Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

Rockwell Automation Stratix series Ethernet devices

来源: | 作者:FAN | 发布时间 :2025-09-25 | 326 次浏览: | Share:

Rockwell Automation Stratix series Ethernet devices

Overview of Basic Information and Equipment Categories

Basic information

Document positioning: Technical specification manual for industrial grade Ethernet equipment, including detailed parameters, compatibility, installation requirements, suitable for equipment selection, deployment, and maintenance;

Applicable brands: Allen Bradley Stratix series, some including ArmorStratix (reinforced) sub series;

Core coverage categories: There are a total of 16 types of devices, divided into switch categories (10 types), routing/security categories (3 types), wireless categories (1 type), and auxiliary technology categories (2 types), as follows:

Switches: Stratix 2000 (unmanaged), 2100 (unmanaged), 2500 (light managed), 5200 (managed), 5400 (managed), 5410 (managed), 5700 (managed), ArmorStratix 5700 (reinforced managed), 5800 (modular managed), 6000 (managed);

Routing/Security Category: Stratix 4300 (Remote Access Router), 5900 (Service Router), 5950 (Security Gateway);

Wireless category: Stratix 5100 (wireless access point/workgroup bridge);

Assistive technology: Embedded switching technology (Ethernet Taps), configurable NAT routers, CIP security agents.

Core equipment technical specifications (sorted by category)

(1) Switch category: classified by "non network management/light network management/network management"

1. Non managed switch: Stratix 2000/2100

Core features: No complex configuration function, plug and play, focusing on basic data transmission;

Key parameter comparison:

Equipment model, port specifications (typical), power supply range, operating temperature, protection level

Stratix 2000 (Series B) 5-18 ports (FE/GE RJ45+SFP, partially pre installed multi-mode/single-mode SFP) 12-48V DC, 18-30V AC -10~60 ℃ (base version)/-40~75 ℃ (wide temperature version) IP30

Stratix 2100 5-18 ports (FE/GE RJ45+SFP, including PoE) 12-48V DC, 24V AC -40~75 ℃ IP30

Special design: Stratix 2000 Series A/B, optimized port configuration for Series B (such as replacing 1783-US14T2S/A with 1783-US16T2S/B and adding 2 GE SFP slots).

2. Light network management switch: Stratix 2500

Core function: Supports basic VLAN and IGMP snooping, without complex routing functionality;

Key parameters: Only 2 models (1783-LMS5/8), 5-8 FE copper cables, power supply 12-24V DC, working temperature -20~60 ℃, protection IP30, simple networking suitable for industrial control scenarios.

3. Network management switch: 5200/5400/5410/5700/ArmorStratix 5700/5800/6000

Common features: Supports Layer 2/Layer 3 protocol, CIP Sync (IEEE 1588), DLR ring network NAT, Partial includes PoE/PoE+(30W/port);

Differentiated parameters (typical models):

Model Port Capability Power Supply and PoE Budget Wide Temperature Capability Special Advantages

5200 (1783-CMS10DN) 8GE+2GE combo 12-48V DC, no PoE -40~60 ℃ support PRP redundancy, TSN ready

5410 (1783-IMS28GNDC) 12GE+4GE SFP+12PoE 24-60V DC, single power 60W/dual power 185W -40~60 ℃ with conformal coating, suitable for harsh environments

ArmorStratix 5700 (1783-ZMS8TA) 8FE, M12 interface 9.6-60V DC, no PoE -40~60 ℃ IP66/IP67 protection, reinforced shell for impact resistance

5800 (1783-MMS10EAR) 8GE+2GE SFP (modular, expandable 16 ports) 12-54V DC, PoE total budget 360W -40~60 ℃ supports hot swappable expansion modules, suitable for large-scale networking

6000 (1783-EMS08T) 8FE+1SFP 24V DC, no PoE 0~60 ℃, compact size, compatible with substations (IEC 61850-3 compatible)

(2) Routing/security devices

1. Stratix 4300 Remote Access Router

Core capability: Supports both wired (LAN/WAN) and wireless (Wi Fi 802.11a/b/g/n/ac, 4G LTE CAT4) dual-mode, with a maximum data rate of 1.73 Gbps (Wi Fi) and 150 Mbps (4G download);

Key parameters: Power supply 9-34V DC, operating temperature -20~65 ℃ (non wireless version)/-20~60 ℃ (wireless version), including Bluetooth 5.1, compatible with remote industrial site networking.

2. Stratix 5900 Service Router

Positioning: Small industrial service routing, supporting VPN and firewall;

Parameters: Power supply 5V DC (requires external adapter), operating temperature -25~60 ℃, protection IP30, suitable for lightweight remote management scenarios.

3. Stratix 5950 Security Gateway

Core functions: CIP Security encryption, port isolation, support for 100/1000Base-T/SFP;

Parameters: Power supply 12-48V DC, working temperature -40~60 ℃, including alarm relay (30V DC/1A), suitable for industrial network security isolation requirements.

(3) Wireless device: Stratix 5100 wireless access point

Coverage scenario: Industrial wireless networking, supporting access point/bridge mode;

Key parameters: dual frequency (2.4GHz/5GHz), external antenna, power supply 48V DC (PoE), operating temperature -20~55 ℃, protection IP30, regional models (US/Canada/EU/China, etc., suitable for local frequency bands).

(4) Assistive technology category

Embedded Switching Technology (Ethernet Taps): including copper/fiber optic cables (1783-ETAP/ETAP1F), supporting 100Base-T/FX, operating temperature -25~70 ℃, used for network traffic monitoring;

Configurable NAT router (1783-NATR): 2-port Ethernet, powered by 20.4-27.6V DC, operating temperature -25~70 ℃, compatible with small network address translation;

CIP Security Proxy (1783-CSP): Supports CIP protocol encryption (integrity+confidentiality), with a maximum packet rate of 10000 pps (I/O) and a working temperature of -25~70 ℃, enhancing industrial control network security.

Common technical requirements and environmental adaptability

1. General parameters

Power supply commonality: Most support 12-48V DC (SELV level), some include AC power supply (100-240V AC);

Protection level: Conventional equipment IP20/IP30, reinforced version (ArmorStratix 5700) IP66/IP67;

Electromagnetic compatibility (EMC): compliant with IEC 61000-6-2/-4, resistant to ESD (contact 6kV/air 8kV), and resistant to radiated interference (10V/m, 80-2000MHz).

2. Environmental adaptability (industrial standard)

Temperature: Most models support -40~60 ℃ (wide temperature range), while some basic models support 0~60 ℃;

Humidity: 5%~95% non condensing;

Mechanical resistance: vibration 2g (10-500Hz), impact 15g (working)/30g (non working), in compliance with IEC 60068 series standards.


Supporting accessories and compatibility

1. Core attachments

SFP module: covering 100Base FX/LX (multimode 2km/single-mode 20km), 1000Base SX/LX (multimode 550m/single-mode 10km), 10GBase SR/LR (multimode 400m/single-mode 10km), partially supporting digital optical monitoring (DOM);

Cable: Industrial grade Ethernet jumpers (CAT5e/CAT6, RJ45/M12 interfaces, shielded/unshielded), cable reels (100-600m);

Storage media: Industrial SD card (1784-SD1/SDHC8), CompactFlash card (1783-MCF/RMFC), compatible with device configuration storage.

2. Compatibility rules

SFP compatibility: GE SFP is only compatible with GE slots (e.g. Stratix 2000 GE slots only support 1783-SFP1GSX/GLX);

Firmware requirements: Some modules require specific firmware versions (e.g. 1783-SFP100T requires Stratix 5400 firmware 3.001+);

Expansion module adaptation: Stratix 5800/8000 only supports expansion modules of the same series (such as 5800 adapted to 1783-MMX16T).

Certification

Core certification (common across the entire series)

Security certification: c-UL-us(UL 61010-1)、CE(EMC/RoHS)、ATEX(II 3 G Ex nA IIC T4 Gc)、IECEx( Same as ATEX level);

Industrial protocol certification: ODVA EtherNet/IP compliant, partially compliant with IEEE 1613 (substations) and IEC 61850-3 (power automation).


Key selection suggestions

Adverse environment (dust/humidity): ArmorStratix 5700 (IP67) or Stratix 5410 (conformal coating) is preferred;

PoE demand scenarios: Stratix 5410 (dual power 185W budget), 5800 (360W total budget), compatible with cameras and sensor power supply;

Remote networking: Stratix 4300 (4G+Wi Fi) is suitable for industrial sites without wired coverage;

Security isolation: Stratix 5950 (CIP Security) and 1783-CSP (Protocol Encryption) are adapted to control networks that require tamper proof measures.

  • WESTINGHOUSE 5X00070G01 Ovation Module
  • Westinghouse 5X00605G01 Control Module
  • WESTINGHOUSE 5X00241G02 Ovation System Communication Module
  • WESTINGHOUSE 5X00226G03 Ovation Module
  • Westinghouse ZX345Q Control System
  • WESTINGHOUSE ST24B3 Temperature Transmitter
  • WESTINGHOUSE AID-1 Industrial Keyboard
  • Westinghouse 5X00241G01 Control Module
  • WESTINGHOUSE 5X00226G02 Ovation Controller Base Module
  • WESTINGHOUSE 5X00119G01 Ovation Module
  • Westinghouse 5X00105G14 Control Module
  • WESTINGHOUSE 5X00105G01 Ovation System Base Module
  • WESTINGHOUSE 5X00058G01 Ovation Controller
  • Westinghouse 5A26391H24 Control Module
  • WESTINGHOUSE 4D33942G01 Ovation I/O Communication Module
  • WESTINGHOUSE 3A99158G01 Ovation I/O Module
  • WESTINGHOUSE 3A99200G01 Control Module
  • WESTINGHOUSE 3A99132G02 Ovation System Power Module
  • WESTINGHOUSE 3A99132G01 Ovation Interface Module
  • WESTINGHOUSE 1X00416H01 Control Module
  • WESTINGHOUSE 1X00024H01 Ovation System Interface Module
  • WESTINGHOUSE 1C31227G02 Ovation I/O Module
  • Westinghouse 1C31194G03 Control Module
  • WESTINGHOUSE 1C31194G02 Ovation Controller Module
  • WESTINGHOUSE 1C31194G01 Ovation Controller Module
  • WESTINGHOUSE 1C31189G01 Control I O Module
  • WESTINGHOUSE 1C31179G02 Ovation Processor Module
  • WESTINGHOUSE 1C31164G02 Ovation Relay Output Module
  • Westinghouse 1C31161G02 RTD Input Module
  • WESTINGHOUSE 1C31150G01 Ovation DCS I/O Controller Module
  • WESTINGHOUSE 1C31113G02 Ovation Analog Input Module
  • WESTINGHOUSE 1C31129G03 Control Module
  • WESTINGHOUSE 1C31122G01 Process Controller | Ovation DCS Control Module
  • WESTINGHOUSE 1C31113G02 Ovation Analog Input Module
  • WESTINGHOUSE 1B30023H02 Control Module
  • WESTINGHOUSE 1B30035H01 Turbine Control System Module
  • WIDAP UFW30.156 6K8J175W0823 Power Resistor Technical Profile
  • WINGREEN IPB PCB V2.0_A01 03ZSTL6-00-201-RS Industrial Power Board
  • WINGREEN CANopen_ADAPTER V5.0_A01 03ZSTI-00-501-RS Module
  • WINGREEN PUIM V2.0 034STM4-00-200-RS Power Interface Module
  • WINGREEN DUDT_DETECTION_V2.0_A01 03ZSTJ0-00-201-RS Detection Control Board
  • WINGREEN LAIB V3.0_A00 034STN1-00-300-RS Embedded Industrial Motherboard
  • WINGREEN FAN_DETECTION V1.0_A05 03ZSTJ3-00-105Fan Monitoring Module
  • WINGREEN LAIB V3.0_A00 034STN1-01-300-RS Interface Board
  • WINGREEN ATKB_V5.0_A01 03ZSTI4-00-501 Industrial Control Keyboard Module
  • WINGREEN ATKB_V5.0_A01 03ZSTI4-01-501 Industrial Motherboard | Embedded Control Board
  • WINGREEN FPB_V3.0_A01 03ZSTJ1-00-301-RS Fieldbus Processor
  • WINGREEN DSPB_V4.0_A02 03ZSTI7-00-402-RS Digital Processing Board
  • WOHNER 31110 Cylindrical Fuse Holder
  • WOODHEAD APPLICOM PCI4000 PCI Communication Card Industrial DeviceNet CAN Bus Interface
  • Woodward 8440-1706 Industrial Control System Module
  • Woodward 8440-2052 H Synchronizer Load Share Module
  • Baldor KPD-TS12C-30E 12.1" Color TFT Touch Screen Ethernet HMI
  • Baldor KPD-TS10C-30E 10" Color TFT Touch Screen Operator Interface with Serial and Ethernet Interfaces
  • Baldor KPD-TS05C-30E 5.6" Color TFT Touch Screen with Serial and Ethernet Interface
  • Baldor KPD-TS05C-30 5.6 Inch Color TFT Touch Screen Serial Interface
  • Baldor KPD-TS05M-10 5.6" Monochrome Touch Screen Serial Interface HMI
  • Baldor KPD-TS03M-10 Monochrome Touch Screen Operator Interface
  • Baldor KPD-KG420-30 4x20 Graphic Display with 12 Function Keys - Serial Interface
  • Baldor KPD-KG420-20 4x20 Character Graphic Display Serial Interface
  • WOODWARD EASYGEN-3200-5 8440-1992 A Genset Controller
  • WOODWARD PEAK200-HVAC 8200-1501 C Version | Industrial Building Automation Controller
  • Woodward 8440-2052 easyGEN-3200 Genset Control Power Management
  • Woodward 8237-1246 + 5437-1119 Control System Module
  • WOODWARD SPM-D11 8440-1703 Overspeed Protection System Module
  • WOODWARD 8237-1369 Governor Control Module
  • Woodward 8237-1600 Digital Control Module
  • WOODWARD BUM60-1224-54-B-001-VC-A0-0093-0013-G003-0000 3522-1004 Industrial Control Module
  • WOODWARD 8200-1302 Genset Controller
  • Woodward 8901-457 Speed Control Module
  • WOODWARD 5501-465 Control Module
  • Woodward 5448-890 SPM-D10 Digital Control Module
  • WOODWARD 5437-1067A Turbine Governor Actuator
  • Woodward 8440-1666 B Digital Control Module
  • WOODWARD 8440-1706 A SPM-D11 Synchronous Phase Modulator Module
  • WOODWARD 5466-425 Programmable Automation Controller (PAC)
  • WOODWARD 5466-318- Industrial Gas Turbine Control Module
  • WOODWARD 5453-277 Digital Control Module
  • WOODWARD 5453-203 Digital Governor Control Module
  • WOODWARD 9907-1106 Pressure Converter
  • WOODWARD 5233-2089 Professional Industrial Control System Module
  • WOODWARD 9907-147 Power outage tripping overspeed protection system
  • WOODWARD 8237-1600 Digital Speed Control System
  • WOODWARD 8402-319 8402-119 microprocessor speed controller
  • Woodward 8237-1006 Digital Governor
  • WOODWARD 5501-471 Communication Module
  • WOODWARD 5466-258 Input/Output Module
  • WOODWARD 5501-467 Multi Protocol Communication Gateway and I/O Expansion Module
  • WOODWARD 5501-470 Digital microprocessor controller module
  • WOODWARD 9907-1200 Digital Governor
  • WOODWARD 8444-1067 High Performance Digital Microprocessor Controller Module
  • WOODWARD 8446-1019 Integrated Gas Engine Electronic Control System
  • WOODWARD 9907-162 Digital Engine Governor
  • WOODWARD 5466-316 Simulation Combination Module
  • WOODWARD 5464-414 Digital Speaker Sensor Module
  • XANTREX XFR40-70 DC power supply
  • XP POWER F8B6A4A6A6 power module
  • XP POWER F8B6D4A3G3 power supply
  • XYCOM XVME-674 VMEbus Single Slot CPU/Processor Module
  • XYCOM XVME-957 Circuit Board
  • XYCOM XVME-976 PC board computer
  • XYCOM XVME-530 8-Channel Isolated Analog Output Module
  • XYCOM Proto XVME-085 Bus Module
  • YAMAHA RCX40 4-AXIS ROBOT CONTROLLER
  • YAMATAKE EST0240Z05WBX00 touch screen display
  • YAMATAKE HD-CAOBS00 flowmeter
  • HIMA X-COM 01 Communication Module
  • HIMA HIMax X-AO 16 01 Analog Output Module
  • HIMA X-AI3251 Analog Input Module
  • HIMA X-DO3251 Digital Output Module
  • HIMA X-DI3202 Digital Input Module
  • HIMA X-DI6451 Digital Input Module
  • YASKAWA USAHEM-02-TE53 AC servo motor
  • Yaskawa JZNC-XPP02B Teaching Programmer
  • YASKAWA CACR-SR07BE12M servo drive
  • YASKAWA JAMSC-B2732V Advanced Drive Controller
  • YASKAWA JGSM-06 Controller
  • YASKAWA PCCF-H64MS 64MB Industrial Memory Module
  • YASKAWA CACR-02-TE1K servo driver
  • YASKAWA JAPMC-IQ2303 Controller Module
  • YASKAWA DDSCR-R84H Controller
  • YASKAWA JANCD-XTU01B circuit board
  • YASKAWA JANCD-XIO01 High Performance PC Input/Output (I/O) Board
  • YASKAWA JACP-317800 servo drive
  • XYCOM 120974 - Circuit Board
  • XYCOM 99298-200 - PC Control Card 99207A-001
  • XYCOM 99298-266 - CPU Board
  • XYCOM 99311-001 - Screen Display Ribbon Cable