Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Trasmital Bonfiglioli 301 L2 Gear Reducer
    ❤ Add to collection
  • Trasmital Bonfiglioli 301 L2 Gear Reducer

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥23155.00
      ¥24178.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:1.778KG
    • Quantity:
    • (Inventory: 52)
Description
<span style="font-family: arial; font-size: 18px;">Trasmital Bonfiglioli 301 L2 Gear Reducer</span>

TRASMITAL BONFIGLIOLI 301 L2 18.2MZE1AEAU2S0 2T301L2018A10 Gear Reducer Ratio 18.2

The TRASMITAL BONFIGLIOLI 301 L2 gear reducer, identified by the codes 18.2MZE1AEAU2S0 and 2T301L2018A10, is an industrial reduction unit configured with an 18.2 to 1 ratio. Trasmital is a brand within the Bonfiglioli group, and the 301 series is used in demanding drive systems that require robust construction and reliable torque transmission. The L2 designation defines the gear stage and shaft arrangement of the specific build. This reducer is suitable for conveyors, mixers, and heavy industrial machinery.

Product Overview

The 301 series is designed for industrial duty with a rigid housing and precise gear manufacturing. The 18.2 to 1 ratio provides a moderate to high reduction, making the unit suitable for driven equipment that requires lower output speed and increased torque. The codes 18.2MZE1AEAU2S0 and 2T301L2018A10 define the shaft, flange, mounting, and option details of the specific build. The nameplate and dimensional drawing should be consulted for exact installation data.

The reducer housing supports the input and output shafts and is designed for rigidity so that the gear mesh remains stable under load. Bearings are selected for the expected radial and axial forces. Lubrication is contained within the housing and distributed to the gears and bearings during operation. Seals protect the internal components from dust and moisture in normal industrial environments.

Construction and Design

The gear stages are manufactured to precise tolerances to provide smooth rotation and efficient torque transfer. The housing supports the shafts and bearings with high stiffness. The input interface is machined for precise mounting of the motor or drive component. The output shaft is machined to accept couplings, pulleys, sprockets, or other driven components. The housing may include mounting feet, flanges, or other interfaces depending on the build.

Correct alignment between the motor, reducer, and driven equipment is important for efficient power transmission and long bearing life. The housing design supports heat dissipation and structural strength. Lubrication and sealing protect the internal components during operation. The unit should be selected with an appropriate service factor for the application.

Performance Characteristics

The 18.2 to 1 ratio determines the output speed by dividing the motor speed by 18.2. The output torque depends on the motor power, reducer efficiency, and service factor. The gearbox provides smooth torque transfer and reliable operation when matched to the load. The L2 configuration supports a balance between ratio and efficiency for the specific application.

The reducer should be selected with an appropriate service factor for the duty cycle. Starting loads, shock loads, and continuous operation affect the mechanical and thermal capacity of the unit. Lubrication condition and operating temperature should be monitored. Correct installation and maintenance help maintain stable performance and long service life.


Applications

The Trasmital Bonfiglioli 301 L2 reducer is suitable for belt conveyors, screw conveyors, mixers, agitators, packaging machines, and general industrial drives. The robust construction is useful in applications that require high torque capacity and reliable operation. The reducer can be paired with standard three phase motors or other drive components that match the input interface.

When variable speed operation is required, the motor and reducer should be evaluated together. The reducer should be mounted on a rigid base that can withstand the torque reaction. Correct selection helps ensure reliable operation and long service life in demanding industrial environments.

Installation Guidelines

Installation should begin with a check of the nameplate data and a visual inspection of the reducer. The unit should be mounted on a rigid base that can withstand the torque reaction. Mounting bolts should be tightened to the recommended torque. The motor or drive component should be aligned with the reducer input so that the shaft connection engages correctly. The output shaft should be aligned with the driven equipment to avoid excessive loads on bearings and seals.

After installation, the reducer should be checked for smooth rotation and correct oil level. A short run without load helps confirm that the assembly operates correctly. Any unusual noise, vibration, or temperature rise should be investigated before full service. Electrical connections should be made by qualified personnel following local regulations.

Maintenance Recommendations

Regular maintenance supports reliable performance and long service life. Oil level and oil condition should be checked at recommended intervals. The first oil change should be performed after the initial running in period, and later changes should follow the schedule for the operating conditions. Seals and bearings should be inspected periodically. Leakage, abnormal noise, or vibration should be addressed promptly.

The exterior of the reducer should be kept clean to support heat dissipation. Adequate airflow around the housing helps maintain stable temperatures. In dusty or humid environments, additional protection may be needed. Maintenance records help identify trends and support planned servicing. Following a consistent maintenance schedule reduces the risk of unexpected downtime.

Selection Considerations

When selecting the 301 L2 18.2 reducer, engineers should confirm the required output torque, output speed, duty cycle, and environmental conditions. The 18.2 to 1 ratio and motor speed determine the output speed. The available torque depends on motor power and reducer efficiency. A service factor should be applied for starting loads, shock loads, and continuous operation. The input and output interfaces must match the motor and driven equipment.

The mounting position should provide adequate support and allow correct lubrication. The shaft dimensions and flange details should be checked against the machine design. For applications with high radial loads, additional bearing support may be required. Correct selection helps ensure smooth operation, stable thermal behavior, and long service life.

Conclusion

The TRASMITAL BONFIGLIOLI 301 L2 gear reducer with an 18.2 to 1 ratio offers a robust reduction solution for demanding drive systems. Its construction supports high torque capacity, stable gear mesh, and reliable performance in conveyors, mixers, and heavy industrial machinery. With correct installation and maintenance, the reducer provides dependable operation and long service life.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection
  • BENDER RCMA475LY Residual Current Monitoring
  • BENDER IRDH575 Insulation Monitoring
  • BENDER IRDH265 Insulation Monitoring and Debugging
  • Bender RCMA475LY residual current monitor debugging
  • Beckwith Electric M-3425A Generator Protection Relay Debugging Guide
  • Automated MEX816U Expander Troubleshooting Guide
  • ASEM HT2150 Industrial Tablet Selection and Troubleshooting
  • Troubleshooting and practical application of Advantest U3771/3772 microwave spectrum analyzer
  • Advantest R6144 Programmable DC Voltage/Current Source (Calibration Source) Calibration and Maintenance
  • Aerotech UNIDEX 100/U100i single axis motion controller
  • Aerotech Ndrive MP Ultra Compact PWM Digital Servo Driver
  • Aerotech Ndrive HPe 10/20/30 High Performance PWM Digital Servo Drive
  • Aerotech Ndrive HLe maintenance replacement
  • Aerotech Ndrive CP maintenance replacement
  • Aerotech Ndrive Linear Drive Selection
  • Aerotech NDrive HL linear drive maintenance replacement
  • Aerotech NDrive HP 10/20/30 Maintenance and Replacement
  • Aerotech NDrive CP10 Servo Drive Guide
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC