Siemens medium voltage vacuum switch technology and components

来源: | 作者:FAN | 发布时间 :2025-11-24 | 460 次浏览: | 🔊 Click to read aloud ❚❚ | Share:


Siemens medium voltage vacuum switch technology and components

Basic Information

Siemens medium voltage vacuum switch technology and components are mainly aimed at the medium voltage power system and industrial application fields, providing a comprehensive introduction to vacuum switch technology and related components. The document mentions that all Siemens related products have passed ISO 9001 (Quality Management), ISO 14001 (Environmental Management), OHSAS 18001 (Occupational Health and Safety) system certification, and comply with international standards such as IEC (International Electrotechnical Commission) and IEEE (Institute of Electrical and Electronics Engineers). Some products are compatible with Chinese GB/DL standards.



Medium Voltage Core Concepts and Application Scenarios

1. Definition of voltage level

Medium voltage: AC voltage ranging from 1kV to 52kV, mainly used for power distribution and industrial networks;

Low voltage: AC voltage ≤ 1kV or DC voltage ≤ 1.5kV;

High voltage: used for power transmission (specific scope not specified in the document, focus on medium voltage).

2. Typical application scenarios

Common voltage levels for specific scenarios in the field

Power system power station (generator circuit, ≤ 24kV), primary distribution station (high voltage to medium voltage), secondary distribution station (medium voltage to low voltage) 10kV-40kV (distribution network)

Industrial plants (powered by motors), mining, ships, 3kV-15kV (motor operating voltage)

Special fields (traction power supply) Germany/Austria/Switzerland (AC 15kV, 16.7Hz), other regions (AC 25kV, 50Hz), DC railways (≤ 3kV) AC 15kV/16.7Hz, AC 25kV/50Hz

3. Operating stress of medium voltage equipment

Medium voltage equipment needs to withstand various operating stresses, which is the core basis for selection and design:

Dielectric loss strength: able to withstand normal operating voltage (including fluctuations) and overvoltage (operation/lightning overvoltage);

Current carrying capacity: continuously carrying normal current, short-term carrying overcurrent, and instantaneous carrying short-circuit current;

Current on-off: on-off normal current, fault current, and special current (capacitive/inductive current, high-frequency transient current);

Isolation requirements: In the disconnected state, the safety isolation distance specified by the standard must be met for easy maintenance;

Operation frequency: It is necessary to adapt to multiple on-off operations in a short period of time (such as multi segment reclosing of the recloser).

image.png

Core technology: Vacuum arc extinguishing technology

Vacuum arc extinguishing technology is the core of Siemens medium voltage switchgear, which has the advantages of high reliability, long life, and low maintenance. The specific characteristics are as follows:

1. Arc extinguishing principle

When the contacts separate in the vacuum arc extinguishing chamber, a metal vapor arc is generated, and current flows through the metal vapor plasma; The arc automatically extinguishes when the current crosses zero, and the remaining metal vapor loses conductivity within a few microseconds. The insulation ability of the contact gap quickly recovers (with a recovery speed of 5kV/μ s), and can immediately withstand external voltage.

2. Key technological advantages

Low current cutoff: Using special contact materials, the cutoff current is only 2A-3A, avoiding excessive overvoltage when small currents are turned on and off;

Low arc voltage: The arc voltage is only 20V-200V, with low arc energy, minimal contact wear, and long equipment life;

Maintenance free: The vacuum environment is free of oxidation and impurities, and the arc extinguishing system does not require regular maintenance.

3. Contact type and applicable scenarios

Contact type, structural characteristics, current adaptability range, advantages, application product examples

Radial magnetic field contact cup-shaped/spiral structure, generating radial magnetic field ≤ 10kA (diffusion arc); >10kA (contraction arc, arc rotation) universal circuit breaker (3AH5) to avoid local overheating and uniform wear of contacts

Axial magnetic field contact disc-shaped structure, generating high axial magnetic field current (arc always spreads), uniform force on the contact surface, no local melting, high-capacity circuit breaker (3AH3)


Classification and Technical Parameters of Medium Voltage Equipment

Medium voltage equipment is divided into switch devices (for current switching) and non switch components (for protection, measurement, and auxiliary functions). The specific classification and key parameters are as follows:

1. Switchgear

(1) Vacuum circuit breaker

Vacuum circuit breakers can switch between normal and short-circuit currents, suitable for indoor and outdoor scenarios. The core models and parameters are as follows:

Type, Model, Series, Applicable Scenarios, Key Parameters (Maximum), Operating Mechanism

Indoor Circuit Breaker SION 3AE General Scenario (Industrial/Distribution) Rated Voltage 24kV, Rated Current 2000A, Short Circuit Breaking Current 40kA Spring Energy Storage Mechanism

3AH5 economical type, rated voltage for small capacity scenarios is 17.5kV, rated current is 2000A, short-circuit breaking current is 31.5kA, spring energy storage mechanism

3AH3 high-capacity scenario rated voltage 40.5kV, rated current 4000A, short-circuit breaking current 63kA, spring energy storage mechanism/magnetic operation mechanism

3AH36/37/38 generator circuit rated voltage 24kV, rated current 8000A, short-circuit breaking current 72kA, spring energy storage mechanism

3AH47 traction power supply (1/2 pole) compatible with 16.7Hz/25Hz/50Hz/60Hz, mechanical life of 60000 times, spring energy storage mechanism

Outdoor circuit breaker 3AF0 (tank type) for outdoor distribution, rated voltage for harsh environments of 40.5kV, rated current of 2500A, short-circuit breaking current of 31.5kA, spring energy storage mechanism, compliant with IEC 62271-100 S2 level

SDV (Dead Can) outdoor power distribution, including anti arc rated voltage of 38kV, rated current of 3000A, short-circuit breaking current of 40kA, spring energy storage mechanism/magnetic operation mechanism

(2) Recloser (3AD series)

Function: Integrated switch unit and controller, can automatically detect faults and complete multi segment coincidence, reducing power outage time caused by temporary faults;

Core parameters: rated voltage ≤ 38kV, rated current ≤ 800A, short-circuit breaking current ≤ 16kA, typical coincidence sequence O-0.2s-CO-2s-CO-2s-CO;

Controller: Provides 7SR224 (Reyrolle series) and 7SC80 (SIPROTEC series), supports communication protocols such as IEC 61850 and MODBUS, and is compatible with smart grids.

(3) Vacuum contactor (3TL series)

Function: High frequency switching (≤ 3 million mechanical lifetimes), suitable for loads such as motors, transformers, capacitors, etc;

Core model parameters:

Model Rated voltage Rated current Mechanical life Electrical life (rated current) Suitable load type

3TL81 7.2kV 400A 1 million times 250000 times motor (AC-3/AC-4), transformer

3TL61 7.2kV 450A 3 million times 1 million times motor (AC-3/AC-4), capacitor

3TL65 12kV 400A 1 million times 500000 times motor (AC-3/AC-4), reactor

3TL71 24kV 800A 1 million times 500000 times large capacity motor and transformer

Contactor fuse combination (3TL62/63/66): Integrated high-voltage HRC fuse, short-circuit breaking current ≤ 50kA, suitable for high current scenarios (such as 450A rated current).

(4) Switch - Isolation switch

Arc extinguishing principle: using hard gas to extinguish the arc. When the arc is generated, the insulating material releases gas to quickly extinguish the arc (the gas is non renewable and the number of operations is lower than that of vacuum equipment);

Function: It combines the functions of switching (on/off load current) and isolation (safe isolation distance), with high cost-effectiveness;

Application scenario: Industrial distribution and substation auxiliary circuits require the use of fuses to achieve short-circuit protection.

2. Non switch components

(1) Lightning arrester and voltage limiter

Function: Protect equipment from lightning overvoltage (external) and operation/grounding fault overvoltage (internal) damage;

Core model parameters:

Type, Model, Applicable Scenarios, Rated Voltage (Maximum), Nominal Discharge Current, Shell Material

Voltage limiter 3EF motor, dry-type transformer, frequency converter 12kV 1kA polyethylene

Lightning arrester 3EK4 distribution network, medium voltage switchgear 45kV 10kA (AC) silicone rubber

Line lightning arrester 3EK7 outdoor line protection 72.5kV 10kA silicone rubber

(2) High voltage fuse (3GD series)

Function: Short circuit protection, which melts when the current exceeds the threshold, cuts off the fault current, and protects equipment such as transformers, motors, capacitors, etc;

Classification:

Backup fuse: suitable for 7.2kV-36kV, rated current 6.3A-315A, short-circuit breaking current 40kA-63kA;

Motor protection fuse: suitable for 7.2kV-12kV, rated current 50A-315A, short-circuit breaking current 50kA;

Installation: Supports 1-phase/3-phase installation and can be combined with switchgear (such as switch fuse combination).

(3) Protection and measurement transformers

Current Transformer (CT):

Function: Convert high current proportionally to low current (for measurement/protection equipment use) to achieve electrical isolation;

Key requirements: Cannot operate in an open circuit (to avoid overvoltage), can have multiple secondary windings (measurement/protection separated);

Types: Indoor support type, indoor sleeve type, outdoor type.

Voltage Transformer (VT):

Function: Convert high voltage proportionally to low voltage (for measurement/protection equipment use);

Key requirements: Do not short-circuit operation (to avoid overheating), some windings with residual voltage (ground fault detection);

Type: Indoor, Outdoor.

(4) Auxiliary switch (3SV9 series)

Function: Auxiliary contacts for mechanical operation, used for electrical interlocking, auxiliary contactor/coil control, and motor operating mechanism drive;

Key parameters: rated voltage 230V AC/240V DC, rated thermal current 10A, mechanical life 100000 times, electrical life 30000 times;

Configuration flexibility: Switching levels 2-26, contacts can be customized as normally closed (NC), normally open (NO), or switch contacts, supporting different switching angles and overlapping contacts.


Selection guide and cooperation support

1. Selection criteria

Select the appropriate equipment based on the operating scenario (normal operation/fault operation) and load type (inductive/capacitive/resistive), and provide a detailed selection table in the document (example: inductive load selection under normal operation scenario):

Load type, current range, and equipment adaptation notes

No load transformer ≤ 0.03I, circuit breaker, contactor, switch isolator, recloser with neutral grounding transformer

When the motor is running and the circuit breaker and contactor are started, the current is ≤ 7Ir (cos π≤ 0.3)

Compensation reactor ≤ 2000A, transient recovery voltage rise rate of circuit breaker ≤ 6kV/μ s

2. Siemens cooperation and support

Collaboration Plan: Provide standardized testing systems (compliant with IEC 62271-200), design drawings, technical consulting, production training, and software tools (engineering design/document management) for switchgear manufacturers;

Supporting equipment:

SIMOPRIME: Medium voltage air insulated switchgear, compatible with SION 3AE circuit breakers, 7.2kV-24kV;

SIVACON S8: Low voltage distribution panel, rated current ≤ 7000A, in compliance with IEC 61439-2;

image.png

  • YASKAWA SGMPH-04AAA61D-OY 200V 400W Servo Motor
  • YASKAWA SGMPH-08A1A41 750W Servo Motor with Gearbox
  • OMRON C60K-CDR-D K-Type CPU PLC
  • OMRON CS1W-AD081-V1 Analog Input Module
  • OMRON CP1H-X40DT-D Compact PLC
  • OMRON 3G3SV-BB007-E 0.75kW Inverter
  • YASKAWA SGDH-10DE-OY 1kW Servo Pack
  • OMRON C60H-C5DR-DE-V1 SYSMAC CPU PLC
  • OMRON C60H-C5DR-DE-V1 SYSMAC CPU PLC
  • OMRON 3G3MV-P10CDT3-E RS422/485 Inverter PLC Board
  • OMRON C200PC-ISA02-DRM-E SYSMAC Board PLC with Floppy & Operator Panel
  • OMRON 3G3SV-BB007-E 0.75kW Inverter
  • OMRON CP1H-X40DT-D Compact PLC
  • OMRON CS1W-AD081-V1 Analog Input Module
  • OMRON C60K-CDR-C K-Type CPU PLC
  • YASKAWA SGMPH-08A1A41 750W Servo Motor with Gearbox
  • YASKAWA SGMPH-04AAA61D-OY 200V 400W Servo Motor
  • OMRON CJ1W-DA041 Analog Output Module
  • OMRON C60H-C5DR-DE-V1 SYSMAC CPU PLC
  • OMRON 3G3MV-P10CDT3-E RS422/485 Inverter PLC Board
  • OMRON C200PC-ISA02-DRM-E SYSMAC Board PLC
  • Omron CQM1H-MAB42 Analog I/O Board
  • Omron C200PC-ISA02-DRM-E SYSMAC Board
  • Oriental Motor ARD-C CM10-1 Stepping Driver
  • EVA 915.85.003 Embedded CPU Module
  • Omron C60H-C1DR-DE-V1 PLC CPU
  • TE.CO TFX 4G10 Industrial Power Cable
  • Siemens 6SL3120-2TE15-0AA4 Motor Module
  • Emerson SolaHD SDN10-24-100P Power Supply
  • PARKER HPD2S5N/K005 Servo Drive
  • Danfoss VLT 3008 Variable Speed Drive
  • Saia Burgess Controls PCD4.H31 PLC CPU
  • OMRON C200HW-PRT21 Profibus DP Slave Unit
  • OMRON TJ1-ML04 Trajexia Motion Controller
  • Schneider Electric Pre-Wired PLC Control Box
  • Allen Bradley 1336-L8E AC Drive
  • Siemens 6ES7123-1GB60-0AB0 PLC Module
  • Automation Direct D3-08B-1 PLC Chassis 8 Slot
  • OMRON 3G3XV-A2007 VFD 0.75kW 220V
  • STOBER F102SG0230MO20 Gear Drive Technology
  • Saia PCD4.H32 PCD4 Series PLC
  • Omron NSJ12-TS01B-G5D NSJ Terminal
  • Biticino MA250 T7314A Megatiker Circuit Breaker
  • Omron ZX-LDA41 ZX-LD300L Laser Sensor
  • Siemens 6ES7511-1AK02-0AB0 CPU 1511-1 PN
  • Saia Burgess Controls SBC PCD PLC Module
  • Siemens 6ES5 244-3AA21 S5 Temperature Module
  • Omron NSJ5-SQ01-DRM NSJ Controller
  • Omron NT15S-SF121B-E Programmable Terminal
  • Yaskawa CIMR-F7Z4045 45kW VFD AC Drive
  • AB 1494U-D100 Smart Motor Controller
  • Omron NA5-7W001B-V1 Touch Screen HMI
  • Fanuc A16B-1000-0400/01A CNC Control Board
  • Omron CV2000-CPU01-EV1 PLC CPU Unit
  • Eaton XV-102-B4-35TQRF-10-PLC Touch Panel
  • Siemens 6FX1121-3BB01 SINUMERIK Board
  • SCE M68-2000 2 Axis CNC Servo Controller
  • Omron R88M-K20030T-BS2 AC Servo Motor
  • Omron G3NH-4150B Solid State Relay
  • BITICINO MA250 T7313A Megatiker PLC Disconnector
  • IFM 2MSTR AS-i PROFIBUS DP Gateway
  • Danfoss VLT 3022 175H1238 Variable Speed Drive
  • PASABAN MTC-3052 FAST I/O Module
  • Allen Bradley 1746-A7 SLC 500 Chassis
  • Mitsubishi NF1600-SEW MCCB
  • Schneider LTMR100EBD Motor Management Controller
  • Yokogawa AIP121-S3 Analog Input Module
  • Siemens 6ES7135-4LB02-0AB0 ET200S AO Module
  • Motor Power SKA DDR 148-240 Torque Motor
  • OMRON CS1H-CPU63-EV1 PLC CPU Unit
  • ABB UFC921A101 Main Control Board
  • ABB UFC921A Main Control Unit
  • ABB UFC911B108 Drive Main Control Unit
  • ABB UFC911B106 Drive Main Control Unit
  • ABB UFC911B101 Drive Main Control Unit
  • ABB UFC765AE102 Drive Control Interface Board
  • ABB UFC762AE101 I/O and Communication Extension Board
  • ABB UFC760BE41 I/O and Communication Extension Board
  • ABB UFC760BE145 I/O and Communication Extension Module
  • ABB UFC721BE101 Fieldbus Communication Adapter Module
  • ABB UFC721AE101 3BHB002916R0101 Network Interface
  • ABB UFC718AE101 HIEE300936R0101 Communication Module
  • ABB UDC920BE01 3BHE034863R0001 Communication Module
  • GE IS420UCSCH1A-F-VO.1-A Controller Module
  • GE UCSC H1 IS420UCSCH1A Controller Station Card
  • ABB UCD240A101 3BHE022287R0101 Process Controller
  • ABB UCD224A103 Process I/O Module
  • ABB UCD224A102 Analog Input Module
  • WOODWARD 9907-838 Load Sharing Module
  • B&R X20CP1485-1 Industrial PC CPU Module
  • ELAU MC-4/11/22/400 4-Axis Servo Drive
  • ELAU C600/10/1/1/1/00 Configurable Safety Relay
  • BENTLY 60R/SIM01 Proximitor Power Supply
  • BENTLY 60R/PPM01 Protection Processing Module
  • BENTLY 60R/PNL01 Operator Control Panel
  • BENTLY 60R/PIM01 Panel Interface Module
  • BENTLY 60R/INP07 Isolated DC Input Module
  • BENTLY 60R/INP01 4-Channel Analog Input Module
  • BENTLY 60R/CMM01 Communication Multiplexer Module
  • BENTLY 60R/CHA02 System Chassis Rack Enclosure
  • BENTLY 60R/CGW01 Condition Monitoring Gateway
  • Pacific Scientific P70360-SDN Servo Motor
  • HONEYWELL 05701-A-0284 Signal Conditioner
  • YOKOGAWA NFCP501-W05 Pressure Transmitter
  • ABB CI541V1 3BSE0146666R1 Control Interface
  • ABB DSTC176 57310001-KT Terminal Base Unit
  • ABB DSDP170K02 3BSE019925R1 Analog Input Module
  • ABB DSBC173 57310001-KH Terminal Base Unit
  • ABB DSAI130K01 5730-030-UC Thermocouple Input
  • ABB DSRF182 57310255-AL Relay Output Module
  • ABB SC520 3BSE003816R1 Compact PLC
  • ABB DSDP140A 57160001-ACT Analog Input Module
  • ABB DSAI130 57120001-P Analog Input Module
  • ABB SCYC55830 3AFE58063282 MCCB
  • Fireye 95DSS3-1CEX UV Flame Scanner
  • ABB DSDP170 57160001-ADF Analog Input Module
  • ABB CI532 3BSC140120R1 Communication Interface
  • ABB DSAO120A 3BSE018293R1 Analog Output Module
  • ABB CI869K01 3BSE049110R1 Ethernet Interface
  • ABB CI522A 3BSE018460R1 PROFIBUS DP Master
  • GUTOR OP6257 Rectifier Control Unit
  • Meggitt C327845-11 Gas Shutoff Valve
  • ABB SACO64D4 4-Pole Digital Annunciator Unit
  • ABB CI522AK04 3BSE018451R1 PROFIBUS DP Module
  • ABB DSAI130DK01 3BSE020828R1 Temperature Input Module
  • ABB CI546 3BSE012610R1 PROFIBUS DP Master Module
  • ABB SC510 3BSE003832R1 Compact PLC Controller
  • ABB CI540 3BSE001077R1 PROFIBUS DP Slave Module