Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

Eaton XVH300 MICRO PANEL

来源: | 作者:FAN | 发布时间 :2025-07-09 | 445 次浏览: | 🔊 Click to read aloud ❚❚ | Share:

Eaton XVH300 MICRO PANEL

Basic Information

Document information: Released in November 2014, replacing version M001506. The German version is the original description, and other language versions are translated versions. The copyright belongs to Eaton Automation Co., Ltd. Reproduction and dissemination are prohibited without permission.

Equipment Overview

Name: XVH300 and MH2 are different names for the same product.

Function: As an HMI device, it is mainly used in mechanical and system manufacturing, specifically for visualization and operation of machines and systems. Other uses require prior consultation with the manufacturer.

Version: Divided into multiple versions based on touch type (resistive, infrared) and interface (no fieldbus, CAN, Profibus, Suconet K, RS232, etc.), such as XVH-330-57BAS, XVH-340-57CAN, etc.

Packaging content: Includes MICRO PANEL host, fixed bracket with threaded pins for installing equipment, installation sealing strip, power connector, etc., and accessories such as handwriting pens can also be ordered.

Safety regulations

Symbol meaning: Different symbols are used according to the degree of danger, such as "DANGER" indicating extreme danger that may result in death or serious injury; Warning "indicates potential danger that may result in death or serious injury.

Personnel requirements: Installation, operation, maintenance, and service personnel must have sufficient qualifications, undergo training, and understand the hazards and risks related to the equipment.

Prohibited use: The use of this device for safety purposes (related to personnel and machine protection) is prohibited.

Equipment related hazards and prevention

There is a risk of explosion, and specific requirements must be followed when operating in potentially explosive environments, such as avoiding dangerous impacts, disconnecting plug connections after power failure, etc.

There are live parts inside the equipment. It is forbidden to open the equipment to prevent electric shock.

The protective grounding system between different devices may generate large balanced currents, and equipotential bonding conductors need to be installed if necessary.

Static discharge may damage electronic components, so it is necessary to release body static electricity before coming into contact with the equipment.

Resistive touch surfaces are sensitive, avoid touching with sharp objects, and ensure gloves are clean when operating.


Operation and indication components

Front: There is a touch sensor (detecting the triggering of operating elements on the display screen) and a display screen (displaying operating and indicating elements).

Service side: There are operating components such as CF card slot cover, CF slot, eject button, control button, as well as indicator components such as CF ACT, CAN ACT/PROFIBUS ACT. Different indicator lights have different meanings, such as CF ACT light on indicating that the CF card is being accessed.

On the connector side of the SKS device, there are indicator lights such as "COM PORT ERROR" and "COM PORT ACT", as well as a "LINE TERM. COM PORT" switch, which are used to indicate data transmission errors, data transmission activity, and control the terminal resistance of the RS485 interface.


Installation

Installation location requirements: It needs to be installed in an approved location, and the power supply must meet the requirements. Considering the engineering acceptance conditions of UL certification, the installation location should avoid direct sunlight, ensure that the operating components and cable connections on the service side of the equipment are accessible, meet environmental conditions and ventilation requirements, and the installation surface must meet specific thickness, flatness, and roughness requirements.

Interface: Different versions of devices have different interfaces, including Ethernet, CAN, Profibus, RS232, RS485, USB device interfaces, power interfaces, etc. Each interface has corresponding wiring requirements and specifications.

Installation steps: Check for equipment transportation damage, prepare installation cuts in control cabinets and other locations, install sealing strips, place the equipment into the installation cut from the front, fix it with fixed brackets, etc. Pay attention to relevant safety regulations during installation.


Operation

Safety regulations: Before operation, it is necessary to read the safety regulations section and pay attention to protecting the resistive touch surface to avoid turning on the device when condensation occurs due to climate change.

Start the device: Insert a CF card with an operating system, turn on the power, and the device will start. After initial debugging, adjust the system settings and install the required applications.

Turn off the device: Disconnect the power of the device. Before turning off, make sure that no software is writing to the CF card to avoid frequent device switching to extend the backlight life.


Maintenance and Service

Safety regulations: Before maintenance, it is necessary to read the safety regulations chapter.

Maintenance work: Resistive touch devices are basically maintenance free, and can be cleaned or recalibrated if necessary; Infrared touch devices require regular cleaning of the infrared frame and do not require recalibration.

  • ABB DSAI130DK01 3BSE020828R1 Analog Input Module
  • Parker 466966-0001-3820 Industrial Component Data
  • PARKER ZETA6104 Microstepping System
  • PARKER COMPAX 2500S/F3 Servo Drive Manual Details
  • PARKER CX-DH Indexer Drive Technical Specifications
  • PARKER 6K8 Motion Controller Features and Specifications
  • PARKER EVM32-BASE I/O Module Base Technical Specification
  • ABB Pb PN-112718 Digital Input Module
  • Pb PN-45734 PN-73899 Industrial Automation Module
  • Control Techniques Pb PN-40856 Industrial Control Module
  • Pb PN-104412 4002910956 Industrial Control Module
  • Siemens Pb PN-41513 Industrial Ethernet Module
  • Pelco PA30-0065-00-A1 PTZ Decoder Module
  • Pentek FILTER 3F11 800000919 Pleated Filter Cartridge
  • Pepperl+Fuchs RSD-TI-EX8 Temperature Input Module
  • PERITEK AC7-00712-1113 Industrial Interface Module
  • PFEIFFER EVR116 Vacuum Control Module
  • Pepperl+Fuchs RSD-CI-EX8 Hazardous Area Interface Module
  • PEPPERL+FUCHS 2108HAT Intrinsic Safety Barrier Module
  • Philips 958481320201 PROC+ Processing Unit
  • Philips 958481321300 PSB Power Supply Board
  • Philips 958481321220 PD208 Power Module
  • PHILIPS 958481321200 PD216 Control Module
  • PHILIPS 958481320201 PROC PLUS Control Module
  • Philips 958481320400 PIF Interface Module
  • Philips 958481320100 LCB Control Board
  • PHILIPS 958481223220 Industrial Control Module
  • PHILIPS 958481223223 Industrial Control Module
  • PHILIPS 958481321300 Industrial Control Module
  • PHILIPS SCM040 Digital Output Synchronization Module
  • PHILIPS DSI020 Data Storage Interface Module
  • PHILIPS OPM010 Optoelectronic Control Module
  • PHILIPS VBM010 Industrial Automation Module
  • PHILIPS VBM030 Turbine Supervisory Instrumentation
  • PHILIPS PR1613 Industrial Control Module
  • PHOENIX PATG1/23 1013847 Ground Terminal Block
  • Phoenix Contact IB ST 24 AI 4/SF Analog Input
  • Phoenix Contact OPC5315-004-AB Industrial PC
  • Phoenix Contact UMK-SE11.25-1 Side Element
  • PHOENIX 2961192 Relay Module
  • PHOENIX IB ST ZF 24 AI 4/SF Analog Input Module
  • Phoenix Contact PLC-BSC-24DC/21 Relay Base
  • Phoenix Contact UK6N Feed-Through Terminal Block
  • Phoenix Contact UK4-T Disconnect Terminal Block
  • Phoenix UK3N Screw Terminal Block
  • Phoenix QUINT-PS-100-240AC/10 Power Supply
  • Phoenix QUINT PS-100-240AC/24DC/10 Power Supply
  • Phoenix UT 6-HE SI Surge Protection Terminal Block
  • Phoenix UT 4-MTD Feed-through Terminal Block
  • Phoenix UT 4-HE SI Surge Protection Terminal Block
  • Phoenix IBS 24BK-I/O-T Bus Coupler
  • Phoenix Contact HDFK4 High-Current Terminal Block
  • PHOENIX ST-SI-UK4 Fuse Terminal Block
  • PHOENIX FLMC10BASE-T/FO G850 Fiber Media Converter
  • PHOENIX CONTACT QUINT-PS-100-240AC/24DC/40 Power Supply
  • PHOENIX CONTACT QUINT-DIODE/40 Redundancy Module
  • Phoenix Contact 2884208 Wireless I/O MUX
  • Photonetics 3646 HE 1540 Tunable Laser Source
  • PI C-663.12 Mercury Multi-Axis Step Motor Controller
  • PI C-663.10 Mercury Step Motor Controller
  • Pillar CB6687-2L Industrial Communication Board
  • Pilz DE-106712 A.F.051.5/01 Safety Module
  • Pilz 680003 Safety Relay Module Set
  • Pilz 301140 PNOZ X3 Safety Relay
  • Pilz P1U-1NB Safety Relay
  • Pioneer PM3398B-6-1-3-E Power Supply
  • Pioneer Magnetics PM3326B-6-1-2-E Power Supply
  • Pioneer Magnetics HYRSP-1500-56 Power Supply
  • Pioneer Magnetics PM3398B-6-1-3-E Power Supply
  • Pioneer Magnetics PM3328BP-6 Power Supply
  • Potter & Brumfield SDAS-01-7Y2S1024 Relay
  • Powec PMP10.48 SIC High-Efficiency Rectifier
  • Powerbox PU200-31C Industrial DC-DC Converter
  • PIONEER MAGNETICS PM3398BP-6-1-3-E Power Supply Module
  • PIONEER MAGNETICS PM1253AL-6-3-Z03 Power Supply Module
  • Powerex PD411811 Rectifier Diode Module
  • Power-One MAP55-1024 AC-DC Power Supply
  • ProSoft MVI56-MDA4 ControlLogix Multi-Protocol
  • POLYSPED PRD2-200 Industrial Drive Module
  • P-OPEN P-OPEN-P4-150 PAC-OP150 Operator Panel
  • ABB Processor 958481321210 350211080320 Rugged CPU
  • ABB Processor 958481320201 350211080460 Safety CPU
  • ABB Processor 958481321200 350211080320 CPU Module
  • ABB Processor 958481321220 350211080320 CPU Module
  • ABB Processor 958481320100 350211080090 CPU Module
  • Pro-Face PL5901-T42-24V HMI Touch Panel
  • PROFIBUS PB3-VME-1-E V1.2.2 Interface Card
  • PROMESS 850040060P Force Displacement Monitor
  • PROSOFT AN-X2-AB-DHRIO DH+ and Remote I/O Gateway
  • PROSOFT RLX2-IFH24E Industrial Wireless Radio Module
  • PROSOFT 5202-DFNT-MCM4 DF1 to EtherNet/IP Gateway
  • PROSOFT PLX35-NB2 EtherNet/IP to Modbus TCP Gateway
  • ProSoft 5201-MNET-MCM-WEB Modbus TCP/Serial Gateway
  • ProSoft 5304-MBP-PDPMV1 Modbus Plus to PROFIBUS DP Master
  • ProSoft 5302-MBP-MCM4 Modbus Plus to Modbus Master/Slave
  • ProSoft 5301-MBP-DH485 Modbus Plus to DH485 Gateway
  • ProSoft 6104-WA-PDPM Wireless PROFIBUS DP Master
  • ProSoft MVI56-LTQ ControlLogix Limitorque Master
  • Prosoft 5304-MBP-PDPM PROFIBUS Master Module
  • Prosoft 1452-25M Relay Output Module
  • Prosoft MVI56-MNETR Modbus TCP/IP Module
  • Prosoft MVI69L-MBS Modbus Serial Module
  • Prosoft PLX32-EIP-SIE Ethernet Gateway
  • Prosoft MVI56-PDPS PROFIBUS DP Slave Module
  • Prosoft PMF1327205 Gateway Module
  • Prosoft PMF1216D61 FOUNDATION Fieldbus Module
  • PROSOFT MVI56-GSC Generic Serial Communication Module
  • PROSOFT 5601-RIO-MCM Remote I/O Communication Module
  • PROSOFT 1454-9F Communication Interface Module
  • PROTECH SYSTEMS PBI-6SA Industrial Single Board Computer
  • PRSTECH DMP10.24-20 DIN-Rail Power Supply
  • PRT PSA300R-81 Industrial Power Supply Module
  • PULS SLA8.100 AS-Interface Power Supply
  • QSI QTERM-K65 Industrial Operator Interface
  • R-2528Z R-2528Z Industrial Specialized Component
  • Radisys SBC486DX66 Single Board Computer
  • Radisys EPC-5 with EXM-13 Embedded System
  • Radisys EPC-16 Embedded Computer
  • Ramix PMC676TX PMC Ethernet Adapter
  • Ramix PMC008A PMC-to-VME Adapter
  • Ramix PMC237C-008EMI PMC Carrier
  • Ramix PMC661J PMC Carrier Board
  • Renata CR2450N Lithium Battery
  • Renault Circuit CU-8593-IND.A Control Module
  • Reotron 567LH-DP24 Voltage Regulator
  • RIFA IC693PWR321U GE Fanuc Series 90-30 Power Supply
  • RKC REX-B871NN-CS1B Intelligent Controller
  • RKC B871-RCU Digital Temperature Control Unit