Reset the terminal cover, tighten the fixing screws (to avoid over tightening), fasten the stress relief accessory onto the cable and push it into the cable entry hole, and wipe off excess compound.
5. Installation of transmitter
If the water meter has installed a register: align the punch with the center of the sealing pin at the bottom of the register, strike with a hammer to break the pin head, and rotate the register counterclockwise by 1/4 turn to remove it.
Install the TRICON transmitter on the water meter and rotate clockwise to lock it; Place the register mounting ring (with four sets of circular grooves facing upwards) on top of the transmitter, align it with the notch on the transmitter terminal cover, and tighten it.
Place the register on the transmitter and mounting ring, rotate clockwise until locked; Insert the new sealing pin into the register base and transmitter base to prevent tampering.
Maintenance and troubleshooting
Core scenarios for troubleshooting
When the electronic flow indication is inconsistent with the mechanical register indication, follow the following steps to troubleshoot:
Abnormal handling measures for items to be verified
Whether the size and type of the transmitter, register, and water meter match, replace them with transmitters or registers that are compatible with the water meter
Does the register rotate smoothly after being installed on the transmitter? Replace or repair the register to solve the problem of excessive torque
Whether the transmitter wiring and power supply are correct, correct wiring errors, and troubleshoot power supply faults
Adjust and calibrate the compatibility and calibration status of the transmitter connection device as required