Foreword

 CP450 is a Human Machine Interface (HMI) with a 10.4" TFT Liquid Crystal 

Display, and is water- and dust-resistant according to IP65/NEMA 4X (indoor use only). 

CP450 is CE-marked and meets your need to be highly transient-resistant while in operation. 

Also, its compact design makes connections with other machinery more flexible, thus achieving the optimal performance of your machines. 

CP400Soft is used to design applications of CP450; it is reliable, user friendly and compatible with many models.


 Safety Precautions

 Both the installer and the owner and/or operator of the operator terminal must 

read and understand this installation manual.

 General– Only qualified personnel may install or operate the operator terminal.– The operator terminal must be installed according to the installation instruc

tions.– The operator terminal is designed for stationary installation on a plane surface, 

where the following conditions are fulfilled:

 • no high explosive risks

 • no strong magnetic fields

 • no direct sunlight

 • no large, sudden temperature changes

 • for use in Pollution Degree 2 Environment

 • for use on the flat surface of Types 1 and 4X (indoor use only) enclosures– Never allow fluids, metal filings or wiring debris to enter any openings in the 

operator terminal. This may cause fire or electrical shock.– The operator terminal fulfills the requirements of article 4 of EMC directive 

2004/108/EC.– Storing the operator terminal where the temperature is lower/higher than 

recommended in this manual can cause the LCD display liquid to congeal/

 become isotopic.– The LCD display liquid contains a powerful irritant. In case of skin contact, 

wash immediately with plenty of water. In case of eye contact, hold the eye 

open, flush with plenty of water and get medical attention.


Power source– The operator terminal is equipped with a 24 V DC input. 

Supply power other than 24 V DC ± 15% will severely damage the operator terminal. 

Thus, check the power supply supporting the DC power regularly.

Grounding– Without grounding, the operator terminal may be severely affected by excess noise. 

Make sure that the grounding is done properly from the power connec tor at the rear side of the operator terminal. 

When power is connected, make sure that the wire is grounded.

Use a cable of at least 2 mm2 (AWG 14) to ground the operator terminal. 

Ground resistance must be less than 100 Ω (class3). 

Note that the ground cable must not be connected to the same ground point as the power circuit.

Installation Communication cables must be separated from power cables for operational circuits. 

Only use shielded cables to avoid unpredictable problems. 

During Use– Emergency stop and other safety functions may not be controlled from the operator terminal.

Do not use too much force or sharp objects when touching the keys, display etc.

Service and Maintenance– Only qualified personnel should carry out repairs.

The agreed warranty applies.– Before carrying out any cleaning or maintenance

operations, disconnect the equipment from the electrical supply.

Clean the display and surrounding front cover with a soft cloth and mild detergent. Replacing the battery incorrectly may result in explosion. 

Only use batteries recommended by the supplier.


Dismantling and Scrapping

The operator terminal or parts thereof shall be recycled according to local regulations.

The following components contain substances that might be hazardous to  health and the environment: lithium battery, electrolytic capacitor and display


Hardware design: Equipped with 10.4-inch TFT LCD display, clear display, easy to operate. 

The front panel has a protection rating of IP65/NEMA 4X (indoor use only), 

which is waterproof and dustproof and can adapt to certain industrial environments. 

With net dimensions of 297 mm × 222 mm × 52 mm and a weight of 1.9 kg, the product is compact and easy to install.

Performance Parameters: With a 32-bit RISC CPU, 8MB of flash memory, 

16MB of RAM, and 512KB of battery-powered memory for data/recipe storage, it meets the needs of a wide range of industrial applications. 

It is also equipped with a CF card port for easy data storage and transfer. 

For communication, there are multiple communication ports, COM1 is a 9-pin female connector for RS232/RS485, 

COM2 is a 25-pin female connector for RS232/RS422/RS485, COM3 is a 9-pin female connector for RS422/RS485, 

and it also has an Ethernet port and a USB interface, which makes it easy to connect and transfer data to and from other devices. 

data transmission with other devices easily.


Installation

Packing Contents: The package includes the CP450 operator terminal, 8 installation fasteners, a power connector, 

and the installation and operation manual.

Installation Environment: It should be installed in an environment without a high explosion risk, strong magnetic fields, direct sunlight, or sudden large - amplitude temperature changes. It is suitable for an environment with a pollution degree of 2 and a flat surface of Type 1 and 4X (indoor - use - only) enclosures.

Installation Steps: First, make sure the installation surface is flat and meets the requirements. Then, use the provided fasteners to fix the CP450. 

The installation depth is 51.6 mm, and the opening size is 286.0 x 211.0 mm.

Grounding: The operator terminal should be grounded with a cable of at least 2 mm² (AWG 14), 

and the grounding resistance must be less than 100 Ω (Class 3). 

Note that the grounding cable cannot be connected to the same grounding point as the power circuit.

Power Supply and Wiring: The CP450 is powered by 24V DC ± 15%. 

The power connector on the back of the operator terminal should be properly grounded. When connecting the power supply, make sure the ground is good. Communication cables must be separated from the power cables of the operating circuit and only shielded cables should be used.


Product Specifications

Dimensions: The front panel is 297.0 x 222.0 x 9.0 mm in size, and the net weight is 1.9 kg.

Communication Ports: COM1 is a 9 - pin female connector for RS232/RS485, COM2 is a 25 - pin female connector for RS232/RS422/RS485, 

and COM3 is a 9 - pin female connector for RS422/RS485. It also has an Ethernet port, 2 USB host ports, and 1 USB device port.

Memory: It has 8 MB of flash memory, 16 MB of RAM, a 32 - bit RISC CPU, 512 KB of battery - powered memory for data/recipes, and a CF card port.

Display: It features a color TFT liquid - crystal display with 64K colors, a resolution of 640 x 480 pixels, and a CCFT backlight with a lifespan of approximately 50,000 hours at 25 °C.


Operation

Self - Test: The CP450 can perform a self - test to check the hardware status.

System Menu: The system menu provides various functions, such as setting communication parameters, calibrating the touch screen, and downloading/uploading applications.

Keyboard: There are 8 keys on the CP450, including a menu key and 7 function keys (F1 - F7). 

The function keys can be defined in CP400Soft as "shortcut keys" for operations such as setting ON/OFF values and changing screens.

Bench and Function Tests: By setting dip switches SW3 and SW4 to OFF, the bench and function tests of the CP450 can be run.

Communication Parameter Settings: Communication parameters can be set either on the operator terminal or in CP400Soft. 

On the operator terminal, select F2 - Config in the system menu to set parameters.

Touch - Screen Calibration: Use the system menu command F4 - Set to calibrate the touch screen. 

Touch the upper - left and lower - right corners of the screen as prompted, and then touch the square in the center of the screen to complete the calibration.

ABB CP405 QUICK START MANUAL Pdf Download | ManualsLib

  • Hitachi LPT020A Industrial Power Module
  • Hitachi LPF240F Industrial Power Module
  • Hitachi LPU100A Industrial Power Unit
  • Hitachi PS6515 Industrial Power Supply Module
  • Hitachi PS6548 Power Supply Module
  • Hitachi LCE250B Communication Module
  • Hitachi LCE250A Communication Module
  • Hitachi LPA302P-1 Analog Input Module
  • Hitachi LPA210A Analog Input Interface
  • Hitachi LPA302A Analog Input Module
  • HITACHI PS6524 Switching Power Supply
  • HITACHI MPD310A Color Touch Screen HMI
  • HITACHI MPD110A Graphic Operator Terminal
  • HITACHI MPD060A Operator Interface Display
  • HITACHI LPP100A Power Supply Module
  • Hitachi LPD200A AC Drive Inverter
  • Hitachi LUD060A AC Drive Inverter
  • Hitachi LPD350A AC Drive Inverter
  • Hitachi LPD220A AC Drive Inverter
  • Hitachi LPA220A AC Drive Inverter
  • Hitachi LPA245A Analog Input Module
  • Hitachi LPU100H Central Processing Unit
  • Hitachi LYT000A Output Module
  • Hitachi LPF240A Power Filter Module
  • Hitachi LUD700A Display and Interface Unit
  • HITACHI LYA100A Analog I/O Module
  • HITACHI LYA220A Analog Input Module
  • HITACHI TD000A Temperature Controller
  • HITACHI LYA210A Analog Output Module
  • HITACHI LYD105A Digital Input Module
  • Hitachi LYA010A AC Drive Inverter
  • HITACHI 2-822037-A Servo Motor Controller
  • Honeywell CC-TAIM01 Analog Input Module
  • Honeywell 2104B2131 Temperature Transmitter
  • Honeywell 05704-A-0146 Industrial Pressure Transmitter
  • Honeywell 05701-A-0351 & 05701-A-0302 Control System Components
  • Honeywell 05701-A-0327 System 57 Interface Module
  • Honeywell S2024-2POS-SW2 Spring Return Actuator
  • Honeywell XFR824A Transformer Module 24VAC 40VA
  • Honeywell 05701-A-0284 & 05701-A-0302 System 57 Control Card
  • Honeywell SC-UCMX02 Universal Controller Module 51307198-276
  • Honeywell ISC-UCMX01 Safety Controller Module 51307195-175
  • Honeywell FC-SCNT02 Field Control Scanner Module
  • Honeywell FC-SCNT01 Field Control Scanner Module
  • Honeywell CC-TUIO41 Universal Input/Output Module
  • Honeywell CC-TUI041 Universal Input Module
  • Honeywell CC-PLAIH51 Analog Input HART Module
  • Honeywell XNX-UTAV-RNIF1 XNX Universal Transmitter
  • Honeywell FTA-T-02 Field Termination Assembly
  • Honeywell LG1093AA24 261A1812P012 Flame Amplifier Module
  • Honeywell CC-TCNT01 51308307-175 ControlNet Interface Module
  • Honeywell CC-TUI041 51306873-176 Universal Input Module
  • Honeywell 1569905-6131140220 Specialized Industrial Component
  • Honeywell QPP-0001 Quad Processor Pack Safety Manager
  • Honeywell PSU-240516 Power Supply Unit 24VDC 5A/16A
  • Honeywell CPB-0001 CPCHAS-0001 Control Processor Chassis
  • Honeywell SDO-0824 CCV1.3 Supervised Digital Output Module
  • Honeywell SDI-1624 CCV1.1 Digital Module
  • Honeywell IO-0001 CCV1.0 Interface Module
  • Honeywell IOCHAS-0001S I/O Chassis
  • Honeywell SAI-1620M CCV1.4 Analog Module
  • Honeywell EG1033AA Flame Detector
  • ABB PPD513 A2A-11165 Panel
  • Honeywell 51401497-100 FW25-92 LCN Interface Board
  • Honeywell 05701-A-0405 Digital Output Module
  • HONEYWELL XS824-25 Industrial Sensor Module
  • Honeywell 51120841-101 51120841-201 Power Filter Module
  • Honeywell CC-PUIO01 Module
  • HONEYWELL 0571-A-0328 Industrial Control Module
  • Honeywell 05701-A-0325 Series 57 Control Module
  • Honeywell 05701-A-0282 I/O Module
  • HONEYWELL TC-CCN014 Control Network Module
  • Honeywell 10310/1/1 09701 Safety Manager Controller Module
  • Honeywell GR-2C-DC24V Relay Module
  • HONEYWELL GR-4C-DC24V Relay Module
  • Honeywell GR-2C-AC230V Industrial General Purpose Relay
  • Honeywell SPS5713 Power Supply
  • HONEYWELL SC-TCMX01 51307198-175 Termination Module
  • Honeywell 05704-A-0121 05704-A-0122 05704-A-0131 Control Modules
  • Honeywell SC-PCMX01 Power Module
  • Honeywell SPS5785 51198651-100 System Power Supply
  • HONEYWELL CC-IP0101 51410056-175 Interface Module
  • Honeywell 51402455-100 Profibus Module
  • HONEYWELL 51402455-100 MP-DNCF02-200 Module
  • Honeywell 51403645-100 SBHM Static Buffer Hi-Memory Board
  • Honeywell 51401583-100 EPNI Module
  • Honeywell 51306673-100 EPNI Module
  • HONEYWELL 51196655-100 ACX633 Control Module
  • Honeywell 51403519-160 K4LCN-16 Processor Board
  • Honeywell 51305072-200 CLCN-A Module
  • Honeywell 51305896-200 NIM Modem | TDC 3000 Network Module
  • HONEYWELL 51305072-300 CLCN-B Network Module
  • Honeywell FC-PSU-UNI2450U Power Supply
  • Honeywell CC-MCAR02 Series C Carrier | Experion PKS Chassis
  • HONEYWELL SC-UCMX01 51307198-175 Control Module
  • Honeywell 51404170-175 I/O Module
  • Honeywell 51196653-100-RP Controller Processor Board
  • HONEYWELL 05701-A-0330 Gas Detection Control Module
  • Honeywell SPS5710 Power Supply Module
  • Honeywell FTA-T-21 Field Termination Assembly
  • HONEYWELL FTA-T-14 Field Termination Assembly
  • Honeywell 05701-A-0325 I/O Module
  • Honeywell GR-4C-AC230V Industrial Power Relay
  • HONEYWELL PGR-4C-E Ground Fault Protection Relay
  • HONEYWELL CC-TCNT01 Controller Module
  • HONEYWELL CC-TAIX01 Analog Input Module
  • Honeywell CC-TAIN01 Analog Input IOTA Module
  • Honeywell 51304487-100 Output Module
  • Honeywell J-MSC10 Motor Starter Communication Module
  • HONEYWELL 51304518-150 I/O Module
  • HONEYWELL J-DIM00 Digital Input Module
  • HONEYWELL FF-SB12E04K-S2 Safety Light Curtain
  • Honeywell 51404223-001 TDC 3000 Controller Board
  • Honeywell 51195066-100 I/O Module
  • KEBA CU313 Industrial Controller
  • KEBA AR281 Automation Panel
  • KEBA K2-200 CP253/W Central Processor | KeControl CPU Module
  • KEBA CU313A Control Unit
  • KEBA FB201 Fieldbus Interface Module
  • KEBA CU313 Control Unit | KeControl Processing Module
  • KEBA CU312/E Compact Industrial Controller
  • KEBA OP341/Y-1400 Industrial Operator Panel
  • KEBA IP706 Interface Processor Module
  • KEBA CP450 Operator Panel
  • KEBA CP033/Y Industrial HMI Panel
  • KEBA PS244 Power Supply Module
  • KEBA SI232 Safety Input Module
  • KEBA DO321 Digital Output Module | KeControl System