Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Bonfiglioli Trasmital KYB MHKAYABAKTMAGA050VP34 Hydraulic Track Drive
    ❤ Add to collection
  • Bonfiglioli Trasmital KYB MHKAYABAKTMAGA050VP34 Hydraulic Track Drive

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥15296.00
      ¥17342.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:1.850KG
    • Quantity:
    • (Inventory: 63)
Description
<span style="font-size: 18px; font-family: arial;">Bonfiglioli Trasmital KYB Track Drive Motor</span>

Bonfiglioli Trasmital KYB MHKAYABAKTMAGA050VP34 Hydraulic Track Drive

Product Overview

The Bonfiglioli Trasmital KYB MHKAYABAKTMAGA050VP34 is a hydraulic track drive gear motor intended for tracked machinery. It combines a hydraulic motor with a planetary gear reduction and a track drive interface. The unit is used to convert hydraulic flow and pressure into controlled rotary motion at the track sprocket. Trasmital is the Bonfiglioli brand associated with planetary and special drives for mobile machinery.

The track drive is used in excavators, crawler carriers, drilling rigs, and other tracked equipment. Correct selection depends on traction force, track speed, hydraulic pressure, flow, duty cycle, and mounting interface. The unit should be integrated by qualified personnel who understand hydraulic systems, mechanical alignment, and mobile machine safety.

Construction and Mechanical Design

The drive unit contains a hydraulic motor, a multi-stage planetary gearbox, bearings, seals, and a mounting interface for the track sprocket. The planetary stages provide high torque density and compact dimensions. The housing supports the bearing arrangement and protects internal parts. Seals retain lubricant and prevent hydraulic fluid ingress where applicable. The output interface must match the track frame and sprocket.

Installation requires a clean and rigid mounting surface. The unit should align with the track frame and sprocket. Fasteners must be tightened to the specified torque. Hydraulic hoses should be routed without sharp bends or strain. The drain line and case pressure should be considered. Guards and covers should protect the unit from debris and impact.

Hydraulic Integration

The hydraulic circuit must provide the required pressure and flow for the drive. Relief valves, flushing, filtration, and cooling should be designed for the application. Contamination control is important for hydraulic motor life. The fluid type and viscosity must match the operating temperature range. Hoses and fittings should be rated for the system pressure.

Air should be removed from the hydraulic circuit before operation. The case drain should be connected correctly. Pressure and flow settings should be verified. The machine should be tested at low speed and low load. Hydraulic oil temperature should be monitored. Leaks should be corrected before full duty.

Installation and Commissioning

Before installation, the drive unit should be inspected for damage and the identification details checked. The mounting surface and output interface should be clean. The track frame should be checked for alignment. Hydraulic connections should be made according to the circuit diagram. The unit should be filled or connected according to the lubricant and hydraulic requirements. Guards should be fitted.

Commissioning should begin with low-speed operation. Rotation direction, noise, vibration, leakage, and temperature should be checked. Track tension and alignment should be verified. Hydraulic pressure and flow should be within specification. Fasteners should be rechecked after initial operation. Full load should be applied only after the drive and hydraulic system have been verified.


Operation and Monitoring

During operation, the track drive should run smoothly within the designed pressure, flow, and torque range. Operators should monitor hydraulic temperature, pressure, noise, vibration, and leakage. Abnormal conditions can indicate contamination, wear, misalignment, or overload. The unit should be kept clean and protected from debris buildup.

Load changes can affect drive life. Higher traction force, frequent reversing, or shock loading should be reviewed against the original selection. Hydraulic settings should not be changed without authorization. Protective devices should remain active. Fault causes should be corrected before restarting.

Protection and Reliability

Reliability depends on correct hydraulic integration, contamination control, alignment, and protection from impact. Seals should be inspected for leakage. Hydraulic filters should be maintained. The case drain should remain unobstructed. Excessive pressure or temperature should be corrected. The unit should not be operated beyond its rated conditions.

Overload protection should be coordinated with the machine and hydraulic system. Relief valve settings should be correct. Mechanical stops and track tension should be maintained. Service work should be performed by qualified personnel. Opening the unit without proper instructions can affect sealing and bearing adjustment.

Maintenance and Service

Maintenance should include periodic inspection of hydraulic connections, seals, mounting fasteners, and running behavior. Hydraulic oil condition should be checked according to the maintenance plan. Filters should be replaced as specified. The track frame and sprocket should be inspected for wear. Leakage should be corrected promptly.

Before service, the hydraulic system must be depressurized and the machine secured. The drive unit should be supported before removal. Replacement of seals or bearings requires proper tools and clean conditions. After service, hydraulic connections, alignment, and rotation should be checked. The machine should be tested at low load before full duty.

Integration and Selection Summary

The Trasmital KYB MHKAYABAKTMAGA050VP34 track drive can be integrated into tracked machinery that requires compact hydraulic drive. The final application determines traction force, speed, pressure, flow, and mounting. The unit should be selected as part of the complete hydraulic and mechanical drive system.

Selection should confirm the model reference, displacement, gear ratio, output torque, mounting interface, hydraulic ratings, and lubrication requirements. The designer should verify compatibility with the track frame and hydraulic circuit. Documentation should be reviewed before installation. Any special environment or duty cycle should be considered.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection
  • BENDER RCMA475LY Residual Current Monitoring
  • BENDER IRDH575 Insulation Monitoring
  • BENDER IRDH265 Insulation Monitoring and Debugging
  • Bender RCMA475LY residual current monitor debugging
  • Beckwith Electric M-3425A Generator Protection Relay Debugging Guide
  • Automated MEX816U Expander Troubleshooting Guide
  • ASEM HT2150 Industrial Tablet Selection and Troubleshooting
  • Troubleshooting and practical application of Advantest U3771/3772 microwave spectrum analyzer
  • Advantest R6144 Programmable DC Voltage/Current Source (Calibration Source) Calibration and Maintenance
  • Aerotech UNIDEX 100/U100i single axis motion controller
  • Aerotech Ndrive MP Ultra Compact PWM Digital Servo Driver
  • Aerotech Ndrive HPe 10/20/30 High Performance PWM Digital Servo Drive
  • Aerotech Ndrive HLe maintenance replacement
  • Aerotech Ndrive CP maintenance replacement
  • Aerotech Ndrive Linear Drive Selection
  • Aerotech NDrive HL linear drive maintenance replacement
  • Aerotech NDrive HP 10/20/30 Maintenance and Replacement
  • Aerotech NDrive CP10 Servo Drive Guide
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting