Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

Honeywell CC-TCNT01 51308307-175 Solution

F: | Au:FAN | DA:2025-07-31 | 782 Br: | 🔊 点击朗读正文 ❚❚ ▶ | Share:


Honeywell CC-TCNT01 51308307-175 Solution

Honeywell C300 related solutions

1. Overview

Honeywell C300 related solutions revolve around Expert ®  The core of the PKS C300 controller deployment lies in the application of new interfaces and pre assembled cables. IOTAs (Input Output Terminal Assemblies) adopt Weidm ü ller PCB connectors and terminal designs, with flexible connection methods. They can be directly wired to the field or combined with Weidm ü ller's FTAs (Field Terminal Assemblies) to use pre assembled cables.

Compared to traditional wire to wire wiring, this solution has significant advantages:

Reduce wiring workload: Minimize on-site wiring work by using pluggable connectors and cables.

Quick and easy connection: Pre assembled wiring harnesses can quickly and error free connect IOTA and FTA.

High current switching capability: The isolated digital output FTA has high current switching capacity in a compact design.

Clear identification: IOTA and FTA are equipped with the same Weidm ü ller connector and the same orientation for easy identification.

Excellent flexibility: Pre assembled cables can be made into different cross-sections, with lengths up to 50m.

Rich interface options: The Weidm ü ller interface provides multiple functions such as LED indicators, insulators, relays, or fuses, suitable for all C300 I/O cards.

2. Selection Guide

The selection guide aims to help users quickly and conveniently choose suitable products based on their application needs. The steps are as follows:

Step 1: Select the IOTA to use.

Step 2: Determine the number and type of cables required for the connection.

Step 3: Choose the interface that is most suitable for the application.

Taking CC-TDIL01 as an example, there are multiple options available. For example, option 1 can choose pre assembled cable C300-32B-320B (2 pieces) and interface 1221550000 (1 piece); Option 2 can choose pre assembled cables C300-32B-320B (2 pieces) and interfaces 1222980000 (2 pieces).

The selection guide table provides a detailed list of pre assembled cables (including cable type, required quantity per IOTA) and FTA (Weidm ü ller interface) information for different Honeywell IOTAs, covering card type, number of channels, connection method, whether to include LED per channel, whether to include disconnect and test points, whether to include fuse per channel, whether to include external power supply, required quantity per IOTA, and order number.

3. FTA C300 input/output passive interface

This type of interface is used to connect Honeywell C300 digital or analog IOTAs. The following is detailed information for some of the main models:

FTA-C300-32DI-LD: Suitable for CC-TDIL01 and CC-TDIL11, it is a passive input/output interface for digital cards. Technical data includes connection data and functions (control side connection, on-site connection, LED status display, etc.), rated data (working voltage, maximum current per channel, etc.), general data (ambient temperature, storage temperature, etc.), certification (CE, etc.), dimensions (clamping range, installation guide rail, length x width, etc.). There are two types of ordering data: screw connection and tension clamp connection, with corresponding order numbers. The accessories include 5x20 mm 0.63A fuses, etc.

FTA-C300-32DIOHV: Suitable for CC-TDIL01/11, CC-TDOB01/11, CC-TDI110/120/220/230, etc. The technical and ordering data are similar to the above, but there are slight differences in parameters for different application scenarios.

FTA-C300-16AI-TEST: Suitable for CC-TDIL01, CC-TDIL11, CC-TAIX01, CC-TAIX11, etc., it has the characteristics of disconnecting plug and testing point (diameter 2mm, used for voltage and current measurement) and M4 shielding connection. Its technical data and ordering data are also set according to its own functional characteristics.

Other models such as FTA-C300-32DO-LD、FTA-C300-32DO-FUSE、FTA-C300-16AI-SH、FTA-C300-16AO-SH、FTA-C300-16AO-TEST  Each has its own applicable IOTA model, detailed technical parameters, ordering information, and accessory requirements.

4. FTA C300 isolation interface (per relay)

Taking FTA-C300-32DO-RSLIM as an example, it is suitable for CC-TDOB01 and TDOB11 and is an isolated output interface for digital cards.

Technical data: including connection data and functions (control side connection, pole number, relay type, LED status display, etc.), rated input data (input voltage, input current, working voltage, etc.), rated output data (contact material, working voltage, maximum AC continuous current, etc.), general data (ambient temperature, storage temperature, etc.), certification (CE, etc.), dimensions (clamping range, installation guide rail, length x width, etc.).

Order data: Provide two types of screw connections and tension clamp connections, along with their corresponding order numbers.

Accessories: 5x20 mm 5A fuses, etc.


5. Interconnection cables

Used to connect CS300 cards to Weidm ü ller interfaces, it is divided into Premium series (with connector housing) and Basic series (without connector housing).

Technical data: rated data (wire/shielding capacity, wire/wire capacity), cable characteristics (cable type, material), general data (environmental operating temperature, storage temperature, etc.).

Ordering data: Models and order numbers for different types of cables such as 32 pole, 32 pole+4 pole, etc. The last 3 digits of the cable code indicate the length (e.g. ending with 100 indicates a cable length of 10m).

Cabling system with front-end adapter

Overview

The new Front End Adapter (FAD) is suitable for different PLC I/O cards and, when combined with Weidm ü ller's interface series, provides a more efficient method for on-site wiring of PLCs compared to traditional wire to wire wiring. Can be connected to standard active or passive interface series, or Weidm ü ller's MICROSYSTEMS relays or optocouplers.

Its characteristics include:

Wide range: The front-end adapter is suitable for various PLC I/O cards, such as Siemens S7-300 and S7-400, Rockwell Control and Compact Logix, Ge Fanuc and Schneider, etc. Depending on the type of PLC I/O card, the cable can come with or without a casing.

Simple and safe: With the help of plug type connectors and cables, on-site wiring work is minimized to the greatest extent possible, with no wiring errors. Due to the use of a cable system instead of a single wire, the wiring inside the cabinet is clear.

High flexibility: FAD and pre assembled cables can connect multiple interfaces, and Weidm ü ller's interface series features interesting functions such as LED, fuse, disconnect device, relay, and optocoupler with manual coil connection (optional). The individual modules of the MICROSYSTEMS series can be assembled directly in groups of 8 and connected to the PLC through standard cables and corresponding PLC front-end adapters.

Time saving: Reduce planning and design time, and minimize the time required for debugging and troubleshooting.


FAD Selection Guide

1. General FAD selection table

Select the corresponding PLC front-end adapter (FAD), pre assembled cable (PAC), and interface module group based on the PLC manufacturer, PLC I/O card connector type, analog or digital I/O. For example, the Siemens S7-300 has an input/output card with a 20 pole connector, the FAD corresponding to the digital card is 1127840000 FAD S7/300 HE20 UNIV, the pre assembled cable is 7789806LLL, and the interface module group is RSF 20 GROUP.

2. Specific FAD selection table

Select the corresponding PLC front-end adapter (FAD), pre assembled cable (PAC), passive module, and interface module (relay module/optocoupler module) based on the PLC manufacturer, PLC I/O card, and required on-site system. For example, the 6ES7 321-1BH01-0AA0 card of Siemens S7-300 has an interface corresponding FAD of 1127850000 FAD S7/300 HE20 16 DIO, a pre assembled cable of 7789806LLL, and a passive module group of H2016 GROUP.

FAD front-end adapter for Siemens S7-300 and Rockwell Control Logix

1. FAD front-end adapter for Siemens S7-300

Suitable for Siemens S7-300 cards with 20 and 40 poles, such as FAD S7/300 HE20 UNIV、FAD S7/300 HE20 16 DIO、FAD S7/300 HE40 UNIV、FAD S7/300 2XHE20 32DIO、FAD S7/300 HE40 32DIO  Wait.

Taking FAD S7/300 HE20 UNIV as an example, the technical data includes connection data (connection with the card, on-site connection), rated data (working voltage, maximum current per channel, etc.), general data (ambient temperature, storage temperature, etc.), certification (CE, etc.), dimensions (length x width), etc., with corresponding order numbers and applicable PLC card models.

2. FAD front-end adapter for Rockwell Control Logix

Suitable for Rockwell Control Logix cards with 20 and 36 poles, such as FAD CLTX HE20 UNIV、FAD CLTX HE20 16DI、FAD CLTX HE20 16DO、FAD CLTX HE40 UNIV、FAD CLTX 2XHE20 32DI、FAD CLTX HE40 32DI、FAD CLTX 2XHE20 32DO、FAD CLTX HE40 32DO  Wait.

Taking FAD CLTX HE20 UNIV as an example, the technical data includes connection data, rated data, general data, certification, dimensions, etc., and there are corresponding order numbers and applicable PLC card models.

5、 RSF PLC - Passive interface for digital signals

A passive interface used for transmitting 32 digital input/output signals, including 1-wire, 2-wire, and 3-wire digital signals.

1-wire digital signal interface: such as RSF PLC 1W 32IO, with signal grouping by byte (selected by jumper), selectable switching by positive or negative signal (selected by jumper), optional status indicator (LED) displaying working status and voltage, screw or tension clamp connection, and other features. Technical data covers connection data and functions, rated data, general data, certification, dimensions, etc., and has corresponding ordering data and accessory information.

2-wire digital signal interface: such as RSF PLC 2W 32IO, with characteristics and technical data similar to 1-wire, and adjusted parameters for 2-wire transmission mode.

3-wire digital signal interface: such as RS F40 NIT32 LMZF, which also has corresponding features, technical data, ordering data, and accessory information.

6、 RSM - Isolation Interface for Digital Signals

A relay digital output interface used to transmit electrical signals between PLC and the field through SIM cable or front-end adapter FAD, including interfaces for 16 and 32 isolated digital signals.

16 isolated digital signal interfaces: such as RSF40 16 RS OUT, with electrical insulation (using pluggable relays, interchangeable with solid-state relays), status indicators (LEDs), screw or tension clamp connections, and other features. Technical data includes connection data and functions, rated input data, rated output data, general data, certification, dimensions, etc., and corresponding ordering data and accessory information.

32 isolated digital signal interfaces: such as RSM-32 PLC C 1CO, with enhanced insulation between input/output (basic insulation between contacts), status indicators (LED), screw or tension clamp connections, etc. Technical and ordering data are also set according to their own characteristics.


MICRO - INTERFACE Solution

1. Overview

MICRO - PLC adapter is used to connect MICROSELES series relays and optocoupler modules to PLC or other controllers through pre assembled cables. The adapter is formed by a 15 pole SUB-D connector or a 10 pole ribbon cable, which can be connected to a set of 8 MICROSYSTEMS relay/optocoupler modules (with screws or tension clips).

2. Selection guide for different brands of PLCs

be directed against GE Fanuc 90 - 30、RX3i、OMRON CJ1W、Rockwell Compact Logix、Control Logix、Schneider M340、MICRO - PREMIUM、Siemens S7 - 300/ET - 200M、S7 - 400  We provide a detailed selection guide for PLC brands, including manufacturer codes for PLC input/output cards, number/type of channels, order numbers and quantities for standard cables, connection methods (screw or tension clamp connections), order numbers and quantities for MICROADAPTER, and information on corresponding input or output relays.

  • Applied Materials 0195-14157 CMP Tool Controller
  • Allen-Bradley SK-H1-PWRMOD-D590 Power Structure
  • Zebra RSR12-RG5G8G5G5A1A2B XSLATE R12 Rugged Tablet
  • LTI SC52.0040.0012.0000.0 Compact Servo Drive
  • LTI Tools LT4400-30 Twist Socket 1/2 inch Drive
  • Lust LTi CDE32.008 Position Controller
  • LUST B-DS 125.1 LTi Drives 181-00635 Module
  • LTI DRIVES MS100 Montageset 0927.0017
  • Lust LTi Servo One SO84.032.0043.0000.2 Drive
  • LTI CDF 30.008.C3.6 Drive Power Supply
  • LTI SC52.0040.0012.0000.0 Servo Drive
  • LTi Drive CDF30.002 Power Supply Fuse
  • LTI Tools LT-4621-D Deep Well Twist Socket
  • MOOG LTI CDE54.044.D Pitch Master Turbine Drive
  • LTI TOOLS LT-1460 Wheel Torque Extension Kit
  • LUST LTi SO82.004.0030.0000.2 Servo Drive
  • LTI MOTION SA54.0075.0033.0000.0 Servo Drive
  • LUST LTi CDE34.006 W2.0 BR Servo Drive
  • LUST LTi MOTION CDE34.044 W2.4 H13 Servo Drive
  • LUST LTi CDE32.008 W2.2.BR Positioning Controller
  • LUST LTi DRiVES B-DS 125.1 Braking Resistor
  • LTI MOTION CDE34.006.WXX.PC1 Servo Drive
  • LTI MOTION SO24.007.0030.1000.0 Servo Drive
  • Lust CDD34.005.C2.1 LTI Drive
  • LTI SC52.0040.0012.0000.0 Compact Servo Drive
  • LTI Tools LT4400-30 Twist Socket 1/2 inch Drive
  • Lust LTi CDE32.008 Position Controller
  • LUST B-DS 125.1 LTi Drives 181-00635 Module
  • LTI DRIVES MS100 Montageset 0927.0017
  • Lust LTi Servo One SO84.032.0043.0000.2 Drive
  • LTI CDF 30.008.C3.6 Drive Power Supply
  • LTI SC52.0040.0012.0000.0 Servo Drive
  • LTi Drive CDF30.002 Power Supply Fuse
  • LTI Tools LT-4621-D Deep Well Twist Socket
  • LTI Tools LT-1400C Wheel Torque Extension
  • LTI SO CM-P.0122.2015.1 Servo Drive SA000-13029N
  • LTI MOTION SC32.0075.1011.0000.0 Servo Drive
  • LTI MOTION SC34.0200.0011.0000.0-SL Servo Drive
  • LTI CDE34.017 W2.4 H18 Frequency Inverter
  • LTI SO CM-P.0122.2015.1 Servo Drive
  • LTI FLPF-142-3-12-560/T4 Servomotor
  • MOOG LTI CDE54.044.D Pitchmaster Turbine Drive
  • Lust LTi CDB34.003.C2.4 SH Servo Controller
  • LTI SC52.0040.0012.0000.0 Servo Drive
  • LTI SA52.0100.0033.0000.0 Servo Driver
  • LUST CDE 54.044.D Pitch Master Turbine Drive
  • Lust LTi Servo One SO84.032.0040.0000.2 Drive
  • LTi LSH-074-2-60-560/T1 P S4 B14.1R Servo Motor
  • LTI SC52.0040.0012.0000.0 Servo Drive
  • LTI CDS44.072.LC1.1.NF Servo Driver
  • LTI SO CM-P.0122.2015.1 Servo Drive
  • LTI MOTION SO24.007.0030.1000.0 Servo Drive
  • LTI MOTION SC34.0300.0011.0000.0 Servo Drive
  • LTI DRIVES GmbH MS100 Mounting Set 0927.0017
  • LTI CDB34.014 W2.4 BR SH Servo Driver
  • LTi Drives 0920.0034.14 Documentation DVD
  • LTI MOOG CDE54.044 Pitchmaster Frequency Converter 181-01019
  • LTI LSN-097-0960-30-560 Servo Motor
  • LUST LTI CDE32.008 W2.2.BR Positioning Controller
  • LTI Drives MS100 0927.0017 Assembly Set
  • LTI SO82.004.0030.0000.2 Servo Drive
  • LTI MOTION SC32.0040.1011.0000.0 Servo Drive
  • LTi Drives 0920.0034.14 Product DVD
  • LTI MOOG CDE54.044 Pitchmaster Servo Drive 181-01019
  • LUST LTI CDE34.017 W2.4 Servo Drive
  • Lust LTi Servo One SO84.032.0040.0000.2 Drive
  • LUST LTI SO84.012.0011.1700.2 Servo Drive
  • LTI LSN-097-0960-30-560 Servo Motor
  • LUST CDE 54.044.D Pitch Master Turbine Drive
  • LTI Luster SA54.0550.0033.0000.0 Servo Drive
  • LTI CDS44.072.LC1.1.NF Servo Driver
  • LTI DRIVES GmbH MS100 Assembly Set 0927.0017
  • LTi Drives DSM4-14.2-21R83-200 Servo Motor
  • LTI Motion SC52.0150.0012.0000.0 Servo Drive
  • LTI Motion LSP04-004-048-60-0PR1PY17E0440 Servo Motor
  • LTI KP300-R Drive Interface Operator Display
  • Lust LTI SO84.020.0002.0100.2 Servo Drive
  • LUST LTI CDD34.008.W2.1 CDD3000 Servo Drive
  • LTI MOTION SA54.0550.0033.0000.0 Servo Drive
  • LTI Drives MS100 0927.0017 Mounting Kit
  • LTi DRiVES LSP06-015-320-30-00H1MY170 Servo Motor
  • LTI MC6412 C1 D3 S12 Servo Drive
  • LUST LTi SO82.004.0030.0000.2 Servo Drive
  • LTi Drives LSP06-015-320-30-00H1MY170 Servomotor
  • LUST LTi CDE34.003 C2.0 Servo Drive
  • LUST LTi LSH-127-1-30-560 T1 Servo Motor
  • LTI MOOG CDE54.044 Pitchmaster Servo Drive
  • LTI Lock Technology 1237 Flip Socket Set
  • LTi LSP08-028-560-55-00H1MY1M0 Servomotor
  • Lust LTi CDE34.010.D2.4 Position Controller 10A
  • Lust LTi CDE34.010.D2.4 Positioning Controller 10A
  • LTi Drives FLPF-142-3-12-560/T4 Servomotor
  • LUST LTI Motion CDD54.045 W2.1 Servo Drive
  • LUST LTI CDD34.006.W2.2.PC1 Servo Drive
  • LTI KP200-XL Operator Panel Keypad 4 Key
  • Lust LTI CDE32.008 W2.2.BR Positioning Controller
  • LTI Servo One SO82.004.0030.0000.2 Drive Amplifier
  • LTI MOTION SC54.0550.0012.0000.0 Servo Drive
  • LTI LSN-097-0510-30-560 Servo Motor
  • LTi Drives 0920.0034.14 Product DVD
  • LTI SO82.004.0030.0000.2 Servo Drive
  • MOOG LTI CDE54.044 Pitchmaster Frequency Converter
  • LUST LTI CDE34.017 W3.0 Servo Drive
  • LUST LTi Drives CDS44.072 LC1.1 Servo Drive
  • LUST LTi DC1-3.0006.1000.0 Servo Drive
  • LTi LSMM13-100-4N-001 Servo Motor
  • LTI MOOG CDE54.044 Pitchmaster Servo Drive
  • LUST LTi Drives NFE12.3 Line Filter
  • LTI MOTION SC34.0100.1011.0000.0 Drive
  • LUST LTi LSH-074-2-30-560/T1 B S4 G6.1M Servomotor
  • LUST LTI CDE34.044W2.3 Servo Drive
  • LUST LTi LST-127-5-15-560/T1 S4 G12.1S Servomotor
  • Lust LTi MOTION CDE34.044 W2.4 H13 Servo Drive
  • LTI Servo One SO82.004.0030.0000.2 Drive Amplifier
  • Lust LTI CDE34.006 W2.4 V4.10-02 Servo Controller
  • LTI Drives Stromag FLP 20/0014-60 BA 1 Servomotor
  • Lust LTI CDE34.024.Wx.x.PC1 Servo Controller
  • LTI Drives FLP13-0395-30-AC2 9.5 kW Servo Motor
  • LTI CDB32.004-C2.0SH Servo Drive
  • LTi LSH-074-2-30-320/T1 1R Servo Motor
  • LTi DRiVES LSP08-028-320-30-BPH2MY17E0803 Servo Motor
  • LUST LTI SO24.007.0020.0000.1 Servo Controller
  • LTI CDE34.017.W3.0 Frequency Inverter
  • LUST LTi DRIVES LSH-097-0960-30-560/T1 Servomotor
  • LTi DRiVES LSP10-056-560-50-00H1MY 1M0 Servomotor
  • LTi DRiVES LSP08-028-320-55-00H1MY 170 Servomotor
  • LTI MC6432 C1 D3 S12 G20 Servo Drive
  • Keba LTi CDE32.008 C3.0 Frequency Inverter