Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Bonfiglioli BMD 118 14 3000 400 165 24 K 67 TC1 Drive
    ❤ Add to collection
  • Bonfiglioli BMD 118 14 3000 400 165 24 K 67 TC1 Drive

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥16349.00
      ¥17745.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.160KG
    • Quantity:
    • (Inventory: 78)
Description
<span style="font-size: 18px; font-family: arial;">Bonfiglioli BMD 118 14 3000 400 165 24 K 67 TC1 Drive</span>

Bonfiglioli BMD 118 14 3000 400 165 24 K 67 TC1 Drive Unit

The Bonfiglioli BMD 118 14 3000 400 165 24 K 67 TC1 Drive Unit is an industrial drive assembly intended for compatible machinery. It is identified by the model BMD 118 14 3000 400 165 24 K 67 TC1 and the reference JB00004871. The unit is used to transmit controlled motion to a machine and should be integrated according to the application requirements and product documentation.

A drive assembly is part of a mechanical and electrical power train. Its performance depends on correct selection, mounting, shaft alignment, electrical connection, and load matching. The BMD unit should be integrated with attention to the machine interface, output shaft connection, mounting position, and environmental conditions.

Role in Industrial Drive Systems

The BMD 118 drive unit provides controlled rotary drive power for compatible machinery. The model references indicate a specific mechanical and electrical configuration that must match the application. The user should confirm the supply requirements, mounting arrangement, and output characteristics before installation.

The unit should not be exposed to loads beyond its specified capacity. Shock loads, misalignment, and excessive overhung loads can affect bearings, gears, and seals. The machine design should provide adequate support for the drive unit and connected shafts.

Model Identification and Compatibility

The model BMD 118 14 3000 400 165 24 K 67 TC1 and the reference JB00004871 should be checked against the project documentation. The complete identification includes mechanical and electrical details that must match the application. Similar drive units can differ in mounting, ratio, brake arrangement, and supply data.

Compatibility includes the supply voltage, frequency, mounting flange, output shaft, and available space. The user should confirm that the drive unit connects correctly to the machine. If the unit is part of an existing system, the original mounting position and coupling arrangement should be reviewed.

Mechanical Installation

The drive unit should be mounted on a rigid structure that can support its weight and torque. The mounting surface should be clean and flat. Fasteners should be tightened to the specified values. The unit should not be distorted by uneven mounting surfaces or excessive bolt force.

Shaft alignment should be checked carefully. Couplings should be aligned within the limits allowed by the coupling and drive design. Belt, chain, or gear connections should follow the machine design and the product documentation. Guards should be fitted where rotating parts are accessible.

Electrical Connection

Electrical connection should be performed by qualified personnel following the site electrical code. Supply voltage, frequency, and winding connection must match the unit nameplate. Terminal connections should be correct and secure. Protective earth should be connected according to the installation requirements.

Cable sizes should be selected for current and voltage drop. Cable entries and glands should maintain the enclosure protection. The unit should be protected against short circuit and overload. Insulation should be checked where required before commissioning.


Commissioning

Commissioning should begin with a mechanical and electrical inspection. The drive unit should be uncoupled from the load where practical for a direction check. The user should observe current, speed, vibration, and noise. Any unusual behavior should be investigated before normal operation.

The direction of rotation should be confirmed. The driven machine should be checked for smooth operation. Commissioning records should include the model references, mounting position, electrical data, and test results.

Thermal and Environmental Considerations

The drive unit should be installed in an environment that matches its protection and cooling requirements. Ambient temperature, ventilation, and heat from nearby equipment affect operating temperature. The unit should not be covered by materials that prevent cooling.

If the application includes high duty cycles, the thermal margin should be reviewed. The unit should not be operated beyond its rated conditions without an engineering check. Good airflow supports stable operation.

Maintenance and Troubleshooting

Routine maintenance should include checking mounting bolts, couplings, cables, ventilation, and seals. The unit should be kept clean and free from contamination. Bearing noise and vibration should be monitored. Loose connections should be corrected.

If the unit overheats, the user should review load, duty cycle, ambient temperature, ventilation, and electrical data. If the unit runs noisily, alignment, bearings, and coupling should be checked. If the unit does not start, supply, control, and protection should be reviewed.

Maintenance Planning

Maintenance records should include the model reference, installation date, electrical data, and any replaced parts. These records help future service and replacement planning. Maintenance work should be performed with the machine isolated and secured.

If the drive unit must be replaced, the replacement should match the mechanical interface and electrical data. The coupling should be realigned after installation. The cause of the original failure should be investigated.

Application Value

The BMD 118 drive unit supports controlled motion in compatible machinery. It can be applied in industrial drive arrangements where the specified interface and electrical data fit the design. The actual performance depends on correct selection, mounting, electrical connection, and maintenance.

Summary

The Bonfiglioli BMD 118 14 3000 400 165 24 K 67 TC1 Drive Unit is intended for compatible industrial drive applications. Correct model verification, mounting, alignment, electrical connection, commissioning, and maintenance are essential.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection
  • BENDER RCMA475LY Residual Current Monitoring
  • BENDER IRDH575 Insulation Monitoring
  • BENDER IRDH265 Insulation Monitoring and Debugging
  • Bender RCMA475LY residual current monitor debugging
  • Beckwith Electric M-3425A Generator Protection Relay Debugging Guide
  • Automated MEX816U Expander Troubleshooting Guide
  • ASEM HT2150 Industrial Tablet Selection and Troubleshooting
  • Troubleshooting and practical application of Advantest U3771/3772 microwave spectrum analyzer
  • Advantest R6144 Programmable DC Voltage/Current Source (Calibration Source) Calibration and Maintenance
  • Aerotech UNIDEX 100/U100i single axis motion controller
  • Aerotech Ndrive MP Ultra Compact PWM Digital Servo Driver
  • Aerotech Ndrive HPe 10/20/30 High Performance PWM Digital Servo Drive
  • Aerotech Ndrive HLe maintenance replacement
  • Aerotech Ndrive CP maintenance replacement
  • Aerotech Ndrive Linear Drive Selection
  • Aerotech NDrive HL linear drive maintenance replacement
  • Aerotech NDrive HP 10/20/30 Maintenance and Replacement
  • Aerotech NDrive CP10 Servo Drive Guide
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting