Selection and Configuration of Bonfiglioli Active Series Inverter
F:
|
Au:FANS
|
DA:2026-09-04
|
46 Br:
|
🔊 点击朗读正文
❚❚
▶
|
Share:
In the field of industrial automation, the selection and system integration of frequency converters directly affect equipment performance, energy efficiency, and long-term operation and maintenance costs. The Bonfiglioli Active series (ACT 210/410), as a one-stop drive solution for mid to high performance applications, has become the preferred component for industries such as packaging, material handling, textiles, and lifting machinery due to its wide power coverage, flexible modular architecture, and rigorous compliance design. This article is based on the technical core of this series, providing an engineering level application guide from hardware selection, installation adaptation, peripheral filtering, braking energy consumption to extended communication.
Suggested selection steps:
Confirm the main power supply voltage (230V or 400V) and number of phases.
According to the rated current and overload requirements of the motor, refer to the technical data sheet to select the power level (if the rated current needs to be greater than the motor current and the overload current meets the starting peak).
Determine the installation method (air-cooled/cold plate/liquid cooled) and mechanical dimensions.
Evaluate whether it is necessary to have built-in EMC filtering and braking transistors.
Select communication modules according to the fieldbus protocol and expansion modules according to the number of I/O points.
Peripheral configuration: reactors, filters, braking resistors, and ensure cable shielding and grounding standards.