AB 1785-PFB PLC-5 PROFIBUS Local Station Manager

来源: | 作者:FAN | 发布时间 :2025-04-22 | 497 次浏览: | Share:

AB 1785-PFB PLC-5 PROFIBUS Local Station Manager

Technical specifications

Communication interface specifications: Connected via RS-232 cable, one end of the cable is connected to the computer, the other end is connected to the 9-pin female connector, the specific pin definition is clear, Pin 4 is used for the module to transmit data to the computer (TX), Pin 3 is used for the computer to receive data to the module (RX), Pin 1 as the data ground (GND). This shows that the device uses the RS-232 standard interface for data transmission, this interface is widely used in the field of industrial control, has a certain degree of versatility and stability, to meet the basic data communication needs between the device and the computer.


Software environment requirements: need to run on Microsoft Windows 3.1 or higher version of the operating system. This requirement restricts the scope of the software environment used, ensures compatibility with specific operating systems, and also implies that the software architecture and functional design of the Local Station Manager are developed based on the characteristics and standards of these operating systems, and users need to ensure that the computer meets the conditions of this software environment when using it.


Bus Parameters: Bus parameters can be set, including local address, baud rate, maximum address and message timeout. Baud rate is commonly set to 500Kbaud, 187.5Kbaud and so on. These parameters can be set for the user according to different industrial field environment and equipment requirements for flexible configuration provides the possibility of different baud rate settings will affect the speed and stability of data transmission, the user can choose the optimal configuration according to the actual situation.


Module Status Indication: The module status is displayed through a special window, which contains various statuses, such as ‘Operational’ indicates that the module has been configured for communication; ‘No Communication’ indicates that the module is busy, No Communication’ indicates that the module is busy, an error has occurred, or the RS-232 cable is not connected. These status indicators provide users with intuitive information about the module's operation, which helps to find and solve problems in time, and to judge whether the module's working status is normal or not, so as to take corresponding measures.


Prerequisites for Use and Connection and Installation: To use the Local Station Manager, you need to master the operation of Microsoft Windows 3.1 or later, and connect the computer and the PROFIBUS coprocessor with the RS-232 cable, and connect them according to the specific pins. Afterwards, insert the floppy diskette of the Local Station Manager into the drive of the computer and install it by entering the installation commands via the ‘Execute’ option in the ‘File’ menu. The installer will copy the files to the default directory and you can choose whether or not to modify the SYSTEM.INI file. file.


Basic operation guide

Open and Language Selection: After starting Windows, double click the AB_PROFIBUS icon to open the Local Station Manager, and then double click the Local Station Manager icon or press the Enter key to select the language from English, German and French to enter the main interface.

Use of help tools: Click the ‘?’ icon to get context help, press F1 key or select ‘Index’ in ‘Help’ menu to view the help index, you can continue to browse or exit the help tool by menu operation.

Communication Port Selection: Click the ‘Settings’ icon or select ‘COM Port’ from the ‘Settings’ menu to select the communication port of the computer to which the RS-232 cable is connected. Three windows will be displayed, including ‘Module Status’, in which ‘Module Status’ window will display different status of the module.


Function operation details

Check battery level and switch: Click ‘MOD INFO’ icon or select ‘Module Info’ from ‘Info’ menu to check the battery level and switch setting according to the module status. If the module status is ‘no communication’, you need to check the connection and port settings.

Setting and verifying bus parameters: Click ‘Bus’ icon or select ‘Bus Parameters’ from ‘Configuration’ menu, you can choose default parameters or manually input new parameters, click ‘OK’ before you need to check the connection and port settings. You can select the default parameters or manually enter new parameters, set switch 2 to ‘Off’ before clicking ‘OK’ to verify the new parameters.

Monitor system events: Click ‘EVT’ icon or select ‘Module Events’ from ‘Monitor’ menu, you can view the time, source and explanation of module events. By comparing the time, you can determine the interval of the event, and according to the source and explanation, you can analyse the cause of the event.


Other operations

Reset operation: Click ‘RES MOD’ icon or select ‘Module Reset’ from ‘Monitor’ menu to reset the module, click ‘RES COM’ icon or select ‘Module Reset’ from ‘Monitor’ menu to reset the module. Communication can be reset by clicking ‘COM’ icon or selecting ‘Communication Reset’ from ‘Monitor’ menu. The reset operation needs to confirm the prompt message and the LED of the module will change accordingly during the reset process.

  • EPRO MMS6120 Dual Channel Speed Monitor 9100-00002-10
  • EPRO MMS6120 Dual Channel Overspeed Protection Monitor 9100-00002C-08
  • EPRO PR6423 and PR6424 Eddy Current Displacement Probes
  • EPRO PR9268/300-000 Seismic Velocity Sensor
  • EPRO MMS3120/022-000 Dual Channel Vibration Monitor 9100-03047-01
  • EPRO MMS6823R 9100-00001-06 Dual Channel Module
  • EPRO PR6423/10R-030-CN Displacement Sensor
  • EPRO PR6423 Eddy Current Displacement Sensor
  • EPRO PR6423/002-030-CN+CON021 Eddy Current Sensor
  • EPRO PR9376/20 Contactless Speed Sensor
  • EPRO PR6423/002-001-CN Eddy Current Probe
  • EPRO RSM020 Relay Output Module
  • EPRO SDM010 Signal Distribution Module
  • EPRO PR6423/010-010-CN Eddy Current Sensor
  • FANUC A81L-0001-0165 Servo Motor Cable
  • FANUC A05B-2452-C900 Teach Pendant Cable
  • FANUC A90L-0001-0422#50 Cooling Fan 9WF0624H7D05
  • FANUC A860-0326-T103 Alpha iA64 Pulse Coder
  • FANUC A860-0315-T101 Alpha i Pulse Coder
  • FANUC A860-0302-T001 Alpha Series Pulse Coder
  • FANUC A230-0604-X003 Operator Panel
  • FANUC A20B-8200-0927 I/O Link Module
  • FANUC A20B-2902-0290/08C Communication PCB
  • FANUC A20B-2901-0763/02A I/O PCB Module
  • FANUC A20B-2901-066 Main PCB Board
  • FANUC A20B-2002-0040/07DR Servo Control PCB
  • FANUC A16B-2203-0073/02A Power Supply PCB
  • FANUC A06B-6114-H106 Alpha i Servo Amplifier
  • FANUC A06B-6089-H104 Alpha Servo Amplifier SVM1-80
  • FANUC A06B-6079-H208 Alpha Servo Amplifier Module
  • FANUC A06B-6079-H106 Servo Amplifier
  • FANUC A06B-6077-H106 Servo Amplifier
  • FANUC A06B-0116-B203#0100 Servo Motor
  • HIMA F3DIO20/802 Digital I/O Module 982200442
  • HIMA 80105 Power Supply Module 984080105
  • HIMA X-DO2401 Digital Output Module 985210203
  • HIMA X-DI3201 Digital Input Module 985210201
  • HIMA F-PWR02 Power Supply Module for F-Series
  • HIMA K1412B / H51q-HRS Safety Controller 996141261 / 997205233
  • HIMA K7214 Power Supply Module 996721402
  • HIMA TM202-A00-B00-C00-D00-E00-G00 Analog Termination
  • HIMA TM521 Digital Input Termination Module
  • HIMA TM591-B00-G00 Termination Module HIMax System
  • HIMA KFD2-STC4-Ex1 SMART Transmitter Power Supply
  • HIMA KFD2-VR4-Ex1.26 Voltage Repeater Isolated Barrier
  • HIMA SB3073-EX Intrinsically Safe Barrier Module
  • HIMA H6200A Terminal Module for Safety I/O
  • HIMA Z7130 Power Supply Distribution Module
  • HIMA F8652E 984865264 Central Module HIQuad H51q
  • HIMA F8627 984862702 Communication Module HIQuad System
  • HIMA H41q-HS High-Speed Safety Controller B4237-1 997104237
  • HIMA F8652X Central Processing Unit 984865265
  • HIMA H4135 Safety Logic Solver 992413502
  • HIMA H51q-H High-Integrity Safety Controller B5233-2 997235233
  • HIMA F6217 Safety Controller 984621702
  • HIMA F3330 984333002 Digital Output Module
  • HIMA F7553 984755302 Communication Module
  • HIMA F7131 Power Supply Module
  • HIMA X-DO1201 985210204 Digital Output Module
  • HIMA H51q-HRS B5233-2 Safety Controller Module
  • HIMA F3231 16-Channel Digital Input Module
  • HIMA K9203A (996920360) Safety Relay Module
  • HIMA H51q-HS B5233-1 Safety Control System
  • HIMA F7131 Power Supply Monitoring Module
  • HIMA F8620/11 Central Module for HIQuad Systems
  • HIMA X-FAN 18 03 Redundant Fan Module for Safety Systems
  • HITACHI LYD000A Digital Input Module 8-Channel
  • HITACHI PS6000 Heavy-Duty Power Supply 24VDC 10A
  • HITACHI LBT010A Profibus-DP Communication Module
  • HITACHI LPD250A Power Supply Module 24VDC 5A
  • Hitachi LPT020A Industrial Power Module
  • Hitachi LPF240F Industrial Power Module
  • Hitachi LPU100A Industrial Power Unit
  • Hitachi PS6515 Industrial Power Supply Module
  • Hitachi PS6548 Power Supply Module
  • Hitachi LCE250B Communication Module
  • Hitachi LCE250A Communication Module
  • Hitachi LPA302P-1 Analog Input Module
  • Hitachi LPA210A Analog Input Interface
  • Hitachi LPA302A Analog Input Module
  • HITACHI PS6524 Switching Power Supply
  • HITACHI MPD310A Color Touch Screen HMI
  • HITACHI MPD110A Graphic Operator Terminal
  • HITACHI MPD060A Operator Interface Display
  • HITACHI LPP100A Power Supply Module
  • Hitachi LPD200A AC Drive Inverter
  • Hitachi LUD060A AC Drive Inverter
  • Hitachi LPD350A AC Drive Inverter
  • Hitachi LPD220A AC Drive Inverter
  • Hitachi LPA220A AC Drive Inverter
  • Hitachi LPA245A Analog Input Module
  • Hitachi LPU100H Central Processing Unit
  • Hitachi LYT000A Output Module
  • Hitachi LPF240A Power Filter Module
  • Hitachi LUD700A Display and Interface Unit
  • HITACHI LYA100A Analog I/O Module
  • HITACHI LYA220A Analog Input Module
  • HITACHI TD000A Temperature Controller
  • HITACHI LYA210A Analog Output Module
  • HITACHI LYD105A Digital Input Module
  • Hitachi LYA010A AC Drive Inverter
  • HITACHI 2-822037-A Servo Motor Controller
  • Honeywell CC-TAIM01 Analog Input Module
  • Honeywell 2104B2131 Temperature Transmitter
  • Honeywell 05704-A-0146 Industrial Pressure Transmitter
  • Honeywell 05701-A-0351 & 05701-A-0302 Control System Components
  • Honeywell 05701-A-0327 System 57 Interface Module
  • Honeywell S2024-2POS-SW2 Spring Return Actuator
  • Honeywell XFR824A Transformer Module 24VAC 40VA
  • Honeywell 05701-A-0284 & 05701-A-0302 System 57 Control Card
  • Honeywell SC-UCMX02 Universal Controller Module 51307198-276
  • Honeywell ISC-UCMX01 Safety Controller Module 51307195-175
  • Honeywell FC-SCNT02 Field Control Scanner Module
  • Honeywell FC-SCNT01 Field Control Scanner Module
  • Honeywell CC-TUIO41 Universal Input/Output Module
  • Honeywell CC-TUI041 Universal Input Module
  • Honeywell CC-PLAIH51 Analog Input HART Module
  • Honeywell XNX-UTAV-RNIF1 XNX Universal Transmitter
  • Honeywell FTA-T-02 Field Termination Assembly
  • Honeywell LG1093AA24 261A1812P012 Flame Amplifier Module
  • Honeywell CC-TCNT01 51308307-175 ControlNet Interface Module
  • Honeywell CC-TUI041 51306873-176 Universal Input Module
  • Honeywell 1569905-6131140220 Specialized Industrial Component
  • Honeywell QPP-0001 Quad Processor Pack Safety Manager
  • Honeywell PSU-240516 Power Supply Unit 24VDC 5A/16A
  • Honeywell CPB-0001 CPCHAS-0001 Control Processor Chassis
  • Honeywell SDO-0824 CCV1.3 Supervised Digital Output Module
  • Honeywell SDI-1624 CCV1.1 Digital Module