Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

TEKTRONIX AFG31000 series arbitrary function generator

来源: | 作者:FAN | 发布时间 :2025-11-20 | 243 次浏览: | Share:

TEKTRONIX AFG31000 series arbitrary function generator

Product model and core parameters

1. Comparison Table of Model Parameters

Model, bandwidth, sampling rate, number of channels, standard memory, optional memory, pulse generator, bandwidth

AFG31021 25MHz 250MS/s 1 16MS/CH 128MS/CH 20MHz

AFG31022 25MHz 250MS/s 2 16MS/CH 128MS/CH 20MHz

AFG31051 50MHz 1GS/s 1 16MS/CH 128MS/CH 40MHz

AFG31052 50MHz 1GS/s 2 16MS/CH 128MS/CH 40MHz

AFG31101 100MHz 1GS/s 1 16MS/CH 128MS/CH 80MHz

AFG31102 100MHz 1GS/s 2 16MS/CH 128MS/CH 80MHz

AFG31151 150MHz 2GS/s 1 16MS/CH 128MS/CH 120MHz

AFG31152 150MHz 2GS/s 2 16MS/CH 128MS/CH 120MHz

AFG31251 250MHz 2GS/s 1 16MS/CH 128MS/CH 160MHz

AFG31252 250MHz 2GS/s 2 16MS/CH 128MS/CH 160MHz

2. General technical characteristics

Vertical resolution: 14 bits, ensuring waveform accuracy.

Output impedance: default 50 Ω, can be set to 1 Ω~10k Ω (resolution 1 Ω) or Infinity (>10k Ω).

Modulation types: Supports AM (amplitude modulation), FM (frequency modulation), PM (phase modulation), FSK (frequency shift keying), PWM (pulse width modulation).

Environmental adaptability: working temperature of 0 ℃~40 ℃, humidity of 5%~85% RH, working altitude of 3000m.


Safety regulations and operating taboos

1. Core security principles

Only for professional operation: Only personnel with high voltage/high frequency testing qualifications are allowed to operate, and non professionals are prohibited from contacting.

System level security: If connecting to a large system, it is necessary to comply with the security manuals of other components of the system.

Preoperative examination: Before use, verify that the device is functioning properly with a known signal source and prohibit its use for detecting dangerous voltages.

2. Key operations for preventing electric shock and fire prevention

(1) Power supply and grounding

Use designated power cords (must comply with local certification), and do not mix power cords from other devices.

The equipment is grounded through the power cord, and the grounding conductor must be connected to the ground. It is forbidden to disconnect the grounding connection.

Confirm that the power supply voltage matches the rated value of the equipment (such as 100V~240V AC) before powering on.

(2) Connection/disconnection sequence

Operation type, step purpose

Connect circuit 1. Connect the probe output to the measuring instrument → 2 Connect the probe reference terminal to the tested circuit → 3 Connect the probe input to avoid electric shock or equipment damage caused by live plugging and unplugging

Disconnect circuit 1. Disconnect probe input and reference terminal → 2 Disconnect the probe from the instrument to prevent residual voltage shock

(3) Taboos on Environment and Equipment Status

Do not use in damp, explosive, and dusty environments, and do not operate without cover plates/panels (exposing high-voltage circuits).

If the equipment falls, gets wet, or is suspected of damage, authorized personnel must inspect it before use, and it is prohibited to disassemble it by oneself.

Do not touch the exposed circuit when powered on, and keep the probe body and output line away from the tested circuit.

image.png

Remote control interface and instruction system

1. Interface configuration

(1) GPIB interface

Requirements:

Each device must have a unique address (1-30) and must not be duplicated;

The bus can connect up to 15 devices, with a total cable length of ≤ 20m and at least 1 device per 2m;

Power on devices account for ≥ 67%, support star/linear topology, and prohibit parallel/ring topology.

Address setting: Enter the address through the panel "Utility → I/O Interface → GPIB Address" (* RST command cannot initialize the address).

(2) VISA interface

TekVISA software (official website download) needs to be installed, supporting GPIB, RS-232, Ethernet remote control, and complying with VISA 2.2 standard.

Applicable development environment: Windows system, supporting ADE (Application Development Environment) such as LabVIEW and VB.

2. Instruction system and syntax

(1) Instruction classification

Example Function of Instruction Type

IEEE 488.2 General Command * CAL? 、 *CLS, * RST self calibration, clear register, reset

SCPI command SOURce1: FUNCTION SIN, OUTPut1: STATe ON. Set the waveform of channel 1 to sine and enable the output of channel 1

(2) Core Grammar Rules

Abbreviation: Commands can be abbreviated (uppercase is required, lowercase can be omitted), such as DISPlay: BRIGhtness can be abbreviated as DISP: BRIG.

Chain command: Multiple commands are separated by semicolons, and prefixes can be omitted for the same root node, such as TRIGger: CLOPe POS; SOURce SIN (assuming the trigger slope is positive and the source waveform is sine).

SI units: support voltage (V/mV), frequency (Hz/kHz/MHz), time (s/ms/μ s/ns), etc., such as Frequency 10MHz (assuming frequency 10MHz).

Parameter type: Supports Boolean values (ON/OFF), numerical values (NR1/NR2/NR3), and strings (quotation marks required), such as MMEMory: DELete "U:/TEST. TFWX" (remove the TEST. TFWX file from USB).


Detailed explanation of core functions and instructions

1. Waveform generation and output control

  • BENTLY 1-536067-4 Proximitor Connector Lead
  • BENTLY 3500/34 125696-01 TMR Relay Module
  • BENTLY 125704-01 3500/32M I/O Module
  • BENTLY 126632-01 Keyphasor I/O Module
  • BENTLY 3500/25 125792-01 Keyphasor Module
  • Bently Nevada 2300/25-00 Vibration Monitor
  • Bently Nevada 3500/05-01-03-00-00-00 Rack
  • Bently Nevada 3500/42M 140734-02 Monitor
  • Bently Nevada 123M4610 Accelerometer
  • Bently Nevada 3500/05-02-04-00-00-00 Rack
  • Bently Nevada 3500/53 133388-01 Overspeed Detection Module
  • Bently Nevada 3500/32 125712-01 Relay Module for Machinery Protection
  • Bently Nevada 3500/20 125744-02 Rack Interface Module
  • Bently Nevada 3500/40M 140734-01 Proximitor Monitor Module
  • Bently Nevada 3500/60 163179-01 Temperature Monitor Module
  • BENTLY 3500/22M 288055-01 Enhanced TDI Module
  • BENTLY 3500/22M 146031-01 TDI Module
  • BENTLY 133396-01 3500/22M I/O Module
  • BENTLY 3500/34 TMR RMS Interface Module
  • BENTLY 128275-01-E Proximitor I/O Module
  • Bently Nevada 128276-011 Proximity Probe
  • Bently Nevada 135489-03 Accelerometer
  • Bently Nevada 135473-01 Seismic Transducer
  • Bently Nevada 1900/55 General Purpose Monitor
  • Bently Nevada ASSY78462-01U Proximitor Assembly
  • Bently Nevada 330100-90-01 Proximity Probe for Vibration Monitoring
  • Bently Nevada 330100-90-00 Proximity Probe for Machinery Monitoring
  • Bently Nevada 132419-01 Proximitor Sensor for Vibration Monitoring
  • Bently Nevada 10244-27-50-01 Proximity Probe Extension Cable
  • Bently Nevada 22810-01-05-50-02 Proximity Probe System
  • BENTLY 330980-51-00 3300 NSv Proximitor Sensor
  • BENTLY 330130-045-00-00 3300 XL Extension Cable
  • BENTLY 1X35668 Replacement Internal Module
  • BENTLY 3300/16 Dual XY Vibration Monitor
  • BENTLY 3500/15 133292-01 High Availability Power Supply
  • Bently Nevada 3500/62 163179-03 Process Monitor
  • Allen-Bradley 80190-100-01-R*3 Output Module
  • Allen-Bradley 80190-099-01 Analog Module
  • Allen-Bradley 80190-479-01 I/O Module
  • Allen-Bradley 80190-480-01-R Control Module
  • Bently 3500/15 125840-01 Power Supply Module
  • Bently 24765-02-01 Signal Conditioner Module
  • Bently 330130-085-00-00 Extension Cable
  • Bently 3500/22M 138607-01 Vibration Monitor Module
  • Bently 146031-02 Proximity Probe Sensor
  • BENTLY 330104-00-05-10-02-CN Proximity Probe
  • BENTLY 125768-01 3500 I/O Module Interface
  • BENTLY 3500/92 136180-01 Communication Gateway
  • BENTLY 84152-01 Proximitor Sensor Cable
  • BENTLY 3300/20 Dual Driver Proximitor Housing
  • BENTLY 3300/16-11-01-03-00-00-01 16-Channel Monitor
  • DEIF PPU-3 Power Protection Unit for Genset Control
  • DEIF RMV-112D Reactive Power Divider and Voltage Matching Relay
  • DEIF OPM-1 Output Protection Module for Gensets
  • DEIF IPM-1 Integrated Protection Module for Generators
  • DEIF CM-2 Control Module for Industrial Power Systems
  • DEIF PSM-1 Power System Manager Module
  • DEIF DELOMATIC-3 DGU2 Automatic Generator Control Unit
  • DEIF DLQ144-PC-NB Power Monitoring Meter
  • DEIF DU-2/MKIII Voltage Relay Controller
  • DEIF IOM4.2 Input/Output Module for Power Management
  • DEIF SCM-1 Synchronizing Control Module
  • DEIF GPU/2/GS Genset Parallel Unit Controller
  • EMERSON PR6426/010-110 CON021 Proximity System
  • EMERSON PR6423/011-110+C0N021 Proximity Sensor System
  • DEIF LSU-112DG Load Sharing Unit
  • DEIF PCM4.4 Advanced Power Control Module
  • DEIF TAC-311DG Transducer for AC Voltage
  • DEIF SCM4.1 Engine Start Control Module
  • DEIF PCM4.3 Power Control Module
  • Emerson 2500M/AI4UNIV Universal Analog Input Module
  • Emerson PR6424/011-140 Eddy Current Sensor
  • Emerson KJ3242X1-BK1 12P4711X042 Analog Input Module
  • Emerson FX-316 960132-01 Control Processor Module
  • Emerson KJ4006X1-BD1 Power Supply Module
  • EMERSON 1C31181G01 Ovation Analog Output Module
  • EMERSON CE4003S2B6 DeltaV Analog Module
  • EMERSON KJ4001X1-CK1 DeltaV I/O Carrier Card
  • EMERSON VE4012S2B1 DeltaV I/O Module Specifications
  • EMERSON SS6501T01 DeltaV System Assembly Technical Overview
  • Emerson A6370D/DP Display
  • Emerson P188.R2 Power Supply
  • Emerson A6824R 24-Ch Relay
  • Emerson KJ2201X1-JA1 Serial
  • Emerson VE3008 Main Controller
  • Emerson VE3008 CE3008 KJ2005X1-MQ1 Controller Module
  • Emerson TPMC917 Embedded Processor Module
  • Emerson P152.R4 Industrial Control Module
  • Emerson DA7281520 P152 Power Module
  • Emerson PR6423/008-110 Eddy Current Sensor
  • EMERSON 5X00273G01 Ovation DCS Digital Output Module
  • EMERSON KJ4001X1-NB1 12P3368X012 REV:E Redundant Controller Backplane
  • EMERSON KJ4001X1-NA1 12P3373X012 REV:C Intrinsically Safe Interface
  • EMERSON KJ4001X1-BE1 12P0818X072 REV:L DeltaV I/O Carrier
  • EMERSON KJ2221X1-BA1 DeltaV SIS SISNet Repeater Module
  • EMERSON PR6423/000-131 Eddy Current Sensor
  • EMERSON 5X00790G01 Ovation Digital Output Module
  • EMERSON 5X00846G01 Ovation Analog Input Module
  • EMERSON KJ4110X1-BA1 DeltaV Power Supply Base
  • EMERSON CSI3125 A3125/022-020 Dual Channel Monitor
  • EMERSON A6740 Displacement Case Expansion Monitor
  • EMERSON A6312/06 Speed Monitoring Module
  • EMERSON KJ4001X1-BE1 DeltaV Carrier Module
  • EMERSON SE3008 KJ2005X1-MQ2 DeltaV Controller
  • EMERSON KJ4001X1-CA1 DeltaV Terminal Block
  • Emerson PR6423/00R-010 CON031 Eddy Current Probe System
  • Emerson A6824 9199-00090 Operator Workstation
  • Emerson A6410 9199-00005 Operator Workstation
  • Emerson A6110 9199-00001 Operator Workstation
  • Emerson 9199-00002 A6120 Operator Workstation
  • Emerson KJ3002X1-BF1 12P1732X042 FIELDVUE DVC6200
  • Emerson 5X00500G01 Ovation Analog Output Module
  • Emerson VE4001S2T2B4 DeltaV Controller Module
  • Emerson 5X00502G01 Ovation Analog Input Module
  • Emerson A6824R 9199-00098-13 Operator Workstation
  • EMERSON A6140 9199-00058 Dual Channel Monitor
  • EMERSON VE3007 KJ2005X1-BA1 DeltaV Controller
  • EMERSON DB1-1 Connection Termination Block
  • EMERSON PMC-IO-ADAPTER Mezzanine Interface Card
  • EMERSON L0115012 L0115032 Solenoid Valve Components
  • Emerson A6410 Large Operator Workstation
  • Emerson A6210 Operator Workstation
  • Emerson 1C31232G02 Ovation Controller Module
  • Emerson 5X00106G02 Ovation Power Supply Module
  • Emerson 5X00106G01 Ovation Power Supply Module
  • EMERSON PMC-IO-PROZESSOR High-Speed I/O Module
  • EMERSON PMC PROFINET Communication Module
  • EMERSON MVME7100-0171 VMEbus Single Board Computer