Hirschmann RSB20 Switch Deployment and Redundant Configuration

F: | Au:FANS | DA:2026-06-22 | 372 Br: | 🔊 点击朗读正文 ❚❚ | Share:

Engineering Deployment and Redundancy Management Practice of Hirschmann RSB20 Series Industrial Ethernet Switch

Introduction: Evolution from Foundation to Flexibility

The demand for reliability and flexibility in industrial networks is increasing day by day. Hirschmann has launched the RSB20 family based on the successful RS20 Basic, which not only inherits classic features such as fanless design, redundant power supply, and DIN rail installation, but also introduces SFP (Small Form Factor Pluggable) optical module support, wide temperature expansion options, and enhanced Ring Manager functionality. These innovations enable RSB20 to adapt to diverse scenarios ranging from standard workshops to extremely cold outdoor environments, from simple star shaped to complex ring networks. This article will systematically review the hardware selection, installation grounding, electrical connections, SFP operation, LED diagnosis, and initial configuration of RSB20 based on official technical documents, to help engineers efficiently complete deployment and fully utilize its redundancy and safety management features.


Chapter 1 Analysis of Product Family and Port Combination

1.1 Model Code and Interface Type

The RSB20 device provides two basic skeletons, 8-port or 9-port, and its complete model follows clear coding rules. The meanings of key fields are as follows:

Basic port count: 0800 represents 8 10/100Mbit/s ports; 0900 represents 9 physical interfaces (some of which are fiber optic or SFP slots).

Media identification: T1T1 represents all RJ45 twisted pair ports; M2M2 represents 6 TP ports and 2 multimode fiber DSC ports; S2S2 consists of 6 TP+2 single-mode optical fibers; ZZZ6 provides 6 TP+3 SFP slots, allowing users to insert optical modules as needed.

Mixed variants: such as 0900M2TT (8 TP+1 multi-mode FX), 0900VVM2 (6 TP+2 single-mode+1 multi-mode), etc., to meet the needs of different distances and costs.

Key selection points: Both fiber optic ports (DSC or SFP) support the 100BASE-FX standard, but multimode (MM) and single-mode (SM) cannot be mixed, and LH long-distance modules can only be docked with the same type.

1.2 Extended Temperature Range Options

The manual lists two types of operating temperatures: the standard model ranges from 0 ° C to+60 ° C, while the wide temperature model with a -40 ° C to+70 ° C label at the end of the model is suitable for cold regions or outdoor cabinets. It should be noted that if SFP modules without the "EEC" suffix are used, the actual operating temperature limit of the equipment will be reduced to+60 ° C. When selecting the project, it is necessary to check the compatibility of the accessories.

1.3 Mechanical dimensions and installation space

The 8-port full TP model (RSB20-0800T1T1) measures 47mm (width) x 131mm (height) x 111mm (depth) and weighs 400g.

The width of other variants containing fiber optic or SFP has been increased to 74mm, with a weight of 410g.

Cooling distance: vertically installed, leaving at least 10cm gap in front, back, left and right of ventilation holes; When installed in residential or office areas, it must be placed in cabinets that comply with EN 60950-1 fire protection requirements.


Chapter 2 Mechanical Installation and Grounding Standards

2.1 DIN rail installation steps

Hang the hook above the back of the device onto the upper edge of a 35mm DIN rail (compliant with DIN EN 60175).

Press the lower part of the device towards the guide rail until the bottom spring latch clicks and locks.

After installation, gently pull the equipment to confirm that it is securely fixed.

Disassembly: Insert a flathead screwdriver horizontally into the locking groove at the bottom of the housing, pull it vertically downwards to unlock, and lift the device upwards at the same time.

2.2 Functional Grounding (FE)

There is an independent grounding screw located in the lower right corner of the front panel of the device, which must be connected to the system grounding bar using a copper wire with a cross-sectional area of not less than 1.0mm ². The shielding layer of the shielded twisted pair cable has been internally connected to the front panel, but functional grounding is the foundation for ensuring personnel safety and electromagnetic compatibility (EMC) performance and cannot be omitted.

Chapter 3 Electrical Connection between Power Supply and Signal Terminals

3.1 Definition of 6-pin pluggable terminal block

Similar to RS20 Basic, RSB20 uses a 6-pin terminal block to carry power and fault contacts, with pin definitions as follows (refer to Figure 2 in the manual):

Pin symbol function

1+24V (P1) power input 1 positive pole (DC) or AC phase line

2 0V power input, 1 return line/AC neutral line

3 FAULT signal contacts (normally closed relay)

4 FAULT signal contact common terminal

5 0V power input 2 loop/AC neutral line

6+24V (P2) power input 2 positive pole (DC) or AC phase line

3.2 Redundant power supply and voltage range

DC: Rated from 12V DC to 24V DC (maximum 9.6V to 32V DC, but UL certification only applies to 12-24V), with internal decoupling of the two inputs and automatic selection of higher voltage power supply.

  • Basler DECS-250-CGCM-LN2SA1C Digital Excitation Control System
  • Valmet Automation PLC Module A413171
  • Valmet Automation 542852-3A Rack-Mount Cross Connect Panel
  • Valmet Marine Damatic M851565 Main Keyboard
  • Valmet TIU 6 Printed Circuit Board A413110
  • Metso Valmet U4440253V1.1 RMI CPU 300
  • Metso Valmet A413016 Ver.12 NCU2
  • Valmet M851565 Damatic Keyboard
  • Valmet ATB16-4 16 Channel Relay Card
  • Valmet Metso A413331 SPU Power Supply
  • Valmet PUD 10B Automation Control Rack
  • Valmet MT917 ABMB DMU PCB I/O Module
  • Valmet M851565 Damatic Keyboard Mkb2
  • Valmet EDS-518A-MM-SC Ethernet Gateway
  • Valmet 542836-6A PCB Card
  • Valmet ATB16-4/2 Terminal Board 9144047
  • Valmet ATB16-4 Controller Board 0-50°C 4-20mA Analog Output
  • Valmet 542852-3A Slot Rack Chassis Module
  • Valmet A413026 Ver.M1 FBC Board
  • Valmet IQ Basis Weight SH Sending Assembly A418081
  • Valmet PMB 2R Monolithic Backplane 8-Slot PCB 542821-5A and -5B
  • Valmet ATB16-4 16-Channel Relay Card Controller Board 22195028
  • Valmet Diff-EL SL6NK227SF0 Pressure Transmitter 0-380 mBar
  • Valmet A413110 TIU6 Board Ver.M1
  • Neles Automation A413278 Control Module
  • Valmet BCUTB Terminal Module 10101006 11091002
  • Valmet Senso 160 Measuring Station Display 160.2
  • Valmet AIU 1A Analog Input Unit M851245
  • Valmet IQ Web Caliper Sensor A420734
  • Valmet M851040/M8510401 Memory Board
  • Valmet AN35S1MC02RA Valve
  • Valmet M851121 M2 Cross Connect Panel
  • Valmet AIU-8 Simulator Board 421522-1A
  • Metso BIU 82 D200533 Binary Input Unit
  • Valmet M851121 M2 Module Rack
  • Valmet A413383 PC Board Module
  • Valmet N0542 NO54 ABMB PCB - 545200-3A Board
  • Valmet Metso IOP304 Input Module 181503
  • Valmet PDP601 Distributed Processing Unit 181585
  • Valmet A413084 CPU Board - Processor Module for Automation Systems
  • Valmet AIU 16T Analog Input Module M8512081 M1
  • Valmet AIU 16 Analog Input Module 545100-3A and 545100-3B
  • Metso Valmet BIU4 A413146 Binary Input Unit
  • Valmet AIU-8 Simulateur Board 421522-1a Analog Simulator
  • Valmet BIU8A Binary Input Unit 542803-3B M851222 M1
  • Valmet IQ Web Color DH Photoelectric Sensor A418182 2.04
  • Valmet A413200 AIU-8 Simulator Board 191151 421522-1A
  • Valmet Automation SCU M851006 System Control Unit Module
  • Valmet 857565/851565 Damatic Keyboard IP40 5V Operator Interface
  • Valmet A413077 FBC2 Module Rev 06 Field Bus Controller
  • Valmet DMU 2 PCB Module 545142-3A DM Data Management Unit
  • Valmet AIU16T PCB Card M851208 Analog Input Module
  • Valmet A413181 PLU Board
  • Valmet m851006 SCU Module
  • Valmet Metso 181226 Digital Input Module
  • Valmet AIU16T Analog Input Module - 16-Channel 65421466-2B MT924 V1.3
  • Valmet WIN3136875 Slide Clutch
  • Metso Valmet TIU61 A413111 Temperature Input Unit
  • Valmet MC12S Slitter Motor
  • Valmet A413139 AOH4 Board - Analog Output High Module
  • Valmet A409001 BIU85 Board
  • Valmet A413063 DMU Board
  • Valmet A413325 IPU I/O Power Unit
  • Valmet M851004 M2 CPU Module
  • Valmet IOP345 Digital Input Module
  • Metso Valmet A413215 Communication Board
  • Valmet DIFF-EL 80 M1 Transmitter
  • Valmet A413001 CPU Module
  • Valmet M899520 TDC-2 Module
  • Valmet A409001 BIU85 Board
  • Metso Valmet A413005 CPU Module
  • VALMET PUD 10 B Process Automation Rack with CPU SCU Module
  • Valmet A413091 GDU1 Board
  • VALMET M851006 M2 SCU Module
  • Lyngso Valmet Marine 990.896.000 Position Loop Card
  • Valmet Cooking Liquor Measurement 3417H
  • VALMET ABMB MT831 PCB Card
  • Valmet Automation A413325 IPU I/O Power Unit
  • Valmet Metso Consistency Transmitter Smart Pulp M2
  • VALMET METSO A413274 Connection Module
  • VALMET PI33S1KSA02RSA-ELI26 Switch
  • VALMET ND9103HN-CE07-K05 Intelligent Valve Controller
  • VALMET PMB 2R 16 Slot Backplane PCB Card
  • NELES VALMET A413135 AOU 4 Output Module
  • Metso Valmet A413345 FPU Power Unit
  • VALMET A413171 PIC Module
  • VALMET A413620 Repeater Module
  • Valmet M851521 Memory Card
  • Valmet DIFF-EL 140 M1 Transmitter
  • Valmet A413064 DMU Module
  • Valmet IOP371 I/O Bus Extender Module
  • Valmet Cooking Liquor Measurement 3400 Model 3417H
  • Metso Valmet A413043 CPU Module – Industrial Processor
  • Valmet BIU4 M851221 Binary Input Module
  • Valmet PMB 1S CPU SCU Rack Module
  • Valmet A413248 Controller Module
  • Valmet PDP601 Distributed Processing Unit
  • VALMET M851004 M2 CPU Printed Circuit Board Module
  • Metso Valmet A413045 Ver.05 CPU Module
  • Valmet A413181 Ver.05 PLU1 Board
  • Lyngso Valmet ATB16 Controller Board
  • VALMET AIU 16 Analog Input Unit 545100-3A/3B
  • VALMET PUD 10 B Power Supply PCB Rack Module
  • Valmet MS-50V/120V Bearing Unit
  • Valmet PDP603 Distributed Processing Unit – DPU Module
  • Valmet A413110 TIU Board – Terminal Interface Unit
  • Valmet S420154 I/O Backplane PCB – Printed Circuit Board
  • Valmet A413173 Industrial Control Module
  • Valmet A413044 CPU Module
  • Valmet A4IU1 Analog I/O Module
  • Valmet A413325 IPU Power Unit – PLC Module
  • Valmet M851002 CPU Module – Central Processing Unit
  • Valmet PUD10B Power Supply Board
  • Valmet K00990 Master CPU Electronic Assy
  • Valmet Metso IOP345 Input Module
  • Metso Automation T545215 Board
  • Valmet Metso IOP304 Input Module
  • Valmet 542844-6A SCU Module
  • Metso A413043 Ver.11 Valmet CPU Module
  • Valmet Automation BIU 8A Input Module
  • Metso A413044 Ver05 Valmet CPU Module
  • VALMET 542821-5A Control System Rack Module
  • Metso A413005 Ver.04 Valmet CPU Module
  • Valmet M851207 AIU16 Card
  • Valmet BIU8 Binary Input Unit
  • VALMET 547070-2B CPU Printed Circuit Board Module
  • Valmet Automation A413325 Power Module
  • VALMET AUTOMATION A413135 AOU4 Module