Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • SICK S30A-6111CL S3000 PROFINET Safety Laser Scanner
    ❤ Add to collection
  • SICK S30A-6111CL S3000 PROFINET Safety Laser Scanner

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥36521.00
      ¥36631.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:13.200KG
    • Quantity:
    • (Inventory: 2314)
Description
<span style="font-size: 18px; font-family: arial;">SICK S30A-6111CL S3000 PROFINET Safety Laser Scanner</span>

SICK S30A-6111CL S3000 PROFINET IO Advanced Safety Laser Scanner

The SICK S30A-6111CL (order number 1052593) is a PROFINET IO Advanced safety laser scanner from the S3000 series. Designed for industrial applications requiring reliable protection of personnel and equipment, this scanner uses optical distance measurement to monitor a 5.5 m protective field. The device integrates directly into PROFINET and PROFIsafe networks, eliminating the need for hardwired safety outputs. The S30A-6111CL is part of SICK's comprehensive safety portfolio and is suitable for stationary and mobile applications, including AGV collision avoidance and hazardous area access monitoring.

Technical Specifications

The S30A-6111CL features a sensor head with a 5.5 m protective field range and a 49 m warning field range. The scanning angle is 190°, providing wide-area coverage. Resolution is configurable from 30 mm to 150 mm, with an angular resolution of 0.5° or 0.25° depending on range. The response time is 60 ms (base response time) plus multiple sampling selection. The device includes an integrated PROFINET switch with two RJ45 ports. Communication is via PROFINET and PROFIsafe (safety profile). The scanner has no local inputs or outputs; all safety signals are transmitted via PROFIsafe. The supply voltage is 24 V DC. The device is housed in a robust enclosure suitable for indoor use. It measures approximately 185 mm × 155 mm × 160 mm and weighs 3.71 kg. The scanner features a 100 mm protective field supplement to detect objects above the scanning plane.

Key Features

  • 5.5 m protective field range (49 m warning field range)

  • 190° scanning angle for wide coverage

  • PROFINET IO (2-port switch) and PROFIsafe communication

  • No local I/O; all safety signals via PROFIsafe

  • Configurable resolution: 30, 40, 50, 70, 150 mm

  • Angular resolution: 0.5° or 0.25°

  • Up to 4 configurable field sets and 8 fields

  • Simultaneous monitoring of up to 2 protective fields

  • Integrated configuration memory

  • Restart interlock, multiple sampling, and simultaneous monitoring functions

  • Diagnostic data output via RS-422 interface

Safety Ratings and Compliance

The S30A-6111CL is certified to Type 3 (IEC 61496) with a safety integrity level of SIL2 (IEC 61508). It meets Category 3 (EN ISO 13849) with a performance level of PL d. The PFHD is 8.0 × 10⁻⁸, with a mission time of 20 years (EN ISO 13849). The device has a restart interlock, multiple sampling, and protective field switching functions. All safety-related data logic is zero for safe state.

PROFINET and PROFIsafe Integration

The S30A-6111CL integrates directly into PROFINET networks as an IO device. The two integrated Ethernet ports act as a switch, allowing daisy-chaining of multiple devices without external switches. PROFIsafe transmits safety-related data (status of protective fields, restart interlock requests, etc.) to a fail-safe PLC. The GSDML file (provided by SICK) facilitates seamless integration into TIA Portal, STEP 7, or other PROFINET-compliant engineering environments. The device supports conformance class B, RT real-time class, and MRP (Media Redundancy Protocol). It also includes SNMP, MIB-2, and LLDP for network diagnostics.


Applications

The S30A-6111CL is suitable for safety applications including stationary hazardous area monitoring, AGV (automated guided vehicle) collision avoidance, robotic cell access monitoring, and perimeter protection. The PROFINET IO interface is ideal for integration into Industry 4.0 systems, enabling real-time safety data exchange and diagnostic information.

Configuration and Diagnostics

Configuration is performed using SICK Safety Designer software. Users can define up to 4 configurable field sets and 8 fields, with the ability to switch fields dynamically during operation. The device supports both static protective field switching and simultaneous monitoring of two fields. The RS-422 interface provides measurement data output for diagnostic purposes. The integrated configuration memory stores field parameters, eliminating the need for external storage.


Installation and Maintenance

The S30A-6111CL is installed using the supplied mounting bracket (order separately). The sensor must be positioned with a clear line of sight to the protected zone. The device has a 100 mm protective field supplement to prevent undetected approaches from below the scanning plane. Clean the front window regularly for optimal performance. The device does not contain user-serviceable parts. A system plug (separate accessory) is required for power and configuration access.

Environmental and Compliance

The S30A-6111CL is CE and RoHS compliant. It is designed for indoor use only (IP65 enclosure). Operating temperature: 0°C to 50°C. Storage temperature: -25°C to 70°C. Humidity: 10-90% non-condensing. Vibration resistance: 2g (10-55 Hz).

Conclusion

The SICK S30A-6111CL S3000 PROFINET IO Advanced safety laser scanner delivers reliable hazardous area protection with direct PROFIsafe integration. Its 5.5 m range, 190° scanning angle, and flexible field configuration make it a suitable choice for safety applications in automated industrial environments.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ADLINK PCI-9112 Multi functional Data Acquisition Card
  • ADLINK PCI-8102 Two Axis Pulse Motion Control Card
  • ADLINK PCI-9812/10 high-speed synchronous acquisition card
  • ADLINK PCI-7200 High Speed Digital I/O Card
  • ADLINK MXE-1000 series fanless industrial computer
  • ADLINK IMB-T10 Mini ITX Embedded Motherboard
  • ADLINK HSL-DO32-M-N/P distributed I/O module
  • ADLINK DAQ-2500 Series Multi Channel Analog Output Card
  • ADLINK DAQ-2200 Series Data Acquisition Card
  • ADLINK ETX-AT-N270 Embedded Module
  • ADLINK ACL-7225B Relay Isolation Input Card Guide
  • ADLINK DAQ-2000 Synchronous Sampling and Acquisition Card Selection Guide
  • ADLINK NuPRO-E330 Industrial Motherboard Selection and Deployment
  • ADLINK ACL-8112 Data Acquisition Card Configuration and Programming
  • ADLINK USB-2405 Dynamic Signal Acquisition Module Deployment Guide
  • ADLINK PXIS-3320 PXI chassis installation troubleshooting
  • ADLINK PCIe-GIE72/74 Image Acquisition Card Deployment Guide
  • ADLINK PCIe-7856/7853 Sports I/O Controller Card Guide
  • ADLINK PCI-6308 Isolation Output Card Programming and Installation
  • ADLINK PCI-7432 installation and configuration troubleshooting
  • adlink nupro-e72 التحكم الصناعي اللوحة
  • ADLINK NuPRO-E72 Industrial Control Motherboard
  • ADLINK MXE-5400 Industrial Control Computer
  • ADLINK M-322 Industrial Motherboard Configuration and Deployment Guide
  • ADLINK IMB-M43H Industrial Motherboard Configuration and 6th/7th Generation Core Deployment Guide
  • ADLINK IMB-M42H Industrial Motherboard Deployment and BIOS Optimization Guide
  • ADLINK i915GV-INA motherboard configuration and ISA compatibility tuning guide
  • ADLINK ETX-NR667 Core2 Duo Module Selection and Deployment
  • ADLINK ETX-BT Module Configuration and PATA to SATA Upgrade Guide
  • ADLINK CM1-BT1 Extreme Environment Deployment and Configuration
  • ADLINK cPCI-8217 VGA/LCD Module Configuration and Troubleshooting
  • ADLINK AmITX-SL-G Mini ITX Motherboard Deployment and SEMA Guide
  • ADLINK AmITX-AL-I Embedded Motherboard Deployment and SEMA Management Guide
  • ADLINK NuPRO-E315 PICMG 1.3 Industrial Motherboard Deployment Guide
  • ADLINK NuPRO-842 Pentium 4 Industrial Motherboard Deployment and Debugging Guide
  • ADLINK NuPRO-900A Dual Xeon ePCI-X Motherboard Deployment Guide
  • ADLINK cPCI-6910 Dual Core Xeon Single Board Computer Deployment Guide
  • ADLINK cPCI-6860A Dual Xeon Single Board Computer Deployment Guide
  • ADLINK CPCI-8168 Eight Axis Motion Control Card Deployment and HSL Integration Guide
  • ADLINK NuPRO-E340 Industrial Motherboard Debugging and BIOS Optimization Guide
  • ADLINK NuPRO-A40H Industrial Single Board Computer Hardware Deployment and BIOS Calibration Guide
  • ADLINK NuPRO-852 LGA775 Industrial Control Motherboard Maintenance Guide
  • ADLINK NuPRO-841 Industrial Motherboard Maintenance and Troubleshooting
  • ADLINK NuPRO-590 Series Socket7 Industrial Control Motherboard Maintenance Guide
  • Deployment and Troubleshooting of ADLINK MXE-5500 Series Industrial Control Computer
  • ADLINK MXE-200 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK cPCI-6770 Series CompactPCI Motherboard Maintenance Guide
  • ADLINK NuPRO-A301 Industrial Motherboard Troubleshooting Manual
  • ADLINK NuPRO-965 SHB Debugging and Maintenance Complete Manual
  • ADLINK NuPRO-935A Industrial Motherboard Debugging and Maintenance Guide
  • ADLINK NuPRO-865 Single Board Computer Hardware Troubleshooting Guide
  • ADLINK NuPRO-840 P4 Industrial SBC Architecture Maintenance
  • ADLINK NuPRO-770 Full length SBC Configuration and Maintenance
  • ADLINK NuPRO-595 Industrial Half length SBC Motherboard Configuration and Maintenance Guide
  • ADLINK cPCI-6840 Series Single Board Computer Installation, Configuration, and Maintenance Guide
  • Foxboro 43AP Pneumatic Controller Technical Specifications and Selection Guide
  • ADLINK cPCI-3720: 3U CompactPCI Low Power Pentium III CPU Module
  • ADLINK NuPRO-E47: PICMG 1.3 13th Generation Core Industrial SHB
  • ADLINK NuPRO-E43: PICMG 1.3 Core 7th Generation Industrial SHB
  • ADLINK NuPRO-780 PICMG Bus Core CPU Card
  • ADLINK cPCI-6965 6U CompactPCI Core Dual Core Single Board Computer
  • ADLINK USB/LPCI/LPCIe-3488A GPIB Interface Card Selection and Application Guide
  • Rittal SK 3241.700 Blue e+Cabinet Fan Filter Unit
  • ADLINK CPCI-8168 8-Axis Motion Control Card and HSL Network Integration Solution
  • ADLINK PCIe-PXIe-8638 High Speed PXIe Bus Expansion Scheme
  • ADLINK PCIe GIE7x Poe+Frame Grabber Hardware and Power Management Detailed Explanation
  • ADLINK PCIe-7396 Digital I/O Card Deployment Guide
  • ADLINK PCI-8164 Advanced Motion Control Card Deployment Guide
  • ADLINK PCI-8154 Motion Control Card Deployment Guide
  • ADLINK PCI-8134 Motion Control Card Deployment Guide
  • ADLINK NuPRO-E42 Industrial Control Motherboard Deployment Guide
  • ADLINK MXC-6600 Embedded Platform Deployment Guide
  • ADLINK MXC-6000 Industrial Control Computer Deployment and Optimization Guide
  • ADLINK MXC-2300 Embedded System Deployment Guide
  • ADLINK MCM-204 Edge DAQ Deployment Configuration Guide
  • ADLINK MCM-100/102 Deployment Calibration Guide
  • Deployment and Performance Optimization of ADLINK MXC-6400 Industrial Control Computer
  • Selection and Deployment of ADLINK Matrix Series Industrial Control Computers
  • российские промышленные новые машины.Наш отдел дебютировал в 2026 году в России Международная промышленная ярмарка INNOPROM
  • Deeply cultivating the Eurasian industrial market, linking new industrial opportunities between China and Russia
  • Deployment and troubleshooting of ADLINK GIE64+PoE acquisition card
  • Honeywell UMS Security System Troubleshooting Guide
  • Honeywell Expert Series C I/O Troubleshooting Guide
  • ADLINK EOS-1200 Vision System Deployment and Troubleshooting
  • ADLINK DLAP-5200 series AI engine deployment and optimization
  • ADLINK DLAP-4000 Deployment and BIOS Optimization
  • ADLINK Matrix MXC-2000 Deployment and Troubleshooting
  • ADLINK DAQe-2000 series acquisition card calibration and synchronization
  • ADLINK cPCI-6520 Core i7 Processor Blade Engineering Application Guide
  • ADLINK CM1-86DX3 PC/104 Embedded Single Board Computer Engineering Application Guide
  • Honeywell DC1000 Series PID Temperature Controller Engineering Application Guide
  • ALSTOM MiCOM C264 Substation Controller Engineering Application Guide
  • EMERSON AMS 2140 Practical Guide for On site Dynamic Balance and Vibration Analysis
  • ADLINK NuPRO-E320 motherboard deployment and tuning guide
  • ADLINK NuPRO-800 Dual PIII Industrial SBC Maintenance and Upgrade Guide
  • ADLINK NuPRO-598 SBC Maintenance Practical Guide
  • ADLINK MXC-6300 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK Express-BASE7 Carrier Board Quick Deployment and Debugging Guide
  • ADLINK DLAP-211 Edge AI Platform Selection and Deployment Guide
  • ADLINK 7230 Series Isolation DIO Card Selection and Engineering Application Guide
  • ADLINK cPCI-6965 SBC Embedded Installation and BIOS Tuning Guide
  • ADLINK 7200 Series High Speed DIO Card Practical Guide
  • ADLINK DLAP Series Edge AI Acceleration Platform Selection and Deployment Practical Guide
  • DEIF TCM-2 thyristor control module: Wind power cut in control engineering guide
  • DEIF MVR-200 Medium Voltage Relay: Installation and Wiring Engineering Guide
  • DEIF MDR-2 Differential Relay: Engineering Guide for Generator Differential Protection
  • DEIF Delomatic 3 AOM: Engineering Guide for Analog Output Modules
  • DEIF AGI 400 Graphic Interface: Ship and Industrial HMI Solution
  • DEIF BRW-1 Marine Instruments: Installation and Calibration Guide for Offshore Bridge Indicators
  • DEIF AGC 200 Controller: Quick Deployment and Configuration Guide for Generator Sets
  • DEIF AGC-2 Controller: The Ultimate Guide to Automatic Control and Protection of Generator Sets
  • ABB SPA-ZC400 Gateway: REM54x Access to IEC 61850 Ultimate Engineering Guide
  • ABB REM 543/545 Terminal
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module