch cables of the same model for quick replacement in case of malfunctions.
Firmware update: Follow ADLINK's official release of new firmware (if available) to fix OSD or compatibility issues.
Regular calibration: The touch screen may shift after a period of use. Use the operating system calibration tool to recalibrate.
Environmental monitoring: If in high temperature or strong vibration environments, it is recommended to reinforce the installation and regularly check for loose screws.