32 isolated digital signal interfaces: such as RSM-32 PLC C 1CO, with enhanced insulation between input/output (basic insulation between contacts), status indicators (LED), screw or tension clamp connections, etc. Technical and ordering data are also set according to their own characteristics.
MICRO - INTERFACE Solution
1. Overview
MICRO - PLC adapter is used to connect MICROSELES series relays and optocoupler modules to PLC or other controllers through pre assembled cables. The adapter is formed by a 15 pole SUB-D connector or a 10 pole ribbon cable, which can be connected to a set of 8 MICROSYSTEMS relay/optocoupler modules (with screws or tension clips).
2. Selection guide for different brands of PLCs
be directed against GE Fanuc 90 - 30、RX3i、OMRON CJ1W、Rockwell Compact Logix、Control Logix、Schneider M340、MICRO - PREMIUM、Siemens S7 - 300/ET - 200M、S7 - 400 We provide a detailed selection guide for PLC brands, including manufacturer codes for PLC input/output cards, number/type of channels, order numbers and quantities for standard cables, connection methods (screw or tension clamp connections), order numbers and quantities for MICROADAPTER, and information on corresponding input or output relays.
email:1583694102@qq.com