Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • SICK S30A-6111CL S3000 PROFINET Safety Laser Scanner
    ❤ Add to collection
  • SICK S30A-6111CL S3000 PROFINET Safety Laser Scanner

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥36521.00
      ¥36631.00
      ¥36521.00
      ¥36521.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:13.200KG
    • Quantity:
    • (Inventory: 2314)
Description
<span style="font-size: 18px; font-family: arial;">SICK S30A-6111CL S3000 PROFINET Safety Laser Scanner</span>

SICK S30A-6111CL S3000 PROFINET IO Advanced Safety Laser Scanner

The SICK S30A-6111CL (order number 1052593) is a PROFINET IO Advanced safety laser scanner from the S3000 series. Designed for industrial applications requiring reliable protection of personnel and equipment, this scanner uses optical distance measurement to monitor a 5.5 m protective field. The device integrates directly into PROFINET and PROFIsafe networks, eliminating the need for hardwired safety outputs. The S30A-6111CL is part of SICK's comprehensive safety portfolio and is suitable for stationary and mobile applications, including AGV collision avoidance and hazardous area access monitoring.

Technical Specifications

The S30A-6111CL features a sensor head with a 5.5 m protective field range and a 49 m warning field range. The scanning angle is 190°, providing wide-area coverage. Resolution is configurable from 30 mm to 150 mm, with an angular resolution of 0.5° or 0.25° depending on range. The response time is 60 ms (base response time) plus multiple sampling selection. The device includes an integrated PROFINET switch with two RJ45 ports. Communication is via PROFINET and PROFIsafe (safety profile). The scanner has no local inputs or outputs; all safety signals are transmitted via PROFIsafe. The supply voltage is 24 V DC. The device is housed in a robust enclosure suitable for indoor use. It measures approximately 185 mm × 155 mm × 160 mm and weighs 3.71 kg. The scanner features a 100 mm protective field supplement to detect objects above the scanning plane.

Key Features

  • 5.5 m protective field range (49 m warning field range)

  • 190° scanning angle for wide coverage

  • PROFINET IO (2-port switch) and PROFIsafe communication

  • No local I/O; all safety signals via PROFIsafe

  • Configurable resolution: 30, 40, 50, 70, 150 mm

  • Angular resolution: 0.5° or 0.25°

  • Up to 4 configurable field sets and 8 fields

  • Simultaneous monitoring of up to 2 protective fields

  • Integrated configuration memory

  • Restart interlock, multiple sampling, and simultaneous monitoring functions

  • Diagnostic data output via RS-422 interface

Safety Ratings and Compliance

The S30A-6111CL is certified to Type 3 (IEC 61496) with a safety integrity level of SIL2 (IEC 61508). It meets Category 3 (EN ISO 13849) with a performance level of PL d. The PFHD is 8.0 × 10⁻⁸, with a mission time of 20 years (EN ISO 13849). The device has a restart interlock, multiple sampling, and protective field switching functions. All safety-related data logic is zero for safe state.

PROFINET and PROFIsafe Integration

The S30A-6111CL integrates directly into PROFINET networks as an IO device. The two integrated Ethernet ports act as a switch, allowing daisy-chaining of multiple devices without external switches. PROFIsafe transmits safety-related data (status of protective fields, restart interlock requests, etc.) to a fail-safe PLC. The GSDML file (provided by SICK) facilitates seamless integration into TIA Portal, STEP 7, or other PROFINET-compliant engineering environments. The device supports conformance class B, RT real-time class, and MRP (Media Redundancy Protocol). It also includes SNMP, MIB-2, and LLDP for network diagnostics.


Applications

The S30A-6111CL is suitable for safety applications including stationary hazardous area monitoring, AGV (automated guided vehicle) collision avoidance, robotic cell access monitoring, and perimeter protection. The PROFINET IO interface is ideal for integration into Industry 4.0 systems, enabling real-time safety data exchange and diagnostic information.

Configuration and Diagnostics

Configuration is performed using SICK Safety Designer software. Users can define up to 4 configurable field sets and 8 fields, with the ability to switch fields dynamically during operation. The device supports both static protective field switching and simultaneous monitoring of two fields. The RS-422 interface provides measurement data output for diagnostic purposes. The integrated configuration memory stores field parameters, eliminating the need for external storage.


Installation and Maintenance

The S30A-6111CL is installed using the supplied mounting bracket (order separately). The sensor must be positioned with a clear line of sight to the protected zone. The device has a 100 mm protective field supplement to prevent undetected approaches from below the scanning plane. Clean the front window regularly for optimal performance. The device does not contain user-serviceable parts. A system plug (separate accessory) is required for power and configuration access.

Environmental and Compliance

The S30A-6111CL is CE and RoHS compliant. It is designed for indoor use only (IP65 enclosure). Operating temperature: 0°C to 50°C. Storage temperature: -25°C to 70°C. Humidity: 10-90% non-condensing. Vibration resistance: 2g (10-55 Hz).

Conclusion

The SICK S30A-6111CL S3000 PROFINET IO Advanced safety laser scanner delivers reliable hazardous area protection with direct PROFIsafe integration. Its 5.5 m range, 190° scanning angle, and flexible field configuration make it a suitable choice for safety applications in automated industrial environments.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Mitsubishi Electric GT23 Series HMI Maintenance Guide
  • Mitsubishi GT27 HMI Application Guide
  • Siemens SIMATIC ET 200M Selection
  • Lenze 8200 Vector Selection
  • Troubleshooting of Siemens MASTER DRIVES VC
  • FANUC I/O Unit A Maintenance Manual
  • Allen Bradley PLC-5 Classic Controller Complete Guide
  • Maintenance of M&C SP2006-H/DIL Sampling Probe
  • Pro face connection to Mitsubishi DIASYS Netmation
  • OMRON SYSMAC C-series/CVM1/CV series analog I/O units
  • LTI ServoOne Replacement and Troubleshooting
  • OMRON C-series AD/DA module configuration
  • Siemens 840C 611D Module Replacement Guide
  • Diagnosis and maintenance of ABB ACS550 frequency converter fault codes
  • OMRON NX1P2 Hardware Debugging Guide
  • Fuji FRENIC Mini inverter troubleshooting
  • Braided Forissier Braided Copper Strip Selection Guide
  • Mecc Alte MC200 Controller Engineering Debugging and Troubleshooting
  • Schneider Square D 9036/9037/9038 Electromechanical Liquid Level Controller
  • Pilz PSS 4000 distributed safety control
  • Schneider TeSys GV5/GV6 Motor Circuit Breaker Operation and Protection Guide
  • Eaton Freedom NEMA Contactor Starter Complete Guide
  • OMRON D4SL-N/D4SL-NSK10-LK Safety Door Switch Comprehensive Guide
  • NI CompactRIO Embedded System
  • Emerson Ovation I/O Module Troubleshooting and Replacement Practical Guide
  • MITSUBISHI A-series PLC Troubleshooting Replacement
  • Automation Direct DL06 D0-06DD1 Replacement Guide
  • IFM CR2530 Intelligent Controller Guide
  • OMRON FH/FHV series visual sensor controller
  • Pilz PDP67 F4 code troubleshooting
  • Panasonic FP-X PLC Replacement and Troubleshooting
  • OMRON CK3W-AX Multi axis Control Selection
  • Debugging and maintenance of EPSON RC90/RC90-B controller
  • Nthytronic Group iRTUe I/O Expansion Module
  • Schneider ATV320 Inverter Installation and Debugging Guide
  • Eaton SPB Drawdown Switch Maintenance Guide
  • GFS EVO-SP dual fuel retrofit complete solution
  • OMRON CJ2 CPU Troubleshooting and Maintenance
  • Complete Guide to Lenze ECS Servo System
  • GE EX2100e Excitation System Complete Guide
  • OMRON G3PW Power Controller: Parameter Setting and Troubleshooting Guide
  • Key Points for Selection and Deployment of MITSUBISHI FX3GE PLC
  • Beckhoff EP23xx EtherCAT Box Selection Troubleshooting
  • MITSUBISHI MDS-B servo troubleshooting
  • TOYO valve pressure and temperature selection
  • SIEMENS SIMODRIVE 611 HR/HRS Replacement and Advanced Positioning Techniques
  • SIEMENS SINUMERIK 840C 611-D Startup and Troubleshooting Guide
  • FANUC Series 0i-F Maintenance and Troubleshooting
  • Troubleshooting Schneider Modicon TM3 Bus Expansion
  • Troubleshooting of R&S EPL1000
  • Baum ü llerb b maXX 5000 Safety Configuration and Troubleshooting Guide
  • Huichuan AM600 Motion Controller Malfunction and Replacement Guide
  • Allen Bradley Ultra3000 Servo Motor Replacement Guide
  • NEC NL8060BC26-17 LCD Module Maintenance and Replacement
  • ABB Pluto Safety PLC Maintenance and Troubleshooting
  • OMRON NE1A Safety Controller Troubleshooting and Replacement
  • Allen Bradley 2711P series PanelView Plus human-machine interface terminal
  • NI cFP-22xx on-site integration and troubleshooting
  • KEYENCE XG-8000 Line Scan Visual Debugging Guide
  • OMRON G9SX Security Unit Configuration and Troubleshooting
  • OMRON CPM1A Maintenance and Troubleshooting
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator