Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

Eaton XV-303/XV-313 multi touch display

F: | Au:FAN | DA:2025-07-09 | 442 Br: | 🔊 点击朗读正文 ❚❚ ▶ | Share:

Eaton XV-303/XV-313 multi touch display

Basic Information

Document information: Released in March 2025, version 01.1, copyright belongs to Eaton Corporation. Reproduction, dissemination, etc. are not allowed without permission.

Equipment Overview

Function: It can be used as an operation and monitoring device, or as an operation and control device with PLC function. It adopts industrial high-resolution capacitive multi touch technology, has an intuitive gesture based user interface, and a powerful graphics processing unit.

Model difference: XV-303 is a front mounted type, while XV-313 is a rear (panel) mounted type.

Display size: There are three widescreen sizes: 7.0 inches, 10.1 inches, and 15.6 inches, with resolutions of 1024x600 pixels and 1366x768 pixels, respectively.

Processor and Memory: Equipped with an 800MHz ARM Cortex-A9 processor, 1GB of internal memory and 128kB of non-volatile data storage, the memory can be expanded through an SD card.

Operating system: Linux operating system is used.

Safety regulations

Personnel qualifications: Installation, operation, maintenance, and repair personnel must possess corresponding qualifications, undergo appropriate training, and understand the hazards and risks related to the equipment.

Precautions before installation: Installation must be carried out by a qualified electrician. Before installation, disconnect the equipment power supply to prevent re triggering, verify isolation from the power supply, grounding and short circuit, cover adjacent live parts, etc.

Equipment specific hazards and prevention

There is a risk of explosion, and it can only be used in non hazardous areas and hazardous areas defined by the ATEX directive in Zone 22 to avoid dangerous impacts.

Improper handling of lithium batteries may cause explosions, and professional equipment disposal is required.

Static discharge may damage components, and static electricity should be released before contacting the equipment.

Non galactic isolated interfaces may damage equipment due to potential differences, and power must be disconnected before connecting and disconnecting connectors.


Installation

Installation location requirements

The environmental temperature, air pressure, humidity, etc. must comply with regulations and avoid direct sunlight and heat sources.

The installation location should ensure that the device controls and connectors are accessible, taking into account the space required for removing the SD card.

There are specific requirements for the installation angle and panel thickness of different models.

Installation steps

Unpack and inspect the equipment for any transportation damage, and verify the contents of the packaging.

The front installation type and the rear installation type have different fixing and sealing methods and steps.

Preparation for operation: Connect the grounding function and pay attention to the specifications of the grounding wire; Connect the power supply by an electrician, paying attention to voltage polarity and requirements.


Debugging

Initial debugging: Configure system settings and install required software packages.

Operation: After connecting to the power supply, the device will start without the need for a separate switch. Lowering the brightness can extend the lifespan of the monitor backlight. In case of any malfunctions, please refer to the troubleshooting section.


External connection

Interface types: including SD card slots, USB host and device interfaces, Ethernet interfaces, RS-232, RS-485, CAN1 interfaces, etc. Different interfaces have corresponding specifications and connection requirements.

Connection precautions: Avoid stray currents, use appropriate cables and correctly assemble terminations, follow relevant standards and instructions.


Troubleshooting

Listed the reasons and solutions for common malfunctions such as device failure to start, monitor dimming, unresponsive or incorrectly responsive touch technology.


Maintenance

Cleaning and maintenance: The equipment is basically maintenance free. When the touch technology gets dirty, it can be cleaned with a clean, soft, and damp cloth, and recalibrated if necessary.

Maintenance: Maintenance requires contacting the supplier or Eaton technical support, and the equipment can only be opened by the manufacturer or authorized center.

Storage, transportation, and disposal: Storage and transportation must comply with environmental conditions, avoid UV light and condensation water, and equipment scrapping must be professionally disposed of, following local recycling regulations.

  • SIGMATEK ET3200 Display Screen
  • SIGMATEK CEZ221 C-DIAS Mixing Module
  • SIGMATEK SDD120-2 DIAS Servo Drive
  • SIGMATEK DIP011 05-058-011 Module
  • Sigmatek DEC181 I/O Module
  • SIGMATEK DCP640 DIAS Central Unit
  • SIGMATEK 00-450-024 C-IPC Industrial Computer
  • SIGMATEK AKM32C-ANCNR-B0 Servomotor
  • SIGMATEK DVI021 DIAS Power Module
  • SIGMATEK CTS051 12-053-051 Control Module
  • SIGMATEK CTS022 Control Module
  • Sigmatek 01-250-010-D NC4Kompakt V2.1 Module
  • SIGMATEK Control Keyboard 01-285-042 Interface
  • SIGMATEK TO081 20-007-081 Digital Output Module
  • Sigmatek AKM73Q-ANCNGBB0 7.07kW Servo Motor
  • Sigmatek DIP012 Demag 07024165 Processor Module
  • SIGMATEK PC 411 Injection Molding Controller
  • SIGMATEK CEZ201 12-051-201-O Processor Module
  • SIGMATEK VI021 20-003-021 Digital Input Module
  • SIGMATEK Computer C-IPC 144904 Industrial PC
  • SIGMATEK 9307.083.01 9305.081.02 Industrial Module
  • SIGMATEK AI075 Analog Input Module
  • SIGMATEK HGT834-W Teaching Pendant
  • Sigmatek CDI161 Digital Input Module
  • SIGMATEK HGT834 Teaching Pendant
  • SIGMATEK CEZ201 12-051-201-O Module
  • SIGMATEK Demag 9617.067.03 9708.244.00 Module
  • SIGMATEK SCP010 Safety CPU Module
  • SIGMATEK N100 20-011-100 Module
  • SIGMATEK CNC 031 Positioning Output Module
  • Sigmatek 01-355-016 Control Module
  • Sigmatek MDM021 Digital Mixed Module
  • Sigmatek DAI411 05-020-411 Analog Module
  • Attitude Gyro 1U367-232-2 Aircraft Instrument
  • Sigma-Tek 5000B-36 Attitude Gyro 23-501-06-16
  • Sigmatek HGT834-W Injection Molding Teach Pendant
  • Sigma Tek 5000EG Attitude Gyro 1U670-003-12
  • Sigmatek HGT834-W Teach Pendant
  • Sigmatek DEE011 05-068-011 Module
  • Sigmatek DIAS DCP643 Central Processing Unit
  • Sigmatek MDD111-1 DIAS Drive Axis Module
  • Sigmatek DKL042 05-024-042 Terminal Module
  • Sigmatek DM822 Control Module
  • Sigmatek CDM167 12-008-167-O Module
  • Sigmatek TAE151 Touch Display Unit
  • Sigmatek DCC041 SLIDES Module 05-700-041-D
  • Sigmatek AKM65M-ANC2GBB0 PM Servo Motor
  • Sigmatek ETT221 01-230-221 Operator Terminal
  • Sigmatek SLIDES DAM 124 Analog Module
  • Sigmatek AKM31C-ANCNGBB0 Servo Motor
  • Mannesmann Demag Sigmatek CP626 Central Unit
  • SIGMATEK 0332.554.03 Board 371071000154
  • SIGMATEK 12-250-021 Base Plate Back Panel CM5V020
  • SIGMATEK DM162 S-DIAS Digital Mix Module
  • DEMAG ERGOTECH 061 381 66 Sigmatek 9842.243.02 Circuit Board
  • SIGMATEK CP313-1 PLC Module
  • Sigmatek ETV0551-2 VARAN Touch Terminal
  • Sigmatek SDM 081 FS S-Dias Safety Module
  • DEMAG 05-250-023 Ergotech Motherboard with Sigmatek TMS012
  • Sigmatek CM5V020 12-250-023-K Wiring Base
  • Sigma Tek 5000B-37 Attitude Gyro Indicator
  • Sigmatek SDD120-2 DIAS Drive
  • Sigmatek CME221 Memory Module
  • Sigmatek DCP640 DIAS Central Unit
  • Sigmatek STO040 Safety Output Module
  • Sigmatek CET281 Control Panel
  • Sigmatek CIPC LX800 Demag NC5 CPU
  • Sigmatek DKL093 05-024-093 Terminal Module
  • Sigmatek AI088 20-009-088 Analog Input Module
  • Sigmatek CAI888 Analog Input Module
  • SIGMATEK CCA021 12-025-021 Analog Output Module
  • SIGMATEK 1104.579.05 Control Module
  • SIGMATEK SDI100 Digital Input Module
  • SIGMATEK C-IPC 256MB LX800 Compact Dias
  • SIGMATEK 9423.090.02 Control Module
  • SIGMATEK C-IPC 256 Power Supply 148498
  • SIGMATEK CAI025 Analog Input Module
  • SIGMATEK CTO166 Digital Output Module
  • SIGMATEK CP112 20-004-112 Processor Module
  • SIGMATEK CAI887 12-009-887 Safety Module
  • Sigma-Tek 4000B-31 Directional Gyro 1U262-002-42
  • Sigmatek C-IPC 256MB LX800 IPC Controller
  • Sigmatek C-IPC 01-450-031 Industrial PC LX800
  • Sigmatek C-IPC 256 Industrial PC Controller
  • Sigmatek CCP-531 PLC Processor Module
  • Sigmatek CDI163 Digital Input Module
  • Sigmatek ETV0501 VARAN Terminal 12-230-0501
  • Sigmatek CTMS020 C-DIAS Technology Module
  • Sigmatek CIV512 VARAN Switch Module
  • Sigmatek HU011 20-080-011 Interface Module
  • SIGMATEK SLIDES DAM 124 Module
  • SIGMATEK C-IPC 161 01-450-161L Industrial PC
  • SIGMATEK C-IPC 128MB VIA 733MHz 01-450-024-K
  • SIGMATEK 12-780-012 R8-IPC Geode LX800 Module
  • SIGMATEK CAM124 Analog Module
  • SIGMATEK S1 032-8AF61-R4 EZ Servo Motor
  • SIGMATEK CTO163 Digital Output Module
  • SIGMATEK CCP082 12-004-082 Processor Module
  • SIGMATEK CRCH081 C-DIAS Temperature Module
  • SIGMATEK PC322-K 01-310-322-K Industrial PC
  • SIGMATEK SDD310-2 Servo Drive
  • SIGMATEK AI084 Analog Input Module
  • SIGMATEK CRCH081 12-752-081 Temperature Module
  • Sigma-Tek 5000L-4 Attitude Gyro 1U284-001-3
  • SIGMATEK CM5V020 12-250-023-K Wiring Module
  • Sigma-Tek 4000H-6 Directional Gyro IU262-035-7
  • SIGMATEK Dias DCP160 05-004-160 Processor Module
  • SIGMATEK 0147.395.02 Control Module
  • SIGMATEK A1084 Control Module
  • SIGMATEK DI200 20-006-2000 Digital Input Module
  • Sigmatek DNC115 Encoder Module
  • Sigmatek DAM122 05-017-122 Analog Module
  • Sigmatek 9802.289.01 Control Board TA71 Display
  • Sigmatek TO127 20-007-127 Digital Output Module
  • Sigmatek DNC031 05-011-031 Digital Module
  • Sigmatek VI022 20-003-022 Interface Module
  • Sigmatek CAI085 Analog Input Module
  • Sigmatek CP111 S-DIAS CPU Module
  • Sigmatek CTMS030 Krauss Maffei Module
  • Sigmatek CAM123 Control Module
  • Sigmatek TAE732-P 01-240-732-P Touch Display Unit
  • Sigmatek MDM021 Digital Mixed Module
  • Sigmatek DCP642 DIAS Central Unit
  • Sigmatek CST022 12-014-022 C-DIAS Module
  • Sigmatek SRO021 20-893-021 Safety Relay Output
  • Krauss Maffei MC5 Control System Sigmatek
  • Sigmatek DC061 Module 18-24VDC 300mA
  • Herrmann EVT0855 Ultrasonic Welder Touch Panel