Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

ABB RELION ® 615 series REU615 voltage protection and control relay

来源: | 作者:FAN | 发布时间 :2025-07-08 | 534 次浏览: | Share:

ABB RELION ®  615 series REU615 voltage protection and control relay

Product overview

REU615 is ABB RELION ®  There are two standard configurations (A and B) for voltage protection and control relays in the 615 series. Configuration A is applicable to voltage and frequency based protection schemes in power systems and distribution systems, including networks with distributed generation; Configuration B is specifically designed for automatic voltage regulation of power transformers equipped with on load tap changers. Both configurations have additional functions such as circuit breaker control, measurement, and monitoring, and adopt a compact withdrawable unit design, fully utilizing the potential of IEC 61850 standard in communication and interoperability between substation automation equipment.

REX615 - Protection and control products for power distribution ...

Core functions and features

Protection function

Voltage protection: including three-phase overvoltage protection (3U>), three-phase undervoltage protection (3U<), residual overvoltage protection (Uo>), positive sequence undervoltage protection (U1<), negative sequence overvoltage protection (U2>), etc., which can cope with different voltage abnormal situations.

Frequency protection: It has over/under frequency (f>/f<) and frequency change rate (df/dt) protection functions to prevent damage to network components caused by abnormal system frequency.

Overcurrent protection: Configuration B includes three-phase non directional overcurrent protection (low, high, instantaneous stages) for detecting overcurrent and short circuit faults.

Thermal overload protection: Configure B's three-phase thermal overload protection (with two time constants) to monitor the thermal stress of the transformer winding and prevent premature aging of the winding insulation.

Other protections include arc protection (optional configuration A), multi-purpose protection, and other functions.

Control function: Supports circuit breaker control, isolation switch control, grounding switch control, on load tap changer control, etc., which can achieve effective control and interlocking of primary equipment.

Measurement function: It can measure various electrical parameters such as three-phase current, voltage, residual current, residual voltage, sequence current, sequence voltage, power, energy, frequency, etc. It can also perform RTD/mA measurement (configuration B is optional).

Data recording and event recording

Disturbance recorder: capable of recording analog and digital channel data, with sampling frequency varying depending on the rated frequency, adjustable recording length, and diverse triggering methods.

Fault record: Record fault related data for easy fault analysis and diagnosis.

Load curve recording: The load history of the corresponding feeder can be observed.

Communication function: Supports multiple communication protocols, including IEC 61850 (supporting Edition 2), IEC 61850-9-2 LE (process bus) IEC 60870-5-103、Modbus ®、 DNP3, etc., have Ethernet redundancy (HSR, PRP), self-healing Ethernet ring and other functions, which can achieve secure communication.

Human Computer Interaction: Equipped with Local HMI (LHMI) and Web HMI (WHMI), LHMI includes a display screen, LED indicator lights, and keyboard for easy local settings, monitoring, and control; WHMI can securely access relays through a web browser.

Authorization and Audit Tracking: Four predefined user categories (VIEWER, OPEROTOR, ENGINEER, and ADMINIST) are defined, each with different permissions; Equipped with audit tracking function to record critical systems and security related events.


Standard configuration

Configuration A

Application scenario: It is applicable to voltage protection and synchronization check in the medium voltage network. It can handle the fault caused by abnormal voltage in the power system, and can handle the synchronization and power on check of two galvanically interconnected networks.

Main functions: including voltage protection (overvoltage, undervoltage, residual voltage, sequence voltage, etc.), frequency protection, load shedding and recovery, arc protection (optional), synchronous inspection, as well as control functions such as circuit breakers, isolation switches, grounding switches, etc.

Configuration B

Application scenario: Used for automatic voltage regulation of power transformers equipped with on load tap changers, including three-phase non directional overcurrent protection, three-phase undervoltage and overvoltage protection, etc.

Main functions: In addition to voltage protection, overcurrent protection, thermal overload protection, etc., it also has functions such as on load tap changer control and voltage regulation, tap changer position indication, etc. The optional RTD/mA input module is used for temperature measurement, etc.


Technical parameters and requirements

1、 Requirements for measuring transformers

(1) Current Transformer (CT)

Requirements for CT for overcurrent protection

Accuracy level and accuracy limit coefficient: The accuracy level of current transformers used for protection is usually represented by "P" (meaning protection), followed by the number indicating the maximum allowable composite error at the rated accuracy limit current. For example, 5P10 represents an accuracy level of 5P and an accuracy limit coefficient of 10. Both 5P and 10P levels are suitable for non directional overcurrent protection, with 5P level having higher accuracy.

Actual accuracy limit coefficient calculation: The actual accuracy limit coefficient (F a) is related to the rated accuracy limit coefficient (F n), CT rated load (S n), CT internal secondary load (S in), and actual external load (S). The calculation formula is:

F a ≈ F n × ∣ S n+S ∣∣ S in+S n ∣ CT selection principle: For non directional overcurrent protection, it is recommended to choose a CT with an actual accuracy limit factor of at least 20. The rated primary current (I 1n) of the CT should meet the requirement of I 1n>I kmax/100 (I kmax is the maximum fault current) to avoid exceeding the thermal and dynamic intensity of the input current measurement of the protective relay.

Suggestion for starting current setting: If I kmin is the lowest current that should be activated during the highest set overcurrent stage, the starting current should be set to:

The current starting value, with a coefficient of 0.7, takes into account protection relay error, CT error, and short-circuit calculation deviation.


2、 Input parameters

(1) Incentive input

Phase current (configuration B)

Terminals: X120:7-8 (IL1), X120:9-10 (IL2), X120:11-12 (IL3)

Can be used for single-phase or two-phase applications, where some excitation inputs can be left vacant, but at least X120:7-8 needs to be connected

Residual current (configuration B)

Terminal: X120:13-14 (Io)

Phase voltage (configuration B)

Terminals: X120:1-2 (U1), X120:3-4 (U2), X120:5-6 (U3)

Phase voltage (configuration A)

Terminals: X130:11-12 (U1), X130:13-14 (U2), X130:15-16 (U3)

SECRSYN1 reference voltage (configuration A)

Terminal: X130:9-10 (U12B)

Residual voltage (configuration A)

Terminal: X130:17-18 (Uo)

(2) RTD/mA input (configuration B optional)

Terminals and corresponding functions:

X130:1-2:mA1(AI1)

X130:3-4:mA2(AI2)

X130:5-6:RTD1(AI3)

X130:7-8:RTD2(AI4)

X130:9-10:RTD3(AI5)

X130:11: RTD channels 1-3 common ground

X130:12: RTD channels 4-6 common ground

X130:13-14:RTD4(AI6)

X130:15-16:RTD5(AI7)

X130:17-18:RTD6(AI8)


  • EMERSON A6740 Displacement Case Expansion Monitor
  • EMERSON A6312/06 Speed Monitoring Module
  • EMERSON KJ4001X1-BE1 DeltaV Carrier Module
  • EMERSON SE3008 KJ2005X1-MQ2 DeltaV Controller
  • EMERSON KJ4001X1-CA1 DeltaV Terminal Block
  • Emerson PR6423/00R-010 CON031 Eddy Current Probe System
  • Emerson A6824 9199-00090 Operator Workstation
  • Emerson A6410 9199-00005 Operator Workstation
  • Emerson A6110 9199-00001 Operator Workstation
  • Emerson 9199-00002 A6120 Operator Workstation
  • Emerson KJ3002X1-BF1 12P1732X042 FIELDVUE DVC6200
  • Emerson 5X00500G01 Ovation Analog Output Module
  • Emerson VE4001S2T2B4 DeltaV Controller Module
  • Emerson 5X00502G01 Ovation Analog Input Module
  • Emerson A6824R 9199-00098-13 Operator Workstation
  • EMERSON A6140 9199-00058 Dual Channel Monitor
  • EMERSON VE3007 KJ2005X1-BA1 DeltaV Controller
  • EMERSON DB1-1 Connection Termination Block
  • EMERSON PMC-IO-ADAPTER Mezzanine Interface Card
  • EMERSON L0115012 L0115032 Solenoid Valve Components
  • Emerson A6410 Large Operator Workstation
  • Emerson A6210 Operator Workstation
  • Emerson 1C31232G02 Ovation Controller Module
  • Emerson 5X00106G02 Ovation Power Supply Module
  • Emerson 5X00106G01 Ovation Power Supply Module
  • EMERSON PMC-IO-PROZESSOR High-Speed I/O Module
  • EMERSON PMC PROFINET Communication Module
  • EMERSON MVME7100-0171 VMEbus Single Board Computer
  • EMERSON SE3008 KJ2005X1-SQ1 DeltaV MQ Controller
  • EMERSON PR6423/002-041 Eddy Current Displacement Sensor
  • Emerson SE4006P2 Serial Interface Module
  • Emerson KJ2201X1-HA1 Analog Input Module
  • EMERSON CE4001S2T2B4 DeltaV I/O Interface Module
  • EMERSON CE4003S2B1 DeltaV Controller
  • EMERSON KJ2003X1-BA2 DeltaV I/O Carrier
  • Enterasys A4H124-24TX P0973JM 24-Port Fast Ethernet Switch Module
  • Enterasys A2H254-16 P0973BK 16-Port Fast Ethernet Switch Module
  • Enterasys A4H254-8F8T P0973JP Matrix E5 Switch Module
  • Enterasys SSA-T8028-0652 P0973LN SecureStack Gigabit Switch
  • Enterasys A2H124-24FX P0973BJ
  • Enterasys SSA-AC-PS-625W P0973LQ Power Supply
  • Enterasys A2H124-24FX-RH Fiber Fast Ethernet Switch
  • Enterasys A2H254-16-RH Fast Ethernet Switch
  • Enterasys C2G170-24 P0973BL Stackable Gigabit Switch
  • Enterasys STK-RPS-150PS P0973BP Redundant Power Supply
  • ENTERASYS A4H124-24FX P0973JN SecureStack A4 Fiber Switch
  • ENTERASYS A4H124-24TX SecureStack A4 Ethernet Switch
  • ENTERASYS A2H124-24FX SecureStack A2 Fiber Switch
  • ENTERASYS A2H254-16 SecureStack A2 Managed Switch
  • ENTERASYS A4H254-8F8T SecureStack A4 Managed Switch
  • Enterasys C2RPS-CHAS2 Redundant Power System Chassis
  • Enterasys A2H124-24 Managed Ethernet Switch
  • EPRO PR6423/003-030-CN Hazardous Area Sensor
  • EPRO PR6424/012-000 Eddy Current Displacement Probe
  • EPRO PR6424/013-130 + CON021 Eddy Current Sensor System
  • EPRO PR6424/014-040 11mm Eddy Current Probe
  • EPRO PR6423/001-000 Eddy Current Sensor Probe
  • EPRO PR6423/010-000-CN Eddy Current Probe
  • EPRO MMS6823 9100-00001-05 Output Module
  • EPRO CON011 9200-00001N Signal Converter
  • EPRO MMS6120 Dual Channel Speed Monitor 9100-00002-10
  • EPRO MMS6120 Dual Channel Overspeed Protection Monitor 9100-00002C-08
  • EPRO PR6423 and PR6424 Eddy Current Displacement Probes
  • EPRO PR9268/300-000 Seismic Velocity Sensor
  • EPRO MMS3120/022-000 Dual Channel Vibration Monitor 9100-03047-01
  • EPRO MMS6823R 9100-00001-06 Dual Channel Module
  • EPRO PR6423/10R-030-CN Displacement Sensor
  • EPRO PR6423 Eddy Current Displacement Sensor
  • EPRO PR6423/002-030-CN+CON021 Eddy Current Sensor
  • EPRO PR9376/20 Contactless Speed Sensor
  • EPRO PR6423/002-001-CN Eddy Current Probe
  • EPRO RSM020 Relay Output Module
  • EPRO SDM010 Signal Distribution Module
  • EPRO PR6423/010-010-CN Eddy Current Sensor
  • FANUC A81L-0001-0165 Servo Motor Cable
  • FANUC A05B-2452-C900 Teach Pendant Cable
  • FANUC A90L-0001-0422#50 Cooling Fan 9WF0624H7D05
  • FANUC A860-0326-T103 Alpha iA64 Pulse Coder
  • FANUC A860-0315-T101 Alpha i Pulse Coder
  • FANUC A860-0302-T001 Alpha Series Pulse Coder
  • FANUC A230-0604-X003 Operator Panel
  • FANUC A20B-8200-0927 I/O Link Module
  • FANUC A20B-2902-0290/08C Communication PCB
  • FANUC A20B-2901-0763/02A I/O PCB Module
  • FANUC A20B-2901-066 Main PCB Board
  • FANUC A20B-2002-0040/07DR Servo Control PCB
  • FANUC A16B-2203-0073/02A Power Supply PCB
  • FANUC A06B-6114-H106 Alpha i Servo Amplifier
  • FANUC A06B-6089-H104 Alpha Servo Amplifier SVM1-80
  • FANUC A06B-6079-H208 Alpha Servo Amplifier Module
  • FANUC A06B-6079-H106 Servo Amplifier
  • FANUC A06B-6077-H106 Servo Amplifier
  • FANUC A06B-0116-B203#0100 Servo Motor
  • HIMA F3DIO20/802 Digital I/O Module 982200442
  • HIMA 80105 Power Supply Module 984080105
  • HIMA X-DO2401 Digital Output Module 985210203
  • HIMA X-DI3201 Digital Input Module 985210201
  • HIMA F-PWR02 Power Supply Module for F-Series
  • HIMA K1412B / H51q-HRS Safety Controller 996141261 / 997205233
  • HIMA K7214 Power Supply Module 996721402
  • HIMA TM202-A00-B00-C00-D00-E00-G00 Analog Termination
  • HIMA TM521 Digital Input Termination Module
  • HIMA TM591-B00-G00 Termination Module HIMax System
  • HIMA KFD2-STC4-Ex1 SMART Transmitter Power Supply
  • HIMA KFD2-VR4-Ex1.26 Voltage Repeater Isolated Barrier
  • HIMA SB3073-EX Intrinsically Safe Barrier Module
  • HIMA H6200A Terminal Module for Safety I/O
  • HIMA Z7130 Power Supply Distribution Module
  • HIMA F8652E 984865264 Central Module HIQuad H51q
  • HIMA F8627 984862702 Communication Module HIQuad System
  • HIMA H41q-HS High-Speed Safety Controller B4237-1 997104237
  • HIMA F8652X Central Processing Unit 984865265
  • HIMA H4135 Safety Logic Solver 992413502
  • HIMA H51q-H High-Integrity Safety Controller B5233-2 997235233
  • HIMA F6217 Safety Controller 984621702
  • HIMA F3330 984333002 Digital Output Module
  • HIMA F7553 984755302 Communication Module
  • HIMA F7131 Power Supply Module
  • HIMA X-DO1201 985210204 Digital Output Module
  • HIMA H51q-HRS B5233-2 Safety Controller Module
  • HIMA F3231 16-Channel Digital Input Module
  • HIMA K9203A (996920360) Safety Relay Module
  • HIMA H51q-HS B5233-1 Safety Control System
  • HIMA F7131 Power Supply Monitoring Module
  • HIMA F8620/11 Central Module for HIQuad Systems
  • HIMA X-FAN 18 03 Redundant Fan Module for Safety Systems
  • HITACHI LYD000A Digital Input Module 8-Channel
  • HITACHI PS6000 Heavy-Duty Power Supply 24VDC 10A