In the lifecycle management of industrial automation production lines, the HMI (Human Machine Interface) of old equipment is often the first component to face elimination or shutdown. When the character terminals or bulky thin film button panels on early equipment showed signs of aging and button failure, and original spare parts were no longer available, engineers urgently needed to find a replacement product that could perfectly adapt to the original control cabinet openings, seamlessly integrate with existing PLC communication protocols, and have operating habits that would not make production line workers feel unfamiliar. The EXOR UniOP ePAD05 and ePAD06 compact button HMI panels are designed to address this pain point.
These two panels are positioned as entry-level HMIs, but come standard with complete digital data entry capabilities. They are not only an ideal upgrade replacement for old models such as ePAD03/04, but also an excellent choice for replacing various discontinued low-end text operation screens (such as early Siemens, Mitsubishi, or Omron simple terminals). This article will break away from the manual style listing and provide you with a highly practical and in-depth technical guide from the dimensions of hardware interfaces, communication topology, configuration logic, and on-site replacement and troubleshooting.
Hardware architecture and physical compatibility
When implementing replacement projects, matching physical dimensions is the first step. The front panel size of ePAD05 and ePAD06 is 149 x 109 mm, and the control cabinet opening size is 136 x 96 mm, supporting a maximum of 5mm thick panel installation. Its installation depth (opening depth) is only 53 mm, which greatly alleviates space pressure for old control cabinets with extremely crowded internal wiring. The front of the panel provides an IP65 protection level, which can effectively resist water splashes and dust in industrial sites.
Differences in display and interaction logic:
Unlike the current mainstream touch screens, the ePAD series adopts a button based operation. It is equipped with a monochrome LCD display screen with a resolution of 120x32 pixels (effective display area 70x21mm) and supports a 4-row x20 column character display mode. For experienced operators who are accustomed to traditional text screens, this display logic has no learning threshold.
The front panel provides 9 user-defined function keys with slide in legends and 10 system keys. The design of this physical button is far more reliable than capacitive touch screens in harsh environments such as food processing and metal processing when operated with gloves. In addition, the panel is equipped with 10 user programmable LED indicator lights and 4 system LEDs, which can intuitively display the operation, alarm, and communication status of the device.
Font and character support:
This series supports scalable fonts and 256 user-defined characters. When replacing old equipment, it is often necessary to display special symbols or non-standard characters. The powerful font library capability ensures that whether displaying Arabic numerals or special process symbols, they can be presented clearly.

Communication topology and driver compatibility
The biggest obstacle to replacing old equipment often lies in communication protocols. EPAD05/06 demonstrates strong industrial level inclusivity in this regard:
Dual driver communication:
This is the core killer of the panel. The panel supports running two sets of communication drivers simultaneously through the PLC ports at the bottom (RS-232, RS-422, RS-485). For example, it can read the operating frequency of the frequency converter through RS-485 while forwarding the data to the main control PLC through RS-232.
Massive driver library:
The UniOP system has built-in communication drivers for over 130 types of industrial equipment. Whether it is old Modbus RTU devices or specific brand specific protocols (such as early Allen Bradley DF1, Siemens 3964R, etc.), corresponding entries can usually be found in the driver library without the need to write additional underlying communication code.
Fieldbus and Ethernet Expansion:
If the original serial communication speed cannot meet the data refresh rate of the new process, the panel reserves an auxiliary port (Aux port). By inserting optional communication modules, it can seamlessly connect to fieldbus such as Profibus DP, DeviceNet, CANopen, Interbus, and even support Ethernet connections. In conjunction with the UniNet network, data sharing between server and client architectures can also be achieved.
Configuration software and data management
This panel is configured using UniOP Designer software. As a classic development tool of EXOR, it is adept at handling small and medium-sized projects:
Dynamic graphics and formulas: not only support numerical and textual values, but also display bar charts. Providing a 16KB recipe storage area is an essential feature for equipment that requires frequent switching of processing parameters, such as injection molding machines and packaging machines.
Alarm and Event: Supports up to 1024 alarms and 256 event lists. Combined with a hardware RTC (real-time clock) with battery backup, it can accurately record the timestamp of device failures.
Security mechanism: Supports 8-level password protection. When replacing old equipment, it is easy to set access permissions for key process parameters (such as PID settings) to prevent unauthorized personnel from making mistakes.
Macro command editing: Built in keyboard macro editor, which can trigger specific logic controls through key actions to achieve simple local data processing.
On site replacement and common troubleshooting guide
After completing mechanical drilling and electrical wiring, engineers usually face the following types of problems that need to be investigated according to the following logic:
1. Black screen or no display when powered on
Troubleshooting: The power supply voltage requirement for the panel is 18 to 30 VDC (typical value 24V, maximum power consumption 0.25A). Firstly, measure the terminal voltage and confirm that the positive and negative poles are not reversed. If the power supply is normal, check if the screen contrast setting is set to the lowest (software adjustable); If the backlight is bright but there are no characters, it is usually because the configuration file has not been downloaded or the download is incomplete.
2. Communication unresponsive or data disordered
Troubleshooting: This is the most common fault in replacement engineering. Firstly, verify the communication parameters (baud rate, data bits, stop bits, parity bits) and check if the baud rate setting matches the old device (note: the baud rate of some old devices may not be the standard value). Secondly, if using RS-485/422, focus on checking whether the A/B or TX/RX wires are reversed due to aging old cables. Special attention: If two devices are connected at the same time, it is necessary to check whether the port allocation in the dual drive settings is correct to avoid bus conflicts.
3. Button failure or drift
Troubleshooting: ePAD uses thin film buttons, which are prone to aging or corrosion due to prolonged pressing. If a button completely malfunctions, it is usually necessary to replace the front panel film. In addition, check if the "slide in legend" plastic sheet of the button is installed properly. If there are foreign objects stuck, it can also cause the button to fail to rebound.
4. Data loss or time reset after power outage
Troubleshooting: The panel relies on an internal CR2430 (3V 270mA lithium manganese battery) to maintain the RTC clock and some user data during power outages. The battery is designed to be replaceable by the user. If the device frequently reports time errors or formula loss, it is necessary to replace the battery while the system is powered on to prevent data loss in an instant. When replacing, use batteries of the same model or compatible with the operating temperature to avoid leaking and damaging the motherboard.
5. Communication interruption caused by interference
Troubleshooting: As the panel is usually installed on the front panel of the equipment, it is very close to the frequency converter and high-power motor. If the communication line does not use twisted pair shielded wires, or if the shielding layer is not grounded at one end, it is highly susceptible to electromagnetic interference (EMI) that can cause errors in bus data frames. Strictly follow the EN 61000-6-2 (anti-interference) standard for wiring.