Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • MEZ UD 1104 2.5 kW BONFIGLIOLI Trasmittal 300L19 Gear Motor 300L19.00HZP90AW0A
    ❤ Add to collection
  • MEZ UD 1104 2.5 kW BONFIGLIOLI Trasmittal 300L19 Gear Motor 300L19.00HZP90AW0A

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥22634.00
      ¥23421.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:1.260KG
    • Quantity:
    • (Inventory: 56)
Description
<span style="font-size: 18px; font-family: arial;">MEZ UD 1104 Gear Motor 2.5 kW Trasmittal</span>

MEZ UD 1104 2.5 kW BONFIGLIOLI Trasmittal 300L19 Gear Motor 300L19.00HZP90AW0A

The MEZ UD 1104 2.5 kW BONFIGLIOLI Trasmittal 300L19 gear motor, identified by code 300L19.00HZP90AW0A, is a medium power integrated drive unit that combines a MEZ motor with a Bonfiglioli Trasmittal industrial reducer. Trasmittal is a brand within the Bonfiglioli group, and the 300 series is used in demanding drive systems that require robust construction and reliable torque transmission. This gear motor is suitable for conveyors, mixers, and heavy industrial machinery.

Product Overview

The MEZ UD 1104 motor provides the input power and speed for the assembly. The 2.5 kW rating places the motor in the medium power range suitable for general industrial duties. The Bonfiglioli Trasmittal 300L19 reducer reduces the motor speed and increases output torque. The 300L19.00HZP90AW0A code defines the shaft, flange, mounting, and option details of the specific build.

The gear motor is assembled as a matched unit so that the motor shaft and reducer input are correctly engaged. The integrated design reduces the number of separate transmission components that must be sourced and aligned. The combined unit can be used in conveyors, mixers, and general industrial equipment where a robust right angle drive is preferred.

Construction and Design

The MEZ motor housing supports the stator, rotor, bearings, and shaft. The stator windings are insulated for industrial operation. The rotor is mounted on a shaft supported by bearings selected for the expected loads. The fan and fan cover provide cooling airflow over the housing. The terminal box provides a safe connection point for the electrical supply.

The Bonfiglioli Trasmittal 300L19 reducer uses robust gear stages and bearings selected for high torque loads. The housing maintains correct alignment between the gear stages under load. Seals protect the lubricant and bearings from dust and moisture. Lubrication is contained within the housing and distributed to the gear mesh and bearings during operation. The output shaft is machined to accept couplings, pulleys, sprockets, or other driven components.

Performance Characteristics

The MEZ UD 1104 motor provides the input power and speed for the assembly. The 2.5 kW rating provides enough power for medium duty applications. The Trasmittal 300L19 reducer reduces the motor speed according to its ratio and increases output torque. The robust gear design supports smooth torque transfer and reliable operation under load.

The integrated drive should be selected with an appropriate service factor for the duty cycle. Starting loads, shock loads, and continuous operation affect the thermal and mechanical capacity of the assembly. The motor should be protected against overload and abnormal supply conditions. The reducer should be checked for thermal capacity when operating at high duty cycles or high ambient temperatures.

Applications

The MEZ UD 1104 with Bonfiglioli Trasmittal 300L19 reducer is suitable for belt conveyors, screw conveyors, mixers, agitators, packaging machines, and heavy industrial machinery. The medium power rating makes the unit useful in applications that require more torque than small gear motors can provide. The robust construction supports reliable operation in demanding environments.

The motor can be connected to standard industrial supply arrangements according to the nameplate rating. The geared drive can be used in applications that require frequent starting and stopping, provided that the duty cycle and thermal capacity are considered. Correct selection helps ensure reliable operation and long service life.


Installation Guidelines

Installation should begin with a check of the nameplate data and a visual inspection of the assembly. The geared motor should be mounted on a rigid base that can withstand the torque reaction. Mounting bolts should be tightened to the recommended torque. The motor should be connected according to the terminal diagram for the available supply voltage. The output shaft should be aligned with the driven equipment to avoid excessive radial and axial loads.

After installation, the assembly should be checked for smooth rotation and correct oil level in the reducer. A short run without load helps confirm that the motor and reducer operate correctly. The direction of rotation should be verified before connecting the load. Any unusual noise, vibration, or temperature rise should be investigated before full service.

Maintenance Recommendations

Regular maintenance supports reliable performance and long service life. The motor cooling fan and fan cover should be kept clean. The reducer oil level and oil condition should be checked at recommended intervals. Seals and bearings should be inspected periodically. Leakage, abnormal noise, or vibration should be addressed promptly. Electrical connections should be checked for tightness and signs of overheating.

The exterior of the motor and reducer should be kept clean to support heat dissipation. Adequate airflow around the assembly helps maintain stable temperatures. In dusty or humid environments, additional protection may be needed. Maintenance records help identify trends and support planned servicing. Following a consistent maintenance schedule reduces the risk of unexpected downtime.

Selection Considerations

When selecting the MEZ UD 1104 with Trasmittal 300L19 reducer, engineers should confirm the supply voltage, frequency, motor power, output speed, output torque, duty cycle, and environmental conditions. The reducer ratio and motor speed determine the output speed. The available torque depends on motor power and reducer efficiency. A service factor should be applied for starting loads, shock loads, and continuous operation.

The motor and reducer interfaces must match. The mounting arrangement should suit the machine layout and provide adequate support. The output shaft and mounting features should match the driven equipment. Correct selection and installation help ensure smooth operation, stable thermal behavior, and long service life.

Conclusion

The MEZ UD 1104 2.5 kW Bonfiglioli Trasmittal 300L19 gear motor offers a medium power integrated drive solution with a robust industrial reducer. Its construction supports dependable torque transmission in conveyors, mixers, and heavy machinery. With correct installation and maintenance, the assembly provides stable performance and long service life.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection
  • BENDER RCMA475LY Residual Current Monitoring
  • BENDER IRDH575 Insulation Monitoring
  • BENDER IRDH265 Insulation Monitoring and Debugging
  • Bender RCMA475LY residual current monitor debugging
  • Beckwith Electric M-3425A Generator Protection Relay Debugging Guide
  • Automated MEX816U Expander Troubleshooting Guide
  • ASEM HT2150 Industrial Tablet Selection and Troubleshooting
  • Troubleshooting and practical application of Advantest U3771/3772 microwave spectrum analyzer
  • Advantest R6144 Programmable DC Voltage/Current Source (Calibration Source) Calibration and Maintenance
  • Aerotech UNIDEX 100/U100i single axis motion controller
  • Aerotech Ndrive MP Ultra Compact PWM Digital Servo Driver
  • Aerotech Ndrive HPe 10/20/30 High Performance PWM Digital Servo Drive
  • Aerotech Ndrive HLe maintenance replacement
  • Aerotech Ndrive CP maintenance replacement
  • Aerotech Ndrive Linear Drive Selection
  • Aerotech NDrive HL linear drive maintenance replacement
  • Aerotech NDrive HP 10/20/30 Maintenance and Replacement
  • Aerotech NDrive CP10 Servo Drive Guide
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC