Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

ABB Baldor FlexDrive Servo Drives

F: | Au:FAN | DA:2025-04-01 | 858 Br: | 🔊 点击朗读正文 ❚❚ | Share:

ABB Baldor FlexDrive Servo Drives

Electrical Specifications

Input Voltage: Various specifications are available, such as 115VAC, 230VAC, 460/400VAC, etc. Different models are applicable to different voltage ranges with corresponding minimum and maximum voltage limits.

Input Frequency: Support 50/60Hz ±5% frequency.

Output parameters: output bus voltage, phase current, peak phase current, output power, output frequency, etc. vary by model. For example, some models have an output frequency range of 0 - 500Hz and efficiency greater than 95%.

Logic Power: For certain models (FDxAxxxx - xxx3), an external 20 - 30VDC logic power supply is required, and the input current and inrush current varies by model.

Control Specifications

Control Type: IGBT PWM sine wave control for precise motor control.

Feedback type: Supports resolver feedback (resolution is automatically set according to the speed, up to 14 bits) and encoder feedback (signal type RS422, maximum input frequency 125kHz).

Analogue Inputs: Analogue speed command and analogue torque command inputs from 0 - 10VDC or ±10VDC with 12 bit command signal resolution and 500ms update rate.

Pulse Inputs: Pulse/direction input signals from 12 - 29VDC, optically isolated, maximum input frequency 125kHz, cycle time 1ms.

Communication Specifications

Serial Interface: Supports RS232C (non-isolated, 9600 Baud) and RS485 (non-isolated, 9600 Baud) communication standards.

CAN bus (optional): Some models support CAN bus, following CAN_OPEN and DS301 protocols, with a default baud rate of 125kbit/second, which can be changed by AS1 switch setting or serial command.

Physical Specifications

Size and Weight: The size and weight of the drives vary from model to model, e.g., models A, B, and C are different from models E, G, and H. Models with the CAN option may have a slightly increased width.

Protection: IP20 rated to provide a degree of protection against dust and foreign objects.

Environmental Adaptability: Capable of operating over a range of altitudes, temperatures, and humidity. No derating is required up to 3300 feet (1000 metres) above sea level, and a percentage of derating is required above that; operating temperature range is 0 - 40°C, with derating required above 40°C, and a maximum ambient temperature of 50°C; storage temperature range is -25 - +70°C, and the humidity range is 10% - 90% non-condensing.

Other specifications


Regenerative Functions: Drives at different voltages have different parameters for regenerative functions such as switching threshold, rated/peak power, maximum regenerative switching current and maximum load inductance.

Installation Requirements: Pay attention to the connection method and tightening torque of each component when installing, for example, the tightening torque of the X1 connector is 0.5 lb - in (0.6Nm), and make sure to use the correct cables and connectors, and follow the relevant EMC installation requirements.

Product Notice Intended use:

These drives are intended for use in stationary ground based applications in

industrial power installations according to the standards EN60204 and VDE0160.

They are designed for machine applications that require variable speed controlled

three phase brushless AC motors.


These drives are not intended for use in applications such as:

-- Home appliances

-- Medical instrumentation

-- Mobile vehicles

-- Ships

-- Airplanes

Unless otherwise specified, this drive is intended for installation in a suitable enclosure. 

The enclosure must protect the control from exposure to excessive or corrosive moisture, dust and dirt or abnormal ambient temperatures. 

The exact operating specifications are found in Section 7 of this manual.

The installation, connection and control of drives is a skilled operation,disassembly or repair must not be attempted.

In the event that a control fails to operate correctly, contact the place of purchase


Safety Notice : This equipment contains high voltages. Electrical shock can cause serious or fatal injury. 

Only qualified personnel should attempt the start--up procedure or troubleshoot this equipment.

This equipment may be connected to other machines that have rotating parts or parts that are driven by this equipment. Improper use can cause serious or fatal injury. 

Only qualified personnel should attempt the start--up procedure or troubleshoot this equipment.

-- System documentation must be available at all times.

-- Keep non-qualified personnel at a safe distance from this equipment.

-- Only qualified personnel familiar with the safe installation, operation and

maintenance of this device should attempt start-up or operating procedures.

-- Always remove power before making or removing any connections to this contro


PRECAUTIONS: Classifications of cautionary statements.

WARNING: Indicates a potentially hazardous situation which, if not avoided,could result in injury or death.

Caution: Indicates a potentially hazardous situation which, if not avoided,could result in damage to property

WARNING: Do not touch any circuit board, power device or electrical connection before you first ensure that power has been

  • Basler D90 96801 100 PCB Card
  • Basler XR2002F Voltage Regulator (110 VAC, 48-480 Hz)
  • Basler SR8A-2B14B3A Regulator
  • Basler 9561500100 Module
  • Basler DECS-400 BE1-11 System
  • Basler DECS-100-B15 Excitation Control
  • Basler SCP 210 Frequency Controller
  • Basler SR4A-2B15B3A Static Voltage Regulator
  • Basler BE1-32R Power Relay
  • Basler PIA2400-17GM Power Interface Adapter
  • Basler MVC 232 Manual Voltage Control Module
  • Basler SSR 32-12 Static Voltage Regulator
  • Basler 5MW AVR Generator Voltage Regulator
  • Basler VR63-4B Voltage Regulator
  • Basler DECS-100-A05 AVR for Engine Generator
  • Basler DECS-100-B15 Automatic Voltage Regulator
  • Basler BE1-32R Directional Power Relay
  • Basler BE1-87B Differential Relay
  • Basler UFOV 260A Protective Module
  • Basler 9-2614-02-100 PCB Rev M
  • Basler DECS-100-B15 Digital AVR
  • Basler 9284900103 PS DECS-400N
  • Basler D4N3H1U Intertie Protection
  • Basler DECS-100-B15 A15 AVR
  • Basler KR4F Voltage Regulator
  • Basler BE26434 T14 Transformer
  • Basler SR8A-2B15B3A Regulator
  • Westinghouse 774B472A12 AR Relay
  • Basler DECS-100-B15 AVR
  • Basler XR2002F Regulator 110V
  • Basler SR125-E Static Regulator
  • Basler SSR 125-12 Regulator
  • Basler MOC2599 Motor Pot
  • Basler BE1-DFPR Feeder Relay
  • Basler CBS 305 Current Boost
  • Basler BE1-25 AutoSync
  • Basler MVC 300 Voltage Control
  • Basler BE3-25A AutoSync
  • Basler KR7FF Static Regulator
  • Basler 90-49000-100 Regulator
  • Basler 880 kVA Dry Type Transformer Specs
  • Basler Electric BE1-25 Sync-Check Relay Specs
  • Basler SSR 125-12 Voltage Regulator Specs
  • Basler Electric BE1-851 Overcurrent Relay Review
  • Basler Electric 149D930G02 Control Sub-Assembly
  • Basler Electric BE1-81O/UT Frequency Relay Specs
  • Basler Electric BE1-51/27C Overcurrent Relay
  • Basler Electric 149D956G02 Industrial Component
  • Basler Electric BE1-51A Overcurrent Relay Specs
  • Basler Electric BE1-40Q Loss of Excitation Relay
  • Basler DECS-200 Excitation Control System
  • Basler DECS-200 Voltage Regulator 56-277V AC / 125V DC
  • Basler BE1-87T Transformer Differential Relay
  • Basler RDP-110-S1 Protection Relay
  • Basler BE1-700V Digital Protective Relay
  • Basler BE1-951 Overcurrent Protection System
  • Basler DECS-300 Digital Excitation Control
  • Basler DECS-200 Digital Excitation Control
  • Basler DECS-200-1C Excitation Control System
  • Basler DECS-200-1L Digital Excitation Control
  • Basler Electric BE1-GPS Generator Protection System
  • Basler Electric DECS-200-1C Digital Excitation Controller
  • Basler Electric DECS125-15 Excitation Control with Power Module
  • Basler Electric BE1-87G Differential Relay
  • Basler Electric BE1-11 Protection System I5A3M2P2N0EA00
  • Basler Electric DECS-200-1C Excitation Control System
  • Basler Electric BE1-11g Generator Protection Relay
  • Basler Electric DECS 125-15-B2C1 V2.0.9 Excitation Control
  • Basler Electric BE1-81O/UT3ED1JA7N2F Frequency Relay
  • Basler Electric BE1-81O/UT3EE1YB7N1F Frequency Relay
  • Basler Electric DECS-200-1L Digital Excitation Control System
  • Basler DECS125-15-B2C1 Excitation Control
  • Basler 9507900205 SSR Retrofit Voltage Regulator
  • Basler BE2000E Digital Voltage Regulator
  • Basler BE1-GPS Generator Protection System
  • Basler DECS-250-CN1CN1N Digital Excitation Control
  • Basler DGC-2020 Genset Controller
  • Basler BE1-81O UT3ED1LA7N0F Frequency Relay (Variant)
  • Basler BE1-81O UT3EE1YA9S0F Frequency Relay (Variant)
  • Basler BE1-81O Over/Under Frequency Relay
  • Basler DECS125-15 Digital Excitation Control
  • Basler Electric BE1-951 Overcurrent Protection System
  • Basler Electric BE1-700V Digital Protective Relay
  • Basler Electric APR63-5 Automatic Voltage Regulator
  • Basler Electric BE1-851 Overcurrent Protection System
  • Basler Electric DECS-250-LN1SN1N Excitation Control
  • Basler Electric BE1-87T Transformer Differential Relay
  • Basler Electric DECS-200-1L Excitation Control System
  • Basler Electric 9310300100 DECS-300 Excitation Control
  • Basler Electric SSE-N 125-4.5KW Shunt Exciter Regulator
  • Basler Electric DGC-2020HD-5NS1DNSBA Genset Controller
  • Basler Electric BE1-81-O/UT3EE1JB7N1F Frequency Relay
  • Basler Electric BE1-81T1EE1WA0N1F Frequency Relay
  • Basler Electric BE1-25M1EA6PN5R1F Sync-Check Relay
  • Basler Electric BE1-GPS Generator Protection System
  • Basler Electric DECS-250-LN1SN1N Excitation Control Rev V
  • Basler Electric DECS-250-CN2CN1N Excitation Control
  • Basler Electric BE1-50/51B-207 Overcurrent Relay
  • Basler Electric DECS-300-C0N0 Excitation Control System
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric DECS-250-LN1CN1N Excitation Unit
  • Basler Electric DECS-250 LN2SA1D Excitation Unit Specs
  • Basler Electric BE1-87T Transformer Relay Review
  • Basler Electric BE1-11 Protection System
  • Basler Electric BE1-GPS100-E4N1H1N Protection System
  • Allen-Bradley 442G-MABH-R Safety Module
  • Beckhoff CX1030-0111 PLC Assembly Profile
  • FANUC IC693CPU364 PLC Module
  • Orange Denmark Type 200816 220 PLC Specs
  • OMRON C200H-SNT31 Sysmac PLC Module
  • Allen Bradley 20AB022A3AYNANC0 PowerFlex 70
  • OMRON C200HW-PCU01 Position Control Unit
  • ABB AO845A-eA Analog Output Module
  • OMRON CJ1M-CPU22 CPU Unit
  • Allen Bradley 100-E265ED11 Contactor
  • Honeywell 51304511-100 Interface Module
  • SOLEXY BXF3S0101N0018 Gateway Module
  • OMRON CJ2H-CPU65 CPU Unit
  • Automation Direct GS2-45P0 AC Drive
  • M68-2000 2-Axis Motion CNC Controller
  • OMRON CJ1M-CPU11 V3.0 PLC CPU Unit
  • OMRON CJ1W-NC413 4-Axis Positioning Controller
  • OMRON 3G2A3-PRO16 Programming Console HMI
  • Siemens 3VT8440-2AA04-2GA2 Molded Case Circuit Breaker
  • Siemens 3RT5045 Contactor Series
  • OMRON C200HS-CPU01-E SYSMAC PLC Controller
  • OMRON C500-NC103-E Positioning Control Unit
  • OMRON CJ1W-TC001 Temperature Control Unit