Common applications include PCB AOI (Automatic Optical Inspection), flat panel display inspection, solar cell sorting, print quality inspection, traffic monitoring, robot guidance, etc. Coaxlink's high bandwidth and flexible triggering characteristics make it an ideal front-end for these fields.
System integration precautions
Power supply: It is necessary to connect the auxiliary power supply (6-pin PEG), otherwise PoCXP cannot supply power and its I/O output capability is limited.
Cable length: Maximum 40 meters at CXP-12 speed, if the distance is longer, reduce the speed to CXP-6 or CXP-3.
Cooling: The active fan model should ensure proper ventilation of the chassis, while the passive cooling (LH model) should provide sufficient airflow (150 LFM).
Multi card installation: Multiple cards within the same PC need to be connected through C2C Link ribbon cables (length ≤ 60cm), and across PCs, InterPC adapters and shielded twisted pair cables need to be used.
Software configuration: Use GenICam Browser to confirm the camera connection status, configure the trigger source and exposure parameters; Monitor key events using Memento to ensure accurate triggering timing.