Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

Woodward MSLC-2 ™ Master Synchronizer and Load Control

F: | Au:FAN | DA:2025-08-05 | 914 Br: | 🔊 点击朗读正文 ❚❚ ▶ | Share:


Woodward MSLC-2 ™  Master Synchronizer and Load Control

Product description

Woodward's MSLC-2 ™ Compared to DSLC-2 ™ Control coordination can provide synchronization and load control between public utilities and contact circuit breakers. The MSLC-2/DCLC-2 combination operates through an Ethernet communication network and can control simple or complex generator system applications. This combination (32 DSLC-2 and 16 MSLC-2) provides multi unit, multi segment, utility, and tie line power management for complex power systems, while always providing non impact load transfer with utilities and controlling the import and export levels of the entire plant.

MSLC-2 control combines synchronization, dead bus closure, utility/tie line load sensors, basic load control, inlet and outlet control, reactive power (VAR), power factor, and main process control in a powerful component.


MSLC-2 provides phase matching, slip frequency synchronization, and voltage matching on utility or contact circuit breakers. The MSLC-2/DCSLC-2 combination can handle multiple utility connections, with a maximum of 8 bus segments in one application.

The load sensor and load control of MSLC-2 can detect true RMS power and provide shock free loading and unloading on the utility grid. Basic load, import and export, process and utility unloading modes control the kilowatt power between different power sources, while controlling reactive power, VAR and power factor. Reactive power will gradually increase and decrease to achieve the smoothest load trading between power grids.

MSLC-2 communicates via Ethernet (now providing redundant Ethernet) to control active and reactive loads for utilities through generators equipped with DSLC-2.

The contact circuit breaker mode allows synchronization between multiple generator systems. After connecting each section, power can be measured across the connecting line, but load control does not work when the connecting circuit breaker is in operation.

Product Features

One MSLC-2 can provide main control for up to 32 DSLCs and an additional 15 MSLC-2 in the system.

Two dedicated Ethernet lines are used for precise system communication between all DSLC-2 and MSLC-2 on the system.

Ethernet Modbus TCP, used for remote control and monitoring of PLC or DCS systems.

Redundant Ethernet communication improves reliability.

The main MSLC-2 is redundant, and communication loss with the designated MSLC-2 main device will initiate control switching to the next designated MSLC-2 main device.

MSLC-2 hardware can be adjusted for various applications.

Slip frequency or voltage phase matching synchronization is fully selectable, with dead bus options in both directions, providing ample flexibility for tie line and main tie line main applications.

Integrate functions into one device without connecting redundant sensors (such as PT, CT, and MOP) to various modules (such as load sensors and synchronizers).

Digital signal processing enables MSLC-2 to resist power line distortion and harmonics.

Three phase true RMS power detection can provide accurate readings even under unbalanced phase loads and voltage fluctuations.

Import and export control of multiple MSLC-2 public utilities in the same network segment.

Woodward ToolKit ™ The software allows for flexible settings using the same basic menu tree and overview screen as the original MSLC, without the need for a handheld programmer. The graphical overview and trend analysis of generator and bus parameters make MSLC-2 debugging more convenient.

Toolkit can be accessed through one of the Ethernet ports or the RS-232 port.

Phase angle compensation can adjust the additional deviation correction of the transformer.


The system update function allows for system reconfiguration.

Supports up to 32 generators, 16 main circuit breakers, and/or contact circuit breakers.

Can be configured for main circuit breaker and contact circuit breaker applications.

Complex applications with up to 8 bus segments.

Automatic segment recognition.

Redundant Ethernet communication improves reliability.

The 'System Update' function allows for system reconfiguration.

Compatible with PLC and DCS through Modbus RTU or Modbus TCP.

Automated factory loading and unloading to achieve impact free load transfer with utilities.

Control the import and export levels of the entire factory relative to public utilities.

Overall factory power factor control.

Ethernet or RS-232 port, used to configure devices using Woodward ToolKit software.

Has UL/cUL and CE certification.

Technical specifications

Environmental condition

Storage environment temperature: -40 ° C to 85 ° C/-40 to 185 ° F.

Environmental humidity: 95%, non condensing.


Electrical parameters

Relay output: 120 Vac [1] rated value (V rated) 69/120 Vac; Maximum value (Vmax) 86/150 Vac; Rated phase to ground voltage of 150 Vac; Rated surge voltage (V surge) 2.5 kV. 480 Vac [4] Rated value (V rating) 277/480 Vac; Maximum value (Vmax) 346/600 Vac; Rated phase to ground voltage of 300 Vac; Rated surge voltage (V surge) 4.0 kV.

Analog input (non isolated): accuracy level 0.5.

Measurable AC windings: 3p-3w, 3p-4w, 3p-4w OD.

Setting range: 50 to 650000 Vac on the primary side.

Linear measurement range: 1.25 × V rated.

Measurement frequency: 50/60 Hz (40 to 85 Hz).

High impedance input; The resistance of each path: [1] 0.498 M Ω, [4] 2.0 M Ω.

Maximum power consumption per path:<0.15 W.

Rated value (I-rated): [1]../1A or [5]../5A.

Linear measurement range: I gen=3.0 × I rated; I main/ground=1.5 x I rated.

Setting range: 1 to 32000 A.

Load:<0.15 VA.

Rated short-time current (1 s): [1] 50 × I rated, [5] 10 × I rated.

Accuracy: Level 0.5.


Other

Setting range: 0.0 to 999999.9 MW/kvar.

Discrete input: electrical isolation; Input range 12/24 Vdc (8 to 40 Vdc); Input resistance of 20 kOhms.

Relay output: electrical isolation/no potential; Contact material AgCdO; Load (GP) 2.00 Aac@250  Vac、2.00  Adc@24  Vdc/0.36  Adc@125  Vdc/0.18  Adc@250  Vdc、1.00  Adc@24  Vdc/0.22  Adc@125  Vdc/0.10  Adc@250  Vdc。

Analog input (non isolated): can be freely scaled; Type 0 to 10 V/0 to 20 mA; Resolution 11 bits.

Shell: Powder coated aluminum for backplate installation.

Dimensions (width x height x depth): 250 x 227 x 84 mm (9.84 x 9.00 x 3.30 inches).

Connection: Screw/plug terminal 2.5 mm ².

Protection system: IP 20.

Weight: Approximately 1900 g (4.2 lbs).

Certification: Anti interference testing (CE) conducted in accordance with applicable EN guidelines; UL、CUL、GOST-R、CSA; Marine LR (type approval), ABS (type approval).

  • National Instruments cDAQ-9189 Chassis
  • National Instruments PXIe-8394 MXI Module
  • National Instruments PXIe-4112 Power Supply
  • National Instruments 778472-01 Module
  • National Instruments cFP-DO-401 Module
  • National Instruments PXIe-8379 Interface Card
  • National Instruments PXIe-7965R Module
  • National Instruments NI-9485 Relay Module
  • National Instruments 181045-01 Module
  • National Instruments TB-4302 Terminal Block
  • National Instruments PXI-2533 Matrix Switch Module
  • National Instruments PCI-6220 Analog Input Card
  • National Instruments PXI-2529 Matrix Switch Module
  • National Instruments 783732-01 Ordering Part Number
  • National Instruments PXI-6542 Digital Waveform Module
  • National Instruments PCI-1411 Image Acquisition Card
  • National Instruments PXI-6511 Industrial Digital I/O Module
  • National Instruments TPC-2012 Touch Panel Computer
  • National Instruments PXI-8101 Embedded Controller
  • National Instruments cRIO-9035 CompactRIO Controller
  • National Instruments PXIe-5114 Digitizer Card
  • National Instruments SCXI-1315 Block
  • National Instruments PXI-7842R Card
  • National Instruments PCI-6031E DAQ Device
  • National Instruments NI-9792 Gateway
  • National Instruments PXI-4132 SMU
  • National Instruments USB-5132 Digitizer
  • National Instruments NI 9244 Input Module
  • National Instruments SCXI-1163R Module
  • National Instruments PCI-6221 DAQ Device
  • National Instruments cFP-2120 Compact FieldPoint Controller
  • National Instruments cRIO-9073 CompactRIO Controller
  • National Instruments PCI-8516 CAN Interface Card
  • National Instruments PXIe-1073 5-Slot Chassis
  • National Instruments NI 9421 DSUB Digital Input Module
  • National Instruments PXI-4204 High Voltage Input Module
  • National Instruments PCI-6111 Multifunction DAQ Card
  • National Instruments cRIO-9035 CompactRIO Controller
  • National Instruments NI 9759 Powertrain Control Module
  • National Instruments 187254A-01 Ordering Part Number
  • National Instruments PXI-6624 Module
  • National Instruments cDAQ-9137 Chassis
  • National Instruments PXIe-8133 Controller
  • National Instruments 779139-01 Module
  • National Instruments FP-DI-301 Module
  • National Instruments 194021D-01L Module
  • National Instruments PXI-1000B Chassis
  • National Instruments PXIe-8510 Module
  • National Instruments PXI-6221 DAQ Card
  • National Instruments cDAQ-9188 Chassis
  • National Instruments PXI-5421 Arbitrary Waveform Generator
  • National Instruments cRIO-9023 CompactRIO Controller
  • National Instruments PCI-6221 Multifunction DAQ Card
  • National Instruments PXI-4065 Digital Multimeter Card
  • National Instruments NI 9477 Digital Output Module
  • National Instruments cDAQ-9185 TSN Ethernet Chassis
  • National Instruments NI 9147 4-Slot cRIO Chassis
  • National Instruments USB-6259 Mass Termination DAQ Device
  • National Instruments 184120F-01 Ordering Part Number
  • National Instruments PCI-4472B Sound and Vibration Module
  • National Instruments SCXI-1130 Switch
  • National Instruments VB-8012 VirtualBench
  • National Instruments PXI-7350 Controller
  • National Instruments eDAQ-9174 Chassis
  • National Instruments PXI-4461 DSA Module
  • National Instruments PCI-6280 DAQ Card
  • National Instruments PXI-6251 DAQ Card
  • National Instruments PXI-6653 Module
  • National Instruments PCI-6509 DIO Device
  • National Instruments NI 9751 Driver Module
  • National Instruments PXIe-6361 Multifunction I/O Module
  • National Instruments cRIO-9014 CompactRIO Controller
  • National Instruments PCI-7390 Motion Control Card
  • National Instruments PXI-8512 CAN Interface Module
  • National Instruments sbRIO-9636 Single-Board Controller
  • National Instruments IC-3120 Industrial Controller
  • National Instruments PCI-6220 M Series DAQ Card
  • National Instruments PXI-8176 Embedded Controller
  • National Instruments PXI-6132 S Series DAQ Module
  • National Instruments NI 9206 Analog Input Module
  • National Instruments PXI-2584 Switch Module
  • National Instruments 196541B-01L Module
  • National Instruments 778075-01 Module
  • National Instruments FP-RLY-420 Module
  • National Instruments USRP-2920 Radio
  • National Instruments PCIe-6351 DAQ Card
  • National Instruments cRIO-9040 Controller
  • National Instruments NI 9201 Input Module
  • National Instruments NI 9411 Input Module
  • National Instruments NI 9216 Input Module
  • National Instruments PCI-6221 DAQ Device
  • National Instruments PXI-4498 DSA Module
  • National Instruments PXI-6259 DAQ Card
  • National Instruments PXI-7354 Motion Controller
  • National Instruments FP-AI-110 Input Module
  • National Instruments 192172F-04L Module
  • National Instruments PXIe-8115 Controller
  • National Instruments 142931B-01L Module
  • National Instruments PXI-2503 Switch Module
  • National Instruments 776246-01 Module
  • National Instruments CFP-2110 Compact FieldPoint Controller
  • National Instruments 779429-01 Ordering Part Number
  • National Instruments NI-9149 8-Slot EtherCAT Chassis
  • National Instruments PXI-4110 Programmable DC Supply
  • National Instruments 192061-10 Ordering Part Number
  • National Instruments cDAQ-9181 Chassis Module Carrier
  • National Instruments NI 9437 Digital Input Module
  • National Instruments cFP-2020 Compact FieldPoint Controller
  • National Instruments PCI-6259 Multifunction DAQ Card
  • National Instruments FP-TC-120 Thermocouple Module
  • National Instruments NI-9174 CompactDAQ Chassis
  • National Instruments PXI-6030E DAQ Module
  • National Instruments PXIe-5160 Oscilloscope
  • National Instruments PXI-4462 DSA Module
  • National Instruments PXI-8109 Controller
  • National Instruments PXI-6259 DAQ Card
  • National Instruments PXI-6030E DAQ Card
  • National Instruments cRIO-9056 Controller
  • National Instruments PXIe-8370 MXI Kit
  • National Instruments USB-6212 DAQ Device
  • National Instruments RMX-4000 Electronic Load System
  • National Instruments 785040-01 Ordering Part Number
  • National Instruments cFP-AI-110 Analog Input Module
  • National Instruments cDAQ-9189 8-Slot Chassis
  • National Instruments PXIe-4139 Source Measure Unit
  • National Instruments PXI-5620 Digitizer Module
  • National Instruments PCIe-8371 MXI-Express Card
  • National Instruments 196762B-01L Ordering Part Number