2. Special version (PR6423/xxx xxx RAD)
Specially designed for radiation environments, there are differences between technical parameters and standard versions:
Material adjustment: The probe material is changed to epoxy resin, the cable is changed to polyolefin, and the shell is made of stainless steel with EPDM O-ring seal to improve radiation resistance.
Temperature and radiation tolerance: The working temperature drops to -35~+80 ° C (-31~176 ° F); The anti radiation dose of the sensor (including 1-meter cable) reaches 80 Mrad, and the anti radiation dose of the extension cable and converter reaches 0.1 Mrad; At a radiation intensity of 0.5Sv/h, the calculated lifespan is 18.26 years in a neutron radiation environment and 183 years in a beta or gamma radiation environment.
Certification restriction: Non hazardous area certification, only applicable to ordinary radiation environments.
Optional accessories
Model Product Description Purpose
EZ 1600 probe bracket fixes the sensor to ensure precise installation position
MPT 064 metal protective tube protects sensors and cables against mechanical damage