Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • SICK S30A-6011EA S3000 Safety Laser Scanner
    ❤ Add to collection
  • SICK S30A-6011EA S3000 Safety Laser Scanner

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥36274.00
      ¥37458.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:12.500KG
    • Quantity:
    • (Inventory: 3648)
Description
<span style="font-size: 18px; font-family: arial;">SICK S30A-6011EA S3000 Safety Laser Scanner</span>

SICK S30A-6011EA S3000 Standard Safety Laser Scanner

The SICK S30A-6011EA (order number 1023548) is an S3000 Standard safety laser scanner designed for stationary and mobile hazardous area monitoring. This device provides a protective field range of 3 meters and a warning field range of 49 meters, making it suitable for applications such as automated guided vehicle collision avoidance, machine access protection, and perimeter guarding. The scanner uses optical time-of-flight measurement to detect objects within its 190° scanning angle, generating up to four configurable field sets for flexible protection zones. Certified to Type 3 (IEC 61496) and Performance Level d (ISO 13849-1), the S30A-6011EA provides reliable safety functions for industrial machinery. The S3000 series is known for its compact design, easy configuration, and robust performance in demanding industrial environments.

Technical Specifications

The S30A-6011EA features a protective field range of 3.0 meters, with resolution configurable from 30 mm to 150 mm. The warning field range extends to 49 meters. The scanning angle is 190°, providing wide-area coverage suitable for most mobile and stationary applications. Angular resolution is 0.5° or 0.25° depending on range. The response time is 60 ms base response time, with a configurable multiple sampling function to adjust response time for increased safety. The scanner includes multiple configurable field sets: up to 4 field sets, each containing up to 8 fields for flexible zone switching. The simultaneous monitoring of up to 2 protective fields per field set is possible. Data transmission is via PROFIBUS or RS-422 serial interface. Supply voltage is 24 V DC. The device is housed in a robust IP65-rated enclosure suitable for indoor and outdoor applications. Dimensions are approximately 185 mm × 155 mm × 160 mm, with a weight of 3.71 kg. A 100 mm protective field supplement is required to prevent undetected approaches below the scanning plane.

Key Features

  • Protective field range: 3 m (w/ configurable 30-150 mm resolution)

  • Warning field range: 49 m

  • Scanning angle: 190° with 0.5° or 0.25° angular resolution

  • Type 3 / SIL2 / PL d safety rating

  • PROFIBUS and RS-422 serial data output

  • Up to 4 configurable field sets, 8 fields per set

  • Simultaneous monitoring of up to 2 protective fields

  • Restart interlock and multiple sampling safety functions

  • Configurable via SICK Safety Designer software

  • Diagnostic data output and measurement data output

Safety Functions and Configuration

The S30A-6011EA is configured using SICK Safety Designer software, which allows users to define protective and warning fields, set field switching conditions, and configure safety functions such as restart interlock and multiple sampling. Up to 4 field sets can be defined, with each set containing up to 8 fields. Field sets can be switched dynamically based on vehicle speed, direction, or machine state, allowing the scanner to adapt to changing operational conditions. The simultaneous monitoring of two protective fields per field set provides enhanced protection by allowing, for example, a near field for immediate stopping and a far field for speed reduction warnings. The restart interlock function ensures that a hazardous condition cannot restart automatically after the protective field is cleared, requiring a manual reset. The multiple sampling function adds additional samples before switching outputs, improving noise immunity at the cost of increased response time.

Applications

The S30A-6011EA is used in both stationary and mobile industrial safety applications. In stationary applications, it protects access to hazardous areas such as robotic cells, packaging machinery, and automated storage systems. In mobile applications, it is used for AGV (automated guided vehicle) and AGC (automated guided cart) collision avoidance, providing a protective field in the direction of travel and warning fields on the sides. Other applications include perimeter protection around large machinery, area monitoring of high-risk zones, and material handling systems where personnel access must be restricted during machine operation. The 49 m warning field range is particularly useful for AGV applications where early detection of obstacles allows speed reduction rather than emergency stop, improving overall system efficiency. The scanner's wide scanning angle and multiple field sets make it suitable for complex layouts and irregular shapes, such as irregularly shaped workspaces or non-rectangular machinery.


Installation and Maintenance

The S30A-6011EA is mounted using the supplied mounting bracket. Proper installation requires careful attention to the 100 mm protective field supplement: objects below the scanning plane that are less than 100 mm in height may not be detected unless additional measures (such as the use of a protective field supplement) are taken. The scanner's sensing plane must be set at a height appropriate for the application. The front window must be kept clean and free of obstructions; a dirty window may reduce detection range. The scanner includes an integrated configuration memory for storing field parameters, allowing the device to be replaced without reconfiguration. Diagnostic data output via PROFIBUS or RS-422 allows remote monitoring of scanner status, including contamination warnings. The scanner is factory-calibrated and requires no routine calibration, though periodic functional testing (as required by safety regulations) should be performed. Cleaning of the front window should be done with a soft, lint-free cloth and mild detergent.

Environmental and Compliance

The S30A-6011EA is CE certified and meets EMC requirements for industrial environments. It is Type 3 compliant with IEC 61496-1/-2, SIL2 compliant with IEC 61508, and PL d / Category 3 compliant with EN ISO 13849-1. The scanner is IP65 rated for dust and water jet protection, making it suitable for indoor and outdoor industrial applications. Operating temperature range is -10°C to +50°C, with storage from -20°C to +70°C. Humidity tolerance is 10-90% non-condensing. The device is designed for use in pollution degree 2 environments and requires a protective housing for outdoor installations if direct weather exposure is expected. The scanner's optical components are protected by an anti-reflection and anti-fog coating, ensuring reliable operation in humid conditions. The device is RoHS compliant.

Conclusion

The SICK S30A-6011EA S3000 Standard safety laser scanner provides reliable hazardous area protection for stationary and mobile applications. With its 3 m protective field, 49 m warning field, and configurable field sets, it offers flexible protection for machine guarding and AGV collision avoidance applications. The SICK Safety Designer software simplifies configuration and diagnostics, while the robust IP65 housing ensures reliable operation in demanding industrial conditions. Certified to Type 3/PL d/SIL2, it is suitable for a wide range of industrial safety applications requiring dependable object detection and area monitoring.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ADLINK AmITX-SL-G Mini ITX Motherboard Deployment and SEMA Guide
  • ADLINK AmITX-AL-I Embedded Motherboard Deployment and SEMA Management Guide
  • ADLINK NuPRO-E315 PICMG 1.3 Industrial Motherboard Deployment Guide
  • ADLINK NuPRO-842 Pentium 4 Industrial Motherboard Deployment and Debugging Guide
  • ADLINK NuPRO-900A Dual Xeon ePCI-X Motherboard Deployment Guide
  • ADLINK cPCI-6910 Dual Core Xeon Single Board Computer Deployment Guide
  • ADLINK cPCI-6860A Dual Xeon Single Board Computer Deployment Guide
  • ADLINK CPCI-8168 Eight Axis Motion Control Card Deployment and HSL Integration Guide
  • ADLINK NuPRO-E340 Industrial Motherboard Debugging and BIOS Optimization Guide
  • ADLINK NuPRO-A40H Industrial Single Board Computer Hardware Deployment and BIOS Calibration Guide
  • ADLINK NuPRO-852 LGA775 Industrial Control Motherboard Maintenance Guide
  • ADLINK NuPRO-841 Industrial Motherboard Maintenance and Troubleshooting
  • ADLINK NuPRO-590 Series Socket7 Industrial Control Motherboard Maintenance Guide
  • Deployment and Troubleshooting of ADLINK MXE-5500 Series Industrial Control Computer
  • ADLINK MXE-200 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK cPCI-6770 Series CompactPCI Motherboard Maintenance Guide
  • ADLINK NuPRO-A301 Industrial Motherboard Troubleshooting Manual
  • ADLINK NuPRO-965 SHB Debugging and Maintenance Complete Manual
  • ADLINK NuPRO-935A Industrial Motherboard Debugging and Maintenance Guide
  • ADLINK NuPRO-865 Single Board Computer Hardware Troubleshooting Guide
  • ADLINK NuPRO-840 P4 Industrial SBC Architecture Maintenance
  • ADLINK NuPRO-770 Full length SBC Configuration and Maintenance
  • ADLINK NuPRO-595 Industrial Half length SBC Motherboard Configuration and Maintenance Guide
  • ADLINK cPCI-6840 Series Single Board Computer Installation, Configuration, and Maintenance Guide
  • Foxboro 43AP Pneumatic Controller Technical Specifications and Selection Guide
  • ADLINK cPCI-3720: 3U CompactPCI Low Power Pentium III CPU Module
  • ADLINK NuPRO-E47: PICMG 1.3 13th Generation Core Industrial SHB
  • ADLINK NuPRO-E43: PICMG 1.3 Core 7th Generation Industrial SHB
  • ADLINK NuPRO-780 PICMG Bus Core CPU Card
  • ADLINK cPCI-6965 6U CompactPCI Core Dual Core Single Board Computer
  • ADLINK USB/LPCI/LPCIe-3488A GPIB Interface Card Selection and Application Guide
  • Rittal SK 3241.700 Blue e+Cabinet Fan Filter Unit
  • ADLINK CPCI-8168 8-Axis Motion Control Card and HSL Network Integration Solution
  • ADLINK PCIe-PXIe-8638 High Speed PXIe Bus Expansion Scheme
  • ADLINK PCIe GIE7x Poe+Frame Grabber Hardware and Power Management Detailed Explanation
  • ADLINK PCIe-7396 Digital I/O Card Deployment Guide
  • ADLINK PCI-8164 Advanced Motion Control Card Deployment Guide
  • ADLINK PCI-8154 Motion Control Card Deployment Guide
  • ADLINK PCI-8134 Motion Control Card Deployment Guide
  • ADLINK NuPRO-E42 Industrial Control Motherboard Deployment Guide
  • ADLINK MXC-6600 Embedded Platform Deployment Guide
  • ADLINK MXC-6000 Industrial Control Computer Deployment and Optimization Guide
  • ADLINK MXC-2300 Embedded System Deployment Guide
  • ADLINK MCM-204 Edge DAQ Deployment Configuration Guide
  • ADLINK MCM-100/102 Deployment Calibration Guide
  • Deployment and Performance Optimization of ADLINK MXC-6400 Industrial Control Computer
  • Selection and Deployment of ADLINK Matrix Series Industrial Control Computers
  • российские промышленные новые машины.Наш отдел дебютировал в 2026 году в России Международная промышленная ярмарка INNOPROM
  • Deeply cultivating the Eurasian industrial market, linking new industrial opportunities between China and Russia
  • Deployment and troubleshooting of ADLINK GIE64+PoE acquisition card
  • Honeywell UMS Security System Troubleshooting Guide
  • Honeywell Expert Series C I/O Troubleshooting Guide
  • ADLINK EOS-1200 Vision System Deployment and Troubleshooting
  • ADLINK DLAP-5200 series AI engine deployment and optimization
  • ADLINK DLAP-4000 Deployment and BIOS Optimization
  • ADLINK Matrix MXC-2000 Deployment and Troubleshooting
  • ADLINK DAQe-2000 series acquisition card calibration and synchronization
  • ADLINK cPCI-6520 Core i7 Processor Blade Engineering Application Guide
  • ADLINK CM1-86DX3 PC/104 Embedded Single Board Computer Engineering Application Guide
  • Honeywell DC1000 Series PID Temperature Controller Engineering Application Guide
  • ALSTOM MiCOM C264 Substation Controller Engineering Application Guide
  • EMERSON AMS 2140 Practical Guide for On site Dynamic Balance and Vibration Analysis
  • ADLINK NuPRO-E320 motherboard deployment and tuning guide
  • ADLINK NuPRO-800 Dual PIII Industrial SBC Maintenance and Upgrade Guide
  • ADLINK NuPRO-598 SBC Maintenance Practical Guide
  • ADLINK MXC-6300 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK Express-BASE7 Carrier Board Quick Deployment and Debugging Guide
  • ADLINK DLAP-211 Edge AI Platform Selection and Deployment Guide
  • ADLINK 7230 Series Isolation DIO Card Selection and Engineering Application Guide
  • ADLINK cPCI-6965 SBC Embedded Installation and BIOS Tuning Guide
  • ADLINK 7200 Series High Speed DIO Card Practical Guide
  • ADLINK DLAP Series Edge AI Acceleration Platform Selection and Deployment Practical Guide
  • DEIF TCM-2 thyristor control module: Wind power cut in control engineering guide
  • DEIF MVR-200 Medium Voltage Relay: Installation and Wiring Engineering Guide
  • DEIF MDR-2 Differential Relay: Engineering Guide for Generator Differential Protection
  • DEIF Delomatic 3 AOM: Engineering Guide for Analog Output Modules
  • DEIF AGI 400 Graphic Interface: Ship and Industrial HMI Solution
  • DEIF BRW-1 Marine Instruments: Installation and Calibration Guide for Offshore Bridge Indicators
  • DEIF AGC 200 Controller: Quick Deployment and Configuration Guide for Generator Sets
  • DEIF AGC-2 Controller: The Ultimate Guide to Automatic Control and Protection of Generator Sets
  • ABB SPA-ZC400 Gateway: REM54x Access to IEC 61850 Ultimate Engineering Guide
  • ABB REM 543/545 Terminal
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection