AB 1794-IE8H FLEX I/O 8 Input HART Analog Module

来源: | 作者:FAN | 发布时间 :2025-04-23 | 632 次浏览: | Share:

AB 1794-IE8H FLEX I/O 8 Input HART Analog Module

IMPORTANT USER INFORMATION: Emphasises the differences between solid-state equipment and electromechanical equipment, use of this module is to ensure that the application complies with the requirements, Rockwell Automation is not responsible for consequential damages arising from the use of the equipment, and the manual examples are for reference only and may not be reproduced without permission. Also includes a variety of safety tips, such as operating in hazardous environments and protection against static electricity.

Installation requirements: For use in pollution class 2, overvoltage category II, industrial environments up to 2000 metres above sea level, Group 1, Class A industrial equipment. Installation in a flame-retardant, tool-accessible enclosure to fulfil EMC and safety requirements. Use zinc-plated yellow chrome steel DIN rails for grounding and avoid using other rail materials that may cause poor grounding.


Approved for use in hazardous areas

North America: This module is approved for use in hazardous areas in North America. The product is labelled with a temperature code and the overall temperature code and local regulatory review should be noted when combining devices. When operating in a hazardous area, electrical disconnections or connections are not permitted, and operations such as battery replacement must be performed in a non-hazardous area.

Europe: European Zone 2 approved for use in potentially explosive atmospheres. The device must be used in an enclosure of at least IP54 protection, protected from direct sunlight, protected from voltage overruns, and must have an ATEX approved backplate.


Module Installation

Preparation for Installation: The module must be used with either the 1794-TB3G or 1794-TB3GS terminal block. Ensure that no debris has fallen into the module prior to installation, and disable the keying function in the configuration file when replacing a Series A module with a Series B module.

Installation Procedure: Rotate the key switch to position 3, ensure the Flexbus connector is fully extended, insert the module and align it with the notch for a secure installation. Once installed, remove the end cap plug and connect additional terminal blocks if required.


Wiring and Grounding

Wiring: When connecting a two-wire transmitter device, the input, power, and common wires need to be connected according to specific rules, power supplies can be daisy-chained, and analogue and digital modules should be powered separately to minimise noise interference.

Grounding: All I/O wiring must be shielded and the shield must be externally grounded to the module, e.g. to a busbar or shielded ground feedthrough.

Module Configuration: Set module parameters such as byte order, data format, digital filters, alarm limits, etc. through the configuration mapping table. The data format is various and can be selected according to requirements. Different settings correspond to different functions and value ranges. The configuration in Series A mode is different from that in Series B mode, so it is necessary to pay attention to the applicable scenarios.

HART input data: HART input data contains the main variables of the device and other information, if the HART communication of the channel is disabled, the input data of the channel may be zero, HART input data word contains the communication status, device status, variable acquisition and other information, and each status bit has a clear meaning.

Status Indicators: The module is equipped with 8 red fault indicators, 8 yellow channel indicators and 1 green power indicator. Different indicator statuses reflect different working statuses of the module, such as blinking red indicates channel fault, green light indicates normal power supply, blinking green indicates no Flexbus communication, and yellow light indicates normal HART communication.


Basic Parameters

Number and type of inputs: 8 single-ended, non-isolated analogue input channels, suitable for analogue signal acquisition in various industrial scenarios.

Recommended Terminal Block: Adapted to 1794-TB3G and 1794-TB3GS terminal blocks, ensuring stable connection between the module and external devices.

Key switch position: fixed to 3, used to set the module's working mode.

Enclosure type rating: None (open), to be installed in an additional protective enclosure to meet the protection requirements of the specific application environment.


Electrical parameters

Resolution and data format: resolution up to 16 bits, data format can be configured to support a variety of data representation to meet different measurement and control needs.

Conversion correlation: using the successive approximation method for conversion, can accurately convert analogue signals to digital signals.

Accuracy and anti-interference: Absolute accuracy of 0.1% full scale at 20°C (68°F), 0 - 55°C (32 - 131°F) accuracy drift of 0.05% full scale, with good stability. It has a certain ability to suppress interference signals of different frequencies, which can ensure the accuracy of the signal to a certain extent.

Input Characteristics: Input terminals are specifically numbered for connection to external signals. When the 24V DC power supply is removed, the input resistance becomes 10 kΩ.

  • EMERSON A6740 Displacement Case Expansion Monitor
  • EMERSON A6312/06 Speed Monitoring Module
  • EMERSON KJ4001X1-BE1 DeltaV Carrier Module
  • EMERSON SE3008 KJ2005X1-MQ2 DeltaV Controller
  • EMERSON KJ4001X1-CA1 DeltaV Terminal Block
  • Emerson PR6423/00R-010 CON031 Eddy Current Probe System
  • Emerson A6824 9199-00090 Operator Workstation
  • Emerson A6410 9199-00005 Operator Workstation
  • Emerson A6110 9199-00001 Operator Workstation
  • Emerson 9199-00002 A6120 Operator Workstation
  • Emerson KJ3002X1-BF1 12P1732X042 FIELDVUE DVC6200
  • Emerson 5X00500G01 Ovation Analog Output Module
  • Emerson VE4001S2T2B4 DeltaV Controller Module
  • Emerson 5X00502G01 Ovation Analog Input Module
  • Emerson A6824R 9199-00098-13 Operator Workstation
  • EMERSON A6140 9199-00058 Dual Channel Monitor
  • EMERSON VE3007 KJ2005X1-BA1 DeltaV Controller
  • EMERSON DB1-1 Connection Termination Block
  • EMERSON PMC-IO-ADAPTER Mezzanine Interface Card
  • EMERSON L0115012 L0115032 Solenoid Valve Components
  • Emerson A6410 Large Operator Workstation
  • Emerson A6210 Operator Workstation
  • Emerson 1C31232G02 Ovation Controller Module
  • Emerson 5X00106G02 Ovation Power Supply Module
  • Emerson 5X00106G01 Ovation Power Supply Module
  • EMERSON PMC-IO-PROZESSOR High-Speed I/O Module
  • EMERSON PMC PROFINET Communication Module
  • EMERSON MVME7100-0171 VMEbus Single Board Computer
  • EMERSON SE3008 KJ2005X1-SQ1 DeltaV MQ Controller
  • EMERSON PR6423/002-041 Eddy Current Displacement Sensor
  • Emerson SE4006P2 Serial Interface Module
  • Emerson KJ2201X1-HA1 Analog Input Module
  • EMERSON CE4001S2T2B4 DeltaV I/O Interface Module
  • EMERSON CE4003S2B1 DeltaV Controller
  • EMERSON KJ2003X1-BA2 DeltaV I/O Carrier
  • Enterasys A4H124-24TX P0973JM 24-Port Fast Ethernet Switch Module
  • Enterasys A2H254-16 P0973BK 16-Port Fast Ethernet Switch Module
  • Enterasys A4H254-8F8T P0973JP Matrix E5 Switch Module
  • Enterasys SSA-T8028-0652 P0973LN SecureStack Gigabit Switch
  • Enterasys A2H124-24FX P0973BJ
  • Enterasys SSA-AC-PS-625W P0973LQ Power Supply
  • Enterasys A2H124-24FX-RH Fiber Fast Ethernet Switch
  • Enterasys A2H254-16-RH Fast Ethernet Switch
  • Enterasys C2G170-24 P0973BL Stackable Gigabit Switch
  • Enterasys STK-RPS-150PS P0973BP Redundant Power Supply
  • ENTERASYS A4H124-24FX P0973JN SecureStack A4 Fiber Switch
  • ENTERASYS A4H124-24TX SecureStack A4 Ethernet Switch
  • ENTERASYS A2H124-24FX SecureStack A2 Fiber Switch
  • ENTERASYS A2H254-16 SecureStack A2 Managed Switch
  • ENTERASYS A4H254-8F8T SecureStack A4 Managed Switch
  • Enterasys C2RPS-CHAS2 Redundant Power System Chassis
  • Enterasys A2H124-24 Managed Ethernet Switch
  • EPRO PR6423/003-030-CN Hazardous Area Sensor
  • EPRO PR6424/012-000 Eddy Current Displacement Probe
  • EPRO PR6424/013-130 + CON021 Eddy Current Sensor System
  • EPRO PR6424/014-040 11mm Eddy Current Probe
  • EPRO PR6423/001-000 Eddy Current Sensor Probe
  • EPRO PR6423/010-000-CN Eddy Current Probe
  • EPRO MMS6823 9100-00001-05 Output Module
  • EPRO CON011 9200-00001N Signal Converter
  • EPRO MMS6120 Dual Channel Speed Monitor 9100-00002-10
  • EPRO MMS6120 Dual Channel Overspeed Protection Monitor 9100-00002C-08
  • EPRO PR6423 and PR6424 Eddy Current Displacement Probes
  • EPRO PR9268/300-000 Seismic Velocity Sensor
  • EPRO MMS3120/022-000 Dual Channel Vibration Monitor 9100-03047-01
  • EPRO MMS6823R 9100-00001-06 Dual Channel Module
  • EPRO PR6423/10R-030-CN Displacement Sensor
  • EPRO PR6423 Eddy Current Displacement Sensor
  • EPRO PR6423/002-030-CN+CON021 Eddy Current Sensor
  • EPRO PR9376/20 Contactless Speed Sensor
  • EPRO PR6423/002-001-CN Eddy Current Probe
  • EPRO RSM020 Relay Output Module
  • EPRO SDM010 Signal Distribution Module
  • EPRO PR6423/010-010-CN Eddy Current Sensor
  • FANUC A81L-0001-0165 Servo Motor Cable
  • FANUC A05B-2452-C900 Teach Pendant Cable
  • FANUC A90L-0001-0422#50 Cooling Fan 9WF0624H7D05
  • FANUC A860-0326-T103 Alpha iA64 Pulse Coder
  • FANUC A860-0315-T101 Alpha i Pulse Coder
  • FANUC A860-0302-T001 Alpha Series Pulse Coder
  • FANUC A230-0604-X003 Operator Panel
  • FANUC A20B-8200-0927 I/O Link Module
  • FANUC A20B-2902-0290/08C Communication PCB
  • FANUC A20B-2901-0763/02A I/O PCB Module
  • FANUC A20B-2901-066 Main PCB Board
  • FANUC A20B-2002-0040/07DR Servo Control PCB
  • FANUC A16B-2203-0073/02A Power Supply PCB
  • FANUC A06B-6114-H106 Alpha i Servo Amplifier
  • FANUC A06B-6089-H104 Alpha Servo Amplifier SVM1-80
  • FANUC A06B-6079-H208 Alpha Servo Amplifier Module
  • FANUC A06B-6079-H106 Servo Amplifier
  • FANUC A06B-6077-H106 Servo Amplifier
  • FANUC A06B-0116-B203#0100 Servo Motor
  • HIMA F3DIO20/802 Digital I/O Module 982200442
  • HIMA 80105 Power Supply Module 984080105
  • HIMA X-DO2401 Digital Output Module 985210203
  • HIMA X-DI3201 Digital Input Module 985210201
  • HIMA F-PWR02 Power Supply Module for F-Series
  • HIMA K1412B / H51q-HRS Safety Controller 996141261 / 997205233
  • HIMA K7214 Power Supply Module 996721402
  • HIMA TM202-A00-B00-C00-D00-E00-G00 Analog Termination
  • HIMA TM521 Digital Input Termination Module
  • HIMA TM591-B00-G00 Termination Module HIMax System
  • HIMA KFD2-STC4-Ex1 SMART Transmitter Power Supply
  • HIMA KFD2-VR4-Ex1.26 Voltage Repeater Isolated Barrier
  • HIMA SB3073-EX Intrinsically Safe Barrier Module
  • HIMA H6200A Terminal Module for Safety I/O
  • HIMA Z7130 Power Supply Distribution Module
  • HIMA F8652E 984865264 Central Module HIQuad H51q
  • HIMA F8627 984862702 Communication Module HIQuad System
  • HIMA H41q-HS High-Speed Safety Controller B4237-1 997104237
  • HIMA F8652X Central Processing Unit 984865265
  • HIMA H4135 Safety Logic Solver 992413502
  • HIMA H51q-H High-Integrity Safety Controller B5233-2 997235233
  • HIMA F6217 Safety Controller 984621702
  • HIMA F3330 984333002 Digital Output Module
  • HIMA F7553 984755302 Communication Module
  • HIMA F7131 Power Supply Module
  • HIMA X-DO1201 985210204 Digital Output Module
  • HIMA H51q-HRS B5233-2 Safety Controller Module
  • HIMA F3231 16-Channel Digital Input Module
  • HIMA K9203A (996920360) Safety Relay Module
  • HIMA H51q-HS B5233-1 Safety Control System
  • HIMA F7131 Power Supply Monitoring Module
  • HIMA F8620/11 Central Module for HIQuad Systems
  • HIMA X-FAN 18 03 Redundant Fan Module for Safety Systems
  • HITACHI LYD000A Digital Input Module 8-Channel
  • HITACHI PS6000 Heavy-Duty Power Supply 24VDC 10A