ABB DCS 600 MultiDrive Thyristor Power Converters Series

F: | Au:FAN | DA:2025-04-01 | 823 Br: | 🔊 点击朗读正文 ❚❚ | Share:

ABB DCS 600 MultiDrive ABB DCS 600 MultiDrive Thyristor Power Converters Series


Electrical Specifications

Power supply parameters: The power supply of the electronic equipment has various specifications such as 115V/230V, 

which need to be matched with the corresponding transformer; 

the rated voltage of the armature circuit converter power supply and the excitation power supply unit need to satisfy the specific conditions, 

or else measures need to be taken. 

There is no special phase sequence requirement for the main power supply connection,

but an isolation transformer should be installed when using oscilloscopes to achieve potential isolation and avoid ground loops.


Motor-related parameters: 

The motor voltage and the excitation voltage are calculated differently for different models of DCS 600. 

For example, for the DCS 601, the maximum motor voltage U Amax = line voltage * 1.16 (2 - quadrant unit);

 the excitation voltage is calculated according to different standards for different excitation power supply units. 

In addition, parameters such as rated motor current and rated motor field current are involved for the relevant control and monitoring.


Control specifications

Control functions: Various control functions are available, e.g. the emergency stop function is set via binary input DI5 

and different stop modes and ramp times can be selected. 

The software is divided into two parts, SDCS - CON - 2 and SDCS - AMC - DC. 

The internal signal connections for data transfer via automatic and programmable channels cover the transfer of a wide range of parameters and the realisation

of functions.

Parameter setting: Numerous parameters are used to set and adjust the operating status  of the device, such as setting the rated value parameters (rated line voltage, rated power converter current, etc.), 

control mode parameters (selection of modes such as speed control, torque control, etc.), 

and controller parameters (parameter adjustment of current controllers, speed controllers, EMF controllers, etc.).


Communication specifications

Communication interface and protocol: 

When communicating with a variety of devices, there are requirements for hardware connection and software settings. 

For example, to communicate with APC, YPQ112B board is used, cable length is 0.2-20m,

 plastic optical fibre, and specific parameters are set by software; to communicate with Profibus, NPBA02 board is used, 

and corresponding parameters need to be set by software, and attention should be paid to the data updating and consistency checking before communication.

Communication Parameters: The parameter settings are different in different communication modes, 

such as module type, mode, driver number, bit rate and other parameters for Profibus communication; 

Modbus PLUS communication requires setting module type, mode, driver number and various data-related parameters.


Other specifications

Safety related: There is an emergency stop button, and the operation should follow the relevant safety regulations. 

Electrostatic discharge may damage the equipment, should take appropriate protective measures.

Environmental conditions: equipment storage and transport to meet certain environmental conditions,

 operation of the environment temperature, humidity, altitude and other requirements to ensure the normal operation of the equipment .

Technical characteristics

Diversified control functions: support a variety of control modes, such as speed control, 

torque control and excitation mode, which can meet the needs of different industrial applications. 

With automatic adjustment function, such as current controller and excitation current controller can be automatically tuned, 

which can adapt to different motor and load characteristics and optimise the control performance. 

The control mode and characteristics can be flexibly adjusted by setting different parameters, such as setting the speed feedback mode (analogue tacho, encoder or EMF signal), adjusting the controller parameters (KPS, TIS, etc.) to optimize the control response.


Strong communication capability: it can communicate with various devices, such as APC, AC 70, AC 80, FCI, Profibus, Modbus PLUS, CS 31, etc., adapting to different industrial automation system architectures. Adopting plastic optical fibre and other communication media, the transmission speed is fast, for example, the transmission speed can reach 4Mb when communicating with AC 70, AC 80 and so on. Flexible communication settings, different devices need to set the corresponding parameters for communication, such as node type, driver number, communication protocol-related parameters, etc., to ensure stable communication.

Perfect protection mechanism: It is equipped with various fault detection and protection functions, 

which can detect over-current, over-voltage, under-voltage, over-speed, ground fault, motor overload, 

overheating and other faults, and send out signals in time to take corresponding protection measures, 

such as cutting off circuits, alarms, etc., to protect the safety of equipments and personnel. 

  • Basler D90 96801 100 PCB Card
  • Basler XR2002F Voltage Regulator (110 VAC, 48-480 Hz)
  • Basler SR8A-2B14B3A Regulator
  • Basler 9561500100 Module
  • Basler DECS-400 BE1-11 System
  • Basler DECS-100-B15 Excitation Control
  • Basler SCP 210 Frequency Controller
  • Basler SR4A-2B15B3A Static Voltage Regulator
  • Basler BE1-32R Power Relay
  • Basler PIA2400-17GM Power Interface Adapter
  • Basler MVC 232 Manual Voltage Control Module
  • Basler SSR 32-12 Static Voltage Regulator
  • Basler 5MW AVR Generator Voltage Regulator
  • Basler VR63-4B Voltage Regulator
  • Basler DECS-100-A05 AVR for Engine Generator
  • Basler DECS-100-B15 Automatic Voltage Regulator
  • Basler BE1-32R Directional Power Relay
  • Basler BE1-87B Differential Relay
  • Basler UFOV 260A Protective Module
  • Basler 9-2614-02-100 PCB Rev M
  • Basler DECS-100-B15 Digital AVR
  • Basler 9284900103 PS DECS-400N
  • Basler D4N3H1U Intertie Protection
  • Basler DECS-100-B15 A15 AVR
  • Basler KR4F Voltage Regulator
  • Basler BE26434 T14 Transformer
  • Basler SR8A-2B15B3A Regulator
  • Westinghouse 774B472A12 AR Relay
  • Basler DECS-100-B15 AVR
  • Basler XR2002F Regulator 110V
  • Basler SR125-E Static Regulator
  • Basler SSR 125-12 Regulator
  • Basler MOC2599 Motor Pot
  • Basler BE1-DFPR Feeder Relay
  • Basler CBS 305 Current Boost
  • Basler BE1-25 AutoSync
  • Basler MVC 300 Voltage Control
  • Basler BE3-25A AutoSync
  • Basler KR7FF Static Regulator
  • Basler 90-49000-100 Regulator
  • Basler 880 kVA Dry Type Transformer Specs
  • Basler Electric BE1-25 Sync-Check Relay Specs
  • Basler SSR 125-12 Voltage Regulator Specs
  • Basler Electric BE1-851 Overcurrent Relay Review
  • Basler Electric 149D930G02 Control Sub-Assembly
  • Basler Electric BE1-81O/UT Frequency Relay Specs
  • Basler Electric BE1-51/27C Overcurrent Relay
  • Basler Electric 149D956G02 Industrial Component
  • Basler Electric BE1-51A Overcurrent Relay Specs
  • Basler Electric BE1-40Q Loss of Excitation Relay
  • Basler DECS-200 Excitation Control System
  • Basler DECS-200 Voltage Regulator 56-277V AC / 125V DC
  • Basler BE1-87T Transformer Differential Relay
  • Basler RDP-110-S1 Protection Relay
  • Basler BE1-700V Digital Protective Relay
  • Basler BE1-951 Overcurrent Protection System
  • Basler DECS-300 Digital Excitation Control
  • Basler DECS-200 Digital Excitation Control
  • Basler DECS-200-1C Excitation Control System
  • Basler DECS-200-1L Digital Excitation Control
  • Basler Electric BE1-GPS Generator Protection System
  • Basler Electric DECS-200-1C Digital Excitation Controller
  • Basler Electric DECS125-15 Excitation Control with Power Module
  • Basler Electric BE1-87G Differential Relay
  • Basler Electric BE1-11 Protection System I5A3M2P2N0EA00
  • Basler Electric DECS-200-1C Excitation Control System
  • Basler Electric BE1-11g Generator Protection Relay
  • Basler Electric DECS 125-15-B2C1 V2.0.9 Excitation Control
  • Basler Electric BE1-81O/UT3ED1JA7N2F Frequency Relay
  • Basler Electric BE1-81O/UT3EE1YB7N1F Frequency Relay
  • Basler Electric DECS-200-1L Digital Excitation Control System
  • Basler DECS125-15-B2C1 Excitation Control
  • Basler 9507900205 SSR Retrofit Voltage Regulator
  • Basler BE2000E Digital Voltage Regulator
  • Basler BE1-GPS Generator Protection System
  • Basler DECS-250-CN1CN1N Digital Excitation Control
  • Basler DGC-2020 Genset Controller
  • Basler BE1-81O UT3ED1LA7N0F Frequency Relay (Variant)
  • Basler BE1-81O UT3EE1YA9S0F Frequency Relay (Variant)
  • Basler BE1-81O Over/Under Frequency Relay
  • Basler DECS125-15 Digital Excitation Control
  • Basler Electric BE1-951 Overcurrent Protection System
  • Basler Electric BE1-700V Digital Protective Relay
  • Basler Electric APR63-5 Automatic Voltage Regulator
  • Basler Electric BE1-851 Overcurrent Protection System
  • Basler Electric DECS-250-LN1SN1N Excitation Control
  • Basler Electric BE1-87T Transformer Differential Relay
  • Basler Electric DECS-200-1L Excitation Control System
  • Basler Electric 9310300100 DECS-300 Excitation Control
  • Basler Electric SSE-N 125-4.5KW Shunt Exciter Regulator
  • Basler Electric DGC-2020HD-5NS1DNSBA Genset Controller
  • Basler Electric BE1-81-O/UT3EE1JB7N1F Frequency Relay
  • Basler Electric BE1-81T1EE1WA0N1F Frequency Relay
  • Basler Electric BE1-25M1EA6PN5R1F Sync-Check Relay
  • Basler Electric BE1-GPS Generator Protection System
  • Basler Electric DECS-250-LN1SN1N Excitation Control Rev V
  • Basler Electric DECS-250-CN2CN1N Excitation Control
  • Basler Electric BE1-50/51B-207 Overcurrent Relay
  • Basler Electric DECS-300-C0N0 Excitation Control System
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric DECS-250-LN1CN1N Excitation Unit
  • Basler Electric DECS-250 LN2SA1D Excitation Unit Specs
  • Basler Electric BE1-87T Transformer Relay Review
  • Basler Electric BE1-11 Protection System
  • Basler Electric BE1-GPS100-E4N1H1N Protection System
  • Allen-Bradley 442G-MABH-R Safety Module
  • Beckhoff CX1030-0111 PLC Assembly Profile
  • FANUC IC693CPU364 PLC Module
  • Orange Denmark Type 200816 220 PLC Specs
  • OMRON C200H-SNT31 Sysmac PLC Module
  • Allen Bradley 20AB022A3AYNANC0 PowerFlex 70
  • OMRON C200HW-PCU01 Position Control Unit
  • ABB AO845A-eA Analog Output Module
  • OMRON CJ1M-CPU22 CPU Unit
  • Allen Bradley 100-E265ED11 Contactor
  • Honeywell 51304511-100 Interface Module
  • SOLEXY BXF3S0101N0018 Gateway Module
  • OMRON CJ2H-CPU65 CPU Unit
  • Automation Direct GS2-45P0 AC Drive
  • M68-2000 2-Axis Motion CNC Controller
  • OMRON CJ1M-CPU11 V3.0 PLC CPU Unit
  • OMRON CJ1W-NC413 4-Axis Positioning Controller
  • OMRON 3G2A3-PRO16 Programming Console HMI
  • Siemens 3VT8440-2AA04-2GA2 Molded Case Circuit Breaker
  • Siemens 3RT5045 Contactor Series
  • OMRON C200HS-CPU01-E SYSMAC PLC Controller
  • OMRON C500-NC103-E Positioning Control Unit
  • OMRON CJ1W-TC001 Temperature Control Unit