Schneider Electric Foxboro ™ DCS FBM201/b/c/d analog input module

F: | Au:FAN | DA:2025-09-15 | 836 Br: | 🔊 点击朗读正文 ❚❚ | Share:

Schneider Electric Foxboro ™  DCS FBM201/b/c/d analog input module

Product core positioning and application scenarios

FBM201/b/c/d is Schneider Electric EcoStruxure Foxboro ™  The core function of the analog input module in distributed control systems (DCS) is to accurately convert the analog signals (current, voltage, millivolt level signals) output by industrial field sensors (such as pressure, temperature, flow sensors) into digital signals, which are transmitted to DCS controllers (such as Field Control Processor, FCP) to achieve real-time acquisition and monitoring of process parameters. Its typical application scenarios cover process industries such as petrochemicals, power, water treatment, and manufacturing, and are suitable for industrial control scenarios that require high accuracy of analog signals and complex environmental conditions (such as Harsh level harsh environments).


Product Model and Core Classification

The FBM201 series includes 4 sub models, with the core difference being the supported analog input signal range, which can be flexibly selected according to the type of sensor on site:

Model input signal range key adaptive sensor

FBM201 0-20 mA DC (compatible with 4-20 mA industrial standard signal) 4-20 mA two-wire/four wire transmitter (such as pressure transmitter, liquid level transmitter)

FBM201b 0-100 mV DC millivolt level signal sensor (such as strain gauges, thermocouple signal conditioning output)

FBM201c 0-5 V DC 0-5 V voltage output sensor (such as some temperature sensors, concentration sensors)

FBM201d 0-10V DC 0-10V voltage output sensor (such as high-precision flow sensor, displacement sensor)

Core technical specifications and performance parameters

(1) Input channel and signal conversion

Category specific parameter description

Number of channels: 8 independent channels. Each channel can be separately connected to different types of sensors (matching corresponding module models), and the channels do not interfere with each other

Isolation design between channels and between channels and ground: Galvanically isolated. The isolation voltage reaches 600 VAC (1-minute withstand), effectively suppressing electromagnetic interference (EMI) in industrial sites and preventing signal crosstalk and grounding loop problems

The signal conversion is independent for each channel. The sigma delta (∑ - Δ) A/D converter has a fast conversion rate and can update the analog input reading once every 25 ms; Support software configuration integration cycle, filter out process noise and electromagnetic noise, and improve data stability

Measurement accuracy ± 0.03% range (including linear error), temperature coefficient ± 50 ppm/℃. High precision conversion ensures the reliability of collected data. A low temperature coefficient means that accuracy degradation is small when the ambient temperature changes (such as -20-70 ℃ in industrial sites)

Input impedance - FBM201 (current input): 61.5 Ω (nominal)

-FBM201b/c/d (voltage/millivolt input): 10 M Ω current input impedance low, matching 4-20 mA transmitter load requirements; High voltage input impedance to avoid attenuation of sensor output signals

(2) Electrical and environmental adaptability

Power requirements:

Input voltage: 24 VDC redundant power supply (+5%/-10% fluctuation tolerance), supporting dual independent power supplies to ensure uninterrupted operation of the module;

Power consumption: 7 W (nominal), heat dissipation 3 W (maximum), low-power design reduces control cabinet heat dissipation pressure.

Environmental specifications:

Working temperature: -20-70 ℃ (-4-158 ° F), storage temperature -30-85 ℃;

Humidity: 5% -95% (without condensation);

Vibration and impact: 0.75 g (5-500 Hz), in compliance with industrial grade anti vibration standards;

Environmental level: Meets the requirements of ISA S71.04 Class G3 (Harsh, harsh environment), and can withstand complex industrial site conditions such as dust, humidity fluctuations, and sudden temperature changes.

Anti interference capability:

Common mode rejection ratio (CMRR):>100 dB (50/60 Hz);

Differential Mode Rejection Ratio (NMRR):>95 dB (50/60 Hz);

Compliant with EN 61326-1:2013 Class A electromagnetic compatibility (EMC) standard, with strong resistance to electromagnetic radiation and conducted interference.

Hardware design and installation configuration

(1) Hardware structure characteristics

Physical protection: Adopting extruded aluminum alloy shell with high mechanical strength, it can protect internal circuits from physical impact and dust intrusion;

Hot swappable design: supports online removal/replacement (Hot Swap), without disconnecting on-site wiring, power or communication cables, reducing system downtime and improving maintenance convenience;

Status indication: The front of the module is integrated with LED indicator lights, which can intuitively display the power status, communication status, and channel fault status (such as overcurrent and signal abnormality), making it easy to quickly troubleshoot problems;

Redundant communication: Communicate with DCS controller (FCP/FCM) through a 2 Mbps redundant fieldbus, supporting A/B dual path switching. If one path fails, it will automatically switch to the other, ensuring uninterrupted data transmission.

(2) Installation and wiring configuration

Installation method:

The module needs to be installed on a modular base plate (FBM Baseplate), which supports DIN rail installation (horizontal/vertical) or 19 inch rack installation (requires installation kit);

A single bottom plate can accommodate up to 4 or 8 FBM modules, supporting dense layout of multiple modules and saving control cabinet space.

Wiring and Terminal Components (TA):

The on-site wiring is connected to the Terminal Assembly (TA) module installed through DIN rails. TA is divided into "Compression Terminal Type (C)" and "Ring Terminal Type (RL)", suitable for different wire types (solid/multi strand wire);

The TA is connected to the module through a termination cable, which can be made of polyurethane (P/PVC) or low smoke halogen-free (LSZH), with a length of 0.5-30 meters (1.6-98.4 feet), and supports local or remote wiring (such as installing TA in adjacent control cabinets to reduce on-site wiring length);

Wire specifications: Compression terminals support 0.2-4 mm ² (24-12 AWG) wires, while ring terminals support 0.5-4 mm ² (22-12 AWG) wires, suitable for most industrial wiring needs.


Compliance certification and security features

(1) Compliance certification

Specific standard specifications for certification categories

Safety Certification - UL/UL-C: Class I, Groups A-D, Division 2 (Hazardous Areas), Temperature Class T4

-European Low Voltage Directive (2014/35/EU)

-ATEX 94/9/EC: II 3 G Ex nA [nL] IIC T4 (Zone 2 explosion-proof area)

-IECEx certification can be used in flammable and explosive environments (such as Zone 2 in petrochemical workshops), meeting major global industrial safety standards and adapting to cross-border project requirements

Environmentally compliant EU RoHS Directive (2011/65/EU, including amendments 2015/863, 2017/2102) does not contain harmful substances such as lead and mercury, meets environmental requirements, and is suitable for industries with high environmental standards (such as food processing and pharmaceutical manufacturing)

Electromagnetic compatibility (EMC) European EMC Directive (2014/30/EU), compliant with EN 61326-1:2013 Class A in industrial strong electromagnetic environments (such as near motors and frequency converters), with low module radiation and strong anti-interference ability, ensuring signal stability

(2) Security protection function

Overcurrent protection: Each channel is designed with a current limiting circuit, which limits the current to less than 30 mA during normal operation and approximately 100 mA during short circuits to prevent damage to sensors or modules due to overcurrent;

Voltage limit: It is prohibited to connect voltage signals exceeding 30 VAC or 60 VDC to avoid violating electrical safety regulations and prevent personnel from getting electric shock and module burnout;

Class 2 Circuit Certification: Communication circuits comply with the Class 2 circuit requirements of the National Electrical Code (NFPA 70 Article 725) and the Canadian Electrical Code (CSA C22.1 Section 16), and are classified as limited energy circuits with high safety.

Model and accessory ordering information

(1) Core product model

Product type and model description

Analog input module FBM201 0-20 mA DC input

FBM201b 0-100 mV DC input

FBM201c 0-5 V DC input

FBM201d 0-10V DC input

Terminal component (TA) RH916XG (FBM201, compression terminal) is compatible with 8 current inputs of FBM201 and has compression wiring

P0917JK (FBM201, ring terminal) is compatible with the 8-channel current input of FBM201 and has a ring terminal

RH922ZM (FBM201b, compression terminal) is compatible with the 8-channel millivolt input of FBM201b and has compression wiring

RH922ZN (FBM201c, compression terminal) is compatible with 8-channel 0-5V input of FBM201c, with compression wiring

RH922ZP (FBM201d, compression terminal) is compatible with 8 channels of 0-10V input of FBM201d, with compression wiring

P0926SQ (FBM201d, ring terminal) is compatible with the 8-channel 0-10V input of FBM201d and has a ring terminal

(2) Terminal cable selection

Terminal cables are used to connect TA and FBM modules, classified by material and length, with the following core models:

Cable Material Length (meters/feet) Model (P/PVC material) Model (LSZH material)

Polyurethane (P/PVC) 0.5/1.6 RH916DA RH928AA

Low Smoke Zero Halogen (LSZH) 1.0/3.2 RH916DB RH928AB

2.0/6.6 RH931RM RH928AC

3.0/9.8 RH916DC RH928AD

5.0/16.4 RH916DD RH928AE

10.0/32.8 RH916DE RH928AF

15.0/49.2 RH916DF RH928AG

20.0/65.6 RH916DG RH928AH

25.0/82.0 RH916DH RH928AJ

30.0/98.4 RH916DJ RH928AK

Note: LSZH material cables have low smoke and no halogen release during combustion, making them suitable for scenarios with high fire safety requirements (such as underground factories and enclosed spaces).

  • SIGMATEK PC321K Industrial Computer
  • SIGMATEK MDP 102-1 SLIDES Power Module
  • SIGMATEK TAE-151 12-200-151 Light Terminal
  • SIGMATEK CP102 20-004-102P6995B HMI Panel
  • SIGMATEK CAM-123 12-017-123-C Analog Mixing Module
  • SIGMATEK DCC041 DIAS Compact Controller
  • SIGMATEK DVI021 and DKL015 DIAS Power Module
  • SIGMATEK SDD340-46 SDD Series Servo Drive
  • SIGMATEK Robotdrive L6 02220-7997 Engel Drive
  • SIGMATEK AKM63M-ANCNGBB0 4.38kW PM Servomotor
  • Sigmatek SDD 310 SLIDES-Drive SDD310-4O
  • Sigmatek SDD335-23K Drive VARAN Interface 14kVA
  • Sigmatek TAE1922-K Touch Display Unit
  • Sigmatek DIAS DCP 643 CPU Module DKL003
  • Sumitomo CNH-4105Y-43 NSNP Gear Reducer
  • Sumitomo CHHP-4160Y-35-213T Inline Gear Reducer
  • Sumitomo CNHM02-6090YA-87 NSNP Gear Motor
  • Sumitomo CNVXS-6100Y-43 NSNP Gear Reducer
  • Sumitomo CNHM2609511 Gear Motor
  • Sumitomo CHVM3-6130-B-35 Gear Motor
  • Sumitomo HW0389042-A Industrial Component
  • Sumitomo F2CF-W55-ZG05-64 Gear Reducer
  • Sumitomo CHH-6165Y-13 Inline Gear Reducer
  • Sumitomo CNVM3-6125C-EP-6 Cyclo Gear Motor
  • Sumitomo RNYX-1320Y-20 Gear Reducer
  • Sumitomo XFCG111-43/24/165 Control Component
  • Sumitomo LHYJ-3A105K-Y3-102 Gear Reducer
  • Sumitomo CNFM02-6095DA-B-121 TC-FX/FB-02A Motor
  • Sumitomo CNHJ-4105DAY-289 NSNP Gear Reducer
  • Sumitomo LHYJS-4C145Y-Y1-112 NSNB Gear Reducer
  • Radiator 2060351111 Komatsu Sumitomo Linkbelt
  • Sumitomo BL3-09B-35MEHDK6 Gearbox ANFJ-L30
  • Sumitomo Truninger 8H1-150 Internal Gear Pump
  • Sumitomo RNFMS01-25R-B-150 200V NSNP Gearmotor
  • Sumitomo CHHBJN1HA-6135Y-29 Inline Reducer
  • Sumitomo EHYMS5-B6125YA-Y3-74 NSNB Reducer
  • Sumitomo Eaton H-050AA2F-J Orbit Motor
  • Sumitomo TC-FXVP Motor 0.75kW 4P 400V N-80M
  • Sumitomo XFCG111-87/24130 Industrial Control Component
  • Sumitomo AF3122-030 Inverter 30kW 3Ph 200V
  • Sumitomo QT42-25FS-B Internal Gear Pump
  • Sumitomo F2CS-A35-ZG09-59 Speed Reducer
  • Sumitomo CNHM05-6090-B-29 Gear Motor
  • Sumitomo CHHJ-6145Y-29-210T Gear Reducer
  • Sumitomo E3P-20-2.2-S1450-E Hydraulic Pump
  • Sumitomo RNYMS1-1420C-AV-20 Right Angle Gear Motor
  • Sumitomo SR101 SRKG101-76-40-060 Reamer Head
  • Sumitomo RNYM05-1220-25/UBAABB Gear Motor
  • Optidrive E3 Sumitomo GHB-36 Vector Inverter Motor
  • Sumitomo CNH-614HY-35 UNMP Gear Reducer
  • Sumitomo CNH-612HY-6 SM-Cyclo Gearmotor
  • Sumitomo HF3214-A75 Electric Motor
  • Sumitomo CNVM02-6100-B-59 NSMP Gear Reducer
  • Sumitomo CNHJ4105Y35 NSNP Gear Reducer
  • Sumitomo CHH6165Y-29 NSNB Gear Reducer
  • Sumitomo RNYM1-1420-25 Hyponic Gear Motor
  • Sumitomo T600C Industrial Control Unit
  • Sumitomo LHH-4A115-K2-28 NSNB Gear Reducer
  • Sumitomo RNYM02-1220-AV-20 Speed Reducer
  • Sumitomo CHHS-6140Y-SB-17 Gear Motor
  • Sumitomo Heavy Industries SSE-100A-RM Drive Unit
  • Sumitomo PA228771 CNHM2-6100YB-EP-8 Gear Motor
  • Sumitomo RNYM02-1231-B-50 Speed Reducer
  • Sumitomo CNFM1H-6090-6 Induction Motor
  • Sumitomo CHH-614HY-11 Gear Reducer
  • Sumitomo F4C-D25-ZG01-41 Speed Reducer
  • Sumitomo PA224280 CNHM1-6095YC-EP-21 Gear Motor
  • Sumitomo KHYJB4115K185145TC Gear Motor
  • Sumitomo LHYJS-3A105Y-Y1-179 NSNB Gearmotor
  • Sumitomo AF3102-022 BN AC Driver
  • Sumitomo SG75M-H Operator Panel
  • Sumitomo NT2014-2A2 NSNP Control Unit
  • Sumitomo RNYMS03-1320-B-60 Gear with Motor
  • Sumitomo F90L/4 F90L4 Drive Motor
  • Sumitomo TC-FX NSMP Motor Unit
  • Sumitomo RNYM05-1210-7 NSMP Gearmotor
  • Sumitomo Fine Cyclo F2CFS-C45-59 Gearbox
  • Sumitomo Heavy Industries SSE-50A Industrial Unit
  • Sumitomo CHH-6130Y-17 NSNB Gear Reducer
  • Sumitomo UMC556000-02 Control Unit
  • Sumitomo CHHJ-4155Y-87 Inline Gear Box
  • Sumitomo ANFXS-P120F-M30GLD-5 NSNP Reducer
  • Sumitomo CNHJ-6095Y-17 NSNP Gear Reducer
  • Sumitomo H-3115 17:1 USNT Gear Reducer
  • Sumitomo CHH 6135Y USNTC02 Gear Reducer
  • Sumitomo JA450918A2 45JA918A Cylinder Head
  • Sumitomo SD4SGS-ACB-02C-110-54 Solenoid Valve
  • Sumitomo CNVMS02-6100DAYA-231 NSMD Gear Reducer
  • Sumitomo CHH4135Y8 NSMD Inline Gear Reducer
  • Sumitomo PA020201 CNH-6125Y-87 Worm Gear Reducer
  • Sumitomo Connectivity 8100-2730 Connector
  • Sumitomo CNHJ-6120Y-87 PA021857 NSNB Gear Reducer
  • Sumitomo RNYM02-1330-B-100 Induction Gear Motor
  • Sumitomo JA762913AC Operator Interface Keypad
  • Sumitomo CQT51-100FV-S1262J-A Coolant Pump
  • Sumitomo PA225389 CNHM1-6095YC-EP-6 Gear Motor
  • Sumitomo CHHJ-4130Y-43 NSNB Gear Reducer
  • Sumitomo RNYJ-1520Y-12 NSNB Gear Reducer
  • Sumitomo HC1480-29.00 NSMD Inline Gear Reducer
  • Sumitomo MC-550 MCU UMC550000AEG01
  • Sumitomo CNVM1H-6125YA-B-87 Gear Reducer
  • Sumitomo SD4GS-ACB-02B-110-54 Solenoid Valve
  • Sumitomo HCS79310 Main Motor Assembly
  • Sumitomo JA762913AC Operator Interface Keypad
  • Sumitomo CNHJ-6125Y-8 In Line Reducer
  • Sumitomo X120D30303T-01 Driver
  • Sumitomo H1Y203-25-F7000 Shaft Mount Reducer
  • Sumitomo Type-35SE Fiber Fusion Splicer Kit
  • Sumitomo F2CS-T655-171 Cyclo Drive Gearbox
  • Sumitomo F80 Adsorber RX19ZT6124
  • Sumitomo MC-550 MCU UMC550000AKG01
  • Sumitomo Drive FCS-A65G-59 Speed Reducer
  • Sumitomo SRA81-56-BM50-140 Modular Reamer Holder
  • Sumitomo CNHM05-6100YA-59 Gear Motor
  • DEMAG Sumitomo Ergocontrol NC4 100 V7 Control Unit
  • Sumitomo HMV02-207 Cyclo Drive Induction Motor
  • SUN-EH Sumitomo Z4-22172-12 Ozone Power Unit
  • Sumitomo AF-500 AF502-2A2 Transistor Inverter
  • Sumitomo T-82C+ Core Alignment Fusion Splicer
  • Sumitomo P741F6002B Circuit Board
  • Sumitomo AS-3211 Injection Molding Motherboard
  • Yaskawa SGMGH-13Q5A-OM11 Servo Motor with Sumitomo F3CS-A25G-59 Gear
  • Sumitomo SH120-5 Final Drive Track Travel Motor
  • Sumitomo AS-3345 Circuit Board
  • Sumitomo AF300S-1A5-E Transistor Inverter 1.5kW
  • Sumitomo Type-Q101-CA SM MM Fiber Fusion Splicer
  • Sumitomo SH50 NIV Operator Panel
  • Sumitomo RNFM-009-17L-B-120-N4FCZ843 AC Gear Motor