After each of the following modifications, safety checks and risk assessments must be conducted again:
Replace the safety light curtain or its components
Change the wiring method (such as changing from no coding to coding mode)
Change mechanical structure or safety distance
9. Summary of Technical Parameters
9.1 Electrical Parameters
Supply voltage: 24 VDC, tolerance -25%/+20%
Residual ripple: 5%
Maximum power consumption (OSSD OFF): 2.5W
OSSD switch current: 100mA/channel
OSSD voltage drop: 1.5V
Maximum test pulse width: 300 μ s
9.2 Environmental and mechanical parameters
Protection level: IP65
Vibration resistance: 10-150Hz, 0.75mm amplitude, 0.2g acceleration
Impact resistance: Standard bracket 10g/16ms, expansion bracket 50g/11ms
Material: The shell is made of aluminum alloy, and the end cap is made of die cast zinc
Weight: 150mm protection height 1.82kg, 1800mm protection height 5.06kg