Mitsubishi Electric GT23 Series HMI Maintenance Guide

F: | Au:FANS | DA:2026-06-01 | 48 Br: | 🔊 点击朗读正文 ❚❚ | Share:

Turn off the power supply and check the power wiring and fuses

7.2 Backlight fault handling

When the POWER LED flashes orange blue and the screen darkens, touch input may be disabled (the manual clearly states that touch switch input is not available at this time). The backlight component or the entire machine should be replaced as soon as possible. Temporary measure: External lighting, using external switches instead of touch operation.

7.3 Communication Failure

If the communication cable is disconnected or the controller is not powered on, GOT will not be able to operate. In system design, it must be assumed that GOT communication failures will occur, and important operations should be performed through switches other than GOT. For example, the emergency stop button must be directly connected to the safety relay, rather than just through a GOT touch switch.

7.4 Battery Alarm

When the battery level is low, the practical menu will display an alarm. The battery model is GT11-50BAT (lithium battery). Replacement steps:

Power off (all phases).

Open the battery cover and remove the old battery.

Install a new battery and ensure correct polarity.

Reset the clock after powering on.

Attention: The battery is not rechargeable, disassembled, heated, short circuited, welded, or put into fire. Transportation of lithium batteries must comply with transportation regulations.


EMC and low voltage command compliance

The GT23 series complies with the EU EMC Directive (2014/30/EU) and the Low Voltage Directive (2014/35/EU). To ensure compliance, attention should be paid to the following during installation:

Control and communication cables must be routed separately from the main circuit and power lines, with a minimum spacing of 100mm.

Signal cables should use shielded wires and the shielding layer should be reliably grounded.

The power terminal and ground terminal must be connected correctly.

The installation environment should meet pollution level 2 and overvoltage category II.

For equipment used in EU countries, manufacturers are required to declare compliance.


Safety precautions (key)

The manual repeatedly emphasizes the following safety points, which engineers must strictly follow:

9.1 Design Phase

GOT malfunction may cause the output to remain ON or OFF, therefore important safety signals must be monitored externally (such as hardware interlock).

Do not use GOT as the sole warning device (such as emergency stop). Independent redundant hardware should be used.

When modifying PLC programs or parameters through GOT, it is necessary to reset GOT or power on again as soon as possible, otherwise it may cause unexpected actions.

9.2 Wiring and Installation

The installation or removal of GOT can only be done after power failure (all phases).

Tighten the terminal screws with the specified torque.

Avoid foreign objects such as metal shavings and wire ends from entering the interior of GOT.

In oil mist or chemical environments, an oil proof protective cover must be installed, otherwise liquid infiltration may cause malfunctions.

9.3 Operation and Maintenance

Do not touch the terminals when powered on.

Before cleaning or re tightening the terminals, the power must be turned off.

Do not disassemble or modify the unit.

Before contacting the unit, touch the grounded metal to release static electricity.

Avoid dropping or strong impact when handling GOTs.

9.4 Network Security

For GOTs connected through the network, firewall measures should be taken VPN、 Anti virus and other measures are taken to prevent illegal access and DoS attacks. Mitsubishi is not responsible for any issues caused by cyber attacks.


Precautions for Testing Operations

Before conducting trial runs (such as forcibly setting/resetting components, modifying the current value of word components, changing timer/counter settings, etc.), be sure to carefully read the manual and familiarize yourself with the operating methods. Do not modify device data used for critical system operations, as this may result in erroneous outputs and accidents.


Maintenance and spare parts management

Given the lifecycle of electronic products, the following recommendations are suggested:

Regularly backup GOT project files to PC or SD card.

Check the battery level and replace it every 3-5 years.

Clean the screen with a soft cloth dipped in neutral detergent and avoid using organic solvents.

Spare parts reserve: at least one GOT of the same model, as well as batteries, SD cards, USB cables, etc.

When backlight failure or touch deviation cannot be calibrated, contact Mitsubishi authorized service center for repair or replacement.

  • B&R X20CP1486 Controller Manual
  • Siemens 6ES7134-4GB51-0AB0 Module Manual
  • Schneider LMC201CAA10000 Controller Manual
  • Fuji Electric NP1L-RS4 Module Guide
  • Mitsubishi FX2N-16LNK-M Master Guide
  • Yaskawa SGDM-08ADA SGMAH-08AAA41 Manual
  • Fanuc A20B-0008-0470 Board Manual
  • Calpeda T 70/B Module Specifications
  • Eurotherm TC3000 Power Drive Specifications
  • Mitsubishi QJ71GP21S-SX Module Manual
  • B&R X20AI4622 Analog Input Module 4 Channels
  • Siemens Simatic S5 PLC I/O and CPU Modules
  • Tel 38950 PCB Board 5044-000171-11 AP9Z-2033A
  • Sanyo PLC-XTC50L Multimedia Projector
  • Siemens 6GK7243-5DX30-0XE0 CP 243-5 AS-Interface
  • Omron V680-CA5D02-V2 RFID Controller
  • Pilz 570640 PSEN SL-1.0P Safety Switch
  • Schneider LXM62DD27D21000 Servo Drive
  • Pilz 401112 PITswitch en1.1a-5m-s Emergency Stop Switch
  • Pilz 774350 P2HZ X3 Safety Relay
  • Siemens S30810-Q1113-X4-6/02 EWSD Module Board
  • Honeywell 30751044-008 ROM PLC Control Board
  • Allen-Bradley 440R-W23219 MSR310P Safety Relay
  • Siemens 6GK5204-2BB10-2AA3 Industrial Ethernet Switch
  • Siemens YSU C32353ADDAGS C98043 PC Board
  • Schneider TM241CEC24T PLC Controller Modicon M241
  • VARIAN E15000591 PLC PCB Assembly 132102
  • Schneider Electric HMIG3U PLC Controller Module
  • Siemens 6ES7148-4FC00-0AB0 ET200 IO Module
  • Siemens A5E30484420 Simatic IPC Redundant PSU
  • Allen Bradley 1771-A3B Chassis Manual
  • Schneider BMEH586040 Processor Manual
  • Mitsubishi GT2508 Graphic Panel Manual
  • Mitsubishi FX2N-16LNK-M Link Module Manual
  • Beckhoff EL3011 Analog Terminal Manual
  • Siemens 6SN1145-1AA01-0AA1 Infeed Manual
  • Proface SP5000 Series Display Specifications
  • NUM 0204203001 Axes Board Manual
  • Square D LV434001 Ethernet Interface Manual
  • Omron NA5 Series HMI Module Specifications
  • ABB 57619104E Inverter PCB Control Board
  • Allen-Bradley 100-E205ED11 MCS-E Contactor 205A
  • Omron NS12-TS01-ECV2 Series Operation Panel
  • Allen-Bradley 440R-EM4R2 Guardmaster Safety Relay
  • Omron CS1D-DPL01 Duplex System PLC Module
  • Beckhoff CX2030-0115 Embedded PC Controller
  • ABB Pluto S20 v2 Cfs Safety PLC 2TLA020070R4700
  • B&R X20AT4222 Analog Input Module RTD
  • Inovance H3U-3624MT PLC Controller
  • GE Fanuc IC698CPE010 PLC CPU Module
  • Texas Instruments Siemens 505-6208-A Analog Input Module
  • VDISP 0035416 Card Module Industrial Display Controller
  • HITACHI TX09D80VM3CCA 3.5 Inch LCD Screen 240x320
  • Siemens 545 555 1105 1106 PLC Controller
  • H2-ECOM100 PLC Communication Module Ethernet
  • B&R X20CS1012 PLC Module X20 CS 1012
  • Siemens 6ES7212-1HF40-0XB0 PLC Module 24VDC
  • Omron C120-0C222 IO Module 3G2A6-0C222
  • Electromatic Denmark PLC TYPE 200816 Industrial Controller
  • SANYO PLC-XTC50L Projector 50-60Hz LCD Installation
  • LTi SO84.450 Servo Drive Controller - 450A Three-Phase BG7
  • LTi SO84.375 Servo Drive Controller - 375A Three-Phase BG7
  • LTi SO84.325 Servo Drive Controller - 325A Three-Phase BG7
  • LTi SO84.250 Servo Drive Controller - 250A Three-Phase BG7
  • LTi SO84.170 Servo Drive Controller - 170A Three-Phase BG6a
  • LTi SO84.143 Servo Drive Controller - 143A Three-Phase BG6a
  • LTi SO84.110 Servo Drive Controller - 110A Three-Phase BG6
  • LTi SO84.090 Servo Drive Controller - 90A Three-Phase BG6
  • LTi SO84.072 Servo Drive Controller - 72A Three-Phase BG5
  • LTi SO84.060 Servo Drive Controller - 60A Three-Phase BG5
  • LTi SO84.045 Servo Drive Controller - 45A Three-Phase BG5
  • LTi SO84.032 Servo Drive Controller - 32A Three-Phase BG4
  • LTi SO84.024 Servo Drive Controller - 24A Three-Phase BG4
  • LTi SO84.020 Servo Drive Controller - 20A Three-Phase BG3
  • LTi SO84.016 Servo Drive Controller - 16A Three-Phase BG3
  • LTi SO84.012 Servo Drive Controller - 12A Three-Phase BG2
  • LTi SO84.008 Servo Drive Controller - 8A Three-Phase BG2
  • LTi SO84.006 Servo Drive Controller - Three-Phase 230-480V 6A
  • LTi SO84.004 Servo Drive Controller - Three-Phase 230-480V 4A
  • LTi SO82.004 Servo Drive Controller - Single-Phase 230V 4A
  • HMS Anybus AB7646-F Gateway Manual
  • Schneider ATV930D75N4 Inverter Manual
  • Mitsubishi Q2ASHCPU-S1 System Manual
  • Fanuc A20B-3300-0319 Board Specification
  • Mitsubishi QD60P8-G Counter Module Guide
  • Nidec Unidrive M701 Inverter Manual
  • ABB AO895 Analog Output Module Guide
  • Mitsubishi Q2ASHCPU Controller System Manual
  • ABB Pluto S20 v2 Safety PLC Manual
  • Omron CJ1W-NC413 Position Module Manual
  • B&R X20AI4632 Analog Input Module 4 Channel
  • OMRON CS1G-CPU44H Ver. 4.1 CPU Unit PLC
  • Beckhoff EL2911-2200 TwinSAFE Logic Terminal for EtherCAT
  • Mitsubishi 2D-TZ368 Parallel I/O Interface Card
  • Mitsubishi A3ACPU PLC CPU Module for MELSEC A Series
  • Mitsubishi NF630-SEW 4P Adjustable Circuit Breaker 300-630A
  • Keyence XG-8700L Multi-camera Vision System for Inspection
  • Beckhoff C6017-0010 Ultra Compact Industrial PC
  • B&R 3AT660.6 PLC Module from Automation Panel Series
  • GE F31X300CCHALG2 PC Board with 531X133PRUAPG1 Card
  • STMicroelectronics STM32L100R8T6ATR MCU Arm Cortex-M3
  • Omron CS1W-CLK13 Controller Link Unit
  • Schneider BMENOC0301 Ethernet Communication Module
  • HELUKABEL Braids PLC-30 40 E2UK Braided Cable Sleeve
  • Pe323 h0102de323a0 PLC I/O Module
  • Mitsubishi GT2512-STBA GT2512-STBD HMI 12.1 Inch Touch Screen
  • Samsung LTM213UP01 21.3 Inch LCD Monitor Panel
  • Allen-Bradley 440R-W23219 Guardmaster Safety Relay
  • Beckhoff EL2535 EtherCAT Terminal PWM Output
  • HELUKABEL Braids PLC-40 55 E2UK Braided Cable Sleeve
  • Allen Bradley 1769-OB16 16-Point Sourcing Output Module
  • Balluff BES 516-604-DZ-3 Delay Safety Relay for Industrial Timing
  • Siemens 6GK7542-1AX10-0XE0 PROFIBUS Communication Module for S7-1500
  • GE IC693BEM340 FIP Controller for Series 90-30 PLC
  • OMRON C200HG-CPU63-E Programmable Logic Controller CPU Unit
  • Schneider EOCR-PMZ Relay Manual
  • Honeywell C36TC0UA21D0 Controller Specifications
  • Emerson Ovation VE4001S2T2B4 Input Module
  • Omron CJ1M-CPU22 CPU Specifications
  • Grundig NEA02 AES 0 Card Specifications
  • Omron CJ1W-AD081-V1 Analog Input Specifications
  • IDEC FS1A-C21S Safety Controller Manual
  • IFM O3D303 Smart 3D Sensor Specifications
  • Siemens 6SN1123-1AB00-0BA2 Power Module Guide
  • B&R 4PP035.0300-01 Power Panel Manual
  • Siemens 6ES7 153-2BA10-0XB0 IM Module
  • Beckhoff EL3356-0010 Analog Input Module
  • Siemens 3RW4037-1BB04 Soft Starter