Product Overview

The 1510 Node Box PC Computer System offers a powerful, compact package for the factory floor and other harsh environments. 

The 1510 features an openarchitecture to meet a wide variety of applications that require both a powerful PC and a durable industrial enclosure. 

The system integrates a 80 GB hard drive, 10 slot passive backplane, and CDRWDVD ROM in a truly industrial form.

The system’s highly expandable design allows easy access to expansion boards,jumpers, power supply, and disk drives.


Standard Features

The 1510 offers the following standard features:
• Panel or shelf mountable, horizontally or vertically
• Intel Socket 478 Pentium 4 3.0 GHz, 512 KB cache, 400 MHz System Bus

• 10 slot passive backplane with the following available expansion (4 slots are dedicated to the CPU):

• two full length ISA  
• three full length PCI
• one half length PCI length
• Status LEDs
• Power
• Hard Disk activity
• CDRW/DVD ROM activity etc…
• External connection ports
• 2 serial ports (Two RS-232 ports)
• One parallel port
• PS/2 keyboard and mouse ports (use of both via Y-cable)  
• VGA port
• Audio (In, Out, Mic)
• Two USB 2.0 ports
• One 10/100 Base T Ethernet port and one 10/100/1000 Base T Ethernet port.
• 4X AGP graphics controller with up to 8MB and up to 64MB from system
RAM; Dynamic Video Memory support.
• Front accessible CDRW/DVD ROM drive
• Front accessible 3.5-inch (1.44 MB) internal floppy drive
• 80 GB internal hard drive (minimum)
• Integrated PCI IDE  
• Power switch (refer to warning in Quick Startup section of this chapter)

• Award 4MB Flash BIOS


Optional Features

184-Pin DDR SDRAM
• 512 MB DDR SDRAM
• 1 GB DDR SDRAM
• 2 GB DDR SDRAM
Operating Systems
• Windows® 2000
• Windows® XP Professional
Unpacking the System

When you remove the 1510 from its box, verify that you have the parts listed below. 

Save the box and inner wrapping in the event you need to reship the unit.

• 1510 unit
• Documentation kit, which includes:
• Diagnostic software disk (units shipped with MS-DOS only)
• Documentation Support Library CD (documentation and drivers)
• 1510 manual
• Drivers
• Pro-face/Xycom Recovery Media and documentation for Windows 2000.
• Installation disk for Windows XP (if applicable)
• AC power cord
• Mounting Hardware:
• Four 10-32 x 5/8 screws
• Mounting brackets for vertical or horizontal mounting
• Miscellaneous:
• Screws
• Cables
• Ties
• Feet
Quick Start-up
This section gives you the steps to get the 1510 up and running without explaining the capabilities and options of the system.
Warning
Turn off the power to the unit and disconnect the power cord before adjusting the inside or the outside of the computer.
To prepare the system for use, perform the following steps:
Attach a keyboard to the keyboard port.  
Attach other optional equipment following the instructions in Chapter 2.
Attach a monitor to the VGA connector.
Attach the power cord from the power receptacle to a properly grounded 115
230 VAC, 50-60 Hz outlet.
Turn on the power to the unit.  
The system will boot up at the C: prompt.
Install application software that you will use onto your system via the CD-ROM drive or network.
The following instructions describe the installation of ISA or PCI expansion boards.
Turn off power to the unit and unplug the power cord on the rear of the 1510.
Check that the board’s memory and I/O configuration do not conflict with the CPU and I/O memory maps in your CPU board manual.

Remove the side panel. With the front of the unit facing you, lay the 1510 on its right side. 

Remove the eight screws that hold the left side panel in place.

Remove the ORB screw and blank ORB from the desired track (see figure 2–5).
Remove the two screws from the hold down bracket and remove the hold down bracket (see figure 2–5).
Slide the ISA or PCI expansion board into the desired slot.
Push the board into the backplane connectors.
Use the clamps included in the kit shipped with your unit to secure the board to the hold down bracket (see figure 2–5).


Mounting Considerations

This section describes issues you must address before placing the 1510 inside an enclosure.
Consider the following points and precautions:
• Select an enclosure and place the unit in a position that allows easy access to the 1510 ports.
• Account for the unit’s depth when choosing the depth of the enclosure.
• The unit must be mounted in an approved fire and electrical enclosure.  
• The 1510 can be mounted in a vertical or horizontal position. See Mounting
Brackets and Mounting Dimensions, and Mounting the Unit in Chapter 2.
• Consider locations of accessories such as AC power outlets for installation and maintenance convenience.
• Prevent condensation by installing a thermostat-controlled heater or air conditioner.
• To allow for maximum cooling, avoid obstructing the airflow.

• Place any fans or blowers close to the heat generating devices. If using a fan, ensure that outside air is not brought inside the enclosure unless a fabric or other reliable filter is used. 

This filtration prevents conductive particles or other harmful contaminants from entering the enclosure.  (Continued on the next page)

• Do not select a location near equipment that generates excessive electromagnetic interference (EMI) or radio frequency interface (RFI) (equipment such as high power welding machines, induction heating equipment and large motor starters).
• Place incoming power line devices (such as isolation or constant voltage transformers, local power disconnects, and surge suppressers) away from the
1510. The proper location of incoming line devices keeps power wire runs as short as possible and minimizes electrical noise transmitted to the 1510.
• The power cord outlet must be installed near the equipment and shall be easily accessible.
• Avoid overloading the supply circuit.
• Incorporate a readily accessible disconnect device in the fixed wiring for permanently connected systems.
• Make sure the location does not exceed the 1510’s shock, vibration, and temperature specifications.

Mounting the Unit

Once the mounting considerations in this chapter have been met, mount the 1510 according to the following instructions:
Locate a position for your 1510 that meets the specifications required.
Refer to the Mounting Dimensions (figure 2–6 or 2–7) as a guide for mounting your system.

Mount and secure the 1510 unit, if required, using the mounting brackets.  

Refer to the section titled Securing the Mounting Brackets for information about attaching mounting brackets to the 1510.    

Attach one end of the power cord to the power receptacle and the other end to a properly grounded 115-230 VAC, 50-60 Hz outlet.  

Implement the proper grounding techniques. 

Establish a ground path from the 1510 chassis to the enclosure chassis. A 6-32 threaded ground point hole is provided on the left back of the front panel (as viewed from the front) of the unit.

There is also an internal ground point  Turn on the power. 

The system will boot up to the operating system installed.

Install application software via a floppy drive or CD-ROM type drive.

NEW XYCOM 9450-27B1319010000 OPERATOR PANEL 945027B1319010000 - SB ...

  • BENTLY 1-536067-4 Proximitor Connector Lead
  • BENTLY 3500/34 125696-01 TMR Relay Module
  • BENTLY 125704-01 3500/32M I/O Module
  • BENTLY 126632-01 Keyphasor I/O Module
  • BENTLY 3500/25 125792-01 Keyphasor Module
  • Bently Nevada 2300/25-00 Vibration Monitor
  • Bently Nevada 3500/05-01-03-00-00-00 Rack
  • Bently Nevada 3500/42M 140734-02 Monitor
  • Bently Nevada 123M4610 Accelerometer
  • Bently Nevada 3500/05-02-04-00-00-00 Rack
  • Bently Nevada 3500/53 133388-01 Overspeed Detection Module
  • Bently Nevada 3500/32 125712-01 Relay Module for Machinery Protection
  • Bently Nevada 3500/20 125744-02 Rack Interface Module
  • Bently Nevada 3500/40M 140734-01 Proximitor Monitor Module
  • Bently Nevada 3500/60 163179-01 Temperature Monitor Module
  • BENTLY 3500/22M 288055-01 Enhanced TDI Module
  • BENTLY 3500/22M 146031-01 TDI Module
  • BENTLY 133396-01 3500/22M I/O Module
  • BENTLY 3500/34 TMR RMS Interface Module
  • BENTLY 128275-01-E Proximitor I/O Module
  • Bently Nevada 128276-011 Proximity Probe
  • Bently Nevada 135489-03 Accelerometer
  • Bently Nevada 135473-01 Seismic Transducer
  • Bently Nevada 1900/55 General Purpose Monitor
  • Bently Nevada ASSY78462-01U Proximitor Assembly
  • Bently Nevada 330100-90-01 Proximity Probe for Vibration Monitoring
  • Bently Nevada 330100-90-00 Proximity Probe for Machinery Monitoring
  • Bently Nevada 132419-01 Proximitor Sensor for Vibration Monitoring
  • Bently Nevada 10244-27-50-01 Proximity Probe Extension Cable
  • Bently Nevada 22810-01-05-50-02 Proximity Probe System
  • BENTLY 330980-51-00 3300 NSv Proximitor Sensor
  • BENTLY 330130-045-00-00 3300 XL Extension Cable
  • BENTLY 1X35668 Replacement Internal Module
  • BENTLY 3300/16 Dual XY Vibration Monitor
  • BENTLY 3500/15 133292-01 High Availability Power Supply
  • Bently Nevada 3500/62 163179-03 Process Monitor
  • Allen-Bradley 80190-100-01-R*3 Output Module
  • Allen-Bradley 80190-099-01 Analog Module
  • Allen-Bradley 80190-479-01 I/O Module
  • Allen-Bradley 80190-480-01-R Control Module
  • Bently 3500/15 125840-01 Power Supply Module
  • Bently 24765-02-01 Signal Conditioner Module
  • Bently 330130-085-00-00 Extension Cable
  • Bently 3500/22M 138607-01 Vibration Monitor Module
  • Bently 146031-02 Proximity Probe Sensor
  • BENTLY 330104-00-05-10-02-CN Proximity Probe
  • BENTLY 125768-01 3500 I/O Module Interface
  • BENTLY 3500/92 136180-01 Communication Gateway
  • BENTLY 84152-01 Proximitor Sensor Cable
  • BENTLY 3300/20 Dual Driver Proximitor Housing
  • BENTLY 3300/16-11-01-03-00-00-01 16-Channel Monitor
  • DEIF PPU-3 Power Protection Unit for Genset Control
  • DEIF RMV-112D Reactive Power Divider and Voltage Matching Relay
  • DEIF OPM-1 Output Protection Module for Gensets
  • DEIF IPM-1 Integrated Protection Module for Generators
  • DEIF CM-2 Control Module for Industrial Power Systems
  • DEIF PSM-1 Power System Manager Module
  • DEIF DELOMATIC-3 DGU2 Automatic Generator Control Unit
  • DEIF DLQ144-PC-NB Power Monitoring Meter
  • DEIF DU-2/MKIII Voltage Relay Controller
  • DEIF IOM4.2 Input/Output Module for Power Management
  • DEIF SCM-1 Synchronizing Control Module
  • DEIF GPU/2/GS Genset Parallel Unit Controller
  • EMERSON PR6426/010-110 CON021 Proximity System
  • EMERSON PR6423/011-110+C0N021 Proximity Sensor System
  • DEIF LSU-112DG Load Sharing Unit
  • DEIF PCM4.4 Advanced Power Control Module
  • DEIF TAC-311DG Transducer for AC Voltage
  • DEIF SCM4.1 Engine Start Control Module
  • DEIF PCM4.3 Power Control Module
  • Emerson 2500M/AI4UNIV Universal Analog Input Module
  • Emerson PR6424/011-140 Eddy Current Sensor
  • Emerson KJ3242X1-BK1 12P4711X042 Analog Input Module
  • Emerson FX-316 960132-01 Control Processor Module
  • Emerson KJ4006X1-BD1 Power Supply Module
  • EMERSON 1C31181G01 Ovation Analog Output Module
  • EMERSON CE4003S2B6 DeltaV Analog Module
  • EMERSON KJ4001X1-CK1 DeltaV I/O Carrier Card
  • EMERSON VE4012S2B1 DeltaV I/O Module Specifications
  • EMERSON SS6501T01 DeltaV System Assembly Technical Overview
  • Emerson A6370D/DP Display
  • Emerson P188.R2 Power Supply
  • Emerson A6824R 24-Ch Relay
  • Emerson KJ2201X1-JA1 Serial
  • Emerson VE3008 Main Controller
  • Emerson VE3008 CE3008 KJ2005X1-MQ1 Controller Module
  • Emerson TPMC917 Embedded Processor Module
  • Emerson P152.R4 Industrial Control Module
  • Emerson DA7281520 P152 Power Module
  • Emerson PR6423/008-110 Eddy Current Sensor
  • EMERSON 5X00273G01 Ovation DCS Digital Output Module
  • EMERSON KJ4001X1-NB1 12P3368X012 REV:E Redundant Controller Backplane
  • EMERSON KJ4001X1-NA1 12P3373X012 REV:C Intrinsically Safe Interface
  • EMERSON KJ4001X1-BE1 12P0818X072 REV:L DeltaV I/O Carrier
  • EMERSON KJ2221X1-BA1 DeltaV SIS SISNet Repeater Module
  • EMERSON PR6423/000-131 Eddy Current Sensor
  • EMERSON 5X00790G01 Ovation Digital Output Module
  • EMERSON 5X00846G01 Ovation Analog Input Module
  • EMERSON KJ4110X1-BA1 DeltaV Power Supply Base
  • EMERSON CSI3125 A3125/022-020 Dual Channel Monitor
  • EMERSON A6740 Displacement Case Expansion Monitor
  • EMERSON A6312/06 Speed Monitoring Module
  • EMERSON KJ4001X1-BE1 DeltaV Carrier Module
  • EMERSON SE3008 KJ2005X1-MQ2 DeltaV Controller
  • EMERSON KJ4001X1-CA1 DeltaV Terminal Block
  • Emerson PR6423/00R-010 CON031 Eddy Current Probe System
  • Emerson A6824 9199-00090 Operator Workstation
  • Emerson A6410 9199-00005 Operator Workstation
  • Emerson A6110 9199-00001 Operator Workstation
  • Emerson 9199-00002 A6120 Operator Workstation
  • Emerson KJ3002X1-BF1 12P1732X042 FIELDVUE DVC6200
  • Emerson 5X00500G01 Ovation Analog Output Module
  • Emerson VE4001S2T2B4 DeltaV Controller Module
  • Emerson 5X00502G01 Ovation Analog Input Module
  • Emerson A6824R 9199-00098-13 Operator Workstation
  • EMERSON A6140 9199-00058 Dual Channel Monitor
  • EMERSON VE3007 KJ2005X1-BA1 DeltaV Controller
  • EMERSON DB1-1 Connection Termination Block
  • EMERSON PMC-IO-ADAPTER Mezzanine Interface Card
  • EMERSON L0115012 L0115032 Solenoid Valve Components
  • Emerson A6410 Large Operator Workstation
  • Emerson A6210 Operator Workstation
  • Emerson 1C31232G02 Ovation Controller Module
  • Emerson 5X00106G02 Ovation Power Supply Module
  • Emerson 5X00106G01 Ovation Power Supply Module
  • EMERSON PMC-IO-PROZESSOR High-Speed I/O Module
  • EMERSON PMC PROFINET Communication Module
  • EMERSON MVME7100-0171 VMEbus Single Board Computer