Summary of Key Parameters (Core Commonly Used)
Parameter Category Parameter Name Typical Settings/Range Adjustment Scenarios
Motion parameter acceleration time (C1-01) 0.01-3600s: Prolonged if the startup impact is large, shortened if quick startup is required
The deceleration time of motion parameters (C1-02) is extended from 0.01 to 3600 years due to deceleration overvoltage, and can be shortened by combining with braking resistors
Protection parameter motor overload protection (L1-01) 1-6 levels, single motor drive selects 1-3 levels, multi motor drive selects 0 levels (disabled)
Sensor Parameters Polarity Sensor Mode (T1-01) 0-5 Induction Motor Select 0 (Rotation Tuning), PM Motor Select 4 (Rotation Tuning)
Cooling parameters: Water cooling flow threshold ≥ 4 liters/minute. Water cooling models require flow monitoring. If the threshold is lower, the machine will be shut down