5. Special operation: Parallel operation
Only compatible Westinghouse inverter generators can be connected in parallel, requiring the use of dedicated parallel cables (such as 507PC model).
Operation steps:
Both generators have turned off the fuel switch and ECO mode.
Connect the parallel interface of two generators using parallel cables.
Start one generator first, wait for the output ready light to turn on, and then start another one.
Gradually connect the load, with the total load not exceeding the sum of the power of the two generators.
Attention: Do not enable ECO mode during parallel operation to avoid voltage instability during high load startup.
6. High altitude operations (>2000 feet/762 meters)
High altitude carburetor kit (part number 518913-01) needs to be installed, otherwise it will result in decreased performance and increased fuel consumption.
For every 1000 feet increase in altitude, the power decreases by about 3.5%, and the load needs to be adjusted according to the actual altitude.
Do not use high-altitude kits at low altitudes (<2000 feet) to avoid damaging the engine.