ABB PML630 Load Shedding Controller

来源: | 作者:FAN | 发布时间 :2025-05-12 | 616 次浏览: | 🔊 Click to read aloud ❚❚ | Share:

ABB PML630 Load Shedding Controller

Overview
PML630 is a power management IED that provides comprehensive load shedding solution for the power network in an industrial plant. It protects the plant against blackouts and power source outages due to system disturbances.
This IED is a member of ABB’s Relion® product family and a part of its 630 product series characterized by functional scalability and flexible configurability.
PML630 is identical to the Relion 630 series IEDs and does not have any specific hardware modules. It is only the application functions pre-loaded in the IED that differentiate it from the other 630 series IEDs.


The IED supports various modes of load shedding.

• Fast load shedding based on network contingencies
• Slow load shedding based on transformer overloading or the maximum demand violation of the grid tie feeder
• Manual load shedding based on operator defined priorities
The supported communication protocols including the IEC 61850 offer seamless connectivity with other Relion series IEDs and COM600 Station Automation device to realise the load shedding functionality.
The IED uses GOOSE and MMS communication profiles for I/O data transfer with other Relion series IEDs and COM600 Station Automation device.

Core functions

Ensuring power supply for critical loads: In the event of network interference, PML630 can quickly, accurately, and selectively cut off non critical loads to ensure continuous power supply for critical process loads. This function greatly reduces the duration and frequency of industrial production interruptions in the distribution network, while avoiding damage to electrical and process equipment due to power outages.

Based on comprehensive power and low-frequency load shedding: This controller integrates comprehensive power and low-frequency load shedding mechanisms. In the face of emergency situations such as loss of single or multiple power sources, grid disintegration, network or process conditions (such as frequency change rate, etc.), the ability to quickly respond to load shedding ensures the stability of the power system.


Working mode

Fast load shedding: When a serious imbalance in the power system is detected due to network emergencies (such as short circuit faults, line trips, etc.), PML630 can perform a fast load shedding operation in a very short period of time (from interference detection to unloading command generation time guaranteed within 20 milliseconds), quickly cutting off some less important loads, preventing a significant decrease in system frequency and voltage, and maintaining stable system operation.

Slow load shedding: PML630 will activate the slow load shedding mode based on situations such as transformer overload or violations of the maximum demand of power grid interconnection lines and generators. By gradually cutting off the load, the power system can be restored to a safe operating state, avoiding damage to equipment caused by long-term overload.

Manual load shedding: Operators can manually initiate unloading operations based on power definitions or load feeder priorities. This flexible control method allows for human intervention in power distribution in specific situations, such as planned maintenance, system debugging, etc., to ensure that system operation meets actual needs.

Low frequency load shedding (backup): As a backup mechanism for fast and slow load shedding, low frequency load shedding plays a role when the system frequency continues to decrease and other load shedding measures fail to effectively prevent it. When the system frequency is below the preset threshold, PML630 will cut off some loads in the predetermined order and magnitude to prevent system frequency collapse.


Safety information Dangerous voltages can occur on the connectors, even though the auxiliary voltage has been disconnected. Non-observance can result in death, personal injury or substantial property damage. 

Only a competent electrician is allowed to carry out the electrical installation. National and local electrical safety regulations must always be followed. 

The frame of the IED has to be carefully earthed. Whenever changes are made in the IED, measures should be taken to avoid inadvertent tripping. 

The IED contains components which are sensitive to electrostatic discharge. Unnecessary touching of electronic components must therefore be avoided.


Manual conventions
Conventions used in IED manuals. A particular convention may not be used in this manual.
Abbreviations and acronyms in this manual are spelled out in the glossary.
The glossary also contains definitions of important terms.
Push button navigation in the LHMI menu structure is presented by using the push button icons, for example:
To navigate between the options, use  and .HMI menu paths are presented in bold, for example:
Select Main menu/Settings.


LHMI messages are shown in Courier font, for example:

To save the changes in non-volatile memory, select Yes and press .
Parameter names are shown in italics, for example:
The function can be enabled and disabled with the Operation setting.
The ^ character in front of an input or output signal name in the function block symbol given for a function, indicates that the user can set an own signal name in PCM600.
  • ABB UFC921A101 Main Control Board
  • ABB UFC921A Main Control Unit
  • ABB UFC911B108 Drive Main Control Unit
  • ABB UFC911B106 Drive Main Control Unit
  • ABB UFC911B101 Drive Main Control Unit
  • ABB UFC765AE102 Drive Control Interface Board
  • ABB UFC762AE101 I/O and Communication Extension Board
  • ABB UFC760BE41 I/O and Communication Extension Board
  • ABB UFC760BE145 I/O and Communication Extension Module
  • ABB UFC721BE101 Fieldbus Communication Adapter Module
  • ABB UFC721AE101 3BHB002916R0101 Network Interface
  • ABB UFC718AE101 HIEE300936R0101 Communication Module
  • ABB UDC920BE01 3BHE034863R0001 Communication Module
  • GE IS420UCSCH1A-F-VO.1-A Controller Module
  • GE UCSC H1 IS420UCSCH1A Controller Station Card
  • ABB UCD240A101 3BHE022287R0101 Process Controller
  • ABB UCD224A103 Process I/O Module
  • ABB UCD224A102 Analog Input Module
  • WOODWARD 9907-838 Load Sharing Module
  • B&R X20CP1485-1 Industrial PC CPU Module
  • ELAU MC-4/11/22/400 4-Axis Servo Drive
  • ELAU C600/10/1/1/1/00 Configurable Safety Relay
  • BENTLY 60R/SIM01 Proximitor Power Supply
  • BENTLY 60R/PPM01 Protection Processing Module
  • BENTLY 60R/PNL01 Operator Control Panel
  • BENTLY 60R/PIM01 Panel Interface Module
  • BENTLY 60R/INP07 Isolated DC Input Module
  • BENTLY 60R/INP01 4-Channel Analog Input Module
  • BENTLY 60R/CMM01 Communication Multiplexer Module
  • BENTLY 60R/CHA02 System Chassis Rack Enclosure
  • BENTLY 60R/CGW01 Condition Monitoring Gateway
  • Pacific Scientific P70360-SDN Servo Motor
  • HONEYWELL 05701-A-0284 Signal Conditioner
  • YOKOGAWA NFCP501-W05 Pressure Transmitter
  • ABB CI541V1 3BSE0146666R1 Control Interface
  • ABB DSTC176 57310001-KT Terminal Base Unit
  • ABB DSDP170K02 3BSE019925R1 Analog Input Module
  • ABB DSBC173 57310001-KH Terminal Base Unit
  • ABB DSAI130K01 5730-030-UC Thermocouple Input
  • ABB DSRF182 57310255-AL Relay Output Module
  • ABB SC520 3BSE003816R1 Compact PLC
  • ABB DSDP140A 57160001-ACT Analog Input Module
  • ABB DSAI130 57120001-P Analog Input Module
  • ABB SCYC55830 3AFE58063282 MCCB
  • Fireye 95DSS3-1CEX UV Flame Scanner
  • ABB DSDP170 57160001-ADF Analog Input Module
  • ABB CI532 3BSC140120R1 Communication Interface
  • ABB DSAO120A 3BSE018293R1 Analog Output Module
  • ABB CI869K01 3BSE049110R1 Ethernet Interface
  • ABB CI522A 3BSE018460R1 PROFIBUS DP Master
  • GUTOR OP6257 Rectifier Control Unit
  • Meggitt C327845-11 Gas Shutoff Valve
  • ABB SACO64D4 4-Pole Digital Annunciator Unit
  • ABB CI522AK04 3BSE018451R1 PROFIBUS DP Module
  • ABB DSAI130DK01 3BSE020828R1 Temperature Input Module
  • ABB CI546 3BSE012610R1 PROFIBUS DP Master Module
  • ABB SC510 3BSE003832R1 Compact PLC Controller
  • ABB CI540 3BSE001077R1 PROFIBUS DP Slave Module
  • ABB CI532V03 3BSE003828R1 AF 100 PROFIBUS DP Master
  • ABB DSBC172 57310256-EL Digital Input Terminal Base
  • Rexroth VT2000-5X Frequency Converter AC Drive
  • GE MAVS01L1AB0751D-140393N Soft Starter
  • ABB REF615 HBFDACADNAA1BCN1XE Relay
  • ABB SACO16D1 1-Pole Digital Annunciator Unit
  • ABB UNITROL 1000 3BHE014557R0003 Static Excitation System
  • Woodward 8273-1011 Electro-Hydraulic Actuator
  • Eaton MC2-442-57CQB-1-2A Molded Case Circuit Breaker
  • Siemens 3AY1715-6L VS30029P VS30041 Auxiliary Contact Block
  • ABB PCD235B101 3BHE032025R0101 Digital I/O Control Module
  • Socapel PAM-R1R-H8F-AP-P V10800 Programmable Axis Manager
  • Rexroth VT-HNC100-1-23N-08-P-0 Digital Hydraulic Amplifier
  • Woodward 5448-890 SPM-D10 Digital Synchronizer
  • TDK-Lambda HWS1500-24 Industrial Power Supply
  • Land M2300/1100C-V Infrared Pyrometer
  • Lantronix 080-332-000-R Industrial Device Server
  • LED E14 3W Miniature LED Lamp
  • LEM LC100S/SP7 Hall Effect Current Sensor
  • Lenel LNL-1320 Dual Reader Interface Module
  • Lenze L5311 Industrial Control Module
  • Lenze EPZ-10203 Safety Controller
  • Lenze EPL10200 Industrial Drive Module
  • Lenze EPL-10200-XX Drive Controller
  • Lam Research 810-801237-021 Industrial Part
  • Lam Research 810-073479-215 Precision Part
  • Lam Research 853-001983-110 Assembly Data
  • Lam Research 810-017034-005 Semiconductor Part
  • Lambda LZS-A1500-3 AC-DC Power Module
  • Lambda LZS-1500-3 Industrial Power Supply
  • LAM 810-072907-005 Chamber Interface Control Module
  • LAM 810-068158-014 Semiconductor Process Control Module
  • LAM 810-800081-018 Vacuum System Interface Module
  • LAM 810-068158-013 Semiconductor Control Module
  • Leybold CM330 Vacuum Gauge Controller
  • Leybold 850-400-G1 Vacuum Pump Module
  • LIFTMASTER 71-1550B18LGH Electric Actuator
  • LKB Bromma 2211 Pressure Sensor
  • LLASERGAS AO2000 LS25 12944-E Gas Analyzer Module
  • Load Controls PH-3A Three-Phase Power Sensor
  • Ludlum 2401-P Pancake GM Survey Meter
  • LUST VF1410LHFS41 AC Servo Drive
  • LUTZE UBE-FL/34M Terminal Block Contact
  • Marposs E78 Dynamic Balancing Controller
  • LENZE E84AVSCE1534VX0 Servo Drive Controller
  • LENZE EVF8212-E Frequency Inverter Drive
  • LENZE EA-4/10 Drive Expansion Module
  • LENZE BG10 Brake Module
  • LEUZE DDLS 200/200.1-50-M12 Data Link Data
  • LEUZE DDLS 200/200.2-50-M12 Optical Data
  • LEYBOLD TURBOVAC 361 Turbomolecular Pump
  • LEYBOLD TR211 Vacuum Controller Data
  • LEYBOLD SV40BI Rotary Vane Pump Specifications
  • LEYBOLD PR25 Vacuum Pressure Sensor Data
  • MARPOSS E9066 Precision Measurement Control Unit
  • MATROX Y7116-04 REV A Industrial Vision Processing Board
  • MATROX Y7116-01 REV A Industrial Video Processing Board
  • MCS SA1000 Industrial Signal Amplifier Module
  • MECS CS-1000 Control System Hardware Data
  • MECS UTX1010 Industrial Control Module
  • MECS UTX-1000A Industrial Module
  • MECS UTV-F2500HA High-Power Thyristor Data
  • MECS EXT-2 Advanced Expansion Interface
  • MECS EXT-1 Interface Extension Module
  • MECS CPU-1000 Industrial PLC Controller
  • MEN A201SR04 Embedded Computer
  • MERAK 681H10078 681K10078 681K10079 Control Modules
  • Mercury Step C-663 Stepper Motor Controller
  • MERLIN GERIN MX+0F 26948 Shunt Trip Release
  • MERLIN GERIN 32570 Miniature Circuit Breaker