  • Honeywell SPS5713 Power Supply
    ❤ Add to collection
  • Honeywell SPS5713 Power Supply

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    • ¥12673.00
      ¥13127.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:0.183KG
    • Quantity:
    • (Inventory: 6489)
Description

Honeywell SPS5713 (51199930-100) Power Supply Module

The Honeywell SPS5713 (model number 51199930-100) is a robust and efficient power supply module designed for use in Honeywell Series 8 I/O systems. It provides a regulated 24V DC output to power controllers, I/O modules, and field devices within distributed control systems (DCS) such as Experion PKS and Safety Manager. Engineered for high availability, the SPS5713 supports redundant configurations, comprehensive diagnostics, and hot-swap replacement, making it ideal for critical industrial processes where uninterrupted operation is essential.

Overview and Key Features

The SPS5713 converts incoming AC or DC power to a stable 24V DC supply for the backplane and connected modules. Its advanced design ensures efficiency and reliability in harsh environments. Key features include:

  • Wide input voltage range: 100–240 VAC (50/60 Hz) or 110–300 VDC for global compatibility

  • Regulated 24V DC output with high efficiency (> 90%) minimizing heat dissipation

  • Output power rating: 120 W continuous (5 A at 24V DC)

  • Redundancy support: 1+1 or N+1 parallel operation with automatic load sharing and OR-ing diodes

  • Comprehensive diagnostics: output voltage monitoring, overcurrent protection, overvoltage crowbar, and alarm relay contacts

  • Hot-swappable design allowing replacement without system shutdown in redundant configurations

  • LED indicators for input power, output OK, and fault status


Technical Specifications

Model: SPS5713 (51199930-100)

Input Voltage (AC): 100–240 VAC, 50/60 Hz (autoranging)

Input Voltage (DC): 110–300 VDC

Output Voltage: 24 VDC ±1%

Output Current: 5 A (120 W)

Ripple & Noise: < 50 mVpp

Hold-up Time: > 20 ms at nominal input

Protection: Overload (105–150%), overvoltage (30–32 V crowbar), short-circuit (hiccup mode)

Isolation: 3000 VAC input-to-output, 1500 VAC input-to-ground

Operating Temperature: -40°C to +70°C (derating above 60°C)

Humidity: 5% to 95% non-condensing

Dimensions: Standard single-width Series 8 module (approx. 50 mm wide)

Redundancy and High Availability

The SPS5713 is designed for applications demanding maximum uptime. It supports parallel operation with other identical modules for 1+1 or N+1 redundancy. In redundant configurations, modules automatically share the load current, and if one unit fails, the remaining units instantly assume the full load without interruption. The module includes an integrated OR-ing diode and alarm relay contacts that signal a fault to the control system. This architecture is essential for critical processes in oil and gas, power generation, and chemical industries.

Integration with Honeywell Systems

The SPS5713 mounts directly into Honeywell Series 8 I/O racks, providing power to the backplane and all installed modules. It is compatible with C300 controllers, Safety Manager, and various I/O modules. In larger systems, multiple power supplies can be installed in different slots to power separate sections or to provide redundancy. The module communicates its status via the backplane and front-panel LEDs, enabling easy monitoring from the control system or locally. It is fully compliant with Experion PKS and Safety Manager architectures.


Applications

This power supply module is deployed across a wide range of industries:

  • Oil and gas – offshore platforms, refineries, pipeline control centers

  • Chemical processing – continuous and batch processes requiring high reliability

  • Power generation – fossil, nuclear, and renewable plants

  • Pharmaceutical – sterile manufacturing environments

  • Water and wastewater – treatment plants and pumping stations

  • Manufacturing – assembly lines and material handling systems

It powers controllers, I/O racks, fieldbus couplers, and other 24V DC automation equipment, ensuring continuous operation of critical control and safety functions.


Installation and Maintenance

Installation is straightforward: the module slides into a dedicated slot in the Series 8 rack and is secured with integrated locking clips. Electrical connections are made via the rack backplane, so no field wiring is required. Front-panel LEDs provide immediate visual status: green for input power present, green for output OK, red for fault. In redundant setups, modules can be replaced while the system is running—simply unplug the faulty unit and insert a new one. The module's rugged construction meets ISA-S71.04 Class G3 for harsh environments, ensuring long-term reliability.

Certifications and Compliance

The Honeywell SPS5713 (51199930-100) carries essential certifications for global use:

  • CE – EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU

  • UL/cULus – UL 61010-1, UL 61010-2-201

  • FM – Class I Division 2 (optional)

  • TÜV Rheinland certified for functional safety (when used in Safety Manager systems)

  • RoHS, REACH compliant

  • Marine certifications (ABS, DNV-GL) available on request

These certifications ensure compliance with safety and environmental standards worldwide.



  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Bonfiglioli Active 401/201 Inverter Selection and Application Guide
  • Bonfiglioli EM-IO-04 Expansion Module Configuration Guide
  • Bonfiglioli EM-ENC-02 Expansion Module Engineering Configuration Guide
  • Bonfiglioli A-series gearbox selection and maintenance
  • Bonfiglioli Transmission and Automation Product Selection Reference
  • Bonfiglioli RAN series bevel gearbox selection and maintenance guide
  • Bonfiglioli ACTION 401/201 Inverter Engineering Integration Guide
  • Alcatel Lucent Stellar AP1301 Deployment and Performance Optimization
  • Alcatel Lucent ALE Wireless Handheld System Selection and Deployment Guide
  • In depth analysis of Alcatel Lucent MDR-8000 microwave system engineering technology
  • Alcatel 1660SM Multi Service Node Operations and Troubleshooting
  • Alcatel Lucent OmniSwitch 6850 Stacking and Security Configuration Guide
  • Alcatel Lucent 7750 SR Router High Availability Deployment and Troubleshooting
  • Alcatel 1600 Series SDH Equipment Operation and Maintenance Guide
  • Alcatel Lucent 9500 MPR Microwave Platform Deployment and Troubleshooting
  • Alcatel Lucent 7450 ESS High Availability Deployment and Operations Guide
  • Alcatel OmniPCX 4400 REFLEXES Phone Configuration Troubleshooting
  • Alcatel Lucent OmniSwitch 6850E Stacking Operations and Troubleshooting
  • Alcatel Lucent OmniSwitch 6450 Stacking and Troubleshooting Guide
  • Lucent Stinger DSLAM High Availability Deployment and Fault Recovery Complete Guide
  • Alcatel Lucent 1660SM Optical Transmission System Architecture and Business Bearer
  • ALCATEL-LUCENT 9500 MPR Microwave Packet Wireless System Performance
  • Atlas Copco MT Focus 6000 Controller Safety Specification and Electrical Grounding
  • Atlas Copco Power MACS 4000 Automated Tightening System Performance
  • Design and Protection of Constant Torque Application for Atlas Copco Neos Inverter
  • Atlas Copco Power Focus 8 Family Selection Configuration and Virtual Station Function Complete Explanation
  • Atlas Copco Power Focus 4000 Controller Safety Deployment and Electrical Grounding Specification
  • Atlas Copco Power Focus 3000 Controller Installation, Debugging, and Troubleshooting Guide
  • Atlas Copco Tensor S Tightening Tool Troubleshooting Guide
  • Application and maintenance of Atlas Copco SRTT-B torque sensor
  • Atlas Copco ACTA 4000 Torque Analyzer Operation and Calibration Guide
  • Atlas Copco Tensor STB Wireless Tightening Tool Deployment Guide
  • Atlas Copco Power Focus 4000 Configuration and Troubleshooting Manual
  • Atlas Copco Power Focus 6000 and Tensor STR System
  • Energy efficiency and selection of Atlas Copco ZR/ZT oil-free screw compressor
  • Atlas Copco PowerMACS 4000 Tightening Control System
  • Atlas Copco Elektronikon MK5 Controller Operation Guide
  • Atlas Copco Tensor ES and PF600 Tightening System
  • ADLINK STC2-AL/KL Industrial Control Tablet BIOS and Drivers
  • ADLINK STC-15W04 industrial tablet computer
  • ADLINK SP2-EHL Fanless Tablet Selection and Configuration Guide
  • ADLINK PXIS-2719A Chassis Deployment Monitoring Guide
  • ADLINK PXIe-9908 SMU Deployment and Configuration Guide
  • ADLINK PXIe-9852 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9848 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9834 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9529H Dynamic Signal Acquisition Configuration Guide
  • ADLINK PXIe-3988 Xeon Deployment Optimization Guide
  • ADLINK PXIe-3987/3977/3937 Deployment and Debugging
  • ADLINK PXIe-3987 Installation and Configuration Programming Guide
  • ADLINK-PXIe-3988-3987-3977-3937-TL Controller Deployment and Maintenance Guide
  • ADLINK PXI-2020/2022 Synchronous Acquisition Card Configuration and Synchronization Guide
  • ADLINK DAQ/PXI-2000 series synchronous acquisition card configuration and triggering
  • ADLINK PXES-2788 series chassis deployment and maintenance
  • ADLINK PXES-2785 18 Slot Gen3 Chassis Deployment and Maintenance Guide
  • ADLINK PXES-2780 18 Slot PXIe Chassis Deployment Configuration
  • ADLINK PXES-2596 Gen3 Chassis Installation and Maintenance Guide
  • ADLINK PXES-2590 Chassis Deployment and System Management
  • ADLINK PXES-2314T Chassis Deployment and Troubleshooting Guide
  • ADLINK PXES-2301 Chassis Installation Monitoring and Troubleshooting
  • ADLINK PCIe-U300 Series USB3 Vision Acquisition Card Deployment Guide
  • ADLINK PCIe PXIe-8565 Expansion Kit Remote Control and Compatibility
  • Installation and troubleshooting of ADLINK PCIe GIE74V four channel PoE acquisition card
  • ADLINK PCIe GIE7x Poe+Acquisition Card Configuration and Triggering Troubleshooting
  • Advanced triggering and multi card synchronization of ADLINK PCIe-CPL64V image acquisition card
  • ADLINK PCIe-CPL64 Image Acquisition Card Hardware Trigger and Encoder Application
  • Application and troubleshooting of ADLINK PCIe-8560/PXI-8565 expansion kit
  • ADLINK PCIe 8332/PCIe 8334/PCIe 8338 EtherCAT Motion Controller Multi axis Synchronous Control
  • ADLINK PCIe-7432 32 channel isolated I/O card interrupt and driver
  • ADLINK PCIe-7256 Industrial I/O Card Interruption and Relay
  • ADLINK PCIe-833x EtherCAT Motion Controller Debugging and Maintenance
  • ADLINK PCIe-10GPoE 10GigE Visual Acquisition Card Practical Use
  • ADLINK PCI-8254/8258 Motion Controller Debugging and Maintenance
  • Application and Maintenance of ADLINK PCI-8158 Multi axis Motion Control Card
  • ADLINK PCI-8134A Maintenance and Troubleshooting Guide
  • ADLINK PCI-7250 Series Relay Output Card Configuration and Protection Circuit Guide
  • ADLINK PCI-6308 Series Isolated Analog Output Card Configuration and Programming
  • ADLINK PanKonix Series HMI Panel Selection and Deployment Guide
  • ADLINK NuDAM-6100 Series I/O Module Deployment and Protocol Optimization
  • Deployment and Calibration of ADLINK NuDAM-6000 Data Acquisition Module
  • ADLINK NEON-2000-Ono Intelligent Camera Deployment and Trigger Optimization
  • ADLINK NuDAM-65xx Communication Module Networking and Configuration Guide
  • ADLINK NuDAM-60xx Series Digital I/O Module Deployment and Watchdog Optimization
  • ADLINK MXE-5300 Fanless Industrial Control Computer Deployment and Troubleshooting Manual
  • ADLINK MXE-310 edge computing Platform Hardware Installation and BIOS Tuning
  • ADLINK MXE-230 series Alder Lake platform industrial computer deployment and maintenance manual
  • ADLINK MXE-210 Compact Fanless Industrial Control Computer Hardware Deployment and Debugging Guide
  • ADLINK MXC-3300/3340 Embedded Industrial Control Computer Hardware Integration and Debugging Manual
  • ADLINK MXA-312M Edge AI Platform Hardware Integration and Debugging Guide
  • ADLINK MXA-200 IoT Gateway Hardware Installation and Linux System Debugging Complete Guide
  • ADLINK MVP-6200 Industrial Control Computer: PCIe Gen4 and PCI Hybrid Expansion
  • ADLINK MVP-6100 Industrial Control Computer: PCI/PCIe Expansion and Robust Design
  • ADLINK MVP-5200 Industrial Control Computer: High Performance Multi Display and TSN Network
  • ADLINK MVP-5100 Fanless Industrial Control Computer Deployment and Development Guide
  • ADLINK MVP-3100 and MVP-3120 Embedded Systems
  • ADLINK MNET-J3/S23/MIA/DA2/SAN Single Axis Module Installation and Wiring Guide
  • ADLINK MNET-4XMO/C Motion Module Installation and Debugging Guide
  • ADLINK MCM-216/218 Edge DAQ Deployment Configuration Guide
  • ADLINK LPCIe-8124-C Encoder Card Trigger Configuration Guide
  • ADLINK IM/OM Series Industrial Display Installation and Debugging Guide
  • ADLINK GW-01 Industrial IoT Gateway Configuration and Debugging Guide
  • EURESYS Grablink Collection Card Selection and Trigger Configuration Guide
  • ADLINK Express HL Module Selection and Heat Dissipation Configuration Guide
  • ADLINK EOS-2000 Visual System Installation and Troubleshooting
  • ADLINK EOS-1200 Installation, Configuration, and Troubleshooting
  • Application and Configuration of ADLINK ECS-8582-4S Extension System
  • ADLINK DIN-814P-A4 Panasonic servo adapter board configuration
  • ADLINK DIN-814M-J3A Mitsubishi servo adapter board configuration
  • ADLINK DIN-814-GP Universal Adapter Board Configuration
  • Application and Configuration of ADLINK DIN-812M Adapter Board
  • Application and Configuration of ADLINK DIN-814Y Adapter Board
  • ADLINK DAQ/DAQE/PXI-250x waveform generation complete guide
  • ADLINK DAQ/DAQE/PXI-220x acquisition card fully configured
  • Application and Configuration of ADLINK cPCI-9116 Data Acquisition Card
  • ADLINK cPCI/PCI-8554/R: A Complete Guide from Architecture to Application
  • ADLINK cPCI-7432/7433/7434 isolated I/O card
  • ADLINK cPCI-3544/3534/3538 Serial Cardcard Configuration Practice
  • ADLINK cPCI-3534/3538/3544 Multi Serial Port Card Configuration Complete Solution
  • Complete Technical Guide for Euresys Coaxlink CXP Capture Card
  • ADLINK AMP-304C Advanced Motion Control Card Complete Guide
  • ADLINK AMP-104C Four Axis Motion Control Card
  • ADLINK NEON-1020/1040 Smart Camera
  • ADLINK USB-7230/7250 Isolation I/O Module Operation Manual
  • ADLINK SP-15W03 Intelligent Panel Integration and Configuration Manual
  • ADLINK AMP-20xC Interface Configuration and Wiring Guide
  • ADLINK 3488A GPIB Interface Card Selection Guide
  • Complete solution of ETEL TMB+torque motor selection parameters
  • ADLINK RTV series frame grabber deployment guide