YOKOGAWA AQ6360 Optical Spectrum Analyzer

F: | Au:FAN | DA:2025-11-06 | 392 Br: | 🔊 点击朗读正文 ❚❚ | Share:



YOKOGAWA AQ6360 Optical Spectrum Analyzer

Overview

The Introduction Guide to YOKOGAWA AQ6360 Optical Spectrum Analyzer (7th Edition, document number IM AQ6360-02EN) introduces the core functions of the instrument (high-speed measurement of optical characteristics of LD, LED light source, optical amplifier and other equipment), preparation before use (packaging content inspection, instrument installation, power connection and power on/off process), basic operations (touch screen/mouse/keyboard operation, menu and parameter settings), maintenance points (firmware update, wavelength/level accuracy calibration, daily cleaning and component replacement), and key specifications (wavelength range 1200-1650nm, maximum input power+20dBm) At the same time, it emphasizes safety precautions (such as avoiding direct exposure to infrared light, correctly grounding to prevent electric shock), and provides user registration, technical support contact information, and access to relevant manuals.


Preparation before use

1. Packaging content inspection

After unboxing, it is necessary to confirm that the host, standard accessories, and optional accessories are complete. The standard accessories are listed in the table below (optional accessories need to be purchased separately):

Category, Part Name, Model/Part Number, Quantity, Key Explanation

Host AQ6360 Host -1 Confirm that the back nameplate model is consistent with the order, and record the instrument number (to be provided when contacting the dealer)

Standard Attachment - Power Supply Cord A1006WD (UL/CSA) 1 needs to be matched with regional standards, such as A1064WD for China and A1009WD for Europe; Suffix - Y without power cord

Standard attachment - Other rubber foot pads A9088ZM 2 sheets A9088ZM includes 2 foot pads for fixing instruments to prevent sliding

Standard Attachment - Handbook Beginner's Guide IM AQ6360-02EN 1 Must Read Basic Document

Optional accessories - connector AQ9447 connector adapter (FC) AQ9447-FC - for optical input interface, also available in SC model (AQ9447-SC)

Optional accessories - connector AQ9441 connector adapter (FC) AQ9441-FC - for calibrating light source output interface, also available in SC model (AQ9441-SC)

2. Instrument installation requirements

Installation environment: For indoor use only, avoid direct sunlight, flammable and explosive environments, high vibration/high dust areas

Placement requirements: Horizontal and stable tabletop, anti tilt; Ventilation gap ≥ 200mm (side/back ventilation holes) to prevent internal overheating

Anti impact: Avoid falling (dropping ≥ 2cm may damage the internal monochromator), use original factory grade cushioning packaging during transportation

Rack installation: A separate rack kit (such as EIA standard 751535-E4, JIS standard 751535-J4) needs to be purchased, and the bottom should be supported and not obstruct the ventilation holes during installation

3. Power connection and power on/off

Power specifications: Rated voltage 100-240V AC, frequency 50/60Hz, maximum power consumption ≈ 100VA; allowable voltage range 90-264V AC, frequency 48-63Hz

Power on/off process:

Connect the power cord in the shutdown state (grounded, using a three pin socket);

Turn on the back MAIN POWER switch, and the front POWER light will turn orange;

After waiting for a few seconds, press the front POWER switch, the light turns green, and the instrument starts initialization (displaying STEP 1/9 to STEP 9/9);

To shut down, first press the front POWER switch, confirm the pop-up window, and then click "Yes". After the POWER light turns orange, turn off the MAIN POWER switch.

image.png

Basic Operations

1. Control method

Touch screen operation:

Click (select menu/input parameters), drag (move waveform/marker), pinch and zoom (enlarge/shrink waveform);

During waveform operation, a "Operation Tool Window" will pop up, supporting functions such as restoring the initial state and peak alignment.

Mouse/keyboard operation:

Mouse: Left click=Touch screen click, right-click on waveform area to pop up menu, drag to zoom in and out of waveform;

External keyboard: Supports shortcut key operations (such as [SHIFT]+[F1] to start scanning, [ALT]+[F6] to enter system settings). Please refer to the table on page 3-15 of the document for specific mappings.

2. Core operating procedures

Menu operation: Click on the "Three Menu" in the upper right corner of the screen to open the Main Menu window, select a function (such as SWEEP/SETUP/MARKER), switch submenus through "More", and click on the corresponding item to perform the operation.

Parameter input:

Numerical input: Click on the parameter value to pop up the "Parameter Input Window", and adjust it through the numeric keypad or arrow keys (COARSE/FINE switch step size);

String input: When entering a label/file name, a on-screen keyboard pops up, supporting cursor movement and character insertion/deletion.

DUT connection:

Clean the end face of the optical connector (using NTT-AT specialized cleaning agent, press and rotate to wipe);

Connect the optical fiber to the "Optical INPUT" interface of the instrument, and set "NORM" (regular PC) or "ANGLED" (APC) through Main Menu → SETUP → Fiber Connector.

Maintenance and Calibration

1. Firmware update

Update purpose: To enhance the functionality and usability of the instrument, the latest firmware needs to be downloaded from the Yokogawa official website;

Update method:

USB update: Create an "Update" folder in the USB root directory, place the. upd firmware file, and execute it through System → Version → Update (USB);

Network update: Connect to the PC via Ethernet, copy the firmware to the internal Update directory of the instrument, and execute it through Update (NETWORK);

Attention: Do not turn off the power during the update. The instrument will automatically restart after the update, and the settings data will be initialized (backup is required in advance).

2. Accuracy calibration

Wavelength calibration:

Applicable scenario: After 1 hour of preheating and before measurement, ensure wavelength accuracy (±) 0.02nm@1520-1580nm );

Tools: Use built-in reference light sources (/LFC/LSC options) or gas lasers with known wavelength accuracy;

Exception handling: If the error is greater than ± 5nm, contact the dealer for adjustment.

Level calibration:

Tools: 1310/1550nm light source, optical power meter;

Process: Connect the light source to the instrument, measure the peak level, and then connect the light source to the optical power meter to confirm that the difference between the two is within ± 0.5dB (meeting the level accuracy requirements).

3. Daily maintenance and component replacement

Daily cleaning:

External: Wipe with a dry cloth after power failure, and prohibit volatile chemicals;

Optical interface: Clean the connector end face with an alcohol swab and disable compressed air blowing (to prevent dust from entering the monochromator).

Component replacement cycle:

Key Explanation of Component Name Replacement Cycle

LCD backlight ≈ 70000 hours lifespan reference value under normal usage conditions

It is recommended to replace the cooling fan regularly for 3 years to prevent overheating

Backup battery (lithium battery) for 5 years to store settings data, needs to be replaced if expired


Safety and Compliance

1. Safety Warning

Warning (risk of fatal/serious injury):

Cannot directly view the optical output interface (built-in reference light source continuously outputs infrared light, which may cause blindness);

Grounding must be used, and ungrounded extension cords are prohibited;

Do not use in flammable and explosive environments, and do not disassemble the instrument by yourself (there is high pressure inside).

CAUTION (Minor Injury/Equipment Damage Risk):

The instrument is a Class A industrial equipment, which may cause radio interference when used in residential areas and needs to be resolved by the user themselves;

To avoid strong light input (which may damage optical components), initialization must be completed before connecting the DUT.

2. Compliance requirements

Environmental compliance: compliant with the EU WEEE Directive (must not be mixed with household waste for disposal) and the Battery Directive (lithium batteries must be separately recycled);

Laser compliance: The built-in laser light source is Class 1 (compliant with IEC 60825-1:2014, 21 CFR 1040.10/11), with a wavelength of 1.53 μ m and a maximum output power of 0.04mW;

Regional compliance: Taiwan region needs to inquire about restricted substance information for power cord (A1100WD) (official website) https://tmi.yokogawa.com/support/... ).


Key specification parameters

The core specifications of AQ6360 are shown in the following table (limited models should refer to IM AQ6360-51EN):

Specification category specific parameters

Suitable for fiber optic SM (9.5/125 μ m), GI (50/125 μ m, 62.5/125 μ m)

Wavelength range 1200-1650nm

Wavelength accuracy ± 0.02nm (1520-1580nm), ± 0.04nm (1580-1620nm), ± 0.10nm (1200-1650nm)

Wavelength resolution of 0.1/0.2/0.5/1/2nm (setting options), accuracy of ± 5%

Level sensitivity -80dBm (1300-1620nm, resolution 0.1nm, HIGH2 level)

Maximum input power+20dBm (single wavelength resolution input power), maximum safe input power+25dBm (total input power)

Level accuracy ± 0.5dB (1310/1550nm, input -20dBm, MID/HIGH1/HIGH2 levels)

Dynamic range 55dB (peak ± 0.4nm), 40dB (peak ± 0.2nm), resolution 0.1nm

Interface GP-IB, Ethernet, USB (2 each), SVGA output

Display 8.4-inch color LCD (touch screen, resolution 800 × 600 pixels)

Physical dimensions 426 (W) × 177 (H) × 459 (D) mm (excluding protective cover/handle)

Weight ≈ 15.5kg

The working environment temperature is 5-35 ℃, and the humidity is 20-80% RH (without condensation); Performance guarantee temperature 18-28 ℃

image.png

  • Basler D90 96801 100 PCB Card
  • Basler XR2002F Voltage Regulator (110 VAC, 48-480 Hz)
  • Basler SR8A-2B14B3A Regulator
  • Basler 9561500100 Module
  • Basler DECS-400 BE1-11 System
  • Basler DECS-100-B15 Excitation Control
  • Basler SCP 210 Frequency Controller
  • Basler SR4A-2B15B3A Static Voltage Regulator
  • Basler BE1-32R Power Relay
  • Basler PIA2400-17GM Power Interface Adapter
  • Basler MVC 232 Manual Voltage Control Module
  • Basler SSR 32-12 Static Voltage Regulator
  • Basler 5MW AVR Generator Voltage Regulator
  • Basler VR63-4B Voltage Regulator
  • Basler DECS-100-A05 AVR for Engine Generator
  • Basler DECS-100-B15 Automatic Voltage Regulator
  • Basler BE1-32R Directional Power Relay
  • Basler BE1-87B Differential Relay
  • Basler UFOV 260A Protective Module
  • Basler 9-2614-02-100 PCB Rev M
  • Basler DECS-100-B15 Digital AVR
  • Basler 9284900103 PS DECS-400N
  • Basler D4N3H1U Intertie Protection
  • Basler DECS-100-B15 A15 AVR
  • Basler KR4F Voltage Regulator
  • Basler BE26434 T14 Transformer
  • Basler SR8A-2B15B3A Regulator
  • Westinghouse 774B472A12 AR Relay
  • Basler DECS-100-B15 AVR
  • Basler XR2002F Regulator 110V
  • Basler SR125-E Static Regulator
  • Basler SSR 125-12 Regulator
  • Basler MOC2599 Motor Pot
  • Basler BE1-DFPR Feeder Relay
  • Basler CBS 305 Current Boost
  • Basler BE1-25 AutoSync
  • Basler MVC 300 Voltage Control
  • Basler BE3-25A AutoSync
  • Basler KR7FF Static Regulator
  • Basler 90-49000-100 Regulator
  • Basler 880 kVA Dry Type Transformer Specs
  • Basler Electric BE1-25 Sync-Check Relay Specs
  • Basler SSR 125-12 Voltage Regulator Specs
  • Basler Electric BE1-851 Overcurrent Relay Review
  • Basler Electric 149D930G02 Control Sub-Assembly
  • Basler Electric BE1-81O/UT Frequency Relay Specs
  • Basler Electric BE1-51/27C Overcurrent Relay
  • Basler Electric 149D956G02 Industrial Component
  • Basler Electric BE1-51A Overcurrent Relay Specs
  • Basler Electric BE1-40Q Loss of Excitation Relay
  • Basler DECS-200 Excitation Control System
  • Basler DECS-200 Voltage Regulator 56-277V AC / 125V DC
  • Basler BE1-87T Transformer Differential Relay
  • Basler RDP-110-S1 Protection Relay
  • Basler BE1-700V Digital Protective Relay
  • Basler BE1-951 Overcurrent Protection System
  • Basler DECS-300 Digital Excitation Control
  • Basler DECS-200 Digital Excitation Control
  • Basler DECS-200-1C Excitation Control System
  • Basler DECS-200-1L Digital Excitation Control
  • Basler Electric BE1-GPS Generator Protection System
  • Basler Electric DECS-200-1C Digital Excitation Controller
  • Basler Electric DECS125-15 Excitation Control with Power Module
  • Basler Electric BE1-87G Differential Relay
  • Basler Electric BE1-11 Protection System I5A3M2P2N0EA00
  • Basler Electric DECS-200-1C Excitation Control System
  • Basler Electric BE1-11g Generator Protection Relay
  • Basler Electric DECS 125-15-B2C1 V2.0.9 Excitation Control
  • Basler Electric BE1-81O/UT3ED1JA7N2F Frequency Relay
  • Basler Electric BE1-81O/UT3EE1YB7N1F Frequency Relay
  • Basler Electric DECS-200-1L Digital Excitation Control System
  • Basler DECS125-15-B2C1 Excitation Control
  • Basler 9507900205 SSR Retrofit Voltage Regulator
  • Basler BE2000E Digital Voltage Regulator
  • Basler BE1-GPS Generator Protection System
  • Basler DECS-250-CN1CN1N Digital Excitation Control
  • Basler DGC-2020 Genset Controller
  • Basler BE1-81O UT3ED1LA7N0F Frequency Relay (Variant)
  • Basler BE1-81O UT3EE1YA9S0F Frequency Relay (Variant)
  • Basler BE1-81O Over/Under Frequency Relay
  • Basler DECS125-15 Digital Excitation Control
  • Basler Electric BE1-951 Overcurrent Protection System
  • Basler Electric BE1-700V Digital Protective Relay
  • Basler Electric APR63-5 Automatic Voltage Regulator
  • Basler Electric BE1-851 Overcurrent Protection System
  • Basler Electric DECS-250-LN1SN1N Excitation Control
  • Basler Electric BE1-87T Transformer Differential Relay
  • Basler Electric DECS-200-1L Excitation Control System
  • Basler Electric 9310300100 DECS-300 Excitation Control
  • Basler Electric SSE-N 125-4.5KW Shunt Exciter Regulator
  • Basler Electric DGC-2020HD-5NS1DNSBA Genset Controller
  • Basler Electric BE1-81-O/UT3EE1JB7N1F Frequency Relay
  • Basler Electric BE1-81T1EE1WA0N1F Frequency Relay
  • Basler Electric BE1-25M1EA6PN5R1F Sync-Check Relay
  • Basler Electric BE1-GPS Generator Protection System
  • Basler Electric DECS-250-LN1SN1N Excitation Control Rev V
  • Basler Electric DECS-250-CN2CN1N Excitation Control
  • Basler Electric BE1-50/51B-207 Overcurrent Relay
  • Basler Electric DECS-300-C0N0 Excitation Control System
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric DECS-250-LN1CN1N Excitation Unit
  • Basler Electric DECS-250 LN2SA1D Excitation Unit Specs
  • Basler Electric BE1-87T Transformer Relay Review
  • Basler Electric BE1-11 Protection System
  • Basler Electric BE1-GPS100-E4N1H1N Protection System
  • Allen-Bradley 442G-MABH-R Safety Module
  • Beckhoff CX1030-0111 PLC Assembly Profile
  • FANUC IC693CPU364 PLC Module
  • Orange Denmark Type 200816 220 PLC Specs
  • OMRON C200H-SNT31 Sysmac PLC Module
  • Allen Bradley 20AB022A3AYNANC0 PowerFlex 70
  • OMRON C200HW-PCU01 Position Control Unit
  • ABB AO845A-eA Analog Output Module
  • OMRON CJ1M-CPU22 CPU Unit
  • Allen Bradley 100-E265ED11 Contactor
  • Honeywell 51304511-100 Interface Module
  • SOLEXY BXF3S0101N0018 Gateway Module
  • OMRON CJ2H-CPU65 CPU Unit
  • Automation Direct GS2-45P0 AC Drive
  • M68-2000 2-Axis Motion CNC Controller
  • OMRON CJ1M-CPU11 V3.0 PLC CPU Unit
  • OMRON CJ1W-NC413 4-Axis Positioning Controller
  • OMRON 3G2A3-PRO16 Programming Console HMI
  • Siemens 3VT8440-2AA04-2GA2 Molded Case Circuit Breaker
  • Siemens 3RT5045 Contactor Series
  • OMRON C200HS-CPU01-E SYSMAC PLC Controller
  • OMRON C500-NC103-E Positioning Control Unit
  • OMRON CJ1W-TC001 Temperature Control Unit