Siemens medium voltage vacuum switch technology and components

F: | Au:FAN | DA:2025-11-24 | 993 Br: | 🔊 点击朗读正文 ❚❚ ▶ | Share:


Siemens medium voltage vacuum switch technology and components

Basic Information

Siemens medium voltage vacuum switch technology and components are mainly aimed at the medium voltage power system and industrial application fields, providing a comprehensive introduction to vacuum switch technology and related components. The document mentions that all Siemens related products have passed ISO 9001 (Quality Management), ISO 14001 (Environmental Management), OHSAS 18001 (Occupational Health and Safety) system certification, and comply with international standards such as IEC (International Electrotechnical Commission) and IEEE (Institute of Electrical and Electronics Engineers). Some products are compatible with Chinese GB/DL standards.



Medium Voltage Core Concepts and Application Scenarios

1. Definition of voltage level

Medium voltage: AC voltage ranging from 1kV to 52kV, mainly used for power distribution and industrial networks;

Low voltage: AC voltage ≤ 1kV or DC voltage ≤ 1.5kV;

High voltage: used for power transmission (specific scope not specified in the document, focus on medium voltage).

2. Typical application scenarios

Common voltage levels for specific scenarios in the field

Power system power station (generator circuit, ≤ 24kV), primary distribution station (high voltage to medium voltage), secondary distribution station (medium voltage to low voltage) 10kV-40kV (distribution network)

Industrial plants (powered by motors), mining, ships, 3kV-15kV (motor operating voltage)

Special fields (traction power supply) Germany/Austria/Switzerland (AC 15kV, 16.7Hz), other regions (AC 25kV, 50Hz), DC railways (≤ 3kV) AC 15kV/16.7Hz, AC 25kV/50Hz

3. Operating stress of medium voltage equipment

Medium voltage equipment needs to withstand various operating stresses, which is the core basis for selection and design:

Dielectric loss strength: able to withstand normal operating voltage (including fluctuations) and overvoltage (operation/lightning overvoltage);

Current carrying capacity: continuously carrying normal current, short-term carrying overcurrent, and instantaneous carrying short-circuit current;

Current on-off: on-off normal current, fault current, and special current (capacitive/inductive current, high-frequency transient current);

Isolation requirements: In the disconnected state, the safety isolation distance specified by the standard must be met for easy maintenance;

Operation frequency: It is necessary to adapt to multiple on-off operations in a short period of time (such as multi segment reclosing of the recloser).

image.png

Core technology: Vacuum arc extinguishing technology

Vacuum arc extinguishing technology is the core of Siemens medium voltage switchgear, which has the advantages of high reliability, long life, and low maintenance. The specific characteristics are as follows:

1. Arc extinguishing principle

When the contacts separate in the vacuum arc extinguishing chamber, a metal vapor arc is generated, and current flows through the metal vapor plasma; The arc automatically extinguishes when the current crosses zero, and the remaining metal vapor loses conductivity within a few microseconds. The insulation ability of the contact gap quickly recovers (with a recovery speed of 5kV/μ s), and can immediately withstand external voltage.

2. Key technological advantages

Low current cutoff: Using special contact materials, the cutoff current is only 2A-3A, avoiding excessive overvoltage when small currents are turned on and off;

Low arc voltage: The arc voltage is only 20V-200V, with low arc energy, minimal contact wear, and long equipment life;

Maintenance free: The vacuum environment is free of oxidation and impurities, and the arc extinguishing system does not require regular maintenance.

3. Contact type and applicable scenarios

Contact type, structural characteristics, current adaptability range, advantages, application product examples

Radial magnetic field contact cup-shaped/spiral structure, generating radial magnetic field ≤ 10kA (diffusion arc); >10kA (contraction arc, arc rotation) universal circuit breaker (3AH5) to avoid local overheating and uniform wear of contacts

Axial magnetic field contact disc-shaped structure, generating high axial magnetic field current (arc always spreads), uniform force on the contact surface, no local melting, high-capacity circuit breaker (3AH3)


Classification and Technical Parameters of Medium Voltage Equipment

Medium voltage equipment is divided into switch devices (for current switching) and non switch components (for protection, measurement, and auxiliary functions). The specific classification and key parameters are as follows:

1. Switchgear

(1) Vacuum circuit breaker

Vacuum circuit breakers can switch between normal and short-circuit currents, suitable for indoor and outdoor scenarios. The core models and parameters are as follows:

Type, Model, Series, Applicable Scenarios, Key Parameters (Maximum), Operating Mechanism

Indoor Circuit Breaker SION 3AE General Scenario (Industrial/Distribution) Rated Voltage 24kV, Rated Current 2000A, Short Circuit Breaking Current 40kA Spring Energy Storage Mechanism

3AH5 economical type, rated voltage for small capacity scenarios is 17.5kV, rated current is 2000A, short-circuit breaking current is 31.5kA, spring energy storage mechanism

3AH3 high-capacity scenario rated voltage 40.5kV, rated current 4000A, short-circuit breaking current 63kA, spring energy storage mechanism/magnetic operation mechanism

3AH36/37/38 generator circuit rated voltage 24kV, rated current 8000A, short-circuit breaking current 72kA, spring energy storage mechanism

3AH47 traction power supply (1/2 pole) compatible with 16.7Hz/25Hz/50Hz/60Hz, mechanical life of 60000 times, spring energy storage mechanism

Outdoor circuit breaker 3AF0 (tank type) for outdoor distribution, rated voltage for harsh environments of 40.5kV, rated current of 2500A, short-circuit breaking current of 31.5kA, spring energy storage mechanism, compliant with IEC 62271-100 S2 level

SDV (Dead Can) outdoor power distribution, including anti arc rated voltage of 38kV, rated current of 3000A, short-circuit breaking current of 40kA, spring energy storage mechanism/magnetic operation mechanism

(2) Recloser (3AD series)

Function: Integrated switch unit and controller, can automatically detect faults and complete multi segment coincidence, reducing power outage time caused by temporary faults;

Core parameters: rated voltage ≤ 38kV, rated current ≤ 800A, short-circuit breaking current ≤ 16kA, typical coincidence sequence O-0.2s-CO-2s-CO-2s-CO;

Controller: Provides 7SR224 (Reyrolle series) and 7SC80 (SIPROTEC series), supports communication protocols such as IEC 61850 and MODBUS, and is compatible with smart grids.

(3) Vacuum contactor (3TL series)

Function: High frequency switching (≤ 3 million mechanical lifetimes), suitable for loads such as motors, transformers, capacitors, etc;

Core model parameters:

Model Rated voltage Rated current Mechanical life Electrical life (rated current) Suitable load type

3TL81 7.2kV 400A 1 million times 250000 times motor (AC-3/AC-4), transformer

3TL61 7.2kV 450A 3 million times 1 million times motor (AC-3/AC-4), capacitor

3TL65 12kV 400A 1 million times 500000 times motor (AC-3/AC-4), reactor

3TL71 24kV 800A 1 million times 500000 times large capacity motor and transformer

Contactor fuse combination (3TL62/63/66): Integrated high-voltage HRC fuse, short-circuit breaking current ≤ 50kA, suitable for high current scenarios (such as 450A rated current).

(4) Switch - Isolation switch

Arc extinguishing principle: using hard gas to extinguish the arc. When the arc is generated, the insulating material releases gas to quickly extinguish the arc (the gas is non renewable and the number of operations is lower than that of vacuum equipment);

Function: It combines the functions of switching (on/off load current) and isolation (safe isolation distance), with high cost-effectiveness;

Application scenario: Industrial distribution and substation auxiliary circuits require the use of fuses to achieve short-circuit protection.

2. Non switch components

(1) Lightning arrester and voltage limiter

Function: Protect equipment from lightning overvoltage (external) and operation/grounding fault overvoltage (internal) damage;

Core model parameters:

Type, Model, Applicable Scenarios, Rated Voltage (Maximum), Nominal Discharge Current, Shell Material

Voltage limiter 3EF motor, dry-type transformer, frequency converter 12kV 1kA polyethylene

Lightning arrester 3EK4 distribution network, medium voltage switchgear 45kV 10kA (AC) silicone rubber

Line lightning arrester 3EK7 outdoor line protection 72.5kV 10kA silicone rubber

(2) High voltage fuse (3GD series)

Function: Short circuit protection, which melts when the current exceeds the threshold, cuts off the fault current, and protects equipment such as transformers, motors, capacitors, etc;

Classification:

Backup fuse: suitable for 7.2kV-36kV, rated current 6.3A-315A, short-circuit breaking current 40kA-63kA;

Motor protection fuse: suitable for 7.2kV-12kV, rated current 50A-315A, short-circuit breaking current 50kA;

Installation: Supports 1-phase/3-phase installation and can be combined with switchgear (such as switch fuse combination).

(3) Protection and measurement transformers

Current Transformer (CT):

Function: Convert high current proportionally to low current (for measurement/protection equipment use) to achieve electrical isolation;

Key requirements: Cannot operate in an open circuit (to avoid overvoltage), can have multiple secondary windings (measurement/protection separated);

Types: Indoor support type, indoor sleeve type, outdoor type.

Voltage Transformer (VT):

Function: Convert high voltage proportionally to low voltage (for measurement/protection equipment use);

Key requirements: Do not short-circuit operation (to avoid overheating), some windings with residual voltage (ground fault detection);

Type: Indoor, Outdoor.

(4) Auxiliary switch (3SV9 series)

Function: Auxiliary contacts for mechanical operation, used for electrical interlocking, auxiliary contactor/coil control, and motor operating mechanism drive;

Key parameters: rated voltage 230V AC/240V DC, rated thermal current 10A, mechanical life 100000 times, electrical life 30000 times;

Configuration flexibility: Switching levels 2-26, contacts can be customized as normally closed (NC), normally open (NO), or switch contacts, supporting different switching angles and overlapping contacts.


Selection guide and cooperation support

1. Selection criteria

Select the appropriate equipment based on the operating scenario (normal operation/fault operation) and load type (inductive/capacitive/resistive), and provide a detailed selection table in the document (example: inductive load selection under normal operation scenario):

Load type, current range, and equipment adaptation notes

No load transformer ≤ 0.03I, circuit breaker, contactor, switch isolator, recloser with neutral grounding transformer

When the motor is running and the circuit breaker and contactor are started, the current is ≤ 7Ir (cos π≤ 0.3)

Compensation reactor ≤ 2000A, transient recovery voltage rise rate of circuit breaker ≤ 6kV/μ s

2. Siemens cooperation and support

Collaboration Plan: Provide standardized testing systems (compliant with IEC 62271-200), design drawings, technical consulting, production training, and software tools (engineering design/document management) for switchgear manufacturers;

Supporting equipment:

SIMOPRIME: Medium voltage air insulated switchgear, compatible with SION 3AE circuit breakers, 7.2kV-24kV;

SIVACON S8: Low voltage distribution panel, rated current ≤ 7000A, in compliance with IEC 61439-2;

image.png

  • Bonfiglioli ACT 401-22A Frequency Inverter
  • Bonfiglioli ACU 401-29A Frequency Inverter
  • Bonfiglioli ACU401-19FA Frequency Inverter
  • Bonfiglioli ACU 201-07 FA Frequency Inverter
  • Bonfiglioli ACT401-33A Frequency Inverter 37kW
  • Bonfiglioli ACU 401-09 FA Inverter
  • Bonfiglioli RAN 8 S A 1 Gear Reducer
  • Bonfiglioli WR63U300P71B5B3KA Gearbox
  • Bonfiglioli 509 424 700 Inverter
  • Bonfiglioli AS 16/P P71 Gear Reducer
  • Bonfiglioli VF44F1P71B14 Gearbox
  • Bonfiglioli AGL402-13 1 FA Inverter
  • Bonfiglioli ACT 401-45A Main Board
  • Bonfiglioli W 110U 100 Gearbox
  • Bonfiglioli VF 49/F Gearbox
  • Bonfiglioli AGL402-09 1FA Inverter
  • Bonfiglioli ANG 410-19 3 FA Inverter
  • Bonfiglioli ANG 410-33 6A Inverter
  • Bonfiglioli W86UN56C Gearbox
  • Bonfiglioli 2KB2 060-0405 Motor
  • Bonfiglioli VF49P P71B14B3 Gearbox
  • Bonfiglioli SA 400-150 Inverter
  • Bonfiglioli TQF 070 Planetary Gearbox
  • Bonfiglioli ACT 401-19 A Inverter
  • Bonfiglioli ACT 401-13FA Inverter
  • Bonfiglioli W 63 U 24 Gearbox
  • Bonfiglioli BN 80 B4 Electric Motor
  • Bonfiglioli A 30 2 UH35 Gearbox
  • Bonfiglioli ACT 401-09 FA Inverter
  • Bonfiglioli EM-SYS DS179675010 Communication Module
  • Bonfiglioli AGL402-15 2 FA Inverter
  • Bonfiglioli W63UF115P90B5B3 Gear Reducer
  • Bonfiglioli 2KB2 060-0405-A00003 Bearing
  • Bonfiglioli VF 44 A 10 P63 B5 B3 Gearbox
  • Bonfiglioli ACU401-13FA Frequency Inverter
  • Bonfiglioli ACT 201-11FA Inverter
  • Bonfiglioli AGL402-15 2 FA Inverter
  • Bonfiglioli AGL402-07 1 FA Inverter
  • Bonfiglioli ACU 410-19 3 A Inverter
  • Bonfiglioli A 10 2 UH25 P71 Gearmotor
  • Bonfiglioli ACT 401-13 FA Inverter
  • Bonfiglioli ACU 410-15 2 FA Inverter
  • Bonfiglioli ACU 410-27 5 A Inverter
  • Bonfiglioli BN 63B 4 B5 Motor
  • Bonfiglioli AGL402-18 2 FA Frequency Inverter
  • Bonfiglioli W86-UF1-P90B5 Worm Gear Reducer
  • Bonfiglioli MP 080 80 STD 80A1 Planetary Gearbox
  • Bonfiglioli BN90S4 Motor
  • Bonfiglioli A413 UH40 Gear Motor
  • Bonfiglioli VF 63 Gear Reducer
  • Bonfiglioli ACU 201-05 FA Inverter
  • Bonfiglioli ACT 401-13FA Inverter
  • Bonfiglioli LC 120 1 10 STD 110A1 CD 24 KE Gear Unit
  • Bonfiglioli Fuji GVX2000-11-TSL2 Inverter
  • Bonfiglioli ACU 401-05 FA Inverter
  • Bonfiglioli W86UP100B5 Gearbox
  • Bonfiglioli MP 130.1.5.10 Gear Unit
  • Bonfiglioli ACT W401-29C Vector Inverter
  • Bonfiglioli BE 71A 4 Gearmotor
  • Bonfiglioli BN 71B 4 Asynchronous Motor
  • Bonfiglioli W110U100P90B5B3 Gear Reducer
  • Bonfiglioli VF 49 F1 7 P71 B5 B3 Gearbox
  • Bonfiglioli MP 080 2 16 STD 50D Gear Unit
  • Bonfiglioli VF 44 A 10 P63 B5 B3 Worm Gearbox
  • Bonfiglioli ACU401-13FA Frequency Inverter
  • Bonfiglioli CM-EtherCAT DS179675207 Module
  • Bonfiglioli 8AF2400CK BX 90 L A 4 Motor
  • Bonfiglioli BRA 400-045 BF2 Inverter
  • Bonfiglioli TQF 070 Planetary Servo Gearbox
  • Bonfiglioli B-SYN-04-0780 Servomotor
  • Bonfiglioli TA45.50-25.0-D-0S Shaft Gearbox
  • Bonfiglioli AS 20 F 21.19 071 B5 Helical Gearbox
  • Bonfiglioli 07/63 EE B5 Gear Unit
  • Bonfiglioli EVO200280738 Drive Assembly
  • Bonfiglioli ACT 401-29A Frequency Converter
  • Bonfiglioli ACT 401-22A Frequency Inverter
  • Bonfiglioli Siemens 1LA70964AA91-Z VF72 Motor
  • Bonfiglioli BN 100 LA 4 Electric Motor
  • Bonfiglioli BN 63B 4 8D1002058S Electric Motor
  • Bonfiglioli HPC-Module 150303003 Inverter Module
  • Bonfiglioli Vectron ACU 210-07 1 FA Drive Unit
  • Bonfiglioli ACT 401-18FA Frequency Inverter
  • Bonfiglioli VCB 400-060 400031060 Brake Chopper
  • Bonfiglioli W86UP90B5 2G28010656 Gearbox Reducer
  • Bonfiglioli EM-ENC-05 DS179675024 Encoder Module
  • Bonfiglioli ACT 401-25A Frequency Inverter
  • Bonfiglioli PMT400-034 BF1 Inverter
  • Bonfiglioli CM-485 T Communication Module
  • Bonfiglioli AS 20 F 21.19 071 B5 Gearbox
  • Bonfiglioli W86UFC146P90B5B3 Gear Reducer
  • Bonfiglioli ACT201-05FA Frequency Inverter
  • Bonfiglioli VF 44 P P63 B14 Gear Reducer Motor
  • Bonfiglioli ZFA 400-014 D Frequency Inverter
  • Bonfiglioli Engineering 2B HMI Touch Panel
  • Bonfiglioli ACT 401-26A Inverter Driver
  • Bonfiglioli SPL400 13F Inverter
  • Bonfiglioli ZFA 400-040 D Frequency Inverter
  • Bonfiglioli ACT 401-23A Frequency Inverter
  • Bonfiglioli BTD5-2730-30-400-FD24 Servo Motor
  • Bonfiglioli ACT401-11FA Frequency Inverter
  • Bonfiglioli EM-ENC 03 179-675 022 Encoder Module
  • Bonfiglioli EM-I/O 03 179-675 043 I/O Module
  • Bonfiglioli DS179675597 Meter Module
  • Bonfiglioli ZFA 400-010 D2 Frequency Inverter
  • Bonfiglioli Vectron ZBA400-018D Frequency Inverter
  • Bonfiglioli Vectron ACT 401-26A Inverter
  • Bonfiglioli ACT ZR 401-18D Frequency Inverter
  • Bonfiglioli Vectron ZFB 400-018 Frequency Inverter
  • Bonfiglioli ACT W 401-29 C Frequency Inverter
  • Bonfiglioli Vectron BRA 400-045 BF2 Inverter
  • Bonfiglioli ACT 400-034A Frequency Inverter
  • Bonfiglioli RAN 15 D A 1 HS B3 Gear Unit
  • Bonfiglioli ZFB 400-060 Frequency Inverter
  • Milton Industries LT1240 LTI Tool Lugnut Remover
  • LTi Drives SO84.200.P030.0000.0-W Servo Spindle 100kW
  • Milton LTI LT1600P Torx Stick
  • LTI Lust VF1424L Variable Frequency Drive
  • LTI SO84.045.0002.0001.2-W Servo Drive
  • LTI Lust VF1404M Frequency Inverter
  • LTI SA54.0550.0033.0000.0 Servo Drive
  • LTI Tools LT-1400C Wheel Torque Extension
  • LTI SO84.143.0020.0101.2-W Servo Drive
  • LTI MOTION SC34.0200.0011.0000.0 Servo Drive
  • LTI DRIVES MS100 0927.0017 Assembly Set
  • LTI MOTION SO84.032.0003.0101.2 Servo Drive
  • LTI DRIVES SE84.200.SC00.0001.0-W 110kW Drive
  • Lust CDE34.005.W2.2 Lti Drives Servo Drive
  • LTi SO84.012.0030.0011.2 ServoOne Servo Drive