Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Bonfiglioli ISMET LCVT050 DK308/50 Line Reactor
    ❤ Add to collection
  • Bonfiglioli ISMET LCVT050 DK308/50 Line Reactor

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥17548.00
      ¥18845.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:1.630KG
    • Quantity:
    • (Inventory: 67)
Description
<span style="font-size: 18px; font-family: arial;">Bonfiglioli ISMET LCVT050 DK308/50 Line Reactor</span>

Bonfiglioli ISMET LCVT050 DK308/50 Line Reactor

The Bonfiglioli ISMET LCVT050 DK308/50 Line Reactor is a mains choke intended for compatible Vectron drive input circuits. It is identified by the model LCVT050 DK308/50 and the reference ds184420050. The German term Netzdrossel is used in technical documentation to describe a mains choke or line reactor, and this helps explain the role of the unit in a drive installation. The reactor is placed on the supply side of a frequency inverter to add impedance between the mains and the drive input.

A line reactor is not a standalone power conversion device. It works with the drive, the input protection, the cabling, and the surrounding cabinet design. Its performance depends on correct selection, wiring, grounding, cooling, and coordination with other input side components. The LCVT050 DK308/50 should therefore be integrated as part of a complete drive system rather than treated as an accessory added without documentation.

Role in Drive Input Circuits

The LCVT050 DK308/50 is intended for compatible drive systems where input side impedance is required. A line reactor adds inductance in series with the supply, which can help limit current peaks and reduce the severity of harmonic currents drawn by the drive rectifier. It can also help reduce the effect of supply transients and improve the waveform seen by the drive input. The exact benefit depends on the mains impedance, the drive rating, the load profile, and the presence of other harmonic sources.

The reactor should not be confused with an EMC filter. An EMC filter is mainly intended to control high frequency emissions, while a line reactor mainly addresses low frequency current shaping and input impedance. In many installations both devices are used, and their order and wiring should follow the system design. The user should confirm the rated current, inductance, voltage class, and frequency against the project documentation before installation.

Model Identification and Compatibility

The model LCVT050 DK308/50 and the reference ds184420050 should be checked against the project bill of materials. The complete identification helps confirm that the reactor matches the drive input circuit. Similar reactors can differ in rated current, inductance, insulation class, temperature rise, and mounting arrangement, so a visual check alone is not sufficient.

Compatibility includes the supply voltage, frequency, drive input current, terminal arrangement, and cabinet space. The user should confirm that the reactor is suitable for the intended Vectron drive configuration. If the reactor is added to an existing system, the input protection and cable sizing should be reviewed together with the reactor data. A unit that fits mechanically may still be unsuitable for the electrical duty.

Electrical Installation

The reactor should be installed on the supply side of the drive according to the connection diagram. Power should be removed and the drive should be allowed to discharge before work begins. The input terminals should be connected firmly and checked against the phase markings. Cable sizes should be selected for the input current and for the installation method. The terminals should be tightened to the values defined for the installation.

Input protection such as fuses or circuit breakers should be coordinated with the drive and the reactor. The reactor should not be bypassed unless the system design allows it. If a contactor or input filter is used, the wiring sequence should follow the cabinet drawing. Loose strands, damaged insulation, and incorrect terminal assignment should be corrected before power is applied.

Wiring and Grounding Practice

Input power cables should be routed away from control and signal cables where possible. The reactor should be bonded to the cabinet reference according to the EMC plan. The protective earth connection should be made to the reactor frame or the designated terminal. If the reactor has a core or screen connection point, it should be connected as defined by the installation design.

Grounding should be consistent with the drive system. Poor bonding can reduce the effectiveness of the input side arrangement and can contribute to noise problems. The user should avoid creating unnecessary earth loops. Cable shields should be terminated according to the system design. After wiring, a visual inspection should confirm that all connections are secure and that no foreign objects remain inside the cabinet.


Thermal and Acoustic Considerations

A line reactor produces losses and therefore heat during operation. The installation should provide sufficient ventilation and clearance. The reactor should not be covered by materials that prevent heat dissipation. It should be mounted away from temperature sensitive components and should not be placed on flammable surfaces. Cabinet thermal calculations should include the reactor losses in addition to the drive losses.

Magnetic components can produce acoustic noise. A low hum is normal in many installations, but a sudden increase in noise may indicate loose laminations, a loose mounting, or a change in harmonic content. Mounting fasteners should be checked and the reactor should be installed on a stable surface. If the application includes high ambient temperature, the thermal margin should be reviewed.

Commissioning

Commissioning should begin with a visual inspection and a check of the input wiring. The reactor terminals, protective earth, and cable routing should be confirmed. The drive input protection should be checked. The user should verify that the reactor is appropriate for the drive rating and that no bypass or incorrect connection has been made.

During first operation, the input current, noise, and temperature should be observed. The readings should be recorded as a baseline for future maintenance. If the drive shows input side faults, the reactor connections, supply quality, and protection settings should be reviewed. The reactor should not be removed from the circuit to hide a symptom without understanding the cause.

Diagnostics and Troubleshooting

If the reactor overheats, the user should review the load, ambient temperature, ventilation, terminal tightness, and harmonic conditions. A loose terminal can cause local heating and should be corrected. If the reactor is noisy, the mounting and lamination condition should be checked. If the drive trips on input side faults, the supply and protection should be reviewed together with the reactor wiring.

The reactor should not be opened or modified. Replacement should be considered only after the cause has been investigated. A replacement unit should match the model reference and the electrical data. The maintenance record should include the reference, installation date, observed temperatures, and any corrective action.

Maintenance

Routine maintenance should include inspection of terminals, mounting, ventilation, and cable condition. Dust accumulation should be removed according to site policy. The reactor should be isolated and allowed to cool before work. The protective earth connection should be checked. Any discoloration, odor, or loose lamination should be investigated.

Configuration and installation records should include the model, reference, drive type, and input protection details. These records help when replacing a reactor or reviewing the drive input arrangement. Maintenance work should be performed by qualified personnel and with the system in a safe state.

Application Value

The LCVT050 DK308/50 supports input side impedance in compatible Vectron drive systems. It can help reduce current peaks, support harmonic limitation, and protect the drive input rectifier in appropriate installations. The actual benefit depends on the mains characteristics, the drive configuration, and the overall cabinet design. When selected and installed correctly, the reactor contributes to a more stable drive input circuit.

Summary

The Bonfiglioli ISMET LCVT050 DK308/50 Line Reactor reference ds184420050 is a mains choke intended for compatible drive input circuits. Correct model verification, electrical installation, grounding, thermal planning, commissioning, diagnostics, and maintenance are essential. A systematic approach supports reliable operation and helps maintain power quality in industrial drive systems.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection
  • BENDER RCMA475LY Residual Current Monitoring
  • BENDER IRDH575 Insulation Monitoring
  • BENDER IRDH265 Insulation Monitoring and Debugging
  • Bender RCMA475LY residual current monitor debugging
  • Beckwith Electric M-3425A Generator Protection Relay Debugging Guide
  • Automated MEX816U Expander Troubleshooting Guide
  • ASEM HT2150 Industrial Tablet Selection and Troubleshooting
  • Troubleshooting and practical application of Advantest U3771/3772 microwave spectrum analyzer
  • Advantest R6144 Programmable DC Voltage/Current Source (Calibration Source) Calibration and Maintenance
  • Aerotech UNIDEX 100/U100i single axis motion controller
  • Aerotech Ndrive MP Ultra Compact PWM Digital Servo Driver
  • Aerotech Ndrive HPe 10/20/30 High Performance PWM Digital Servo Drive
  • Aerotech Ndrive HLe maintenance replacement
  • Aerotech Ndrive CP maintenance replacement
  • Aerotech Ndrive Linear Drive Selection
  • Aerotech NDrive HL linear drive maintenance replacement
  • Aerotech NDrive HP 10/20/30 Maintenance and Replacement
  • Aerotech NDrive CP10 Servo Drive Guide
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting