AB 1785-PFB PLC-5 PROFIBUS Local Station Manager

Technical specifications

Communication interface specifications: Connected via RS-232 cable, one end of the cable is connected to the computer, the other end is connected to the 9-pin female connector, the specific pin definition is clear, Pin 4 is used for the module to transmit data to the computer (TX), Pin 3 is used for the computer to receive data to the module (RX), Pin 1 as the data ground (GND). This shows that the device uses the RS-232 standard interface for data transmission, this interface is widely used in the field of industrial control, has a certain degree of versatility and stability, to meet the basic data communication needs between the device and the computer.


Software environment requirements: need to run on Microsoft Windows 3.1 or higher version of the operating system. This requirement restricts the scope of the software environment used, ensures compatibility with specific operating systems, and also implies that the software architecture and functional design of the Local Station Manager are developed based on the characteristics and standards of these operating systems, and users need to ensure that the computer meets the conditions of this software environment when using it.


Bus Parameters: Bus parameters can be set, including local address, baud rate, maximum address and message timeout. Baud rate is commonly set to 500Kbaud, 187.5Kbaud and so on. These parameters can be set for the user according to different industrial field environment and equipment requirements for flexible configuration provides the possibility of different baud rate settings will affect the speed and stability of data transmission, the user can choose the optimal configuration according to the actual situation.


Module Status Indication: The module status is displayed through a special window, which contains various statuses, such as ‘Operational’ indicates that the module has been configured for communication; ‘No Communication’ indicates that the module is busy, No Communication’ indicates that the module is busy, an error has occurred, or the RS-232 cable is not connected. These status indicators provide users with intuitive information about the module's operation, which helps to find and solve problems in time, and to judge whether the module's working status is normal or not, so as to take corresponding measures.


Prerequisites for Use and Connection and Installation: To use the Local Station Manager, you need to master the operation of Microsoft Windows 3.1 or later, and connect the computer and the PROFIBUS coprocessor with the RS-232 cable, and connect them according to the specific pins. Afterwards, insert the floppy diskette of the Local Station Manager into the drive of the computer and install it by entering the installation commands via the ‘Execute’ option in the ‘File’ menu. The installer will copy the files to the default directory and you can choose whether or not to modify the SYSTEM.INI file. file.


Basic operation guide

Open and Language Selection: After starting Windows, double click the AB_PROFIBUS icon to open the Local Station Manager, and then double click the Local Station Manager icon or press the Enter key to select the language from English, German and French to enter the main interface.

Use of help tools: Click the ‘?’ icon to get context help, press F1 key or select ‘Index’ in ‘Help’ menu to view the help index, you can continue to browse or exit the help tool by menu operation.

Communication Port Selection: Click the ‘Settings’ icon or select ‘COM Port’ from the ‘Settings’ menu to select the communication port of the computer to which the RS-232 cable is connected. Three windows will be displayed, including ‘Module Status’, in which ‘Module Status’ window will display different status of the module.


Function operation details

Check battery level and switch: Click ‘MOD INFO’ icon or select ‘Module Info’ from ‘Info’ menu to check the battery level and switch setting according to the module status. If the module status is ‘no communication’, you need to check the connection and port settings.

Setting and verifying bus parameters: Click ‘Bus’ icon or select ‘Bus Parameters’ from ‘Configuration’ menu, you can choose default parameters or manually input new parameters, click ‘OK’ before you need to check the connection and port settings. You can select the default parameters or manually enter new parameters, set switch 2 to ‘Off’ before clicking ‘OK’ to verify the new parameters.

Monitor system events: Click ‘EVT’ icon or select ‘Module Events’ from ‘Monitor’ menu, you can view the time, source and explanation of module events. By comparing the time, you can determine the interval of the event, and according to the source and explanation, you can analyse the cause of the event.


Other operations

Reset operation: Click ‘RES MOD’ icon or select ‘Module Reset’ from ‘Monitor’ menu to reset the module, click ‘RES COM’ icon or select ‘Module Reset’ from ‘Monitor’ menu to reset the module. Communication can be reset by clicking ‘COM’ icon or selecting ‘Communication Reset’ from ‘Monitor’ menu. The reset operation needs to confirm the prompt message and the LED of the module will change accordingly during the reset process.

  • Bently 3500/15 125840-01 Power Supply Module
  • Bently 24765-02-01 Signal Conditioner Module
  • Bently 330130-085-00-00 Extension Cable
  • Bently 3500/22M 138607-01 Vibration Monitor Module
  • Bently 146031-02 Proximity Probe Sensor
  • BENTLY 330104-00-05-10-02-CN Proximity Probe
  • BENTLY 125768-01 3500 I/O Module Interface
  • BENTLY 3500/92 136180-01 Communication Gateway
  • BENTLY 84152-01 Proximitor Sensor Cable
  • BENTLY 3300/20 Dual Driver Proximitor Housing
  • BENTLY 3300/16-11-01-03-00-00-01 16-Channel Monitor
  • DEIF PPU-3 Power Protection Unit for Genset Control
  • DEIF RMV-112D Reactive Power Divider and Voltage Matching Relay
  • DEIF OPM-1 Output Protection Module for Gensets
  • DEIF IPM-1 Integrated Protection Module for Generators
  • DEIF CM-2 Control Module for Industrial Power Systems
  • DEIF PSM-1 Power System Manager Module
  • DEIF DELOMATIC-3 DGU2 Automatic Generator Control Unit
  • DEIF DLQ144-PC-NB Power Monitoring Meter
  • DEIF DU-2/MKIII Voltage Relay Controller
  • DEIF IOM4.2 Input/Output Module for Power Management
  • DEIF SCM-1 Synchronizing Control Module
  • DEIF GPU/2/GS Genset Parallel Unit Controller
  • EMERSON PR6426/010-110 CON021 Proximity System
  • EMERSON PR6423/011-110+C0N021 Proximity Sensor System
  • DEIF LSU-112DG Load Sharing Unit
  • DEIF PCM4.4 Advanced Power Control Module
  • DEIF TAC-311DG Transducer for AC Voltage
  • DEIF SCM4.1 Engine Start Control Module
  • DEIF PCM4.3 Power Control Module
  • Emerson 2500M/AI4UNIV Universal Analog Input Module
  • Emerson PR6424/011-140 Eddy Current Sensor
  • Emerson KJ3242X1-BK1 12P4711X042 Analog Input Module
  • Emerson FX-316 960132-01 Control Processor Module
  • Emerson KJ4006X1-BD1 Power Supply Module
  • EMERSON 1C31181G01 Ovation Analog Output Module
  • EMERSON CE4003S2B6 DeltaV Analog Module
  • EMERSON KJ4001X1-CK1 DeltaV I/O Carrier Card
  • EMERSON VE4012S2B1 DeltaV I/O Module Specifications
  • EMERSON SS6501T01 DeltaV System Assembly Technical Overview
  • Emerson A6370D/DP Display
  • Emerson P188.R2 Power Supply
  • Emerson A6824R 24-Ch Relay
  • Emerson KJ2201X1-JA1 Serial
  • Emerson VE3008 Main Controller
  • Emerson VE3008 CE3008 KJ2005X1-MQ1 Controller Module
  • Emerson TPMC917 Embedded Processor Module
  • Emerson P152.R4 Industrial Control Module
  • Emerson DA7281520 P152 Power Module
  • Emerson PR6423/008-110 Eddy Current Sensor
  • EMERSON 5X00273G01 Ovation DCS Digital Output Module
  • EMERSON KJ4001X1-NB1 12P3368X012 REV:E Redundant Controller Backplane
  • EMERSON KJ4001X1-NA1 12P3373X012 REV:C Intrinsically Safe Interface
  • EMERSON KJ4001X1-BE1 12P0818X072 REV:L DeltaV I/O Carrier
  • EMERSON KJ2221X1-BA1 DeltaV SIS SISNet Repeater Module
  • EMERSON PR6423/000-131 Eddy Current Sensor
  • EMERSON 5X00790G01 Ovation Digital Output Module
  • EMERSON 5X00846G01 Ovation Analog Input Module
  • EMERSON KJ4110X1-BA1 DeltaV Power Supply Base
  • EMERSON CSI3125 A3125/022-020 Dual Channel Monitor
  • EMERSON A6740 Displacement Case Expansion Monitor
  • EMERSON A6312/06 Speed Monitoring Module
  • EMERSON KJ4001X1-BE1 DeltaV Carrier Module
  • EMERSON SE3008 KJ2005X1-MQ2 DeltaV Controller
  • EMERSON KJ4001X1-CA1 DeltaV Terminal Block
  • Emerson PR6423/00R-010 CON031 Eddy Current Probe System
  • Emerson A6824 9199-00090 Operator Workstation
  • Emerson A6410 9199-00005 Operator Workstation
  • Emerson A6110 9199-00001 Operator Workstation
  • Emerson 9199-00002 A6120 Operator Workstation
  • Emerson KJ3002X1-BF1 12P1732X042 FIELDVUE DVC6200
  • Emerson 5X00500G01 Ovation Analog Output Module
  • Emerson VE4001S2T2B4 DeltaV Controller Module
  • Emerson 5X00502G01 Ovation Analog Input Module
  • Emerson A6824R 9199-00098-13 Operator Workstation
  • EMERSON A6140 9199-00058 Dual Channel Monitor
  • EMERSON VE3007 KJ2005X1-BA1 DeltaV Controller
  • EMERSON DB1-1 Connection Termination Block
  • EMERSON PMC-IO-ADAPTER Mezzanine Interface Card
  • EMERSON L0115012 L0115032 Solenoid Valve Components
  • Emerson A6410 Large Operator Workstation
  • Emerson A6210 Operator Workstation
  • Emerson 1C31232G02 Ovation Controller Module
  • Emerson 5X00106G02 Ovation Power Supply Module
  • Emerson 5X00106G01 Ovation Power Supply Module
  • EMERSON PMC-IO-PROZESSOR High-Speed I/O Module
  • EMERSON PMC PROFINET Communication Module
  • EMERSON MVME7100-0171 VMEbus Single Board Computer
  • EMERSON SE3008 KJ2005X1-SQ1 DeltaV MQ Controller
  • EMERSON PR6423/002-041 Eddy Current Displacement Sensor
  • Emerson SE4006P2 Serial Interface Module
  • Emerson KJ2201X1-HA1 Analog Input Module
  • EMERSON CE4001S2T2B4 DeltaV I/O Interface Module
  • EMERSON CE4003S2B1 DeltaV Controller
  • EMERSON KJ2003X1-BA2 DeltaV I/O Carrier
  • Enterasys A4H124-24TX P0973JM 24-Port Fast Ethernet Switch Module
  • Enterasys A2H254-16 P0973BK 16-Port Fast Ethernet Switch Module
  • Enterasys A4H254-8F8T P0973JP Matrix E5 Switch Module
  • Enterasys SSA-T8028-0652 P0973LN SecureStack Gigabit Switch
  • Enterasys A2H124-24FX P0973BJ
  • Enterasys SSA-AC-PS-625W P0973LQ Power Supply
  • Enterasys A2H124-24FX-RH Fiber Fast Ethernet Switch
  • Enterasys A2H254-16-RH Fast Ethernet Switch
  • Enterasys C2G170-24 P0973BL Stackable Gigabit Switch
  • Enterasys STK-RPS-150PS P0973BP Redundant Power Supply
  • ENTERASYS A4H124-24FX P0973JN SecureStack A4 Fiber Switch
  • ENTERASYS A4H124-24TX SecureStack A4 Ethernet Switch
  • ENTERASYS A2H124-24FX SecureStack A2 Fiber Switch
  • ENTERASYS A2H254-16 SecureStack A2 Managed Switch
  • ENTERASYS A4H254-8F8T SecureStack A4 Managed Switch
  • Enterasys C2RPS-CHAS2 Redundant Power System Chassis
  • Enterasys A2H124-24 Managed Ethernet Switch
  • EPRO PR6423/003-030-CN Hazardous Area Sensor
  • EPRO PR6424/012-000 Eddy Current Displacement Probe
  • EPRO PR6424/013-130 + CON021 Eddy Current Sensor System
  • EPRO PR6424/014-040 11mm Eddy Current Probe
  • EPRO PR6423/001-000 Eddy Current Sensor Probe
  • EPRO PR6423/010-000-CN Eddy Current Probe
  • EPRO MMS6823 9100-00001-05 Output Module
  • EPRO CON011 9200-00001N Signal Converter
  • EPRO MMS6120 Dual Channel Speed Monitor 9100-00002-10
  • EPRO MMS6120 Dual Channel Overspeed Protection Monitor 9100-00002C-08
  • EPRO PR6423 and PR6424 Eddy Current Displacement Probes
  • EPRO PR9268/300-000 Seismic Velocity Sensor
  • EPRO MMS3120/022-000 Dual Channel Vibration Monitor 9100-03047-01
  • EPRO MMS6823R 9100-00001-06 Dual Channel Module
  • EPRO PR6423/10R-030-CN Displacement Sensor
  • EPRO PR6423 Eddy Current Displacement Sensor