TEKTRONIX VX4240 VXIbus protocol waveform digitizer/analyzer module

来源: | 作者:FAN | 发布时间 :2025-11-19 | 8 次浏览: | Share:

TEKTRONIX VX4240 VXIbus protocol waveform digitizer/analyzer module

Product identity and applicable scenarios

Tektronix VX4240 is a modular waveform digitizer/analyzer based on the VXIbus protocol, designed specifically for C or D-sized VXIbus mainframes. Its core positioning is a high-precision, multifunctional signal measurement and analysis tool. It integrates a 12 bit A/D converter and RISC processor, which can be widely used in laboratory signal testing, industrial equipment monitoring, electronic system development, and other scenarios. It can complete the entire process of capturing, storing, and analyzing DC to high-frequency AC signals.


Detailed explanation of core technical parameters

1. Hardware core configuration

Specific specifications of hardware components

A/D converter with 12 bit resolution, 10 MHz sampling rate, supports high-precision conversion from analog signals to digital signals

The INMOS T800 floating-point transputer processor is responsible for signal analysis and module control

Memory configuration standard 256K word sampling memory; Optional 512K word (Option 01) or 1M word (Option 02) expansion memory

Storage module with 128K bytes of RAM (running memory) and 128K bytes of EPROM (program storage); Non volatile memory (storing calibration parameters)

Two BNC input interfaces (SIG IN+, SIG IN -) and one DB25S connector (S3) for input/output; Support TTL level triggered input/output, clock input/output, ARM input/output

2. Key parameters for signal capture

(1) Frequency and Sampling Performance

Frequency range: DC to 5 MHz, with a attenuation index of -3 dB ± 1 dB at the 5 MHz frequency point, a roll off of -6 dB/octave in the 5-10 MHz frequency band, and a roll off of -18 dB/octave in the 10-20 MHz frequency band.

Sampling frequency: Programmable range from 0.005 Hz to 10 MHz, supports three clock sources - internal clock, external clock (TTL level, 50 Ω load, DC to 10 MHz), VXIbus 10 MHz ECL clock.

Sampling interval: 100 ns to 200 s (100 ns step) in internal/external clock mode, with a minimum period of 100 ns for external clock.

Clock accuracy: The internal clock has an annual drift of 5 ppm, ensuring long-term sampling stability.

(2) Input feature configuration

Voltage range:

Calibration range: ± 0.5 V, ± 1 V, ± 2 V, ± 5 V, ± 10 V, ± 20 V, ± 50 V, ± 100 V (8 levels in total, higher accuracy).

Virtual range: Supports any non calibrated voltage range within 100V, and achieves 12 bit weight allocation through Tek's self-developed virtual range circuit, with better performance than some 14 bit digitizers.

Input type: differential input (CMRR common mode rejection ratio:>40 dB from DC to 1 kHz, typical value for 50 Ω load>50 dB, typical value for 1 M Ω load>60 dB), single ended input.

Coupling methods: AC coupling, DC coupling, and grounding are available, suitable for different signal types (such as AC coupling isolating DC components).

Input impedance:

50 Ω (± 1%, parasitic capacitance<20 pF): suitable for high-frequency signal measurement.

1 M Ω (± 3%, parasitic capacitance<20 pF): suitable for measuring low-frequency and high impedance signals.

929 k Ω (± 2%, parasitic capacitance<20 pF): Suitable only for voltage ranges of 50 V and 100 V.

Resolution (12 bits): The smaller the voltage range, the higher the resolution, such as 0.48828 mV/bit for ± 1 V range and 48.828 mV/bit for ± 100 V range.

(3) Trigger and delay control

Trigger source: Supports 5 types of trigger sources, which can be flexibly combined (AND/OR logic of any two trigger sources):

External TTL edge trigger (programmable positive/negative edge).

Dual voltage threshold triggering (± 0 to ± 100% full-scale, 8-bit resolution).

VXIbus TTL trigger (8-channel programmable trigger line selection).

The VXIbus command is triggered.

Software triggering (receiving T command to start).

Trigger mode:

Pre trigger (CP): Store data before triggering and store a specified number of samples after triggering.

Post trigger (CT): default mode, data is stored after triggering, and the default sample size is memory size -100.

Central Trigger (CC): The trigger event is located in the center of the memory, with half of the samples stored before and after.

Free Run (CF): Uncontrolled by trigger control, continuously sampling after receiving the T command until receiving the stop command.

Record mode (CR): Automatic re triggering, storing data according to the set number of samples/records, supporting up to 65534 records.

Trigger delay: Programmable range of 200 ns to 420 s (200 ns step), delay uncertainty ≤ 200 ns+1 sampling clock cycle, meeting the requirements of precise timing control.

Trigger heavy arming time: In recording mode, it is one sampling clock cycle and supports fast continuous sampling.

3. Signal analysis function (40+core functions)

(1) Time domain analysis function

Function Name Description

Calculate the difference between the steady-state high level (100% point) and steady-state low level (0% point) of the signal using peak to peak voltage (AK), and return the maximum/minimum/average values

Rise time (AR) measures the time it takes for a signal to rise from 10% steady state to 90% steady state, and returns the maximum/minimum/average values

Falling time (AF) measures the time it takes for a signal to drop from 90% steady state to 10% steady state, and returns the maximum/minimum/average values

Return the maximum/minimum/average value and corresponding address of the part where the overshoot (AO) signal exceeds 100% steady-state value

Return the maximum/minimum/average value and corresponding address for the part of the down rush (AU) signal below 0% steady-state value

Find the maximum/minimum voltage values and corresponding memory addresses within the specified sample range (AX/AM)

Pulse width (AW/AZ) measures the duration of pulse high/low levels, supports absolute zero or floating reference points, and returns maximum/minimum/average values

(2) Frequency domain analysis function

Function Name Description

FFT analysis (AC) fast Fourier transform, supports voltage (V) or power (dBm) units, can return maximum amplitude and frequency, harmonic parameters, etc

FFT+Hanning Window (AH) FFT with Hanning Window to reduce spectral leakage, suitable for non periodic signals

FFT+Blackman Harris Window (AQ) FFT with Blackman Harris Window, further suppressing spectral leakage and achieving higher resolution

Total Harmonic Distortion (THD) calculates the amplitude ratio of the fundamental wave to the first 5 harmonics, in dBc (relative to the carrier wave)

Signal to Noise Ratio (SNR) is the ratio of the fundamental amplitude to the amplitude of all non harmonic noise, measured in dBc

The difference between the fundamental amplitude and the maximum amplitude of the spurious signal (noise or harmonic) in the non spurious dynamic range (SFDR), measured in dBc

(3) Statistical and mathematical analysis functions

Function Name Description

Calculate the average voltage value within a specified sample range using the mean (AA)

The true RMS value (AT) calculates the true effective value of a signal (square root mean square), reflecting the actual power of the signal

The standard deviation (AS) reflects the degree of dispersion of sample data and can simultaneously return the proportion of data within the ± N σ range (N=1-9)

Integral (AI) calculation of the area under the signal curve (accumulated sample values multiplied by the sampling interval)

Differential (AD) calculates the difference between consecutive sample points, reflecting the rate of signal change

Cycle/Frequency/Duty Cycle (AY/AW/AZ) is based on zero crossing detection to calculate the signal cycle, frequency, and high-level duty cycle

(4) Recording and special analysis functions

Function Name Description

Record operation (AG) performs average, difference, and maximum/minimum value calculations on multiple records to generate new records

Single frequency DFT (AL) is a discrete Fourier transform for a specified frequency that returns amplitude (RMS) and phase (radians), supporting single/double precision

Zero crossing time (AZ) detects the zero crossing time of the signal, calculates parameters such as cycle and duty cycle, and the reference point is absolute zero

image.png

Installation and Operation Guide

1. Preparation and requirements before installation

(1) Tools and Environment

Essential tool: Phillips screwdriver.

Environmental requirements: The mainframe should provide sufficient heat dissipation (2.7 liters/second airflow, pressure drop of 0.19 mm H ₂ O, module temperature rise<10 ° C), operating temperature of 0 ° C~55 ° C, storage temperature of -40 ° C~85 ° C, relative humidity<75% (non condensing, 31 ° C~40 ° C).

(2) Switch settings (critical configuration, incorrect settings will cause module failure)

Description of switch name and position requirements

Logical address switch (S080) 1-255 (FFh is dynamically configured) base address calculation formula: [(64d × XYh)+49152d], it is recommended to match the slot number

The interrupt level switch (S081) 1-7 (0/8/9 disable interrupts) needs to match the interrupt handling level of the system controller

The Halt switch (S084) must be set to ON, otherwise the module cannot respond to VXIbus resource manager commands properly

The Bootstrap switch (S56) is set to OFF for factory testing purposes, and users do not need to adjust it

The memory size switch (S083) is preset by the factory and cannot be adjusted by oneself. It matches the hardware configuration of the memory

(3) Installation steps

Record the revised version of the module, serial number (top shield label), and switch settings, and fill in the installation checklist.

Confirm that the power supply of the host rack is turned off, and insert the module into any C/D size slot except for slot 0 (the D-size host rack should be adapted according to the host rack manual).

Tighten the module fixing screws to ensure that the front panel is grounded and avoid the risk of electric shock.

Connecting cables: The BNC interface uses RG58 coaxial cable to connect the device under test (UUT), while the DB25 interface can use CDS 73A-742P shielded connectors.

Check the overhead idle slot of the host: it needs to be covered with a blank panel to ensure heat dissipation; If there is a vacant slot on the left side of the module, the VME daisy chain jumper needs to be installed according to the host rack manual.

2. Basic operating procedures

(1) Parameter configuration (core command example)

Example Explanation of Operation Purpose Command

Set the sampling frequency F1E6 to 1 MHz (internal clock)

Configure input parameters VD5MF DC coupling, ± 5 V range, 50 Ω input impedance, differential input

Set the collection mode CR1000/50 recording mode, with 1000 samples per record and a total of 50 records

Configure trigger mode MP5.0 positive voltage threshold trigger (5.0 V)

Set the trigger delay D200E-9 to start sampling with a delay of 200 ns after triggering

(2) Sampling and analysis process

Sending configuration commands: Send parameter configuration command strings (up to 160 bytes in length, using<LF>or; Separate multiple commands.

Start sampling: Send the T (Trigger) command, the module enters the "standby" state (ARM LED lights up), and starts sampling after the triggering conditions are met (MIP LED lights up).

Data storage: Sampling data is stored in memory according to the set mode, and is automatically triggered again in recording mode until the set number of records is completed.

Signal analysis: Send A-series commands (such as AA calculating mean, AC executing FFT), and the module returns the analysis results.

Status query and error handling:

Send Q command to query module status (self-test results, sampling progress, trigger status, etc.).

Send the E command to read the error code (such as 02 indicating CPU memory failure, 08 indicating threshold out of range). The operation can only continue after the error code is cleared.

(3) Data output

Output format: Supports ASCII, binary, complement binary, ASCII block transmission (K option, block size 1-2500).

Address control: Supports automatic address increment/decrement, and can specify the offset address relative to the trigger point (- RAMsize to+RAMsize).

Step size setting: Optional 1-65536 sampling point step size, supports interval reading of data (such as reading 1 sample every 4 samples, suitable for multiplexing scenarios).

3. Self inspection and calibration

(1) Self checking function

Power on self-test: The module is completed within 5 seconds after power on, detecting core components such as CPU memory, A/D converter, and analog front-end. If it passes, the POWER LED will remain on and the SYSFAIL LED will turn off.

Command self-test: Send the S command to initiate an extended self-test (detecting all memory, calibration parameters, trigger circuits, etc.), and return to the default power on state after completion. The results can be obtained through the Q command (querying self-test status) or the E command (reading fault error codes).

(2) Calibration requirements and operations

Calibration cycle: It is recommended to calibrate every 12 months at operating temperature, and the module should be preheated for 10 minutes before calibration.

Calibration command:

KS [range]: Simultaneously calibrate the gain and offset within a specified voltage range (results stored in non-volatile memory).

KG [range]: Only calibrate the gain.

KO [range]: Only calibrate offset.

K [range]: Software calibration, returns offset voltage (not stored, used to compensate for temperature drift).

Calibration conditions: High precision DC calibration source (accuracy 0.1%), function generator (1 MHz, accuracy 0.002%) and other equipment should be used, operated by professional personnel.


Maintenance and troubleshooting

1. Daily maintenance

Cleaning: Regularly wipe the surface of the module with a dust-free cloth to remove dust; Stubborn stains can be wiped with diluted cleaning agents, and the use of abrasive cleaning agents is prohibited.

Fuse replacement: The module is equipped with+5V, -2V, ± 24V fuses (+5V uses Littelfuse 273005 2A fast melting type, others use 273002 2A fast melting type). After the fuse is blown, the fault needs to be eliminated before replacement.

Spare parts procurement: Ordering spare parts through Tektronix local offices or distributors requires providing product model, serial number, and revised version.

2. Common troubleshooting

Troubleshooting steps for possible causes of fault phenomena

SYSFAIL LED is always on. 1. Power failure (+5V/-2V/± 24V loss); 2. Self inspection failed; 3. CPU malfunction: 1. Check if the POWER LED is turned off. If it is off, replace the fuse; 2. Send the S command to perform extended self-test, and send the E command to read error codes; 3. Contact technical support for maintenance

No sampling data (MIP LED not lit) 1. Trigger condition not met; 2. Sampling frequency/period setting error; 3. Insufficient memory 1. Check trigger mode and threshold settings (M command); 2. Verify the sampling frequency command (F/P command); 3. Reduce the sample size of a single record or expand memory

Large deviation in analysis results: 1. uncalibrated or expired calibration; 2. Incorrect input parameter settings (range, coupling, impedance); 3. Insufficient sampling frequency (not satisfying Nyquist theorem) 1. Execute KS command to calibrate the corresponding voltage range; 2. Verify the parameters of the V command (ensure they match the signal); 3. Increase the sampling frequency (at least twice the highest frequency of the signal, recommended to be more than 10 times)

Communication failure: 1. Logical address setting conflict; 2. VXIbus bus failure; 3. Command format error: 1. Reset the logical address (to avoid conflicts with other modules); 2. Check the bus connection of the host rack; 3. Ensure that the command string conforms to syntax (ASCII characters, correct delimiter)

image.png

Extension options and compatibility

1. Extension options

Option 01:512K word sampling memory expansion.

Option 02: 1M word sampling memory expansion.

Option 2A (waveform output): Supports digital signal playback, programmable delay (200 ns to 420 s), output amplitude ± 1Vpp or ± 10Vpp (50 Ω load), and needs to be used in conjunction with a waveform output card.

2. Compatibility

Host rack compatibility: Supports all C/D size host racks that comply with VXIbus specifications, and Slot 0 requires a resource manager (such as VX4521).

Interface compatibility: Supports VXIbus serial protocol, compatible with IEEE-488 (GPIB) interface (requires conversion through Slot 0 module), configurable interrupt level (1-7 levels).

Software compatibility: Provides BASIC programming language sample programs and supports mainstream measurement and control software (must follow VXIbus instrument protocol commands).


Summary of Key Appendix Information

1. Appendix Core Content

Appendix A (VXIbus Operations): Detailed explanation of module VXIbus register definition, transfer mode (normal transfer/fast handshake), and interrupt handling process.

Appendix B (I/O Connections): Provide pin definitions, signal grounding requirements, and external trigger/clock/ARM signal interface specifications for BNC and DB25 connectors.

Appendix E (Fourier Transform): Explain the FFT principle, spectral leakage suppression (window function effect), and sampling frequency selection principle (Nyquist theorem).

Appendix H (Performance Verification): Provide the verification process and equipment requirements for key indicators such as DC accuracy, AC accuracy, and Common Mode Rejection Ratio (CMRR).

Appendix I (Calibration Process): Detailed description of the operation steps and adjustment of potentiometer positions for DC gain/offset calibration, AC gain calibration, and common mode rejection calibration.

2. Important Notice

Binary transmission: When using the National Instruments GPIB-VXI/C Slot 0 module, a dedicated code instrument (CI) needs to be loaded to avoid data buffer residue.

IEEE-488 address configuration: If the GPIB address is not assigned after the system is powered on, the Slot 0 resource manager delay (set to 5 seconds) needs to be adjusted to ensure that the module completes self-test.

image.png

  • GE WESDAC D20 C Combination Module
  • GE IC698CMX016 Control Memory Switch Module
  • GE SRPE60A 40 rated plug
  • GE 94-164136-001 motherboard control board
  • ABB PCD237A101 3BHE028915R0101 excitation control module
  • ABB XZC826A102 3BHE036348R0102 control module
  • ABB SAFT183VMC Safety Monitoring and Control Module
  • ABB LD 810HSE EX 3BSE091722R1 fieldbus link equipment
  • ABB RED615 HCDCACADAAHC2BNN11E Line Differential Protection and Control
  • ABB UFC760BE41 3BHE004573R0141 Industrial Computer Board
  • ABB 1TGE120011R2200 Motor Feed Control Unit
  • ABB PM865 3BSE030193R1 Compact Programmable Controller
  • ABB MVR 0.44-10KA high-power motor control module
  • ABB AO810 Input/Output Module
  • ABB SPAU341C1-AA RS488003-AA numerical protection repeater
  • ABB DSTA131 2668180-48/2 Programmable Logic Controller
  • ABB COM00012RAA005844A0004J2RAA005696N Control Panel Module
  • ABB MR7557891MRS050640C power relay
  • ABB 2RCA025057A0001R safety relay
  • ABB 2RCA013892A0003H power relay
  • ABB 2RCA013655A0001H power relay accessories
  • ABB 07KT94-98 controller
  • ABB 1MRK002247 Apr04 Transformer Module
  • ABB UNS0884a-v1 3BHE004385R0001 current sensor
  • ABB WMDOLT2-A75 (65KA) 6E 1TGE106812P0001 Input and Output Board
  • ABB Uras26 F-No. 3.346368.0 A-No 0240462201/2030 Gas Chamber Detector
  • ABB UFC911B101 3BHE037864R0101 control board
  • ABB TU841 3BSE020848R1 Termination unit for 1+1 TB840
  • ABB REF541KM115AAA relay feeder protection
  • ABB NINT-71C main circuit interface board
  • ABB LS14250 lithium battery
  • ABB ICSF08D1 FPR3323101R1012 24VDC high-speed counter
  • ABB DO814 Input/Output System
  • ABB 769111B gas chamber detector
  • ABB CM10/00MU1E0/STD Process Controller
  • ABB 769154 A filter element
  • ABB 769137 C 13CO2-10% 0746919 E detector
  • ABB 0769143 A Sample cell (Al), 175 mm
  • ABB 0002-07-2-000001-01 BMXS Scientific Module (ADC)
  • ABB CM15/000S0E0/STD Universal Process Indicator
  • ABB BSD0750 servo drive
  • ABB CI854BK01 Communication Interface Module
  • ABB XVC772A102 3BHE0322285R0102 circuit board
  • ABB AI04 Input/Output System
  • ABB TU847 module terminal unit
  • ABB TB807 module bus terminator
  • ABB PP877K control panel
  • ABB AO845A eA Analog Output Module
  • ABB SD822 power supply equipment
  • ABB 3BHB006716R0277 SYN5302A-Z.V277 synchronizer
  • ABB GFD233A103 3BH02294R0103 Controller
  • ABB 129740-002 134177-001 Intelligent I/O Module
  • ABB XUD194 3BHE018137R0001 AC800PEC High Performance Controller
  • ABB T3N225 Circuit Breaker
  • ABB A30-30-10RT three pole AC contactor
  • ABB SYN5302A-Z, V217 3BHB006716R0217 digital synchronizer
  • ABB NBIO-31 3BSE011337R1 I/O and Expansion Control Module
  • ABB 5SHX1960L0006 3BHB016120R0002 3BHE019719R0101 GVC736BE101 High Voltage Inverter Module
  • ABB PPC905AE101 3BHE014070R0101 control module
  • ABB REF615E_E HBFHAEAGNBA1BNN1XE digital feeder protection relay
  • ABB XVC770BE101 3BHE02103R0101 circuit board module
  • ABB 3BHL000986P7001 redundant DC power supply unit
  • ABB 3HAB8101-18/09A servo drive
  • ABB PM876-1 3BDH000707R1 Controller
  • ABB PPD117A3011 3BHE030410R3011 Excitation Controller Module
  • ABB 1MRK0023505-AA Transformer Differential Protection Relay
  • ABB PFSA140RULLM7A 3BSE006503R1 safety relay module
  • ABB PFSA140RULM1I 3BSE06503R1 drum power supply device
  • ABB MVME162-010A Embedded Controller Module
  • ABB 500BIM01 1MRB150024R0002 Digital Input Module
  • ABB 500BIM01 1MRB160024R0002 Digital Input Module
  • ABB 500PSM03 1MRB 150038 R1 894-030375D 136-011100H power module
  • ABB 500PSM02 1MRB150015R1 AD-272.100.20-01 AZ: C digital power module
  • ABB 500AIM02 1MRB150022 R0002 1HDF 930412 X010 Controller Module
  • ABB 500AIM02 1MRB150022 R0002Y 1HDF 930412 X010 Controller Module
  • ABB 500AIM02 1MRB150022R001 1HDF 930412 X010 Analog Input Module
  • ABB 500MTM02 1MRB150020R1102 1HDF 930512 X010 Controller Module
  • ABB 500MTM02 1MRK001967-AA 1HDF 930512 X010 Input/Output Module
  • ABB 500MTM02 1MRB150020R0712 1HDF 930512 X010 module
  • ABB 500BOM01 1MRB150023R0002 digital output module
  • ABB 500TRM02 1MRB150011R1 Terminal Relay Module
  • ABB 500TRM02 1MRB150011R0001 Transformer Monitoring Relay
  • ABB 500CPU03 1HDF700003R5122 Central Processing Unit
  • ABB 500PB101 1MRB178009R0001 1MRB200064/C Binary Input Module
  • ABB 500CSP04 HE401314/0002 1MRB150051R2 Input Module
  • ABB 500CMP04 HE401314/0001 1MRB150051R1 power module
  • ABB DSAO120 57120001-EY Digital Output Module
  • ABB SUE3000 1VCF750090R0804 servo drive module
  • ABB PFRL101C-1.0KN 3BSE023316R1002 radial weighing sensor
  • ABB UNS4684A-P, V.1 HIEE30514R00R00001 Communication Module
  • ABB PVD164A2059 3BHE014340R2059 excitation controller
  • ABB 3BHE046836R0102 GFD563A102 Analog I/O Module
  • ABB PFCL201CE 10KN 3BSX105983-100 Weighing Sensor
  • ABB PFCL201C 20KN 3BSE023409R20 Weighing Sensor
  • ABB 216VC62A HESG324442R112/F Signal Digital Processor
  • ABB 216EA61B HESG448230R1/G High Voltage DC Converter Valve
  • ABB 216AB61 HESG324013R101 digital output unit
  • ABB REF542 1VCR007346 G0028 Intelligent Sensor
  • ABB INSUMMCU2 MCU2A02V24 Intelligent Motor Control Unit
  • ABB MCU2A01C0-4 motor control unit
  • ABB PDP22-FBP fieldbus interface
  • ABB PNI800A Network Interface Module
  • ABB 3BHE039724R0C3D PPD513AOC 100440 Controller
  • ABB SDCS-CON-2-COAAT 3ADT220090R2 Controller
  • ABB CI543 communication interface
  • ABB PM510V08 3BSE00B373R1 processor module
  • ABB UNITRAL1010 3BHE035301R0001 UNS0121A-Z-V1 Exciter
  • ABB CI873K01 3BSE058899R1 Ethernet/IP interface module
  • ABB DYTP600A 61430001-ZY Signal Processor Module
  • ABB REF615C-E HCFFAEAGAABC2BAA11E feeder protection and control
  • ABB PCD235C101 3BHE057901R0101 Expansion Adapter
  • ABB UAD149A0001 3BHE014135R0001 excitation controller
  • ABB UAD149A1501 3BHE014135R1501 Controller Module
  • ABB REF545KC133AAAA protective relay
  • ABB PFSA103D 3BSE002492R0001 intermediate relay
  • ABB KUC321AE HIEE300698R1 power module
  • ABB PFVK135 PLC signal processing board
  • HIMA X-CPU 01 processor module
  • ABB TU811 Compact Module Terminal Unit
  • ABB REM610C55HCNN02 motor protection relay
  • ABB IMRIO02 Remote Input/Output Module
  • ABB PFEA113-20 3BSE050092R0 Tension Electronic Equipment
  • ABB UFC911B108 3BHE037864R0108 communication interface
  • ABB REU615E_D Voltage Protection and Control Relay
  • ABB PPD512A10-150000 Controller
  • ABB 5SHX1445H0001 3BHL0000391P0101 3BHB003230R0101 5SXE05-0152 module
  • ABB ICST08A9 Modular Controller
  • ABB 1SVR011718R2500 Analog Converter