Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

How is sewage generally treated?

来源: | 作者:佚名 | 发布时间 :2023-11-22 | 314 次浏览: | Share:

The main pollutants of industrial wastewater (industrial wastewater is not called sewage) and domestic sewage include and are not limited to the following: 1, COD (chemical oxygen demand) and BOD (biological oxygen demand) : consumption of water oxygen leads to the death of water organisms. The former is determined by chemical oxidation, and the latter by dissolved oxygen in water consumed by microbial culture, generally measured by 5 days. 2, total nitrogen and ammonia nitrogen, total phosphorus: lead to water eutrophication, aquatic plants and algae growth, consumption of oxygen in the water. 3, Ph value: This all understand Ha. 4, SS (suspended matter) : resulting in turbidity and sediment content. 5, chroma: let the water change color. The above pollutant indicators are the most concerned by sewage treatment, but there will be different increases or focuses according to the treatment goals and different types of sewage. Sewage treatment is mainly the use of physical (filtration, precipitation), chemical (chemical reaction) and biological (biological eating) methods to eliminate pollutants in the water reaction. For the convenience of understanding, this article does not expand on professional terms.

A sewage treatment plant (hydrolytic acidification +SBR process) the relative composition of domestic sewage is fixed, and after determining the approximate scale and inlet water quality, it can be done with a certain routine, but according to the specific local conditions and investment requirements to adjust and optimize. However, strictly speaking, process calculation, digital modeling and experiments are still needed before the design and construction of biochemical wastewater. Industrial wastewater due to various sources (such as paper waste water, alcohol waste water, printing and dyeing wastewater), different production processes (for example, the same printing and dyeing enterprises, the production line built in the last century and the production line built now are completely different) and the local environment, management level and other factors, Basically, the sewage of a factory (even if it is two factories that produce the same product, as long as the location is different) is a new technology development and construction, so there is no fixed model, and it can only be determined by digital modeling, small experiments, medium-sized experiments, etc. Industrial wastewater is not much to say, interested friends can look at the "outdoor drainage manual" industrial sewage volume, which has a general description.

First, the conventional domestic sewage treatment process is introduced to you: the domestic sewage generated by human life is collected through the pipe network to the underground septic tank near the building, where the initial precipitation and digestion are carried out. Fecal matter, toilet paper, and the like settle to the bottom of the septic tank due to its own density, while being decomposed (that is, eaten) into small particles and water-soluble substances by aerobic, anaerobic and aerobic bacteria (which can survive with or without oxygen). Therefore, the septic tank needs to clear the sediment for a period of time (generally half a year to a year), even if it is a high-end residential septic tank (when the taste of that...). .

Sewage treatment plant process schematic diagram Domestic sewage first through the grid, generally thick and thin two. The coarse grille has a gap of 10-30 mm, and the fine grille has a gap of about 3 mm. The floating and suspended materials in the sewage are intercepted when passing through here, and are transported to the slag deposit point by the screw conveyor or belt conveyor, and then transported to the landfill for landfill. After the coarse grid filtration (some in front of the coarse grid after the fine grid) of the sewage in order to reduce the complexity of the subsequent system and energy saving, generally through the pumping station to the highest point of the sewage plant, and then rely on gravity flow through the subsequent treatment facilities.

Fine grid and swirl sand sink (sewage is raised after the coarse grid, here is the highest point of the sewage plant) If the city has industrial wastewater mixed with the municipal pipe network (domestic general more or less mixed), the domestic sewage treatment plant needs hydrolysis acidification pool for further decomposition treatment. This kind of pool is mainly to form an anaerobic environment, so that anaerobic bacteria break the macromolecular chain in the sewage, eat some of it, and at the same time, make the sediment and other inorganic substances in the sewage precipitate part. Generally there will be hydrogen sulfide, methane and other gases produced here, and the taste is very bad.

The structure of the biochemical section of the SBR process is very large, and the general total volume is similar to the daily treatment scale of the treatment plant. For example, the treatment scale of a domestic sewage treatment plant is 100,000 tons/day, then the biochemical section of the plant will probably have a volume of about 80,000 cubic meters. Here, domestic sewage is biochemical through the action of microorganisms (anaerobic, facultative and aerobic bacteria) in the pool. The sewage is partially circulated inside and outside the structure using a pumping system. The blower blows oxygen from the outside to oxygenate the pool. The organic matter in the sewage is eaten by the bacteria in the pool, and the ammonia nitrogen and phosphorus in the sewage are converted into nitrogen and phosphate. If the structure is running properly, the water surface is a light reddish-brown, and you can smell the earthy fragrance after a thunderstorm. The following are several forms of biochemical ponds. After passing through the biochemical stage, the sewage is basically treated clean at this time. After the biochemical reaction, the sewage enters the sedimentation tank (generally called the secondary sedimentation tank), and through the action of gravity, the particles, bacteria and bacterial bodies in the water (those who die of old age, actually see the flocculent colloid) precipitate into sludge, which is dehydrated and transported to the landfill for landfill. The supernatant of the sedimentation tank spills through the overturning weir. After entering the disinfection equipment (generally for ultraviolet irradiation), it meets the external discharge standard, that is, the domestic sewage Level 1 B discharge standard.

  • Alstom vajh13yf1001aba - Automatic Trip Relay 220-250 V
  • ALSTOM Servo Inverter Type:ALSPA MV 1007-IT - - 3.0 kW
  • ALSTOM Cegelec Interface Modnet 1 / MB+ Fbk Mbp S1/S - Interface Module
  • Alstom Input / Output Card I/O Module SA44647.A - Module
  • Alstom Plug-in card Input/Output module SA44650.C - Module
  • ALSTOM Adjustment Module Keypad Alspa MV1000 - Keypad
  • Alstom Operating module Keypad Alspa MV1000 - Keypad
  • Alstom Plug-In Input/Output Module Sa 45629.B - Module
  • ALSTOM Adjustment Module Keyboard Alspa MV1000 - Keyboard
  • ALSTOM Control Set - 15 V 029.069642/26472/1011 - Voltage regulator
  • Alstom Input/Output Card Module SA44650.C - Module
  • Alstom Input / Output Card I/O Module - Module
  • Alsthom Alstom Plug-In Input/Output Module SA41630 B - Module
  • ALSTOM Servo Inverter Type: ALSPA MV 1007-IT - - 3.0 kW
  • Alstom Plug-In Input/Output I/O Module SA44647.A - Module
  • Alstom Plug-In Input/Output Module Sa 45629.B - Module
  • Alstom Plug-in card Input/Output module SA46623.B - Module
  • ALSTOM Control Module Keyboard Alspa MV1000 - Keyboard
  • Alstom Plug-In Input/Output Module SA46623.B - Module
  • Alstom Plug-In Input/Output Module SA44650.C - Module
  • Alstom Plug-In Input/Output Module SA43610.E - Module
  • Alstom Insertion Card Input / Output Module SA43610.E - Module
  • Alsthom Alstom Plug-In Input/Output Module SA41630 B - Module
  • Alstom Plug-In Input/Output I/O Module - Module
  • Alstom Plug-In Input/Output Module SA46623.B - Module
  • Alstom Plug-in card Input/Output I/O module SA44647.A - Module
  • Alstom Plug-in card Input/Output I/O module SA44647.A - Module
  • Alstom Plug-in card Input/Output module SA 45629.B - Module
  • ALSTOM Alspa VF Inverter Type : VF 4004b - - 1.5 Kw
  • Alstom Plug-In Input/Output Module SA46617.B - Module
  • Alstom PS 431 - Control Unit
  • Alstom Plug-In Input/Output Module Sa 46624.A - Module
  • Alstom Plug-In Input/Output Module SA44650.C - Module
  • Alstom Plug-In Input/Output Module SA43610.E - Module
  • ALSTOM Alspa MV1000 Frequency Type : Alspa MV1032 - - 15 Kw
  • Alstom Input/Output Card Module SA46617.B - Module
  • Alstom Input/Output Card Module Sa 45629.B - Module
  • Alstom Input/Output Card Module SA46623.B - Module
  • ALSTOM Servo-Converter Type : ALSPA MV 1007-IT - - 3.0 Kw
  • ALSTOM Frequency Type : ALSPA MD2000 - 43-400 (49-460)
  • ALSTOM Servo-Converter Type : ALSPA MV 1007 - - 3.0kW
  • Alstom PS 431 - Control
  • ALSTOM Alspa Cegelec Guide Value Transmitter 029.087.176/98N115099109 - Transmitter
  • Alstom Input/Output Card Module Sa 46624.A - Module
  • ALSTOM Control Set - 15 V 029.069642/26472/1011 - Voltage regulator
  • ALSTOM Alspa Module Control Set 029.111.890/27347/1018 - Module
  • ALSTOM Alspa Module Control Set 029.063.255/25443/1044 - Module
  • ALSTOM Alspa Cegelec Module Control Set 029.063.292/25943/1008 - Module
  • ALSTOM Microverter D 4-8/500/029.130.005 - Inverter
  • Alstom ISTAT M233 M233X2GUYECAL0A - Measurement unit M233X2GUYECAL0A NEW
  • ALSTOM Alspa Cegelec Guide Value Transmitter 029.087.176/98N115099109 - Transmitter
  • Alstom Input/Output Module SA 46624.A - Plug-in card
  • ALSTOM Cegelec Interface Modnet 1 / MB + Fbk - Mbp S1/S
  • ALSTOM MAE 00-11 - 8 Channel isolated analog i/o termination panel LC11-13 24118b
  • Alstom MMLG01 137945N - Test block electric panel 715209M T&D protection and control
  • ALSTOM Mae 00-11 - Channel Isolated Analog I/O Terminal Panel LC11-13 24118b Al
  • CONVERTEAM S20X4262/50 / S20X426250 - Module
  • CONVERTEAM MV530A4C1A / MV530A4C1A - Inverter
  • CONVERTEAM C100/5302 / C1005302 - Module
  • CONVERTEAM 20X4355B1L / 20X4355B1L - (new without box)
  • CONVERTEAM GM0020002 / GM0020002 - Module
  • CONVERTEAM P111-6052 / P1116052 - Module
  • Alstom PS 431 - Controller
  • ALSTOM Type : Alspa BC 32 - Brake Chopper Unit
  • ALSTOM Alspa MV500 SE23400075/MV502A4C1A - - 0.75kW Inverter
  • Alstom M30-Tx200 DIN931 - Hexagon screw stamped 8A B screw GE Alstom SW 46
  • Alstom Sa 46624.A - Plug-In Input/Output Module
  • ALSTOM Adjustment Module Keyboard Alspa MV1000 - Keyboard
  • Alstom PA20397/2186-03-H01 - Circuit Board
  • Alstom KBCH12001H12MEL 228633J - Relay Differential KBCH120
  • Alstom MMLG01 137945N - TestBlock Electric Panel 715209M T&D Protection & Control
  • Alstom KBCH12001H12MEL 228633J - Differential Relay KBCH120
  • Alstom MMLG01 137945N - Test Block Electrical Panel 715209M T&d Protection &
  • ALSTOM Mae 00-11 - 8 Channel Isolated Analog I/O Terminal Panel LC11-13 24118b
  • Alstom KBCH12001H12MEL 228633J - Differential Relay KBCH120 and extended warranty
  • Alstom MMLG01 137945N - Test Block Electrical Panel 715209M T & D Protection & De
  • Alstom DFI-110-0340F - DFI1100340F Diagnostic Flame Indicator
  • KCGG142 KCGG14201D20EEA - 287362J
  • ALSTOM MAE 00-11 - Channel isolated analog i/o termination panel LC11-13 24118b Al
  • KCGG122 KCGG12201DEED - 463055L and extended warranty
  • Alstom MMLG01 137945N - Test Block Electrical Panel T&D Protection & Control
  • Alstom 3FAFA5100A - Voltage Sensor TN7 112 003 Alstom T&D Protection & Control
  • Used ALSTOM PIB100 F 3BEB0169 - Board
  • Alstom Keypad - Alspa MV 1000
  • Alstom MMLG01 137945N - Test Block Electrical Panel 715209M T & D Protection &
  • ALSTOM PS441 - Overcurrent protection - Used
  • Alstom Power 2506305 - Circuit Board
  • ALSTOM PS431 - CONTROL UNIT
  • ALSTOM MV502S2B1A - 1 pc X Frequency Drive Alspa MV500
  • Alstom 3VAFS5500A - Voltage Sensor TN7105 002 Alstom T&D Protection & Control
  • ALSTOM MV507A2D1A - 1 pc X Frequency Drive Alspa MV500
  • KCGG KCGG12201L20EED - 655002M and extended warranty
  • ALSTOM TRVP059753000 - AGC3X-007 BLOCK ENCODER TRVP05975400
  • KCGG KCGG14202l20EEB - 654833M and extended warranty
  • Alstom 029 204 538 - cegelec Interface RS422/RS232 Alspa MV 1000
  • ALSTOM PIB100 F - 3BEB0169 Board
  • CONVERTEAM 8321-4002 / 83214002 - (new with box)
  • CONVERTEAM MVAJ14D1GA0774A / MVAJ14D1GA0774A - Relay
  • CONVERTEAM 8178-4002 / 81784002 - (new with box)
  • CONVERTEAM QTWIE2-VD4A / QTWIE2VD4A - (new with box)
  • CONVERTEAM A48DI-40DX-B7/95 / A48DI40DXB795 - Meter
  • CONVERTEAM V96LC/0-400RPM / V96LC0400RPM - Meter
  • CONVERTEAM A72DI-5-40X4/95 / A72DI540X495 - Meter
  • CONVERTEAM 8321-4002 / 83214002 - Module
  • CONVERTEAM 029.081-942 / 029081942 - Module
  • CONVERTEAM V96LC/0-600RPM / V96LC0600RPM - Meter
  • CONVERTEAM 20X4524B1L / 20X4524B1L - Module
  • CONVERTEAM EGS3C-ST11001 / EGS3CST11001 - Module
  • CONVERTEAM S8503-4001 / S85034001 - Module
  • CONVERTEAM MVAX12B1DA0752A / MVAX12B1DA0752A - Relay
  • CONVERTEAM 11P408ND8268/7 / 11P408ND82687 - (new without box)
  • CONVERTEAM MVAJ26L1BB0502A / MVAJ26L1BB0502A - Relay
  • CONVERTEAM C100/5120 / C1005120 - Module
  • CONVERTEAM D-984-0578 / D9840578 - Board
  • CONVERTEAM GDS1017-4001 / GDS10174001 - Enhancement Card
  • CONVERTEAM MBC101F1AD0761A / MBC101F1AD0761A - Module
  • CONVERTEAM GDS1006-4001 / GDS10064001 - Keypad
  • CONVERTEAM 25X8521/10 / 25X852110 - Module
  • CONVERTEAM VSELC1011A1AB / VSELC1011A1AB - (new without box)
  • CONVERTEAM RTS-13060102-R / RTS13060102R - Relay
  • CONVERTEAM LGPG-11101P55LEF / LGPG11101P55LEF - Relay
  • CONVERTEAM 203-399 / 203399 - Module
  • CONVERTEAM MV516A4C1 / MV516A4C1 - Inverter
  • CONVERTEAM SW867577-007 / SW867577007 - Module
  • CONVERTEAM MCGG22D1CD0503D / MCGG22D1CD0503D - Relay
  • CONVERTEAM MV506A4C1A / MV506A4C1A - Inverter
  • CONVERTEAM GM0025002 / GM0025002 - Module
  • CONVERTEAM MBCI01F1AD0511A / MBCI01F1AD0511A - Module