ABB ACS800 inverter IGBT module

F: | Au:FAN | DA:2025-05-21 | 1406 Br: | 🔊 点击朗读正文 ❚❚ | Share:



ABB ACS800 inverter IGBT module

Safety Notice

Applicable products: Suitable for ACS800-01/U1 and ACS800-02/U2 products.

Warning and Caution

Warning: Remind of situations that may cause serious injury or death and/or damage to equipment, such as dangerous voltage, electrostatic discharge, etc.

Attention: Remind users of special situations or events, or introduce relevant information on the topic, such as dangerous high voltage at motor cable terminals.

Installation and maintenance work

Only qualified electrical engineers are allowed to install and maintain transmission units.

It is prohibited to install or repair transmission units, motor cables or motors with electricity. After cutting off the input power, wait for at least 5 minutes until the intermediate circuit capacitor is discharged, and use a multimeter to measure and confirm the discharge before operation.

Do not operate control cables when the transmission unit or external control circuit is energized.

All insulation tests must be conducted with the cable disconnected, and ensure the correct phase sequence when reconnecting the cable.

grounding

Proper grounding is necessary to ensure the safety of personnel, reduce electromagnetic radiation and interference. The cross-sectional area of the grounding wire must meet safety regulations, and multiple equipment grounding terminals cannot be connected in series.

In scenarios that comply with European CE standards, cable entrances should maintain a 360 degree high-frequency grounding, and the cable shielding layer should be connected to the protective grounding wire (PE).

Do not install frequency converters with EMC filters in floating or high ground resistance power systems.


Mechanical Installation

The transmission unit is heavy and should not be carried by a single person. When carrying, do not let the front panel bear the weight and rely on lifting the back for transportation.

Ensure that drilling debris does not enter the transmission unit during installation, ensure sufficient cooling space, and do not fix the transmission unit by riveting or welding.

operate

Before debugging the transmission unit, ensure that the motor and driven equipment are suitable for operation within the speed range provided by the transmission unit.

Do not activate the automatic fault reset function of standard applications in situations where danger may occur.

Do not use the main power circuit breaker to control the start and stop of the motor. Instead, use control commands from the control panel keys or transmission unit I/O board.

Permanent magnet motor

When ACS800 is used to drive permanent magnet motors, only scalar control mode can be used.

When the permanent magnet motor is running, do not operate the transmission unit, as its operation transfers electrical energy back to the intermediate circuit. Even if the inverter is not working, the power supply will still charge the transmission system.

During installation and maintenance, use a fuse switch to disconnect the motor from the transmission unit. If possible, lock the motor shaft, connect the motor connection terminals together, and ground them.

Do not operate the permanent magnet motor at speeds higher than the rated speed to avoid overvoltage and capacitor bank rupture.


Product Overview

ACS800-01/U1: A wall mounted transmission unit used to control low-voltage AC asynchronous motors, with different external specifications (R2~R6), protection levels including IP21 (NEMA1) and IP55 (NEMA4, indoor only), etc. The control panel is CDP312R, including printed circuit boards such as main circuit board (RINT), motor control and I/O control board (RMIO), etc. The motor control mode can choose direct torque control (DTC) or scalar control.

ACS800-02/U2: There is relatively little mention in the document, and the external specifications are R7 and R8. Other information can refer to the relevant content of ACS800-01/U1. Some chapters of the two are common, such as safety instructions, electrical installation design, and braking resistors.


Installation

Mechanical Installation

Unpacking and inspection: After unpacking, check for any damage to the appearance, verify if the nameplate of the frequency converter matches the order, and check if the optional modules and equipment are complete.

Preparation before installation: Install vertically, place the radiator against the wall, check if the walls and floors of the installation site meet the requirements, ensure that there is enough space around the transmission unit for cooling air circulation, facilitate maintenance and repair, and pay attention to the space requirements when placing equipment of different protection levels up and down.

Installation method: including wall mounted installation and cabinet installation. Wall mounted installation requires marking the installation hole position with a punching template, fixing screws or bolts, installing the transmission unit and tightening it; Attention should be paid to the horizontal installation distance between the frequency converters when installing inside the cabinet, to prevent the recirculation of cooling air, and to set up air baffles.


Electrical installation design

Motor compatibility check: Ensure that the rated voltage and current of the motor meet the requirements, and avoid the rated voltage of the motor being less than 1/2 of the rated input voltage of the transmission unit or the rated current being less than 1/6 of the rated output current of the transmission unit.

Protecting motor windings and bearings: The output pulse voltage of the transmission unit may affect the motor insulation and bearings. ABB du/dt filters, common mode filters, etc. can be used to reduce the impact. Suitable filters and insulated bearings should be selected according to the motor type and power.

Power supply system connection: A manually operated circuit breaker can be installed between the AC power supply and the transmission unit, which must comply with relevant standards, such as using category AC-23B, etc; The input cable needs to be equipped with a fuse group, and the fuse model should be selected according to local safety regulations, input voltage, and rated current of the transmission unit.

Cable selection and wiring: The main power and motor cables need to be selected according to local regulations to meet the requirements of load current and temperature. The protection ground cables need to consider inductance and impedance limitations; It is best to use shielded cables for control cables, with separate routing for analog and digital signals to avoid long-distance parallel routing. When crossing, the angle should be 90 degrees.

electrical installation

Insulation performance inspection: Check the insulation performance of the motor and motor cables, disconnect the transmission unit from the main power supply, use a 1kV insulation meter to measure the insulation resistance of each relative protective ground, and the resistance value should be greater than 1 megohm.

Power cable wiring: Determine the length of wire stripping according to the external specifications, ground the cable shielding layer, connect the main power cable and motor cable to the corresponding terminals, and fix the junction box cover and front cover.

Control cable wiring: Thread the control cable through the entrance hole and connect it to the relevant detachable terminals on the RMIO board, ensuring a secure connection, grounding the shielding layer, and fixing the control cable and front cover.


Maintenance

Maintenance Cycle

Capacitor update: once a year when stored.

Temperature inspection and cleaning of radiator: Depending on the dust content in the environment, it should be done every 6-12 months.

Cooling fan replacement: Replace every five years, and replace spare fans for IP55 units and some IP21 units every three years.

Maintain content

Cleaning of radiator: Remove the cooling fan, use clean and dry compressed air to blow the radiator from bottom to top, while using a vacuum cleaner to absorb dust at the air outlet, and then install the cooling fan.

Cooling fan inspection: Pay attention to the noise of the fan bearings and the temperature of the radiator. Replace them in a timely manner when signs of damage appear, and use ABB designated spare parts.

Capacitor inspection: Electrolytic capacitors are used in the intermediate circuit, with a service life of about 100000 hours. Damage is often accompanied by the main power fuse melting or fault tripping. If there is suspicion of damage, contact the ABB representative office and use designated spare parts.

LED indication: The LED lights on the RMIO board and control panel installation components can indicate faults and normal power status.


Technical data

IEC level: lists the rated capacity, external specifications, air flow rate, heat loss, and other data of different models of ACS800-01 under 50Hz and 60Hz grid power supply.

Capacity reduction

Temperature induced capacity reduction: When the ambient temperature is between+40 ° C and 50 ° C, for every 1 ° C increase, the rated output current decreases by 1%. The rated current Icont.max is not allowed to be applied in environments exceeding 40 ° C.

Capacity reduction caused by altitude: When the altitude is between 1000-4000m, the rated current decreases by 1% for every 100m increase. If it exceeds 2000m, consult the local ABB dealer or office.

Main power cable fuse: provides cable specifications, fuse models, parameters, etc. corresponding to different models of ACS800-01.

Cable entry hole: information such as terminal size, cable diameter, and tightening torque for different external specifications.

Size, weight, and noise: The size, weight, and noise data of each external specification under different protection levels.

Motor wiring: parameters such as voltage, frequency, current, power limit, and recommended maximum motor cable length.

Efficiency and cooling: The efficiency is approximately 98% of the rated power, and the cooling method is an internal fan with a flow direction from the bottom to the top.

Protection level and environmental conditions: Protection levels include IP21 and IP55, as well as operating conditions such as environmental temperature, relative humidity, and pollution level.

Materials and applicable standards: Information on materials such as transmission unit casing and packaging boxes, following international standards such as EN50178, EN60204-1, etc.


Braking resistor

Configuration and selection: Transmission units with external specifications of R2 and R3 include built-in brake choppers, R4 and larger brake choppers are optional (model+D150), and resistors are additional components; When selecting the transmission unit/chopper/resistor, it is necessary to calculate the braking power to ensure that the resistor resistance and heat loss capacity meet the requirements.

Installation and wiring: All resistors must be installed outside the transmission unit module, with flame-retardant materials nearby. They should be connected using cables of the same model as the input cables of the transmission unit, with a maximum allowable length of 10m. The shielding layer should be properly grounded.

Protection and debugging: It is recommended to configure the main circuit contactor for external specifications R2~R5, and whether R6, R7, and R8 are needed depends on the selection situation; A thermal switch should be installed inside the braking resistor and connected to the digital input port as an external fault interlock signal; Activate the brake chopper function during debugging, turn off the overvoltage control function, and check the resistance value setting.


Model Supplement

IGBT MODULE KIT FS450R12KE3/AGDR-61C S 64635875

IGBT MODULE KIT FS300R17KE3/AGDR-66C S 64717839

IGBT MODULE KIT FS300R12KE3/AGDR-62C S 64717812

IGBT MODULE KIT FS450R17KE3/AGDR-61C S 64783831

IGBT MODULE KIT FS225R12KE3/AGDR-71C S 68569303

IGBT MODULE KIT FS300R12KE3/AGDR-72C S 68569541

IGBT MODULE KIT FS450R12KE3/AGDR-71C S 68569354

IGBT MODULE KIT FS225R17KE3/AGDR-76C S 68569583

IGBT MODULE KIT FS300R17KE3/AGDR-76C S 68569362

IGBT MODULE KIT FS450R17KE3/AGDR-71C S 68569591

IGBT MODULE KIT FS450R17KE3/AGDR-72C S 68569427

IGBT MODULE KIT FS300R12KE3/AGDR-71C S 68569346

IGBT MODULE KIT FS450R17OE4/AGDR-71C S TIM FOIL SP 3AXD50000948185


  • Siemens SINUMERIK 840D SL NCU 720.3B with PLC 317-3 PN/DP
  • Siemens 6AV6618-7GD01-3AB0 HMI Panel
  • OMRON F150-C15E-3 Vision Mate Controller PLC Overview
  • Mitsubishi MELSEC A Series PLC System A63P A3ACPU A616AD A68RD3
  • M68-2000 2 Axis Motion Controller SCE SERVO CNC
  • OMRON FZ-S2M PLC Camera Vision System
  • VISOLUX SLVA-4K PLC Module from Elektronik GmbH
  • OMRON CJ1M-CPU23 V2.0 PLC CPU Unit
  • ABB AI86-16CHF PCB Card 5761751-9 B Specifications
  • Allen-Bradley 100-D140ZJ22L Contactor Overview
  • Merlin Gerin PB80 PLC Rack
  • WEIR WE203 Power Supply PLC
  • OMRON NX-TS3102 Temperature Input Unit
  • Siemens 6ES7146-6FF00-0AB0 I/O Module
  • Fanuc A16B-3300-0057 Circuit Board
  • OMRON CJ1W-IDP01 Input Module
  • Siemens 6FX2007-1AD13 Handheld Unit
  • Gems EM54 PLC Module PCB
  • Beckhoff CX2030-0121 Embedded PC CPU
  • OMRON NJ301-1100 Machine Automation Controller
  • Biesse Rover CNI PLC 2153 030 7146.30 Numerical Control Module
  • OMRON CJ1W DA08V Analog Output Module
  • OMRON CS1D ETN21D Ethernet Module
  • Allen Bradley 1768 L43 CompactLogix Controller
  • Schneider TWDLMDA40DTK Twido PLC Module
  • Mitsubishi NZ2EX2B 60AD4 Analog Input Module
  • OMRON NS8 TV00B V2 Touch Display Panel
  • Mitsubishi AY71 CMOS TTL Output Module
  • OMRON C500 CPU11 E Processor Module
  • OMRON CJ1W PTS51 Temperature Input Module
  • Siemens 6SL3100-1DE22-0AA1 600V DC Supply
  • OMRON CJ1M-CPU23 PLC CPU 9‑Pin Serial
  • Schlumberger IMT4N 24‑250VAC 48‑230VAC PLC Timer
  • OMRON CJ1M-CPU22 PLC CPU Unit V2.0
  • Allen‑Bradley 2711P-B7C6D2 Touch Screen PanelView
  • ADSP-2181KST-160 Analog Devices DSP IC Specs
  • Schneider LC1F400 400A Contactor Specifications
  • Yaskawa SGDH-10DE-OY 1kW 400V Servo Drive
  • Schneider TM262L10MESE8T M262 PLC 5ns Inst
  • Mitsubishi AA104VJ05 10.4in LCD Panel Specs
  • Allen Bradley 1761-L32BWA MicroLogix 1000 PLC
  • Siemens 6ES7431-7KF00-0AB0 Analog Input Module
  • Allen Bradley 1769-OB16 Output Module
  • Siemens 6ES7131-1BL12-0XB0 Input Module
  • Beckhoff EP7041-3002 EtherCAT Box Module
  • Siemens RK7243-2AA30-0XB0 Communication Module
  • Siemens 4AM5742-8DD40-0FA0 Transformer
  • Siemens 3TK2834-1BB40 Safety Relay
  • Brother BAS 311 Sewing Machine Circuit Board
  • Yaskawa SGDH-10DE-OY Servo Driver
  • OMRON C60H C6DR DE V1 Sysmac PLC
  • MITSUBISHI ELECTRIC A2ACPU21 S1 CPU Module
  • ABB BAILEY INNPM12 Network Process Module
  • HONEYWELL 620 0073C IPC PLC Module
  • Mitsubishi 15050 PR02B PLC Circuit Board
  • SIEMENS 6SY7000 0AC37 Drive Control Module
  • OMRON TJ2 ECT16 Traxial EtherCAT Controller
  • GE Fanuc IC698PSD300D Power Supply Module
  • Texas Instruments Series 505 16 Position Base
  • OMRON YASKAWA SGDH 10DE OY Servo Drive
  • Allen‑Bradley 440G-MT Safety Interlock Switch Specs
  • Rubycon PD27A 24V 8A Power Supply Module
  • SK-H1-GDB1-F11D PLC Gate Driver Board Kit
  • VIPA 441-4UA14 451-4UA14 PLC Module Rack
  • Mitsubishi FX5U-80MT ESS PLC Controller Specs
  • Mitsubishi Q64TCRTN Temperature PLC Module
  • GE 1C31170G Rev10 PLC Circuit Board Module
  • Schneider TWDLMDA40DTK PLC Controller Module
  • Omron FQM1-MMA22 Motion Control Module Specs
  • OMRON CJ1W-NCF71 Position Control Unit Specs
  • Schneider TSXETY4103 Ethernet Module
  • Mitsubishi Q12PHCPU Process CPU
  • Yaskawa 3G3HV-A4022-CE AC Drive
  • Cincinnati Milacron 3-533-0669G Temperature Control Board
  • Allen Bradley 20AC030A3AYNANC0 PowerFlex 70 Drive
  • Siemens 6ES7314-6BG03-0AB0 CPU 314C-2 DP
  • Carrier 17EX54007903 PLC Module
  • OMRON CS1W-V600C12 ID Controller Module
  • Honeywell 51402755-100 PCB Card
  • Heidenhain ECN 113 Rotary Encoder
  • OMRON B7AM-8B16 I/O Terminal Block
  • Fanuc A06B-6110-H026 Power Supply Module
  • Schneider TSXETG3021 Ethernet Gateway
  • OMRON CS1W-CLK21-V1 Controller Link Unit
  • NP1W6406T-Z704 PLC I/O Module
  • OMRON CJ1W-DA08C Analog Output Module
  • Yaskawa 3G3HV-A4022-CE AC Drive
  • OMRON NB7W-TW01B CP1L-EL20DR-D Power Panel
  • OMRON C500-NC103-E Position Control Unit
  • Steag Hamatech PLC DCS Servo Control System
  • Siemens 6SN1123-1AA00-0DA1 Power Supply Module
  • GE IC693CHS391H CPU & AD693CMM301A PLC Module
  • Siemens 6FC5303-0AF23-1AA1 PLC Control Panel
  • Square D CM4000T PowerLogic Circuit Monitor J1 F16
  • Siemens 6FX5002-5DG10-1BA0 MOTION-CONNECT 500 Cable
  • Schmersal SRB324ST 101195504 Safety Relay 24V
  • Mitsubishi 15050-PR02A PLC Circuit Board Module
  • OMRON CQM1-AD041 Analog Input PLC Module
  • Beckhoff EL5042 EtherCAT PLC Terminal Module
  • OMRON C200HW-MC402-E Motion Control Unit
  • C36TC0UA1100 Industrial Temperature Controller
  • NL8048BC24 12 Industrial Control LCD Module
  • OMRON R88D Servo Drive and Motor System
  • OMRON CS1W CLK21 V1 Controller Link Module
  • OMRON YASKAWA R7M A20030 S1 D Servo Motor
  • SIEMENS 6AV2128 3KB06 0AX1 Unified Comfort Panel
  • Schneider Electric METSEPM8240 PowerLogic Meter
  • Advanced AMCI 1PLC 1 31F Programmable Limit Switch
  • ABB PM582 ETH Programmable Logic Processor
  • SIEMENS 6FC5110 0CB01 0AA0 CPU Control Board
  • Schleicher P03GS13A CPU Module
  • Siemens 6SN1123-1AA00-0BA1 Power Module
  • Mitsubishi A1S61PN Power Supply Module
  • Yaskawa CPS-IONB DC Power Supply Module
  • Siemens 6ES7215-2BD00 CPU 215-2
  • Mitsubishi A2ACPU MELSEC PLC System Kit
  • ProSoft 3150-MCM Communication Module
  • Mitsubishi OSE104ET Incremental Encoder
  • OMRON CJ1W-AD081-V1 Analog Input Module
  • Broadcom BCM5464A1KRB Quad Port Ethernet IC
  • Modicon M221-24IO TM221C24 PLC 24 PNP Transistor
  • Allen-Bradley 1321-3R160-B Line Reactor 3R160B
  • Beckhoff CX1020-0012 Embedded PLC Module Specs
  • Turck BL20-PF-24VDC-D Power Feed Module Specs
  • Siemens 6SY7000-0AC37 Power Supply Module
  • Yaskawa SGDH-10DE-OY 1kW 400V Servo Drive Specs
  • Omron 3G3SV-BB015-E 1.5kW 220V VFD Specs
  • Uni-Pro CPU91-PLC J 23.020167X Processor Module