HIMax X-FAN system fan

来源: | 作者:FAN | 发布时间 :2026-02-27 | 228 次浏览: | 🔊 Click to read aloud ❚❚ | Share:

HIMax X-FAN system fan

Overview of HIMax X-FAN System Fans

The HIMax X-FAN system fan is an essential component of the HIMax programmable electronic system and is crucial for the stable operation of the system. The fan must be installed directly above the base plate to ensure forced convection cooling for modules with ventilation openings at both the bottom and top. Hot air is discharged upwards through a fan, so sufficient space must be ensured during installation to achieve good heat dissipation.

The X-FAN series offers multiple models to accommodate HIMax baseboards of different sizes and diverse environmental requirements. All system fans have redundant power supply capability and real-time monitoring function, continuously reporting their operating status through the LED indicator lights and fault relays on the front panel. The reliability of the HIMax system is not only reflected in its core controller, but also in the excellent design of key auxiliary components such as the X-FAN system fan.


Product Model and Selection Guide

The X-FAN series has been subdivided based on the base plate, installation method, and performance indicators it is compatible with. The correct selection is the first step in ensuring the long-term stable operation of the HIMax system in the expected environment.

2.1 Model and Base Plate Matching

Different HIMax baseboards require specific models of system fans:

System fan model, installation method, fan quantity, applicable base plate

X-FAN 10 01/03 Backboard Installation 2 X-BASE PLATE 10 01

X-FAN 15 01/03 Backboard Installation 3 X-BASE PLAY 15 01

X-FAN 15 02/04 19 inch rack 3 X-BASE PLAY 15 02

X-FAN 18 01/03 Backboard Installation 4 X-BASE PLATE 18 01

2.2 Selection of Air Volume and Noise Level

Fans of the same size are available in two performance versions, and users can weigh their requirements for noise and heat dissipation based on the site:

High volume models (01/02 series): such as X-FAN 10 01, 15 01, 15 02, 18 01. These fans have higher sound pressure levels (e.g. X-FAN 18 01 is approximately 67 dB (A)) and higher air flow rates (e.g. X-FAN 18 01 is 480-880 m ³/h). HIMA recommends using high air volume models in the following situations:

When the expected ambient temperature is high.

When maintenance cannot be carried out immediately in an unmanned environment.

Low noise models (03/04 series): such as X-FAN 10 03, 15 03, 15 04, 18 03. The sound pressure level of these fans is significantly reduced (for example, X-FAN 18 03 is about 49 dB (A)), and the air flow is moderate. HIMA recommends using low-noise models in the following situations:

When the ambient temperature is below 40 ° C.

In noise sensitive environments, such as manned switch rooms.


Design and functional characteristics

3.1 Mechanical Structure

The X-FAN system fan features a sturdy aluminum casing. The front panel design is simple, including LEDs for indicating operating status and a flip cover for easy operation. This cover plate needs to be opened during installation to facilitate the insertion or removal of modules. The fan offers two installation methods:

Backboard installation: Use pear shaped holes and grooves on both sides of the fan to install the flange, and fix it on the backboard (such as the mounting plate) with M6 bolts.

19 inch rack installation: Suitable for X-FAN 15 02 and 15 04, fixed to the 19 inch rack using the fastener kit (M 2212) provided by HIMA through the four long holes on the mounting flanges on both sides.

3.2 Redundant power supply design

X-FAN fans support redundant power inputs (L1+/L1- and L2+/L2-), which is a key design to improve overall system availability. Even if one power supply fails, the other power supply can immediately take over to ensure the continuous operation of the fan and maintain the normal heat dissipation of the HIMax system.

Key points for power connection:

A 24 VDC power supply that meets SELV or PELV requirements must be used.

When connecting, it is necessary to ensure the correct polarity. The reverse polarity protection diode inside the fan can prevent damage caused by reverse connection.

Single power supply operation: If only one power supply (such as L1+) is used, it needs to be connected to terminals 1 and 2, and a jumper should be connected between terminals 5 and 3 at the same time. This can prevent the fan monitoring system from falsely reporting L2 power loss.

3.3 Comprehensive Fan Monitoring

The X-FAN system fan has built-in intelligent monitoring function to continuously verify its own operating status. Once a fault is detected, the fault relay will immediately activate and the red Error LED on the front panel will light up.

The monitoring system can detect the following faults:

One of the two input voltages has failed.

One or more fans are blocked.

The fan speed is too low.

The input voltage is too low.

The circuit connecting to one or more fans is interrupted.

Fault relay:

Relay contacts (normally closed NC, common C, normally open NO) can be used to connect external sound and light alarms, with a maximum switch current of up to 4 A. In normal operation, the relay coil is energized, the normally open contacts close, and the normally closed contacts open. Once a fault occurs, the relay loses power, the contact state reverses, and a clear fault signal is emitted.

Installation and Startup

4.1 Installation location and environment

The system fan must be installed directly above the HIMax base plate.

To ensure good airflow circulation, sufficient space should be reserved above and below the fan. For high air volume models with backplate installation, 1U space needs to be reserved above and below; For low-noise models, 2U of space needs to be reserved.

The installation location must meet environmental requirements: temperature from 0 to 60 ° C, humidity ≤ 95% (no condensation), altitude<2000 m.

4.2 Power Connection

Peel off the insulation layer at the end of the connecting cable, with a length of 6mm.

According to the terminal definition table, insert the cable into terminals 1 to 4 of the connector plug.

Use a 0.4 x 2.5 mm slot screwdriver to tighten the terminals with a torque of 0.2-0.25 Nm.

If using a single power supply, be sure to install a jumper between terminals 5 and 3.


Diagnosis and maintenance

5.1 LED Diagnosis

Green Run LED: It lights up when there is sufficient power supply.

Red Error LED: It lights up when faults such as low voltage, blocked fan, or low speed are detected.

5.2 Fault Relay

By monitoring the contact status of the relay, the control system can remotely determine the health status of the fan.

5.3 Maintenance and Replacement

The X-FAN system fan contains moving parts and is a consumable with a lifespan. HIMA recommends regularly replacing fans and sending them back to HIMA for maintenance based on the operating environment temperature

Under normal operating temperature (<40 ° C): Replace every 6 years.

At higher operating temperatures (>40 ° C): replace every 3 years.

When replacing, the same model or a replacement model approved by HIMA must be used. Operators need to have knowledge of ESD protection.


Technical Data Summary

Parameter specifications

Working voltage 24 VDC, -15%/+20%

Input current (maximum) X-FAN 18 01: 4 A;  X-FAN 18 03: 0.8 A

Fault relay switch current 30 VDC/4 A

Working temperature: 0 ° C to+60 ° C

Storage temperature -40 ° C to+85 ° C

Protection level IP20

Dimensions (height x width x depth) 88.1 mm x (depending on model) x 259.5 mm

Weight X-FAN 10 series: approximately 2.7 kg; X-FAN 18 series: approximately 4.5 kg

  • MTL 2213 Isolated Intrinsic Safety Barrier
  • MTS TBF120/12TS Servo Amplifier
  • MTS TBF120/7R Resolver Servo Amplifier
  • MULLER COAX MK32NC Coaxial Connector Module
  • MURATA DCC2223A 3EST125-977 Power Filter Module
  • MURR 857781 Industrial Interface Module
  • MYKROLIS FC-280SAV Gas Flow Control Module
  • Nabtesco BTC-304 Brake Controller
  • NACHI UM356B Industrial Module Analysis
  • NACHI MFMA452D5V3 Servo Motor Specification
  • NACHI BUY222 Robotic Control Component
  • NAI 64SD1-08KRF1-13 Synchro-to-Digital Data
  • NAICH AUX111 Auxiliary Contact Specification
  • NAIS ANR5131 Micro Laser Sensor Controller
  • NATIONALA MM-4M-R Industrial Control Module
  • NEC FC-9821X MODEL2 Factory Computer
  • NEC FC-9801F Legacy Industrial Computer
  • NEC FC-9821X MODEL1 Industrial Computer
  • NEC FC-9821KE Industrial Panel PC
  • NEC RSA-983/D Embedded Industrial Computer
  • NEC G8NXAA5G Industrial Controller
  • NEC 136-551735-D-04 Genius Bus Interface
  • NEC SC-UPCIN-3 Industrial Control Module
  • NEC PC-9821XB10 Industrial Control Computer System
  • NEC 136-553623-A-01 Industrial Network Communication Module
  • NEC 136-551973-A-01 Control Processing Board
  • NEC 136-551733-B-02 Industrial Control Interface Module
  • NEUGART PLE120/115 Gearbox
  • NEUGART PLE120 Planetary Gearbox
  • NEXUS CONTROLS 369B1843G5009 Technical Data
  • NI NI-9694 Digital I/O Breakout
  • NI SBRIO-9627 Embedded Single-Board
  • NI SCXI-1102C Amplifier Module
  • NI sbRIO-9627 783817-01 Embedded Controller
  • NI GPIB-140A 186135G-01 GPIB Controller
  • NI GPIB-140A 186135F-31 GPIB Interface Card
  • NI GPIB-140A 186135H-01L Fiber Optic Extender
  • NI 192061B-02 Shielded DAQ Cable
  • NI SCXI-1346 Multi-Chassis Cable Adapter
  • NI SCXI-1600 USB Data Acquisition Module
  • NIBCO WD2000 Ductile Iron Butterfly Valve
  • NIKUNI 25KLD07Z-M Magnetic Drive Pump
  • NMB MAT 2410ML 05W B50 Industrial Cooling Fan High Reliability
  • NMS CG6565 64 2L 8TE Communication Gateway High Capacity Network Module
  • NMS CG6060 32 4TE1 Communication Gateway for Network Systems
  • NOVELLUS 02-113640-00 Industrial Control Module System Component
  • NOVOTRON ND32-5610VS-001-000-00 Drive
  • NYQUIST IOB-80 I/O Interface Board
  • OBERG INDUSTRIES F-DMDM-PM-110E Specifications
  • OCM 44A737830-001R04 Module
  • OEMAX NX-BASE08 8-Slot Base Plate Manual
  • OEMAX NX-BASE05 5-Slot Base Plate
  • OEMAX NX-CPU750B Basic PLC CPU
  • OEMAX NX-CPU750C High-Performance PLC CPU
  • OEMAX NX-Y16R 16-Point Relay Output Module
  • OEMAX NX-RTD8 8-Channel RTD Input Module
  • OEMAX NX-SLAVE Remote I/O Slave Module
  • OEMAX NX-SCU Serial Communication Unit
  • OEMAX NX-POSI2 2-Axis Positioning Module
  • OEMAX NX-DUMMY Dummy I/O Module
  • OEMAX NX-CPU700P PLC Controller
  • OEMAX NX-BASE10 PLC Backplane
  • OEMAX NX-AO4C 4-Channel Analog Output Module
  • OEMAX NX-AI8C 8-Channel Analog Input Module
  • OMACO GF0-57CQD-002 Industrial Control Module Precision Automation
  • OPTIMATE OP-620 Industrial Automation Control Module
  • OPTIMATE OM1510 Industrial Control Module Performance Solution
  • OPTO 22 SNAP-IDC5D Digital Input Module for Automation
  • OPTO 22 SNAP-AITM-2 Thermocouple Module
  • ORIENTAL A4722-9215KM Cooling Fan
  • ORIENTAL MOTOR 2GK180K Gearhead Specifications
  • OSRAM DULUX L 36W 840 865 Lamp Specification
  • OTHER FLASH SERIES 2 Memory Module Data
  • OVATION 1X00458H01 Control Module Specification
  • Emerson Ovation 1C31157G02 Event Sequence Module
  • Emerson Ovation 5X00070G04 Analog Input Module
  • OXIDE 0020-31655 Industrial Controller
  • ABB FAU810 C87-11006 / C10-12010 Flame Analyzer
  • Pilz PSSu E F 4DI Safety Input Module
  • Pepperl+Fuchs KFD2-UFC-1.D Frequency Converter
  • Pacific Scientific VDE0530-S1 Stepper Motor
  • Pacific Scientific 6410-001-N-N-N Stepper Drive
  • PACIFIC LA23GCKC-1Y Servo Motor Reliable Automation Motion Solution
  • PACIFIC LA23GCKX-P500A Servo Motor Advanced Industrial Motion Control
  • PACIFIC LA23GCKC-P500A High Precision Servo Motor for Industrial Automation
  • Pacific Scientific E32NCHA-LNN-NS-00 Hybrid Stepper Motor
  • Pacific Scientific SCE903A3-002-01 Servo Drive
  • Pacific Scientific 6410-024-N-N-N Stepper Motor Drive
  • PALCLEAN JD-BXG Industrial Control Module
  • Panametrics 704-673-20 Ultrasonic Flow Meter
  • Panasonic MSD043A1XX AC Servo Driver
  • Panasonic KX-FT936CN Plain Paper Fax Machine
  • Panasonic DL-1109CWS Electric Bidet Toilet Seat
  • PACIFIC SCIENTIFIC 33VM52-000-29 LDA-196-1000CE Servo Motor Controller
  • PACIFIC LA23GCKC-1G Linear Actuator Specifications
  • PACIFIC PC3406AI-001-E Stepper Controller Manual
  • PACIFIC SCE904AN-002-01 Servo Drive Analysis
  • PACIFIC 6445-001-K-N Digital Servo Drive Details
  • PACIFIC SCIENTIFIC R43HCNA-R2-NS-VS-00 Motor Data
  • Pacific Scientific H32NCHA-LNN-NS-00 Hybrid Motor Performance
  • ABB DSAI130DK01 3BSE020828R1 Analog Input Module
  • Parker 466966-0001-3820 Industrial Component Data
  • PARKER ZETA6104 Microstepping System
  • PARKER COMPAX 2500S/F3 Servo Drive Manual Details
  • PARKER CX-DH Indexer Drive Technical Specifications
  • PARKER 6K8 Motion Controller Features and Specifications
  • PARKER EVM32-BASE I/O Module Base Technical Specification
  • ABB Pb PN-112718 Digital Input Module
  • Pb PN-45734 PN-73899 Industrial Automation Module
  • Control Techniques Pb PN-40856 Industrial Control Module
  • Pb PN-104412 4002910956 Industrial Control Module
  • Siemens Pb PN-41513 Industrial Ethernet Module
  • Pelco PA30-0065-00-A1 PTZ Decoder Module
  • Pentek FILTER 3F11 800000919 Pleated Filter Cartridge
  • Pepperl+Fuchs RSD-TI-EX8 Temperature Input Module
  • PERITEK AC7-00712-1113 Industrial Interface Module
  • PFEIFFER EVR116 Vacuum Control Module
  • Pepperl+Fuchs RSD-CI-EX8 Hazardous Area Interface Module
  • PEPPERL+FUCHS 2108HAT Intrinsic Safety Barrier Module
  • Philips 958481320201 PROC+ Processing Unit
  • Philips 958481321300 PSB Power Supply Board
  • Philips 958481321220 PD208 Power Module
  • PHILIPS 958481321200 PD216 Control Module
  • PHILIPS 958481320201 PROC PLUS Control Module
  • Philips 958481320400 PIF Interface Module
  • Philips 958481320100 LCB Control Board
  • PHILIPS 958481223220 Industrial Control Module
  • PHILIPS 958481223223 Industrial Control Module