Load inertia: 82000 kgm ² (converted to output shaft)
Environmental temperature: 30 ° C
Start frequency: 3 times per hour
Selection steps:
Based on P=55kW and n=1475 min ⁻¹, the preliminary selection chart shows that it is Size 15.
Considering the high inertia load, it is recommended to choose a dual delay chamber (CC) to limit the starting torque to below 150%.
Calculate the load inertia converted to the motor shaft
JLOAD=JRED+JLOAD_ref
And calculate the startup time based on this tacc
Calculate the startup temperature rise Δ Tacc and steady-state temperature rise Δ Tuts, and confirm that Tuts is less than the safety limit of 140 ° C.
Calculate Z-MAX and confirm that the actual startup frequency of 3 times per hour is within the allowable range.
If Z-MAX is insufficient, it needs to be increased to Size 17 or external cooling measures need to be added.
Final selection: KRG 15-CC-D_ (with disc brake), input shaft with guide hole (FP), output shaft with hole according to reducer shaft diameter, horizontal installation (OR), optional SP switching pin protection.