Basic Information and Core Positioning

Product positioning: 6 1/2 high-precision digital multimeter, specializing in laboratory precision measurement (such as reference voltage source calibration) and industrial production line testing (such as component parameter screening), balancing high resolution and wide measurement range.

Summary of Core Specifications

Measurement Function Range Accuracy (Typical Value) Resolution (Highest)

DC voltage (V DC) 10 μ V -1000V ± (0.0025% reading+0.0005% range) 1 μ V (2V range)

AC voltage (V AC) 100 μ V -1000V ± (0.02% reading+0.005% range) (50Hz/60Hz) 10 μ V (20V range)

DC current (I DC) 100nA-10A ± (0.01% reading+0.002% range) 10nA (200 μ A range)

AC current (I AC) 100nA-10A ± (0.05% reading+0.01% range) (50Hz/60Hz) 10nA (200 μ A range)

Resistance (Ω) 10m Ω -100M Ω± (0.005% reading+0.0005% range) 1m Ω (200 Ω range)

Capacitor (F) 100pF -100 μ F ± (0.5% reading+0.1% range) 1pF (2nF range)


Operation Guide: Panel Control and Basic Measurement

1. Key components of the front-end panel

Specific functional operation examples for component categories

Function selection area MEAS key: Switch measurement functions (V DC/V AC/I DC, etc.) Press MEAS → Rotate knob to select "V DC"

Range control area RANGE key: manually switch range; AUTO button: Press AUTO for automatic range, and the instrument will automatically match the 10V range (measure 5V signal)

HOLD in the data operation area: Freeze the current reading; STORE: Store data by pressing STORE → select "INT" (internal storage)

Menu control area CONFIG: Enter system configuration; MATH: For mathematical operations, press CONFIG → select "PLAY" to adjust the backlight

Display area 7-segment LCD: displays reading, unit, and status (such as "OVER" exceeding limit). When measuring 10V DC, it displays "10.00000 V DC"

2. Basic measurement process (taking DC voltage as an example)

Power on and self-test:

Press the POWER button, the instrument performs a 3-second self-test (ROM/RAM/ADC), displays "DMM4050", and then enters standby mode;

If the self-test fails (such as displaying "ERROR -121"), refer to the "Troubleshooting" section for repair.

Function and range settings:

Press MEAS → Rotate knob to select "V DC";

Press AUTO to enable automatic range (or press RANGE to manually select "10V" range).

Connection and measurement:

Connect the red probe to the "V Ω" terminal and the black probe to the "COM" terminal;

Connect the tested signal (such as a 5V reference source) and display the reading on the LCD (such as "5.00000 V DC").

Data processing:

Freeze the reading according to HOLD; Store internally according to STORE (up to 2000 sets);

Press VIEW to view stored data (knob to switch to previous/next).

image.png

Advanced features: Mathematical operations and limit testing

1. Mathematical operation function

Basic operations: Supports "+/-/×/÷" and "√", requires storing 2 data (STORE → 1/2) first, and then press MATH → select the operation type;

Example: Measure two resistors R1=100 Ω and R2=200 Ω, select the "+" operation, and the result shows "300000 Ω".

Special operations:

DB/dBm calculation: used for audio/RF signals, follow MATH → dB → select reference value (e.g. 0dBm=1mW);

Relative measurement (Δ): Press MATH → Δ → to store the reference value, and subsequent readings will display the difference from the reference (e.g. reference 5V, measuring 5.0001V will display "+0.0001V").

2. Extreme testing function

Function purpose: Set upper and lower limits, trigger alarms when exceeding limits (LED red light+beep), suitable for batch screening on production lines;

Operation steps:

Press Limit → select "HI/LO" (upper/lower limit);

Set the limit value for rotating knob (such as HI=110 Ω and LO=90 Ω when measuring resistance);

Press START to start the test, the reading will display "IN" (green light) within 90 Ω -110 Ω, and "OUT" (red light+beep) when exceeding the limit.

3. Remote control (GPIB/USB)

Interface specifications:

GPIB: Supports IEEE 488.2 protocol, Talker T6/Listener L4, Address 0-31 can be set;

USB: Compatible with USBTMC protocol, supports plug and play (no driver required).

SCPI command example:

Measure DC voltage (10V range, 0.001 resolution): MEASure: VOLTage: DC?  10,0.001;

Read stored data (Group 10):: DATA: READ?  10;

Set GPIB address: SYSTem: GPIB: DDRess 22.


Calibration and maintenance

1. Self calibration process

Trigger condition:

Regular triggering: recommended for 90 days (stable environment temperature ± 2 ℃) and 30 days (environment fluctuation>5 ℃);

Manual trigger: Press and hold the CAL key when turning on, or press CONFIG → CAL → START.

Calibration steps:

Disconnect all probes, the instrument displays "CALIBRATION...";

Internal calibration of ADC and reference source (approximately 2 minutes), displaying "CAL PASS" upon completion;

If 'CAL FAIL' is displayed, check the ambient temperature (+18 ℃ -+28 ℃) and recalibrate.

2. Error correction

External correction: When the measurement accuracy exceeds the limit, the correction value can be entered (CONFIG → CAL → CORECT);

Example: Measure a 10V reference source, read 10.0001V, enter the correction value "-0.0001V", and the subsequent readings will be automatically compensated.

Temperature compensation: The instrument has a built-in temperature sensor that automatically compensates for resistance/capacitance measurements (± 0.001%/℃).

3. Troubleshooting

Possible causes and solutions for the fault phenomenon

No display/power adapter failure, fuse blown, replace with 12V/3A adapter; Check the "FUSE" terminal (2A/250V fuse)

The reading drift is too large and self calibration is not performed due to environmental temperature fluctuations; Ensure stable ambient temperature (± 1 ℃/hour)

GPIB unresponsive address mismatch, cable loose confirmation GPIB address (: SYST: GPIB: ADRD?); Replace GPIB cable

Error Code -221 Parameter Out of Range Check Command Parameters (e.g. MEAS: VOLT: DC?)? 2000 over 1000V range)


Safety and Environmental Compliance

1. Safety level and operating standards

Overvoltage category: CAT III 1000V (distribution system), CAT IV 600V (low-voltage power grid);

Terminal rating:

V Ω terminal: maximum 1000V DC/AC;

Terminal A: Maximum 10A DC/AC (continuous), 20A (30 second pulse);

Safe operation: It is prohibited to plug or unplug probes with power on; Wear insulated gloves when measuring>600V; Stop using when the terminal is damaged.

2. Environmental parameters

Explanation of Environmental Category Specification Requirements

If the working temperature exceeds the range of+18 ℃ -+28 ℃, the self calibration cycle needs to be extended (e.g. once every 30 days for+10 ℃ -+18 ℃)

Storage temperature -40 ℃ -+70 ℃. Storage in humid/corrosive environments is prohibited

When the humidity is between 20% and 80% (without condensation), dehumidification is required before use when the humidity is above 80%

Altitude ≤ 2000m, high altitude (>2000m) requires derating for use (e.g. voltage range x 0.8)

image.png

  • GE Fanuc VMIVME-5588 High-speed Reflective Memory Board
  • VMIC VMIVME-5565 Reflective Memory Board
  • VMIC VMIVME-2127 Voltage Source Digital Output Board
  • VMIC VMIVME 4512 Analog VME Process PCB Assembly
  • GE Fanuc VMIVME-3122-022 Analog I/O Module
  • VMIC VMIVME 5576 High Speed Fiberoptic Network Board
  • FANUC VMIVME-7452 VMEbus Analog I/O Board
  • FANUC VMIVME-2210 VMEbus Digital Output Board
  • FANUC VMIVME-7750-734000 VMEbus Single Board Computer
  • VMIC VMIVME 2210 VMEbus DO 28V Digital Output Board
  • VMIC VMIVME DR11W VMEbus DMA Interface Module
  • VMIC VMIVME-2536-200 5V Optically Coupled Digital I/O Board
  • VMIC VME-7754 VMIVMF7754-259000 VMEbus Control Card
  • VMIC 2170A VME Interface Board
  • GE VMIC PMC-5565PIORC-210000 Reflective Memory PMC Node Card
  • VMIC VMIVME-7750-750000 VME Single Board Computer
  • VMIC VMIVME-7751 VME Single Board Computer
  • VMIC 332-004512 Analog VME Process Board
  • VMIC VMIVME2528 VME Interface Board
  • FANUC VMIVME-2120 VME Bus Interface Board
  • FANUC VMIVME-2540 VME Bus Interface Board
  • FANUC VMIVME-3230 VME Bus Interface Board
  • FANUC VMIVME-4514 VME Bus Interface Board
  • ETEL DSB2S154-211E-000H Servo Amplifier
  • ETEL DSCQT112-111-000 Motion Control Module
  • ETEL LMG20-050-3QB-211A Servo Motor – High Torque Linear
  • ETEL EU-LCP-0-0-1000-01 Communication Card
  • ETEL DSA2P174ZA-033A Servo Amplifier Driver
  • ETEL EA-P2M-400-15/40A-0100-00 Servo Driver
  • ETEL DSC2P152-111-000 Servo Drive Amplifier
  • ETEL LMS15-050-3UA-209A Linear Motor
  • ETEL DSC2P152-111D-000A Controller
  • ETEL DSB2P131-111E-000B Digital Servo Amplifier Position Controller
  • ETEL DSO-PWR111C-000B Power Supply Module
  • ETEL DSCDP324-321F-000C Servo Driver
  • ETEL DSC2P152-111B-000D Controller
  • ETEL DSB2P142-111E-000H Circuit Board
  • ETEL LMG05-030-3QA-H01 Linear Motor
  • ETEL DSC2P152-111F-000A Controller
  • ETEL DSA2S211ZA Servo Drive
  • ETEL DSCDM332-112-000 Drive Module
  • ETEL DSCDP334-421-000 Digital Position Controller Servo Drive
  • ETEL EA-P2M-400-15/40A-0100-00 AccurET Servo Drive
  • ETEL TMA0140-050-3UB-202B Torque Motor
  • ETEL DSA1DL1D.PCB Servo Drive Board
  • ETEL DSA2DL 1A Servo Drive
  • ETEL DSMAX111B-000B Servo Drive
  • ETEL DSO-PWS111C-000B Power Supply Module
  • ETEL DSC2P142-111B-000D Servo Drive Amplifier
  • ETEL DSC2P132-111D-000A Servo Drive Amplifier
  • ETEL DSC2P152-111B-000D Servo Drive Amplifier
  • ETEL DSB2P131-121E-000H Servo Drive Amplifier
  • ETEL DSB2P142-111E-000H Servo Drive Amplifier
  • ETEL DSO-PWR112C-000A Power Supply Module – High Power
  • ETEL DSO-PWR111C-000A Power Supply Module
  • ETEL DSB2P121-121E-000H Servo Drive Amplifier
  • ETEL DSB2S134-111E-000H Digital Servo Amplifier
  • ETEL RTMA0140-070-AQN-21E Motor
  • ETEL DSCDP132-111-000 Dual Controller Circuit Board – Motion Control
  • ETEL LMS15-050-3UA-209Aft Linear Motor
  • ETEL DSCDP324-322G-000A Position Controller
  • ETEL DSA2P174ZA-033A Servo Amplifier Driver
  • ETEL DSA2P174ZA-017A Servo Amplifier Driver
  • ETEL LMD10-050-3QA-223A Linear Motor
  • ETEL EU-LGP-0-0-1000-00 PCI Network Card
  • ETEL DSO-PWS111C-000B Power Supply Module
  • ETEL DSC2V174-111C-001A Servo Controller
  • ETEL EA-P2M-600-15/40A-0000-01 AccurET Modular Position Controller
  • ETEL RTMA0140-070-AQN-21B DD Motor
  • ETEL DSC2P144-421-000 Servo Driver
  • ETEL EA-P2M-400-15-40A-0100-00 Servo Drive
  • ETEL DSCDM341-111C-000B Board
  • ETEL LMD10-050-3QA-223A Motor
  • ETEL RTMA0140-070-AQN-21E DD Motor
  • ETEL DSCDM342-111-000 Servo Variator
  • ETEL DSC2P152-111E-000A Servo Amplifier
  • ETEL LMS15-050-3UA-209A Motor
  • ETEL RTMA0140-070-AQN-21C DD Motor – High Torque Direct Drive
  • ETEL DSCDP334-421G-000A Servo Drive
  • Etel DSB2S154-211E-000H Digital Servo Amplifier
  • ETEL EA-P2M-400-15/40A-0100-00 AccurET Servo Drive
  • ETEL DSA2P-174ZA-017A Digital Servo Amplifier
  • ETEL EA-P2M-400-15/40A-0100-00 Servo Drive
  • ETEL LMP07-100-3TAS-229 Linear Motor Primary Part
  • ETEL LMA11-120-3ZA-359A Linear Motor
  • ETEL EA-S0M-400-40/80A-0000-00 Drive Power Supply
  • Etel DSCDP334-421-000 Driver
  • ETEL DSCDM341-111C-000B DSCDM Drive Board
  • Etel DSA1 Digital Servo Amplifier
  • ETEL DSA2P174ZA-033A Servo Amplifier
  • ETEL DSCDM342-111-000 Servo Verifier
  • ETEL LMS15-050-3UA-209A Linear Motor
  • ETEL P2M-048-2.5/5A AccurET Position Controller – Modular
  • ETEL LMD10-050-3QA-223A Linear Motor – Compact Precision
  • ETEL EA-P2M-400-05/10A-0000-01 Drive – Precision Motion
  • ETEL LMP07-100-3TAS-229 Linear Motor Primary Part
  • ETEL EU-LGP-0-0-0000-00 Motion Control Card – Precision Control
  • ETEL DSC2P152-111E-000A Servo Amplifier
  • ETEL EA-P2M-400-15/40A-0100-01 Servo Drive
  • ETEL EA-SOM-300-40/80A-0000-00 AccurET Power Supply Module
  • ETEL LMG10-1050-3QA-H01 Linear Motor
  • ETEL EA-SOM-300-40/80A-0000-00 AccurET Modular Power Supply
  • ETEL EA-P2M-400-15/40A-0100-00 AccurET Servo Drive
  • ETEL EA-P2M-400-15/40A-0100-01 Servo Driver
  • Etel RTMA0140-070-AQN-21B High Speed Motor
  • ETEL DSC2P141-111-000 Linear Servo Amplifier
  • ETEL DSB2S134-211E-000H Digital Servo Amplifier
  • ETEL 3LM-23C Motion Controller
  • Etel DSO-SER211-000 Power Add-On Board
  • ETEL DSCDP334-421-000 Servo Drive
  • CTI-Cryogenics 8116071G001 Enhanced On-Board 8F Cryopump
  • ETEL LMD10-050-3QA-223A Linear Motor
  • Etel DSO-SER211-000 Servo Card Power Add-On
  • ETEL LMG05-050-3QA-213A Linear Motor
  • Etel DSO-SER211-000 Power Add-On Board
  • ETEL EU-LGP-0-0-0000-00 Motion Control Card
  • ETEL EA-P2M-400-15/40A-0100-00 AccurET Servo Drive
  • ETEL DSA2P1540A Digital Servo Amplifier
  • ETEL DSC2P131-111-000 Drive Board
  • ETEL DSC2P131-111D-000A Servo Drive
  • Etel SA-IL 03-208 Linear Motor Section 208mm
  • ETEL EA-P2M-300-4/7.5A-0000-01 AccurET Position Controller
  • ETEL DSO-SER211-000 Power Board
  • ETEL DSC2P131-111F-000A Servo Amplifier
  • ETEL DSA1P6242B Digital Servo Amplifier
  • ETEL DSC2P131-111B-000B Regulator
  • ETEL DSA2P1540A Digital Servo Amplifier
  • ETEL EA-P2M-048-2.5/5A-0100-01 Drive