Model selection and ordering information
(1) Model coding rules
Taking "DCS 500B-0250-51-4Q" as an example, the key parameter meanings are:
500B ": Basic model;
0250 ": Output current 250A;
51 ": Voltage level 500V DC;
4Q ": Running in 4 quadrants.
(2) Core selection criteria
Motor parameters: Select the module based on the rated power of the DC motor, armature voltage/current, and excitation voltage/current (e.g. 100kW/440V motor compatible with DCS 500B-0250-51);
Application requirements: Select 4-quadrant module for energy feedback, DCS 600+AMC-DC communication board for multi motor synchronization, and water-cooled module for high temperature environment;
Power grid conditions: The public power grid needs to be equipped with EMC filters, and if the power grid harmonics are severe, line reactors need to be added.