AB 1771-OFE Series B Analogue Output Modules

来源: | 作者:FAN | 发布时间 :2025-04-21 | 648 次浏览: | Share:

AB 1771-OFE Series B Analogue Output Modules

Module Overview:

Functionality: The 1771- OFE is an intelligent block transfer module that converts binary or quadruple BCD values supplied 

by the processor into analogue signal outputs. It has four independently isolated differential output channels with selectable scaling, data format, etc. 

It requires no external power supply and occupies only one I/O slot.


Output range: There are three versions, 1771-OFE1 is a voltage output, 1 - 5V dc, 0 - 10V dc, +10V dc can be selected through the configuration jumper; 

1771-OFE2 and 1771-OFE3 are current outputs, 4 - 20mA and 0 - 50mA respectively, and the latter two are factory-set.

Communication mode: The processor transmits data to and from the module through the BTW and 

BTR instructions in the ladder program to send output values, set modes and receive status information.


Installation steps:

Preparation for installation: Comply with the relevant EU directives, calculate the power requirement before installation 

to avoid overloading the backplane and power supply of the I/O chassis.

Module Setup: Can be installed in any slot of the I/O chassis, but avoid grouping with discrete high-density modules, 

and keep away from AC or high-voltage DC modules. Set configuration jumpers, including the 

last state configuration jumper (determines the output state in the event of a communication failure) and the voltage range configuration jumper (for 1771-OFE1)

Installation and Connections: Install the keying strip, insert the module smoothly into the chassis and secure it, and connect the 1771-WH junction arm; 

use the 1771-WC junction arm to connect to analogue equipment with the sensor cable shielded and grounded at the chassis end only.


The module is configured:

Configuration: Configure the module using a Block Transfer Write command (BTW) with a 13-word maximum 

write block containing output data, data format, and scaling information.

Data format and scaling: data format can be BCD or binary, scaling function can convert data to engineering units, 

by setting the corresponding scaling value, the maximum scaling value is 9999, the minimum is - 9999, and the maximum must be greater than the minimum.

Default Configuration: At power-on, the module microprocessor defaults to positive data words, no scaling, and BCD data format.


Programming Points:

Programming Format: The programming format is different for different processors, PLC-2, PLC-3, PLC-5 have their own characteristics, 

and the module does not allow the enable bit of the read/write instruction to be set to ON at the same time.

Programming Considerations: Including block length and scaling considerations (e.g., different settings for no-channel scaling, partial-channel scaling, 

and full-channel scaling), block transfer boundary words (PLC-2 processor), 

and module update time (8 milliseconds for BCD and scaling, and 1.6 milliseconds for binary and no scaling).


Performance

Optimisation of hardware mounting and layout: Choose the location of the modules in the I/O chassis appropriately, 

avoiding the grouping of discrete high-density modules, and keeping them away from AC or high-voltage DC modules in order 

to reduce electromagnetic interference. 

Modules that are too close to these sources of interference may result in unstable signal transmission and affect the accuracy of 

the analogue output. Installing the module in a location away from the source of interference with 

good shielding and grounding can effectively reduce the impact of electromagnetic interference 

on the performance of the module and improve the quality of signal transmission . 

Ensure that the sensor cable is properly connected and well shielded, and the cable shield is grounded only at the chassis end to reduce noise interference. 

If the shield is not properly grounded or shielded cable is not used, external noise may be coupled into the signal line, 

resulting in fluctuations or errors in the output signal. 


The use of high quality shielded cables, such as Belden 8761, and grounding in strict accordance with the specifications, 

can enhance the module's anti-interference ability and ensure the stability of the output signal.

Fine adjustment of parameter configuration: According to the actual application requirements, precisely set the output range and data format of the module. 

Different analogue devices have different requirements for input signals, and the correct choice of output range 

and data format can ensure the compatibility of the module with the device and improve the output accuracy. 

For devices requiring 0 - 10V voltage input, setting the output range of the 1771-OFE1 module to 0 - 10V and selecting the appropriate data 

format (e.g., binary or BCD) can match the output of the module with the requirements of the device, 

avoiding data conversion errors caused by incompatible formats. 


Reasonable use of the scaling function to convert data to actual engineering units can improve the readability and practicality of the data. 

  • SIEMENS 6ES5377-0AB41 SIMATIC S5 Digital Output Module
  • SIEMENS 6ES5375-1LR41 SIMATIC S5 Interface Module
  • SIEMENS 6ES5318-8MA12 SIMATIC S5 Interface Module
  • SIEMENS 6EC1710-OA System Interface Module
  • SIEMENS 6EC1001-0A Industrial Control Module
  • SIEMENS 6EC1661-0A Power Supply Module
  • SIEMENS 6DS1731-8RR Communication Processor
  • SIEMENS 6DS1731-8DC SIMADYN D Control Module
  • SIEMENS 6DS1723-8BA TELEPERM M Bus Coupling Module
  • SIEMENS 6DS1722-8BA Communication Module
  • SIEMENS 6DS1717-8CC TELEPERM M Interface Module
  • SIEMENS 6DS1703-8AB SIMADYN D Control Module
  • SIEMENS 6DS1618-8CA Communication Module
  • SIEMENS 6DS1601-8BA SIMADYN D Control Module
  • SIEMENS 6DS1603-8BA TELEPERM M Analog Output Module
  • SIEMENS 6DS1412-8DD Communication Processor
  • SIEMENS 6DS1315-8AC TELEPERM M Input/Output Module
  • SIEMENS 6DS1322-8BA SIMADYN D Control Module
  • SIEMENS 6DS1311-8AE Communication Interface Module
  • SIEMENS 6DS1213-8AA SIMADYN D Control Module
  • SIEMENS 6DS1212-8AB TELEPERM M Terminal Module
  • SIEMENS 6DS1206-8AA Communication Module
  • SIEMENS 6DS1200-8AB Control Module
  • SIEMENS 6DR2001-1 SIPART DR20 Digital Controller
  • SIEMENS 6DD2920-0AB0 Automation System Module
  • SIEMENS 6DD1683-0CD0 Drive Control Module
  • SIEMENS 6DD1683-0CC0 SIMADYN D Interface Module
  • SIEMENS 6DD1682-0CH0 Control System Module
  • Siemens 6DD1681-0CA2 SIMADYN D Interface
  • SIEMENS 6DD1682-0BC3 Drive Control Module
  • Siemens CSH11 6DD1661-0AB1 Industrial Ethernet Communication Module
  • SIEMENS 6DD1610-0AH0 System Interface Module
  • SIEMENS 6DD1606-0AD0 System Module
  • SIEMENS 6DD1602-0AE0 Drive Control Module
  • Siemens 6AV6545-0BC15-2AX0 TP170B Touch Panel
  • SIEMENS 545-1105 Industrial Control Module
  • Siemens 505-7339 RTD Input Module
  • SIEMENS 505-6660B PLC Control Module
  • SIEMENS 505-6660 System Component Module
  • Siemens 462.000.7076.00 Control Card
  • SIEMENS 505-6108B PLC Control Module
  • SIEMENS 3TH2031-0HY4 Contactor Relay
  • SIEMENS 3HAB8278-1 Industrial Control Module
  • Siemens 3TF3200-OB-Z Power Contactor
  • SIEMENS 39SDM024DCCBN Drive Module
  • SIEMENS 1FT6064-1AF71-3AG1 Servo Motor
  • SIEMENS 39ACM24BEN Control Module
  • SIEMENS 1FK6084-6AZ21-9ZZ9-Z-S29 Servo Motor
  • Siemens 1FK6084-6AZ21-9ZZ9-Z S05 Servomotor
  • SIEMENS 1FK6063-6AF71-1EH0 Servo Motor
  • SIEMENS 16137-118 Control System Module
  • SIEMENS 6ES7322-1BH01-0AA0 Digital Output Module
  • Siemens 3AY1715-6L VS30041 Control Module Guide
  • SIEMENS 6ES7321-1BH02-0AA0 Digital Input Module
  • TEKTRONIX 5B42 Dual Trace Amplifier Plug-in
  • TEKTRONIX 5A18N Dual Trace Amplifier
  • TEKTRONIX VX4240 High-Speed Digitizer Module
  • TEKTRONIX 5B40 Dual Channel Amplifier Plug-in
  • TEKTRONIX 5A48 Dual Trace Amplifier Plug-In
  • TEKTRONIX 5B12N Time Base Module
  • TEKTRONIX 5A38 Differential Amplifier Plug-in Module for 7000 Series Oscilloscopes
  • TEKTRONIX 5A22N Differential Amplifier
  • TEKTRONIX 5440 Oscilloscope
  • TOSHIBA ANALD AFX-90L-RH Analog Module
  • TOSHIBA HC422B 7862 System Module | 2N3B2895-C5, N-300, 2J3B2895-C2 Components
  • TOSHIBA 2N3A3620-B Controller Module
  • TOSHIBA 2N3A8130-A Control Module
  • TOSHIBA 2N3A3120-D Control Module
  • TOSHIBA HC422B High-Speed Counter Module
  • TOSHIBA TBU31A Interface Module
  • TOSHIBA SN321 PLC System Module
  • TOSHIBA MC392 Control Module
  • TOSHIBA JEC-2137-20003 Controller Module
  • TOSHIBA EX2040PRGD Expansion Module
  • TOSHIBA DO334 Digital Output Module
  • TOSHIBA DI335H Digital Input Module
  • TOSHIBA 2J3K2313-C Drive Control Module | DIT-543, NAS-433A System Component
  • TRICONEX 9860-610 External Termination Panel
  • TRICONEX 9562-810 16-Point Common End Digital Input Terminal Board
  • TRICON 9001NJ Power Supply Module
  • Triconex 8405N Digital Output Module
  • TRICONEX 4000093-310 Input Termination Cable Set
  • Triconex 8105N Digital Input Module
  • TRICONEX 4107 Communication Module
  • TRICONEX 4000164-520 High-Density Digital Input Module
  • TRICONEX 4000163-510 Industrial Control Module
  • TRICONEX 4000103-510 External Termination Cable
  • TRICONEX 4000056-006 I/O Bus Cable Assembly
  • TRICONEX 3003 Main Processor Module
  • TRICONEX 20064-320 I/O Module
  • TRICONEX 3006 Main Processor Module
  • TRICONEX AI3351S2 High Density Analog Input Module
  • TRICONEX DO3626X Digital Output Module
  • TRICONEX CM3201S2 Communication Module
  • TRICONEX 8305A 32 channel digital output module
  • TRICONEX 9668 7400172-110 3000590-110 Safety System I/O Card
  • TRICONEX IMFF4703X Fiber I/O Bus Interface Module
  • TRICONEX 3503EC1 24V Digital Input Module
  • TriconeX 4000103-546 Tricon TMR Controller
  • TRICONEX 4000094-350 EMI power filter
  • TRICONEX 4000093-346 Interface Component
  • TRICONEX 3902AX Universal I/O Card
  • TRICONEX 9760-2 Analog Input Terminal Panel
  • TRICONEX PLM3900N - Trident System Digital Input Module
  • TRICONEX 2483- Analog Output HART Base Board Kit
  • TRICONEX 2481- Analog Output Base Board Kit
  • TRICONEX 2480A - Hazardous Area Analog Output Base Board Kit
  • TRICONEX 2451- Solid State Relay Output Base Board Kit
  • TRICONEX 2402A - Hazardous Area Digital Output Basic Board Kit
  • TRICONEX 2402- High Voltage Digital Output Base Board Kit
  • TRICONEX 2401L - Low Current Digital Output Base Board Kit
  • TRICONEX 2401- Digital Output Base Board Kit
  • TRICONEX 2381 Pulse Input Base Board Kit
  • TRICONEX 2361- Analog/Digital Input Base Board Kit
  • TRICONEX 3700 TMR Analog Input Module
  • TRICONEX 9771-210F Termination Panel Assembly
  • TRICONEX MP3009 Processor Module
  • TRICONEX AO3482 Analog Output Module
  • TRICONEX D28799‑005 Power Interface Module
  • TRICONEX DI3361 Digital Input Module TMR
  • TRICONEX AT-2701FX 843-000844-00 REVD Industrial Ethernet Network Card
  • TRICONEX AI2361 7400210-020 Safety System Module
  • TRICONEX RO3451 Digital Output Module Relay
  • TRICONEX 4351A Industrial Communication Module
  • TRICONEX AI3351 Analog Input Module
  • TRICONEX 4000093-320 Safety Controller Module
  • TRICONEX AI2361 Analog Input Module
  • TRICONEX 2071H 7400313-100 Dual Power Module